Search NASA⌕ Search

SEARCH · Search NASA

Results for “Curved detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

UFCC Calibration Measurements for UO2 Samples

The uranium UF 6 coincidence counter (UFCC) was designed to measure 5A/B cylinders containing UF6 in the passive neutron self-interrogation mode. The purpose of the present report is to extend the UFCC capability to other sample types such as oxides and liquids that might be found during verification activities. A 252 Cf source was introduced into the detector to make the active mode measurements possible, because only the UF 6 samples have adequate neutron emission for self-interrogation. A customized HDPE insert was designed to position the 252 Cf source under the UO 2 sample cans. The sample enrichments varied from depleted to 93% to establish the shape of the calibration curve and the measurement uncertainties.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80- channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, opensource pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BatAnalysis - A Comprehensive Python Pipeline for Swift BAT Survey Analysis

The Swift Burst Alert Telescope (BAT) is a coded-aperture gamma-ray instrument with a large field of view that primarily operates in survey mode when it is not triggering on transient events. The survey data consist of 80-channel detector plane histograms that accumulate photon counts over periods of at least 5 minutes. These histograms are processed on the ground and are used to produce the survey data set between 14 and 195 keV. Survey data comprise >90% of all BAT data by volume and allow for the tracking of long-term light curves and spectral properties of cataloged and uncataloged hard X-ray sources. Until now, the survey data set has not been used to its full potential due to the complexity associated with its analysis and the lack of easily usable pipelines. Here, we introduce the BatAnalysis Python package, a wrapper for HEASoftpy, which provides a modern, open-source pipeline to process and analyze BAT survey data. BatAnalysis allows members of the community to use BAT survey data in more advanced analyses of astrophysical sources, including pulsars, pulsar wind nebula, active galactic nuclei, and other known/unknown transient events that may be detected in the hard X-ray band. We outline the steps taken by the Python code and exemplify its usefulness and accuracy by analyzing survey data of the Crab Nebula, NGC 2992, and a previously uncataloged MAXI transient. The BatAnalysis package allows for ~18 yr of BAT survey data to be used in a systematic way to study a large variety of astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Spectator Proton Detection and Reconstruction in Deep Inelastic D(E,EPS) Scattering

A Radial Time Projection Chamber (RTPC) was designed and installed in Jefferson Lab's Hall B as part of the BONuS12 (Barely Off-shell Nucleon Structure) experiment. The goal of BONuS12 is to accurately measure the structure function of the neutron by scattering 11 GeV electrons and detecting them with the CLAS12 spectrometer. Deuterium gas was used as an effective neutron target, and the new RTPC was used to detect low momentum spectator protons. Protons follow a curved path in the 5 Tesla solenoid that is part of CLAS12, ionizing the He-CO2 gas in an annular drift region surrounding the target. These ionization electrons are radially drifted outwards, amplified using cylindrical GEM (Gaseous Electron Multiplication) foils and recorded using readout pads located along the entire outer face of the cylindrical detector. The particle track reconstruction software discussed in detail in this thesis uses the signals from these pads to build tracks, which are reconstructed into the drift region using the arrival times of the signals and the positions of the pads. The proton momentum is measured from the track?s curvature and thus used to extract information about the struck neutron. This thesis introduces the theory of spectator tagging as an effective strategy for measuring neutron structure, by minimizing nuclear effects in the absence of a free neutron target. Along with discussing the many detectors that make up the CLAS12 spectrometer, the RTPC will be covered in detail, along with the tracking software designed to interpret the electronic signals to rebuild the low-momentum particle tracks, and fit them to extract the relevant kinematics. The results of the software, and preliminary analysis will be shown in the final chapter, as well as the discussion of possible improvements which could be made to the tracking software.

