Search NASA⌕ Search

SEARCH · Search NASA

Results for “Curve fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Propellant Mass Gauging in a Spherical Tank under Micro-Gravity Conditions Using Capacitance Plate Arrays and Machine Learning

Propellant mass gauging under micro-gravity conditions is a challenging task due to the unpredictable position and shape of the fuel body inside the tank. Micro-gravity conditions are common for orbiting satellites and rockets that operate on limited fuel supplies. Capacitance sensors have been investigated for this task in recent years; however, the effect of various positions and shapes of the fuel body is not analyzed in detail. In this paper, we investigate this with various fill types, such as annular, core-annular, and stratified fills at different positions. We compare the performance among several curve-fitting-based approaches and a machine-learning-based approach, the latter of which offers superior performance in estimating the fuel content.

47 OTHER INSTRUMENTATION↗

Using Host Galaxy Photometric Redshifts to Improve Cosmological Constraints with Type Ia Supernovae in the LSST Era

We perform a rigorous cosmology analysis on simulated Type Ia supernovae (SNe Ia) and evaluate the improvement from including photometric host galaxy redshifts compared to using only the "z spec " subset with spectroscopic redshifts from the host or SN. We use the Deep Drilling Fields (~50 deg 2 ) from the Photometric LSST Astronomical Time-Series Classification Challenge (PLAsTiCC) in combination with a low-z sample based on Data Challenge2. The analysis includes light-curve fitting to standardize the SN brightness, a high-statistics simulation to obtain a bias-corrected Hubble diagram, a statistical+systematics covariance matrix including calibration and photo-z uncertainties, and cosmology fitting with a prior from the cosmic microwave background. Compared to using the z spec subset, including events with SN+host photo-z results in (i) more precise distances for z > 0.5, (ii) a Hubble diagram that extends 0.3 further in redshift, and (iii) a 50% increase in the Dark Energy Task Force figure of merit (FoM) based on the w 0 w a CDM model. Analyzing 25 simulated data samples, the average bias on w 0 and w a is consistent with zero. The host photo-z systematic of 0.01 reduces FoM by only 2% because (i) most z < 0.5 events are in the z spec subset, (ii) the combined SN+host photo-z has ×2 smaller bias, and (iii) the anticorrelation between fitted redshift and color self-corrects distance errors. To prepare for analyzing real data, the next SN Ia cosmology analysis with photo-zs should include non–SN Ia contamination and host galaxy misassociations.

79 ASTRONOMY AND ASTROPHYSICS↗

Follow-up Survey for the Binary Black Hole Merger GW200224_222234 Using Subaru/HSC and GTC/OSIRIS

The LIGO/Virgo detected a gravitational wave (GW) event, named GW200224_222234 (also known as S200224ca) and classified as a binary-black hole coalescence, on 2020 February 24. Given its relatively small localization skymap (71 deg 2 for a 90% credible region; revised to 50 deg 2 in GWTC-3), we performed target-of-opportunity observations using the Subaru/Hyper Suprime-Cam (HSC) in the r2 and z bands. Observations were conducted on 2020 February 25 and 28 and March 23, with the first epoch beginning 12.3 hr after the GW detection. The survey covered the highest-probability sky area of 56.6 deg 2 , corresponding to a 91% probability. This was the first deep follow-up (m r ≳ 24, m z ≳ 23) for a binary-black hole merger covering >90% of the localization. By performing image subtraction and candidate screening including light-curve fitting with transient templates and examples, we found 22 off-nucleus transients that were not ruled out as the counterparts of GW200224_222234 with our Subaru/HSC data alone. We also performed GTC/OSIRIS spectroscopy of the probable host galaxies for five candidates; two are likely to be located within the 3D skymap, whereas the others are not. In conclusion, 19 transients remain as possible optical counterparts of GW200224_222234; but we could not identify a unique promising counterpart. If there are no counterparts in the remaining candidates, the upper limits of the optical luminosity are $\nu {L}_{\nu }\lt {5.2}_{-1.9}^{+2.4}\times {10}^{41}$ erg s -1 and $\nu {L}_{\nu }\lt {1.8}_{-0.6}^{+0.8}\times {10}^{42}$ erg s -1 in the r2 and z bands, respectively, at ~12 hr after GW detection. We also discuss improvements in the strategies of optical follow-ups for future GW events.

