Search NASA⌕ Search

SEARCH · Search NASA

Results for “Csp”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Development of a High-Efficiency Hot Gas Turbo-expander and Low-Cost Heat Exchangers for Optimized CSP Supercritical CO 2 Operation

Southwest Research Institute® (SwRI®) has developed a novel, high-efficiency, supercritical carbon dioxide (sCO 2 ), hot gas turbo-expander optimized for the highly-transient, solar-powerplant, duty-cycle profile. This MW-scale sCO 2 turbo-expander design advances the state-of-theart of sCO 2 turbo-expanders from a current Technology Readiness Level (TRL) of three (initial, small-scale, laboratory, size testing) to a full TRL6 (MW-scale prototype demonstration). A secondary objective of this project was to optimize novel compact heat exchangers for sCO 2 applications to drastically reduce their manufacturing costs. Significant learning was achieved on how to design and fabricate a more cost effective, high performance recuperator, at the MWt capacity. The sCO 2 turbo-expander and novel sCO 2 heat exchanger have been tested in a 1- MWe sCO 2 test loop, fabricated to demonstrate component performance and the performance of the optimized sCO 2 Brayton cycle over a wide range of part load conditions and during transient operations representative of a typical Concentrating Solar Power (CSP) duty cycle. The scalable sCO 2 expander design and improved heat exchanger address and close two critical technology gaps required for an optimized CSP sCO 2 power plant and provide a major stepping stone on the pathway to achieving CSP power at $\$ $0.06/kW-hr Levelized Cost of Electricity (LCOE), increasing energy conversion efficiency to greater than 50% and reducing total power block cost to below $\$ $1,200/kW installed. Construction of the facility and testing has been completed. Test targets of 1,320°F, 27,000 rpm, and 3,500 psi were reached during separate tests. Overall, the turbine saw 37.5 hours of operation with many other hours of testing and troubleshooting all of the loop components. All the test data and troubleshooting is useful and applicable for future tests and operations with not only this loop but in any sCO2 application.

14 SOLAR ENERGY↗

Wear in particle based CSP systems from particle abrasion and attrition at high temperature

High temperature particle-based receivers offer distinct advantages over conventional molten salt receivers due to their ability to achieve temperatures above 700 ºC, direct absorption of solar energy as they fall through a beam of concentrated sunlight, and the relative ease of storage (and retrieval using a secondary working fluid) in insulated storage tanks. The use of particles, however, also raises concerns with material degradation from the flow of hot or cold particles through discharge hoppers or along the inner receiver surfaces and other system components (e.g. tubes, valves etc.), depending on operating mode of the receiver. The flow of particles over surfaces may result in loss of material from abrasive wear, impact erosion from impingement under gravitational fall and particle attrition as particles fall and move on top of each other. In the present study, the performance of candidate materials and particles were evaluated through a series of abrasion erosion and particle attrition experiments at room temperature as well as at 800 °C. Candidate materials were subject to abrasive wear from particles at low particle to material velocities inside a resistance heated kiln, and analyzed for changes in mass and surface morphology using cross-sectional scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy (EDS) tests. The wear rate for different specimens was noted to be largely driven by the strength of chromia scales built on the specimens from exposure to high temperature. Particle attrition measurements explored the susceptibility of particles to breakdown from particle to particle interaction and the generation of fines from this process. At the low velocities expected in particle based CSP plants, the particles tested exhibited near negligible breakdown. However, changes in the particle hardness at 800 ºC resulted in a significantly higher particle breakdown to sizes <40 microns raising potential environmental concerns. In addition to particle breakdown, it was also noted that the sample had oxides from the stainless steel test setup mixed in with the particles. Similar oxides can be expected to turn up in the utility scale particle based CSP plants as well. The presence of oxide was also noted to affect the solar absorptivity of the mixture compared to a clean initial specimen, potentially resulting in a change in the overall efficiency of the CSP plant.