Payette, David↗

X-ray Irradiance Distribution for an Interferometer with a Curved Biprism Array

The development of interferometry-based X-ray phase contrast imaging systems that provide highly resolved X-rays with spatially-modulated intensity is enabling the full potential of X-ray optics to image phase, attenuation, and small angle scatter properties of soft tissue. In this work we present analytical formulations of a new hardware concept for X-ray phase contrast imaging wherein the phase grating is replaced with an array of Fresnel biprisms. We derive expressions for the irradiance distribution pattern of a biprism interferometer composed of a curved biprism array with multiple biprisms and multiple point sources. These expressions are used to plot fringe patterns for X-ray design parameters, including 1) size, number, and period of X-ray point sources; 2) biprism parameters of material composition, angle, number, and period; and 3) biprism array to X-ray source and detector distances. Analytical results show that the biprism interferometer provides a longitudinally-nonperiodic pattern of spatially modulated intensity different from the Talbot longitudinally-periodic pattern common in grating interferometry. The curvature of the biprism array brings a sharper longitudinal fringe pattern. Experiments are being performed to verify the analytical calculations for a biprism plastic material of SU-8 using a synchrotron source. X-ray biprism material has widely varied indexes of refraction relative to wavelength and thus the separation of the virtual sources and resulting interference fringe period also varies with X-ray wavelength. Our aim is to develop biprism interferometry imaging systems with excellent polychromatic performance that produce high-contrast fringes with spatially incoherent X-ray illumination. Biprism interferometry will potentially provide higher fringe visibility with better image quality to that of diffraction grating interferometry.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Prototype Development for MBSE-Driven Digital Environment at Fermilab

Complex projects like Fermilab s accelerators and detectors involve thousands of interdependent components and requirements, making traditional documentation hard to keep consistent and often causing rework. Model-Based Systems Engineering (MBSE) tackles this by representing the system as a digital, queryable model. While widely used in aerospace and safety-critical industries, MBSE adoption has been limited elsewhere due to steep learning curves and high costs. This project investigates how a web-first, low-code MBSE stack can reduce those barriers and offer an accessible, unified source of truth for engineers and physicists.

Valle, Diego Pedro (ORCID:0009000865900663)↗

Cosmogenic 137 Xe Analysis of Alternatives for nEXO

Neutrinoless double-beta decay is a hypothetical nuclear decay in which two matter particles are produced without corresponding antimatter particles. Observation of neutrinoless double-beta decay would shed light on a potential explanation of matter-antimatter observed in the universe and also indicate the Majorana nature of neutrinos, meaning that the neutrino can act as its own antiparticle. The nEXO experiment is a proposed 5-ton liquid xenon time projection chamber detector with a projected 1.35 × 10 28 yr half-life sensitivity to neutrinoless double-beta decay in 136 Xe [J. Phys. G 49, 015104 (2022)]. While nEXO has a baseline location of SNOLAB, there are several other underground facilities in the world capable of hosting the experiment. The primary change at each site will be cosmogenic 137 Xe backgrounds, caused by varied cosmogenic muon activity at each site. This study finds that while there is a negligible increase in nEXO’s half-life sensitivity at 90% C.L. from improving the cosmogenic 137 Xe veto rejection procedure for SNOLAB, much higher daily muon rates at three other sites will have an adversely negative effect on nEXO’s sensitivity and would likely require further modifications to nEXO’s baseline design to reach nEXO’s scientific goals. Monte Carlo simulations of muons inducing 137 Xe backgrounds were conducted at four underground sites, SNOLAB, SURF, LNGS, and WIPP, each with roughly a factor of 10 times higher daily muon activity than the previous site. There were two primary inputs to these simulations. The first was sample data of cosmogenic muon flight through nEXO’s outer detector, a 12.8m tall and 12.3m wide cylindrical water tank lined with photomultiplier tubes to detect Cerenkov radiation, and all of the secondary interactions produced in the detector. The second input was a parametrization of 137 Xe* production tagging when 137 Xe de-excites and release prompt gammas, as well as accidental tagging caused by neutron capture on 63 Cu, 65 Cu, 19 F, and 1 H throughout the detector. Together, the number of backgrounds relative to the previous 2021 Sensitivity Paper [J. Phys. G 49, 015104 (2022)] was found at each of these four sites across three energy windows, from 400, 1400, and 2600 keV all up to 4600 keV, just above the end point of the prompt gamma spectrum for 137 Xe*. Using level curves for the sensitivity as 137 Xe backgrounds scale relative to baseline calculations, the half-life sensitivity at 90% C.L. for each of trial was found. Even with reduced 137 Xe backgrounds, the results for SNOLAB yielded neglible improvements in nEXO’s predicted sensitivity. On the contrary, the increased backgrounds for the three other considered sites yielded sensitivity estimates below nEXO’s previous projections. This study demonstrates that the shielding from cosmogenic muons at SNOLAB makes it highly preferred even amongst other world leading underground laboratories.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

CMS Outer Tracker Module QA

The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.