79 ASTRONOMY AND ASTROPHYSICS↗

A Comprehensive Open-Source R Software For Statistical Metrology Calculations: From Uncertainty Evaluation To Risk Analysis

Whether calibrating equipment or inspecting products on the factory floor, metrology requires many complicated statistical calculations to achieve a full understanding and evaluation of measurement uncertainty and quality. In order to assist its workforce in performing these calculations in a consistent and rigorous way, the Primary Standards Lab at Sandia National Laboratories (SNL) has developed a free and open-source software package for computing various metrology calculations from uncertainty propagation to risk analysis. In addition to propagating uncertainty through a measurement model using the well-known Guide to Expression of Uncertainty in Measurement or Monte Carlo approaches, evaluating the individual Type A and Type B uncertainty components that go into the measurement model often requires other statistical methods such as analysis of variance or determining uncertainty in a fitted curve. Once the uncertainty in a measurement has been calculated, it is usually evaluated from a risk perspective to ensure the measurement is suitable for making a particular conformance decision. Finally, SNL’s software can perform all these calculations in a single application via an easy-to-use graphical interface, where the different functions are integrated so the results of one calculation can be used as inputs to another calculation.

97 MATHEMATICS AND COMPUTING↗

Planetary Boundary Layer Height derived from MPL data using Sawyer-Li method

Sawyer and Li (2013) developed a technique to derive the PBL height from micropulse lidar (MPL) backscatter measurements using combined wavelet covariance transform and iterative curve-fitting methods. The wavelet covariance transform method applies a Haar wavelet function to MPL backscatter signals (Brooks et al., 2003).

54 ENVIRONMENTAL SCIENCES↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis – Simulated Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wind turbine. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen . While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the simulated wind energy profiles, NLR used OpenFAST to simulate a 3.4-MW International Energy Agency (IEA) reference wind turbine. The hour-long wind energy profiles varied over wind turbulence intensity (Class A or Class C) and average wind speed (5, 7, or 9 m/s). To match the power limits of the 1.25-MW electrolyzer and 3.4-MW IEA wind turbine most effectively and to maximize the efficiency of hydrogen production at a given average wind speed, the profiles were sometimes scaled by two times. This means that, in some cases, the experimental setup assumed two 1.25-MW electrolyzers were coupled with the wind turbine, representing a total maximum electrolysis load of 2.5 MW. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}-{average wind speed}-{turbulence class}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “windIEA3.4-5ms-C_2-400.zip” represents the hour-long experiment using the IEA 3.4-MW turbine, subjected to an average wind speed of 5 m/s and Class C wind turbulence, and connected to two 1.25-MW electrolyzers with the power supply set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wind turbine power. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Wave

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production using a single, simulated wave energy conversion device. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel Hydrogen. While the unit supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. For the wave energy, NLR used a wave energy converter model from PacWave. These devices can be equipped with accumulators and pressure relief values to smooth the power output by storing and releasing hydraulic energy. Using a peak power output of 10 MW, the model created two 25-minute profiles: one with and one without the accumulators and pressure relief valves. To down select the profile data from the native resolution of 20 Hz to 1 Hz, NLR took the mean of every 20 data points. NLR experimented with two simulated wave energy power plants: one that peaks at 10 MW, and one that peaks at 5 MW. These profiles were scaled for the physical 1.25 MW electrolyzer by multiplying the original profiles by one eighth and one quarter, respectively. The first profile matches the capacity rating of eight of the 1.25 MW electrolyzers, while the second matches four electrolyzers. Finally, NLR experimented with two settings for the electrolyzer power supply minimum and maximum current ramp rates (gain and slew): 200 and 400 amperes per second. The simulated profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wave electrolysis experiment and is formatted as follows: {technology}-{accumulator?}_{number of 1.25 MW electrolyzers connected}-{electrolyzer ramp rate in amperes/second} For instance, “wavePacWave-Noacc_4-400.zip” represents the 25 minute-long experiment using the PacWave’s wave energy converter model, equipped with no accumulator, connected to four 1.25-MW electrolyzers with their power supplies set to a maximum current ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. An experiment, labeled “characterization_200.zip”, demonstrates the MC250 electrolyzer steady-state response with 30 minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all wave profiles combined into one dataset labeled "combined_wave_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Wind