14 SOLAR ENERGY↗

100% Carbon-Free Electricity for Sandia NM and KAFB Using Concentrating Solar Power (CSP) (SAND Report)

This report provides a design study to produce 100% carbon-free electricity for Sandia NM and Kirtland Air Force Base (KAFB) using concentrating solar power (CSP). Annual electricity requirements for both Sandia and KAFB are presented, along with specific load centers that consume a significant and continuous amount of energy. CSP plant designs of 50 MW and 100 MW are then discussed to meet the needs of Sandia NM and the combined electrical needs of both Sandia NM and KAFB. Probabilistic modeling is performed to evaluate inherent uncertainties in performance and cost parameters on total construction costs and the levelized cost of electricity. Total overnight construction costs are expected to range between ~$300M - $400M for the 50 MW CSP plant and between ~$500M - $800M for the 100 MW plant. Annual operations and maintenance (O&M) costs are estimated together with potential offsets in electrical costs and CO 2 emissions. Other considerations such as interconnections, land use and permitting, funding options, and potential agreements and partnerships with Public Service Company of New Mexico (PNM), Western Area Power Administration (WAPA), and other entities are also discussed.

14 SOLAR ENERGY↗

CSP Historical Library Archive Extension Project Final Report

This work details the development of a concentrating solar power (CSP) and thermal (CST) library archive. This work included digitization of one-of-a-kind documents that could be degraded or destroyed over time. Sandia National Laboratories (SNL) National Solar Thermal Test Facility (NSTTF) and Sandia's Technical Library departments collaborated to establish and maintain the first and only digital collection in the world of Concentrating Solar Power (CSP) related historical documents. These date back to the CSP program inception here at Sandia in the early 1970's thru to the present.

14 SOLAR ENERGY↗

Novel Binderjet Additive Heat Exchangers: A Pathway to 5¢/kWh CSP

General Electric (GE) Research is developing a Binderjet manufacturing processes and heat exchanger core design to enable low-cost high temperature Recuperators (HTR) for Concentrated Solar Power (CSP) supercritical carbon dioxide (sCO2) power cycles. The objective is to show a path for greater than or equal to 10% cost reduction for an HTR that enables meeting the DOE SunShot goal of 5c/kWh for CSP plants. As part of the DOE program, GE is developing a novel trifurcating heat exchanger (HX) for HTR using binderjet additive manufacturing process that could meet the cost targets. As part of the 2021 CSP summit presentation, GE demonstrates that the build control of HX cores using the binderjet process are within the program targets. Preliminary cost estimates of the overall heat exchanger using a modular HX design shows cost reductions greater than 10% target allowing significant margin for assembly and inspections costs. Additional cost reduction plans are also highlighted.

14 SOLAR ENERGY↗

Improving Economics of Generation 3 CSP System Components Through Fabrication and Application of High Temperature Nickel-Based Alloys

To improve the efficiency and lower the cost of Concentrating Solar Power (CSP) plants, new Generation 3 ‘Gen 3’ CSP concepts using novel salts, solids, or gas heattransfer media envisaged to integrated with a supercritical CO 2 (sCO 2 ) power block at temperatures >715ºC are being investigated. Regardless of the specific pathway, critical components including receivers, piping, and heat-exchangers (HXs) will require the use of heat-resistant nickel-based alloys. Furthermore, the use of age-hardenable alloys, such as INCONEL® alloy 740H® (alloy 740H) may be needed to reduce capital cost. The unique challenges presented by CSP plants to material manufacture, such as small diameter thin-walled tubing in receivers, large diameter thin wall piping, and thin sheet and tubes for HXs can add to the cost to produce such alloys when compared to traditional wrought and cast processing. The goal of this project was to facilitate a reduction of plant cost by developing alternate manufacturing routes and quantifying the performance and economic benefits for alloy 740H in comparison to other candidate nickel-based alloys through fabrication trials, high-temperature mechanical property studies, and interactions with technology developers and codes and standards.