Hobbeheydar, Samuel [Fermilab; Carnegie Mellon U. ↗

CMS Outer Tracker Module QA

The High Luminosity Large Hadron Collider is a planned upgrade to the LHC that will allow it to take up to 7 times as much data. Upgrades to all detector systems, including the Outer Tracker, are necessary to allow them to handle the increased radiation and pileup. Fermilab has been tasked with assembling modules for the Outer Tracker system. This presentation discusses the QA tests performed on these modules and the integration procedure required to ensure all modules work in sync. The QA tests include sensor IV curves, MaPSA testing, visual inspection, skeleton testing, and module testing. There are additional tests that can only be performed on integrated modules that are working in sync, and developing an understanding of the timing and latency of the modules is necessary to perform this synchronization.

Hobbeheydar, Samuel [Fermilab; Carnegie Mellon U. ↗

PMT calibration for the JSNS^2-II far detector with an embedded LED system

The JSNS^2-II (the second phase of JSNS^2, J-PARC Sterile Neutrino Search at J-PARC Spallation Neutron Source) is an experiment aimed at searching for sterile neutrinos. Here, this experiment has entered its second phase, employing two liquid scintillator detectors located at near and far positions from the neutrino source. Recently, the far detector of the experiment has been completed and is currently in the calibration phase. The following properties of all functioning Photo-Multiplier-Tubes (PMTs) to detect the neutrino events in the far detector have been calibrated: PMT gain, its dependence of supplied High Voltage (HV), Peak-to-Valley (PV), and signal timing. This paper presents a detailed description of the calibration process utilizing the LED system. The LED system of the far detector uses two Ultra-Violet (UV) LEDs, which are effective in calibrating all of the PMTs at once. The UV light is converted into the visible light wavelengths inside liquid scintillator via the wavelength shifters, providing pseudo-isotropic light. To achieve a good energy resolution for physics events, a relative gain adjustment of up to 10% is required for all functioning PMTs. This will be achieved using the HV curves measured and the results of the LED calibration. The Peak-to-Valley (PV) ratio values, which distinguish the single photo-electron signal from the pedestal, are similar to those from the production company. Additionally, the precision of the PMT signal timing is measured to be 2.1 ns. This meets the event reconstruction requirement of 10 ns.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

Characterization of Amplification Properties of the Superconducting-Ferromagnetic Transistor

Here we report on the measurement results of the superconducting-ferromagnetic transistors (SFTs). The devices were made at Northwestern University and Hypres (SeeQC), Inc. (Nevirkovets et al., 2014; 2015). SFT is a multiterminal device with the SIS'FIFS (or SFIFS'IS) structure (where S, I, and F denote a superconductor, an insulator, and a ferromagnetic material, respectively) exploiting intense quasiparticle injection in order to modify the nonlinear I-V curve of a superconducting tunnel junction. SFT is capable of providing voltage, current, and power amplification while having good input/output isolation. We characterized the devices using different measurement techniques. We measured S parameters of the single- and double-acceptor devices at frequencies up to 5 MHz. Importantly, we confirmed that the isolation between the input and output of the device is quite good. However, the techniques typically employed to characterize semiconductor devices do not allow for revealing the full potential of our low-resistive SFT devices, especially those having two acceptors. In the latter case, we also tested the devices using the battery-powered current sources with floating grounds. Analyzing double-acceptor I-V curves recorded at different levels of injection currents, for an optimal load, we deduced a small-signal voltage gain of 33 and a power gain of 2.4. We suggest that further improvement of the SFT device parameters is possible in optimized devices, so that the device potentially may serve as a preamplifier for readout of output signals of cryogenic detectors and be useful as an element of other superconductor-based circuits. In addition, we used scanning transmission electron microscopy to identify some problems in the fabrication of the devices without any planarization.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Tidal Stripping of a White Dwarf by an Intermediate-mass Black Hole