The U.S. Department of Energy and the National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence (AI) data centers and other variable loads. This dataset entry describes hydrogen production by conducting a statistical analysis of historical wind data over a five-year period (2020-2025) from a single 1.5MW turbine manufactured by General Electric (GE) located at NLR’s Flatirons Campus, to generate an experimental test profile that was deployed on a 1.25-MW proton exchange membrane type MC250 electrolyzer system manufactured by Nel Hydrogen . [1] While the electrolyzer balance-of-plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack. The historical wind data provided several metrics, however, the analysis particularly focused on the measured power output by the wind turbine. The power output time series of data for each day was categorized by total energy generation and standard deviation, and the day that represented the highest combination of these two metrics was chosen – December 25th, 2022. This process was then repeated for a moving four-hour window within this day to identify the most statistically variable period. Finally, this four-hour period was scaled by 65% to match the 1.25 MW electrolyzer. The electrolysis system controls hydrogen production by varying DC current applied to the stack, from a maximum of 3000 A to a minimum safe operation of 300 A, or 10%. Because the current – voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical wind profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1 Hz frequency. For more details on the statistical analysis process, see the presentation labeled “ Public Reference Data for Megawatt-Scale Hydrogen Electrolysis” provided with each data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single wind turbine electrolysis experiment and is formatted as follows: {technology}_{scaling factor}-{electrolyzer ramp rate in amperes/second} For instance, “wind-GE1.5MW_0.65-400.zip” represents the hour-long experiment using historical data from the wind-GE1.5MW turbine, scaled to 65%, with the electrolyzer power supply set to a maximum ramp rate (gain and slew) of 400 A/s. Each .zip folder contains the following files: A .csv file containing raw data An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and wind power input. A PDF file detailing the historical wind data statistical analysis used to generate the wind profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all simulated wind experiments combined into one dataset labeled "combined_historical_wind_experiments.csv". NLR also built an AI/machine-learning predictive model based on these datasets. The model ingests the electrolyzer current command in amperes, as well as various pressures and temperatures across the system, and predicts hydrogen output in kilograms per hour. The complete model can be found at https://huggingface.co/NatLabRockies/ptmelt-hydrogen-electrolysis [1] nelhydrogen.com/product/mc-series-electrolyser .

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - Simulated Marine Hydrokinetic Tidal Turbine