14 SOLAR ENERGY↗

Mise en Scene: Conversion of Scenarios to CSP Traces for the Requirements-to-Design-to-Code Project

The "Requirements-to-Design-to-Code" (R2D2C) project at NASA's Goddard Space Flight Center is based on deriving a formal specification expressed in Communicating Sequential Processes (CSP) notation from system requirements supplied in the form of CSP traces. The traces, in turn, are to be extracted from scenarios, a user-friendly medium often used to describe the required behavior of computer systems under development. This work, called Mise en Scene, defines a new scenario medium (Scenario Notation Language, SNL) suitable for control-dominated systems, coupled with a two-stage process for automatic translation of scenarios to a new trace medium (Trace Notation Language, TNL) that encompasses CSP traces. Mise en Scene is offered as an initial solution to the problem of the scenarios-to-traces "D2" phase of R2D2C. A survey of the "scenario" concept and some case studies are also provided.

Carter. John D.↗

A Comparison of Supercritical Carbon Dioxide Power Cycle Configurations with an Emphasis on CSP Applications (Presentation)

Recent research suggests that an emerging power cycle technology using supercritical carbon dioxide (s-CO2) operated in a closed-loop Brayton cycle offers the potential of equivalent or higher cycle efficiency versus supercritical or superheated steam cycles at temperatures relevant for CSP applications. Preliminary design-point modeling suggests that s-CO2 cycle configurations can be devised that have similar overall efficiency but different temperature and/or pressure characteristics. This paper employs a more detailed heat exchanger model than previous work to compare the recompression and partial cooling cycles, two cycles with high design-point efficiencies, and illustrates the potential advantages of the latter. Integration of the cycles into CSP systems is studied, with a focus on sensible heat thermal storage and direct s-CO2 receivers. Results show the partial cooling cycle may offer a larger temperature difference across the primary heat exchanger, thereby potentially reducing heat exchanger cost and improving CSP receiver efficiency.

14 SOLAR ENERGY↗

Low cost anti-soiling coatings for CSP collector mirrors and heliostats

Most concentrating solar power (CSP) facilities in the USA are located in the desert southwest of the country where land and sunshine are abundant. But one of the significant maintenance problems and cost associated with operating CSP facilities in this region is the accumulation of dust, sand and other pollutants on the collector mirrors and heliostats. In this paper we describe the development of low cost, easy to apply anti-soiling coatings based on superhydrophobic (SH) functionalized nano silica materials and polymer binders that posses the key requirements necessary to inhibit particulate deposition on and sticking to CSP mirror surfaces, and thereby significantly reducing mirror cleaning costs and facility downtime.

anti-soiling coatings↗

Analysis of the Impurity MgOHCl in Molten Chloride Salts Toward its Electrochemical Removal from CSP Plants During Operation

The work presented here is a study of the impurity MgOHCl in molten chloride salts, toward the eventual goal of electrochemically removing it from operational molten-chloride-based concentrating solar power (CSP) plants.1,2 Implementation of molten chloride salts as a heat transfer fluid is among the most promising pathways for decreasing the levelized cost of energy (LCOE) of CSP systems because its high thermal stability allows higher operating temperatures, and thus, greater efficiency. However, this impurity - formed when MgCl2 salts are exposed to air and moisture - cause significant corrosion of containment alloys.1 Therefore, we have developed and validated in a laboratory setting: 1) a method for the formation of MgOHCl for controlled impurity spike in molten salt for its further sensing, evaluation, and reduction; 2) evaluated its diffusion in the molten salt, and 3) began assessing its electrochemical properties. Our findings allow us to propose solutions for efficiently and instantly removing MgOHCl from an operational CSP plant.

concentrated solar power↗

Time integration of reacting flows with CSP tabulation.