During the inspiralling of a white dwarf (WD) into an intermediate-mass black hole (~10 2-5 M ⊙ ), both gravitational waves (GWs) and electromagnetic (EM) radiation are emitted. Once the eccentric orbit's pericenter radius approaches the tidal radius, the WD would be tidally stripped upon each pericenter passage. The accretion of this stripped mass would produce EM radiation. It is suspected that the recently discovered new types of transients, namely the quasiperiodic eruptions and the fast ultraluminous x-ray bursts, might originate from such systems. Modeling these flares requires a prediction of the amount of stripped mass from the WD and the details of the mass supply to the accretion disk. We run hydrodynamical simulations to study the orbital parameter dependence of the stripped mass. We find that our results match the analytical estimate that the stripped mass is proportional to z 5/2 , where z is the excess depth by which the WD overfills its instantaneous Roche lobe at the pericenter. The corresponding fallback rate of the stripped mass is calculated, which may be useful in interpreting the individual flaring light curve in candidate EM sources. We further calculate the long-term mass-loss evolution of a WD during its inspiral and the detectability of the GW and EM signals. The EM signal from the mass-loss stage can be easily detected: the limiting distance is ~320(M h /10 4 M ⊙ ) Mpc for the Einstein Probe. The GW signal, for space-borne detectors such as Laser Interferometer Space Antenna or TianQin, can be detected only within the Local Supercluster (~33 Mpc).

79 ASTRONOMY AND ASTROPHYSICS↗

Ultra low background time projection alpha particle detector ( Phase II Final Scientific/Technical Report)

When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Challenges Ahead for Multimessenger Analyses of Gravitational Waves and Kilonova: A Case Study on GW190425

In recent years, there have been significant advances in multimessenger astronomy due to the discovery of the first, and so far only confirmed, gravitational wave event with a simultaneous electromagnetic (EM) counterpart, as well as improvements in numerical simulations, gravitational wave (GW) detectors, and transient astronomy. This has led to the exciting possibility of performing joint analyses of the GW and EM data, providing additional constraints on fundamental properties of the binary progenitor and merger remnant. Here, in this work, we present a new Bayesian framework that allows inference of these properties, while taking into account the systematic modeling uncertainties that arise when mapping from GW binary progenitor properties to photometric light curves. We extend the relative binning method presented in Zackay et al. to include extrinsic GW parameters for fast analysis of the GW signal. The focus of our EM framework is on light curves arising from r-process nucleosynthesis in the ejected material during and after merger, the so-called kilonova, and particularly on black hole–neutron star systems. As a case study, we examine the recent detection of GW190425, where the primary object is consistent with being either a black hole or a neutron star. We show quantitatively how improved mapping between binary progenitor and outflow properties, and/or an increase in EM data quantity and quality are required in order to break degeneracies in the fundamental source parameters.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of the response of radiochromic film to quasi-monoenergetic x rays through a cross-calibration with image plates

Radiochromic film (RCF) and image plates (IPs) are both commonly used detectors in diagnostics fielded at inertial confinement fusion (ICF) and high-energy-density physics (HEDP) research facilities. Due to the intense x-ray background in all ICF/HEDP experiments, accurately calibrating the optical density of RCF as a function of x-ray dose, and the photostimulated luminescence per photon of IPs as a function of x-ray energy, is necessary for interpreting experimental results. Various measurements of the sensitivity curve of different IPs to x rays have been performed [Izumi et al., Proc. SPIE 8850, 885006 (2013) and Rosenberg et al., Rev. Sci. Instrum. 90(1), 013506 (2019)]; however, calibrating RCF is a tedious process that depends on factors such as the orientation in which the RCF is scanned in the film scanner and the batch of RCF used. These issues can be mitigated by cross-calibrating RCF with IPs to enable the use of IPs for the determination of dose on the RCF without scanning the RCF. Here, the first cross-calibration of RCF with IPs to quasi-monoenergetic titanium, copper, and molybdenum K-line x rays is presented. It is found that the IP-inferred dose rates on the RCF for the Ti and Mo x rays agree well with the measured dose rates, while the IP-inferred dose rate for the Cu x rays is larger than the measured dose rate by ∼2×. Explanations for this discrepancy and plans for future work are discussed.