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis, hydrogen compression and storage, and variable hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) initiative. This dataset is part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with other energy technologies. This dataset contains inputs and outputs from simulations of a floating marine hydrokinetic turbine over approximately half a tidal cycle (~6.6 hours). Inflow conditions were derived from field measurements in Alaska’s Cook Inlet and represent a tidal environment in which the current speed ramps from near 0 m/s to a peak of 3 m/s and back. The original acoustic doppler current profiler dataset is publicly available on the Marine and Hydrokinetic Data Repository. In a full tidal cycle, the flow reverses and the rotor would reorient; this reversal was not modeled. In the Cook Inlet campaign , turbulence intensity was similar in both directions. Two inflow cases are included. In the first case, labeled “raw” in the files, the measured current time series was used directly in the InflowWind module of OpenFAST. Speed and direction were applied as a function of time and elevation, uniformly in the horizontal direction. With full spatial coherence, this approach captures high turbulent variability and results in pronounced power fluctuations, so it is considered a conservative, near-worst-case representation of loading. In the second case, labeled “average” in the files, a 30-minute moving average was applied to extract the slowly varying mean speed. The residual fluctuations about this mean were used to generate spatially varying, full-field turbulence inputs with TurbSim, giving a more physically realistic representation of the inflow across the rotor disk. Two random realizations were used to produce distinct inflow conditions for two OpenFAST simulations representing a two-turbine array. The same turbulence intensity is applied across the full time series, producing larger fluctuations at the start and end, where the mean speed is low. The second case is the more appropriate framework for performance and power assessment but overpredicts turbulence at lower flow speeds and underpredicts it at higher speeds. As the floating platform moves and the rotor changes its x-position, Taylor’s frozen turbulence hypothesis used by InflowWind assumes a constant rather than a time-varying mean velocity, introducing some inaccuracy in the velocity plane sampling. The turbine modeled is the 500-kW Reference Model 1, a horizontal-axis two-bladed hydrokinetic turbine on a four-column floating semisubmersible substructure . Simulations were performed using OpenFAST v4.1 with the Reference Open Source Controller (ROSCO) v2.10. All input files required to reproduce the simulations are included. The electrolyzer is a 1.25-MW proton exchange membrane type MC250 system manufactured by Nel . This unit supports up to 2.5 MW, but NLR has only a single 1.25-MW stack. The datasets report hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. The system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operating current of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The simulated tidal turbine time series data was translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz. Each zip file represents a single tidal electrolysis experiment and is named: {technology}_{inflow method}_{number of 500 kW tidal turbines connected} For instance, “tidal-500kW-RM1_average_2.zip” is a 6-hour experiment using the 500-kW tidal reference model, scaled by 2x (1-MW) to better match the electrolyzer maximum of 1.25MW, fed with the 30-minute moving average current case. Each zip folder contains the following files: A .csv file of raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production in kilograms per hour, electrolysis power consumption, and input wave power. A .csv file combines all tidal profiles as "combined_tidal_experiments.csv." A separate experiment, “characterization_200.zip,” shows the MC250 electrolyzer steady-state response with 30-minute load steps over 5 hours and is accessible with this entry.

08 HYDROGEN↗

Public Reference Data for Megawatt-Scale Hydrogen Electrolysis - NLR Historical Solar PV