This paper presents recent progress on the use of Computational Singular Perturbation (CSP) techniques for time integration of stiff chemical systems. The CSP integration approach removes fast time scales from the reaction system, thereby enabling integration with explicit time stepping algorithms. For further efficiency improvements, a tabulation strategy was developed to allow reuse of the relevant CSP quantities. This paper outlines the method and demonstrates its use on the simulation of hydrogen-air ignition.

08 HYDROGEN↗

An assessment of the net value of CSP systems integrated with thermal energy storage

Within this study, we evaluate the operational and capacity value—or total system value—for multiple concentrating solar power (CSP) plant configurations under an assumed 33% renewable penetration scenario in California. We calculate the first-year bid price for two CSP plants, including a 2013 molten-salt tower integrated with a conventional Rankine cycle and a hypothetical 2020 molten-salt tower system integrated with an advanced supercritical carbon-dioxide power block. The overall benefit to the regional grid, defined in this study as the net value, is calculated by subtracting the first-year bid price from the total system value.

14 SOLAR ENERGY↗

Review of Stack CSP Technologies

CSP is an emerging technology with significant potential growth in stacking. Many of the stacking techniques for conventional packages could be implemented for CSP once materials, process, and system development for finer features are developed.

3D CSP stack CSP Chip Scale Package MCM Mulitchip ↗

Solar Thermoelectricity via Advanced Latent Heat Storage: A Cost-Effective Small-Scale CSP Application

We are developing a novel concentrating solar electricity-generating technology that is both modular and dispatchable. Solar ThermoElectricity via Advanced Latent heat Storage (STEALS) uses concentrated solar flux to generate high-temperature thermal energy, which directly converts to electricity via thermoelectric generators (TEGs), stored within a phase-change material (PCM) for electricity generation at a later time, or both allowing for simultaneous charging of the PCM and electricity generation. STEALS has inherent features that drive its cost-competitive scale to be much smaller than current commercial concentrating solar power (CSP) plants. Most obvious is modularity of the solid-state TEG, which favors smaller scales in the kilowatt range as compared to CSP steam turbines, which are minimally 50 MWe for commercial power plants. Here, we present techno-economic and market analyses that show STEALS can be a cost-effective electricity-generating technology with particular appeal to small-scale microgrid applications. We evaluated levelized cost of energy (LCOE) for STEALS and for a comparable photovoltaic (PV) system with battery storage. For STEALS, we estimated capital costs and the LCOE as functions of the type of PCM including the use of recycled aluminum alloys, and evaluated the cost tradeoffs between plasma spray coatings and solution-based boron coatings that are applied to the wetted surfaces of the PCM subsystem. We developed a probabilistic cost model that accounts for uncertainties in the cost and performance inputs to the LCOE estimation. Our probabilistic model estimated LCOE for a 100-kWe STEALS system that had 5 hours of thermal storage and 8-10 hours of total daily power generation. For these cases, the solar multiple for the heliostat field varied between 1.12 and 1.5. We identified microgrids as a likely market for the STEALS system. We characterized microgrid markets in terms of nominal power, dispatchability, geographic location, and customer type, and specified additional features for STEALS that are needed to meet the needs of this growing power market.

14 SOLAR ENERGY↗

Design and Development of a Particle Flow Control Mechanism for Particle-Based CSP System Applications

Within particle-based Concentrated Solar Power Systems (CSP), particles are the heat transfer medium, and therefore, the heat transfer effectiveness of these systems is reliant on their ability to effectively control particle mass flow rate. The vast majority of approaches for particle flow control in high temperature CSP is based on a slide-gate approach where a gate is linearly actuated across a tear-drop shaped opening. The slide-gate mechanism has a sensitivity of 0.354 g/s-mm, which is defined as the mass flow rate over the position of the gate. In the present work, we have designed and tested a new particle flow control mechanism with the potential for faster response times and different sensitivities than a slide gate approach enabling more control of particle flow. The new device enables flow control through moving jaws diagonally to change the outlet area. The new devices sensitivity value follows a quadratic curved as compared to the slide-gate’s linear slope over the same jaw movement. A larger sensitivity value is directly related to a quicker response time when utilizing the same actuator.