Instruments & Instrumentation↗

Preliminary Design of a New Pulsed-Neutron Die--Away Experiments with Absorbers (IER-552 CED-1)

This report presents the preliminary design (CED-1) of IER-552, pulsed-neutron die-away (PNDA) experiments with absorbers, to be conducted by Lawrence Livermore National Laboratory (LLNL). The goal of the PNDA experiments with absorbing materials is to produce high-quality, low-cost integral benchmarks that can be used to validate cross sections that are high priority nuclear data for the Department of Energy’s Nuclear Criticality Safety Program (NCSP). PNDA experiments can be used to generate nuclear data validation benchmarks quickly and cheaply, as they do not require fissile material or a nuclear facility to conduct them. The original PNDA experiments were set up at LLNL under IER-501. Extending the PNDA experiments to include absorbing materials leverages existing facilities and resources at LLNL to validate cross sections, with a basic experiment design that uses a neutron generator to impinge a short, mono-energetic neutron pulse on a poisoned, moderating target sample. The neutron pulse lasts 100 µs, after which the neutron population in the sample reaches thermal equilibrium and later spatial equilibrium. In this fully equilibrized state, the neutron population has a characteristic decay-time eigenvalue. The eigenvalue can be used as an integral parameter to validate nuclear data involved with neutron scattering and absorption. Two observables can be measured: the neutron population and the population of secondary γ-rays produced by inelastic and capture reactions. This report explores the feasibility of both approaches. For γ-ray measurements, this allows for direct measurement of reactions of interest for validation. During the neutron burst time, inelastic (prompt) γ-rays dominate, and these data can be isolated for validation of neutron inelastic scattering data. After the pulse ends, neutron capture (delayed) γ-rays dominate and are produced by many reaction channels as neutrons slow down to thermal energies. Two sets of γ-ray spectra (inelastic, capture) can be produced for validation. Additionally, the time-dependent decay of the capture γ-ray population when the neutron population is thermalized and in its fundamental mode can be used for validation. Two experiments can be imagined where pulsed neutrons are used to validate the nuclear data of absorbing materials. The first integrates well into the existing PNDA testbed at LLNL. The absorber material would be introduced into a moderating target and the same neutron generator, neutron detectors, electronics, and shielding box used for IER-501 would be employed. From the same experimental setup, many absorbing materials can be validated by simply changing the neutron poison in the moderator. The only significant modification would be the introduction of a γ-ray detector. Such an experiment would primarily serve to validate nuclear data in the thermal energy range. The second kind of experiment would validate the fast and epithermal energy range. It would involve pulsing neutron into a bare assembly of the absorber material and measuring the die-away of neutrons. The fast leakage of such an assembly requires nanosecond neutron-generator pulse widths and fast detectors/electronics that could measure ~200 ns die-away curves. This kind of experiment would ideally be performed at a cyclotron, like that available at Lawrence Berkeley National Laboratory.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization and Optimization of Skipper CCDs for the SOAR Integral Field Spectrograph

We present results from the characterization and optimization of Skipper charge-coupled devices (CCDs) for use in a focal plane prototype for the Southern Astrophysical Research Integral Field Spectrograph (SIFS). We tested eight Skipper CCDs and selected six for SIFS based on performance results. The Skipper CCDs are 6k × 1k, 15 μm pixels, thick, fully depleted, p-channel devices that have been thinned to ~250 μm, backside processed, and treated with an anti-reflective coating. We demonstrate a single-sample readout noise of <4.3 e - rms pixel -1 in all amplifiers. We optimize the readout sequence timing to achieve a readout noise of 0.5 e - rms pixel -1 after 74 non-destructive measurements, which can be accomplished in a region covering 5% of the detector area in a readout time of <4 minutes. We demonstrate single-photon-counting in all 24 amplifiers (four amplifiers per detector) with a readnoise of σ N ~ 0.18 e - rms pixel -1 after N samp = 400 samples, and we constrain the degree of nonlinearity to be ≲1% at low signal levels (0 e - to 50 e - ). Clock-induced charge (CIC) remains an important issue when the Skipper CCD is configured to provide a large full-well capacity. We achieve a CIC rate of <1.45 × 10 -3 e - pixel -1 frame -1 for a full-well capacity of ~900 e - , which increases to a CIC rate of ~3 e - pixel -1 frame -1 for full-well capacities ~40,000-65,000 e - . We also perform conventional CCD characterization measurements such as charge transfer inefficiency (3.44 × 10 -7 on average), dark current (~2 × 10 -4 e - pixel -1 s -1 ), photon transfer curves, cosmetic defects (<0.45% “bad” pixels), and charge diffusion (point-spread function < 7.5 μm) to verify that these properties are consistent with expectations from conventional p-channel CCDs used for astronomy. Furthermore, we provide the first measurements of the brighter-fatter effect and absolute quantum efficiency (≳80% between 450 and 980 nm; ≳90% between 600 and 900 nm) using Skipper CCDs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