The U.S. Department of Energy and National Laboratory of the Rockies (NLR) demonstrate hydrogen electrolysis from variable sources, hydrogen compression and storage, and hydrogen fuel cell power production using megawatt-scale equipment at NLR’s Flatirons Campus as part of the Advanced Research on Integrated Energy Systems (ARIES) research platform. This dataset represents part of that effort and is intended for academic, national laboratory, industrial, and other stakeholders to plan, design, and validate models of megawatt-scale hydrogen technologies and diverse energy infrastructure nationwide. These data provide a baseline for how existing hydrogen electrolysis technologies perform when coupled with various energy technologies. Future datasets will demonstrate how existing hydrogen fuel cell technologies can provide controllable, dispatchable, and variable power output for artificial intelligence data centers and other variable loads. This dataset entry describes the behavior of a 1.25-MW proton exchange membrane MC250 electrolyzer system, manufactured by Nel Hydrogen , [1] when fed historical data generated by the 430-kW, fixed-axis solar photovoltaic (PV) array located at NLR’s Flatirons Campus. (While the electrolyzer balance of plant supports up to 2.5 MW of electrolysis, NLR only has a single 1.25-MW electrolysis stack.) Solar PV power output data for the 2020 calendar year were categorized on a daily basis by total energy generation and standard deviation. Each day was then ranked by these metrics, and the 25th, 50th, and 100th percentiles were selected. The 75th percentile day did not exhibit sufficient variability to make for a valuable experiment. A similar process was used for the related historical wind dataset . [2] The historical days in 2020 that represented these percentiles are Dec. 19, March 29, and May 4, respectively. The entire solar day’s power profile was then fed through the MC250 electrolyzer. Due to its length, the 100th percentile day experiment was split into two parts, and the final 3 hours of the solar day were not captured. These final 3 hours contained no spikes or dips of interest and simply represented a slow decay of input solar power. Also, a single timestamp (13:13:47 on Jan. 14, 2026) was lost in the hydrogen system supervisory control and data acquisition. Finally, during the 25th percentile experiment (solar day Dec. 19, 2020) data recording was lost from 11:00:13 to 11:14:45. The roughly 15 minutes of the solar profile were rerun at the end of the experiment and spliced into this time slot during post-processing. The electrolysis system controls hydrogen production by varying direct current applied to the stack, from a maximum of 3,000 A to a minimum safe operation of 300 A, or 10%. Because the current–voltage characteristic changes as the stack ages and efficiency degrades, the actual minimum safe operating power changes over time. The historical solar profiles were translated from power (kilowatts) to current (amperes) using a curve fit with calibration data and sent to the electrolyzer power supply at 1-Hz frequency. For more details on the statistical analysis process, see the slide deck “Public Reference Data for Megawatt-Scale Hydrogen Electrolysis: NLR Historical Solar PV Analysis and Profile Generation” accessible with this data entry. These datasets report relevant hydrogen balance-of-plant and system data, all captured at 1 Hz, including hydrogen mass production measured with an Emerson Coriolis flow meter. Each .zip file represents a single solar PV electrolysis experiment and is formatted as: {technology}_{percentile}_{scaling factor} For instance, “solarPV-430kW_25_2x.zip” reports the experiment using the 25th percentile solar data from the historical 2020 solar PV dataset, scaled to 200%. Scaling factors were applied to the generated solar PV power output files to more closely match the 1.25-MW capacity of the electrolyzer. Each .zip folder contains the following files: A .csv file containing raw data. An .xlsx file explaining all the fields in the raw data. A .png plot showing the time series of hydrogen production, electrolysis power consumption, and solar power input. A PDF file detailing the historical solar data statistical analysis used to generate the solar profile. An experiment labeled “characterization_200.zip” demonstrates the MC250 electrolyzer steady-state response with 30-minute load steps for a total duration of 5 hours. Finally, a .csv file is provided with all experiments combined into one dataset labeled "combined_solarPV_experiments.csv". [1] nelhydrogen.com/product/mc-series-electrolyser . [2] data.nlr.gov/submissions/316 .

08 HYDROGEN↗

Thermal Model Heat Rate Predictions of the AGR-5/6/7 Experiment

Several fuel and material irradiation experiments have been planned for the U.S. Department of Energy Advanced Gas Reactor Fuel Development and Qualification Program, which supports the development and qualification of tristructural isotropic (TRISO) coated particle fuel for use in high-temperature gas-cooled reactors. The goals of these experiments are to provide irradiation performance data to support fuel process development, qualify fuel for normal operating conditions, support development of fuel performance models and codes, and provide irradiated fuel and materials for post-irradiation examination and safety testing. Originally planned and named as separate fuel experiments, but subsequently combined into a single test train. AGR-5/6/7 will test low-enriched uranium oxycarbide (UCO – a heterogeneous mixture of uranium oxide and uranium carbide) TRISO fuel. The AGR-5/6 portion of the experiment will provide data to support qualification of the selected reference fuel design, while the AGR-7 portion will serve as a margin test, irradiating the fuel beyond normal operating conditions. During irradiation, the temperature in each capsule is controlled by varying the helium / neon gas mixture flowing through the capsule until the desired thermocouple temperature is reached. Further adjustments can be made by changing the lobe power and the neutron filter. Three neutron filters are available to use as the experiment burns up the fissionable fuel. A thermal finite element model has been created for the five capsules comprising the AGR-5/6/7 experiment. Heat rates from a physics analysis are imported into the model along with fast neutron fluence. Graphite shrinkage due to the fast neutron fluence is incorporated into the model. Gas gaps change as a function of fast neutron fluence. Radiation heat transfer is a major contributor in this model. This is a large model with more than 1 million finite element brick elements. More than 150 different parts are modeled in the finite element model and communicate with each other from a heat transfer sense. More than 50 thermocouples are used in the experiment and are compared to actual measurements. The experiment is composed of five separate stainless steel capsules all welded together. This paper presents a method used to predict the gas mixture in the event that all of the thermocouples fail in a particular capsule. Curve fitting of heat rates from previous cycles and projecting them into the future is the basis of the method.