14 SOLAR ENERGY↗

Reduced LCoE CSP Through Utilizing Process Gas Lubricated Bearings in Oil-Free Drivetrains

The GE Research team proposed to advance the TRL level of process lubricated gas bearings from TRL3 based on the DE-EE0007109 program to TRL5 addressing a critical risk item that radial gas bearings can provide satisfactory rotordynamic performance in supporting a representative rotor for sCO2 Power Cycles. The ability to apply process lubricated gas bearings can provide cost savings with reduction of the associated lube oil systems and an efficiency benefit worth 2% efficiency for the turbomachinery configuration first presented in DE-EE005804. The process lubricated gas bearings are enablers for advanced hermetically sealed configurations that have the potential for significant advancement in sCO2 Power Cycles for CSP applications including the 2% efficiency increase referred to above in addition to OPEX savings with no need to refill the CO2 valued at 60k USD/yr and cost reductions of 50 USD/kWe all leading to a potential 0.95¢/kWh reduction positively impacting CSP goals.

14 SOLAR ENERGY↗

Modeling and Analysis of CSP Systems (Fact Sheet)

Fact sheet describing NREL CSP Program capabilities in the area of modeling and analysis of CSP systems: assessing the solar resource, predicting performance and cost, studying environmental impact, and developing modeling software packages.

14 SOLAR ENERGY↗

AATTENUATION—The Atmospheric Attenuation Model for CSP Tower Plants: A Look-Up Table for Operational Implementation

Attenuation of solar radiation between the receiver and the heliostat field in concentrated solar power (CSP) tower plants can reduce the overall system performance significantly. The attenuation varies strongly with time and the average attenuation at different sites might also vary strongly from each other. If no site specific attenuation data is available, the optimal plant design cannot be determined and rough estimations of the attenuation effect are required leading to high uncertainties of yield analysis calculations. The attenuation is caused mainly by water vapor content and aerosol particles in the lower atmospheric layer above ground. Although several on-site measurement systems have been developed during recent years, attenuation data sets are usually not available to be included during the plant project development. An Atmospheric Attenuation (AATTENUATION) model to derive the atmospheric transmittance between a heliostat and receiver on the basis of common direct normal irradiance (DNI), temperature, relative humidity, and barometric pressure measurements was developed and validated by the authors earlier. The model allows the accurate estimation of attenuation for sites with low attenuation and gives an estimation of the attenuation for less clear sites. However, the site-dependent coefficients of the AATTENUATION model had to be developed individually for each site of interest, which required time-consuming radiative transfer simulations, considering the exact location and altitude, as well as the pre-dominant aerosol type at the location. This strongly limited the application of the model despite its typically available input data. In this manuscript, a look-up table (LUT) is presented which enables the application of the AATTENUATION model at the site of interest without the necessity to perform the according complex radiative transfer calculations for each site individually. This enables the application of the AATTENUATION model for virtually all resource assessments for tower plants and in an operational mode in real time within plant monitoring systems around the world. The LUT also facilitates the generation of solar attenuation maps on the basis of long-term meteorological data sets which can be considered during resource assessment for CSP tower plant projects. The LUTs are provided together with this manuscript as supplementary files. The LUT for the AATTENUATION model was developed for a solar zenith angle (SZA) grid of 1°, an altitude grid of 100 m, 7 different standard aerosol types and the standard AFGL atmospheres for mid-latitudes and the tropics. The LUT was tested against the original version of the AATTENUATION model at 4 sites in Morocco and Spain, and it was found that the additional uncertainty introduced by the application of the LUT is negligible. With the information of latitude, longitude, altitude above mean sea level, DNI, relative humidity (RH), ambient temperature (Tair), and barometric pressure (bp), the attenuation can be now derived easily for each site of interest.

14 SOLAR ENERGY↗