36 MATERIALS SCIENCE↗

Full circle mechanical dynamic characterization including experimental modal analysis and finite element analysis

During operation, it was observed that a specific mechanical system experienced undesirable vibration and it became necessary to understand and mitigate this phenomenon. This document investigates the tools, methodology, and results of the dynamic characterization of the system. The characterization makes use of the experimental modal analysis (EMA) methods of single input multiple output (SIMO) and single input single output (SISO). The validity of the theory of reciprocity is confirmed to minimize measurement error, cost, and time of repeat testing. Finite element analysis (FEA) is used in choosing transducer and modal impact locations to adequately characterize the system. Single degree of freedom (SDOF) and multiple degree of freedom (MDOF) curve fitting is used to fully characterize the system’s mode shapes and natural frequencies. The EMA characterization results are used to modify and validate the FEA model so that FEA can be used to model potential structural modifications to the system to mitigate the undesirable vibration. Structural modifications are chosen, implemented, and their effectiveness is quantified using EMA. Finally, a qualitative evaluation of the methodology of FEA validation by EMA and tuning of the model to match the experimental results is discussed.

42 ENGINEERING↗

Conversion of Resonance Parameters Between Wigner-Eisenbud R-matrix and Transition Matrix Pole Representation

The goal of this research is to develop a numerical code for translation between the current standard, Wigner-Eisenbud R-matrix parameters and a novel pole-representation of cross sections. The method follows Ducru et al. and constructs the conversion between these parametric representations of the scattering and reaction data. This pole representation, which expresses cross sections as a sum of simple poles (and their attendant residues), is examined in the context of the advantages provided by this compact, computationally efficient representation. These advantages include the ability to doppler broaden cross sections on-the-fly as well as a lower memory footprint when generating cross sections, an attractive feature to those interested in parallel GPU based Monte Carlo. Some conversion methods between R-matrix parameters and S-matrix poles have relied on curve fitting techniques. It is unknown weather these numerical methods necessarily preserve certain underlying physics properties of the standard R-matrix cross section model (such as unitarity). The direct conversion studied here aim to preserve such properties. This knowledge is of interest for future work into the generation of resonance parameter sensitivities.

CLUTCH↗

Technoeconomic Analysis of Changing PV System Layout and Convection Heat Transfer

This work includes analysis of potential economic improvements for PV systems for changing system parameters such as ground coverage ratio that alter the convective cooling consideration on PV modules through a newly proposed convective curve fit. Accounting for the spatial layout of the system in the convection heat transfer calculations allows for more accuracy in convective cooling load and subsequent module temperature calculations. The changing heat transfer considerations can be shown to improve system LCOE along with improved incident irradiance from increased row spacing despite the additional system costs incurred with increased module spacing. State-level analyses show that the impact of decreasing system GCR is greatest for climates with cold average annual ambient temperatures and moderate to high average annual wind speeds. Further waterfall analysis of changing system parameters reveals that the changing heat transfer dynamics have a non-negligible impact on system LCOE when compared to the changes in incident irradiance that serve as the primary driver of annual energy performance changes.

ENERGY PLANNING, POLICY, AND ECONOMY,SOLAR ENERGY↗

Variable gap thermal conductivity apparatus and method

An apparatus and a method for determining the thermal conductivity of a fluid specimen are provided. The apparatus and the method include determining thermal conductivity using a quasi-steady state variable gap axial flow technique. The fluid specimen is heated on one side by a heat source with a known power output and cooled on the other side. After reaching steady state, a resulting temperature drop through the fluid specimen exists. This temperature drop, the known fluid specimen thickness (or gap distance), and the known power output are used to calculate the thermal resistance of the fluid specimen. The thermal conductivity of the fluid specimen is then determined using a curve fit of thermal resistance with respect to gap distance.

Gallagher, Ryan C.↗

Calibration approach and range of observed sap flow influences transpiration estimates from thermal dissipation sensors

Calibrating thermal dissipation (TD) sap flow sensors has become increasingly important to accurately estimate whole-tree transpiration, but it is unclear how the calibration approach itself influences the resulting coefficients and estimates. Here, we compare the two most common calibration approaches, gravimetric and potometric, using TD sensors inserted into Eucalyptus benthamii tree stems. The gravimetric approach uses an excised stem segment devoid of branches and leaves and pushes water through the stem using gravity, a positive force. The potometric approach uses a severed stem containing an intact canopy placed upright in a reservoir where water is pulled through the stem via transpiration, a negative force. We hypothesized that the positive pressure associated with gravimetric calibration would overestimate conductive sapwood area relative to that estimated from potometric calibration and that coefficients from these different approaches would result in different estimates of transpiration when applied to intact trees. We also predicted that calibrations could improve transpiration estimates by targeting the range of observed sap flow rates (i.e., K values) in intact trees. Conductive sapwood area was higher under gravimetric calibrations and resulting estimates of transpiration were lower compared to potometric calibrations. Segmented calibration curves, which fit two separate curves for the relationship between sap flux density (Fd) and sap flux index (K) based on the range of sap flow rates observed in intact trees, increased transpiration estimates from both gravimetric and potometric coefficients and diminished the magnitude of difference in transpiration estimates between approaches. Researchers should be aware that calibration approach and range of observed sap flow profoundly influences transpiration estimates from TD sensors and this likely applies to calibrations of other heat-based sap flow sensors.

54 ENVIRONMENTAL SCIENCES↗

Influenza A viral burst size from thousands of infected single cells using droplet quantitative PCR (dqPCR)

An important aspect of how viruses spread and infect is the viral burst size, or the number of new viruses produced by each infected cell. Surprisingly, this value remains poorly characterized for influenza A virus (IAV), commonly known as the flu. In this study, we screened tens of thousands of cells using a microfluidic method called droplet quantitative PCR (dqPCR). The high-throughput capability of dqPCR enabled the measurement of a large population of infected cells producing progeny virus. By measuring the fully assembled and successfully released viruses from these infected cells, we discover that the viral burst sizes for both the seasonal H3N2 and the 2009 pandemic H1N1 strains vary significantly, with H3N2 ranging from 10 1 to 10 4 viruses per cell, and H1N1 ranging from 10 1 to 10 3 viruses per cell. Some infected cells produce average numbers of new viruses, while others generate extensive number of viruses. In fact, we find that only 10% of the single-cell infections are responsible for creating a significant portion of all the viruses. This small fraction produced approximately 60% of new viruses for H3N2 and 40% for H1N1. On average, each infected cell of the H3N2 flu strain produced 709 new viruses, whereas for H1N1, each infected cell produced 358 viruses. This novel method reveals insights into the flu virus and can lead to improved strategies for managing and preventing the spread of viruses.

60 APPLIED LIFE SCIENCES↗

A revised SALT2 surface for fitting Type Ia supernova light curves

ABSTRACT We present a revised Spectral Adaptive Light Curve Template (SALT2) surface (SALT2-2021) for fitting the light curves of Type Ia supernovae (SNe Ia), which incorporates new measurements of zero-point calibration offsets and Milky Way extinction. The most notable change in the new surface occurs in the UV region. This new surface alters the distance measurements of SNe Ia, which can be used to investigate the nature of dark energy by probing the expansion history of the Universe. Using the revised SALT2 surface on public data from the first 3 yr of the Dark Energy Survey Supernova Program (combined with an external low-z SNe Ia sample) and combining with cosmic microwave background constraints, we find a change in the dark energy equation-of-state parameter, Δw = 0.015 ± 0.004. This result highlights the continued importance of controlling and reducing systematic uncertainties, particularly with the next generation of supernova analyses aiming to improve constraints on dark energy properties.

79 ASTRONOMY AND ASTROPHYSICS↗