Search NASA⌕ Search

SEARCH · Search NASA

Results for “Cyber Range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Design and Development of a High Fidelity Cyber-Physical Testbed

In order to ensure that future critical infrastructure systems are resilient to various types of such advanced and persistent threats, it is important to develop and integrate tailored solutions that holistically address cyber-attack detection and mitigation in a timely manner such that adverse system impacts that impact a large population are avoided. Further, it is essential to create environments that allow control, protection and communication to exist within a realistic environment to analyze the effects of adverse conditions and system operating modes. This project aims to establish a high-fidelity testbed environment for modeling and simulating a single microgrid all the way up to a network of microgrids along with baseline controls, protection, and associated cyber communication. This is an important activity because accurately modeling and simulating the various power-electronics-based DERs and loads in a microgrid is critical to adequately capturing their behaviors over a wide range of off-normal conditions, as well as to evaluate the resilience of the system using the developed controls. The work presented in this report focuses on the process of building this high-fidelity testbed and the associated experimentation it enables. The model enables the creation of high-fidelity use cases and associated datasets that have been used extensively within the initiative to study resilience and support novel control development and prototyping. The work heavily leverages existing capability that is part of the high-fidelity cyber-physical system experimentation lab to create a power hardware-in-the-loop setup. The report also details the creation of an automated model building platform that can enable high-fidelity real-time models to be built without much effort allowing existing low-fidelity models to be analyzed in higher fidelity. Lastly, the report also discusses efforts center around scaling to large complex power system models to make the experimentation more effective.

97 MATHEMATICS AND COMPUTING↗

Quantifying Uncertainty to Improve Decision Making in Machine Learning

Data-driven modeling, including machine learning methods, continue to play an increasing role in society. Data-driven methods impact decision making for applications ranging from everyday determinations about which news people see and control of self-driving cars to high-consequence national security situations related to cyber security and analysis of nuclear weapons reliability. Although modern machine learning methods have made great strides in model induction and show excellent performance in a broad variety of complex domains, uncertainty remains an inherent aspect of any data-driven model. In this report, we provide an update to the preliminary results on uncertainty quantification for machine learning presented in SAND2017-6776. Specifically, we improve upon the general problem definition and expand upon the experiments conducted for the earlier re- port. Most importantly, we summarize key lessons learned about how and when uncertainty quantification can inform decision making and provide valuable insights into the quality of learned models and potential improvements to them.

97 MATHEMATICS AND COMPUTING↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Cybersecurity Attacks in Vehicular Sensors

Today's modern vehicles contain anywhere from sixty to one-hundred sensors and exhibit the characteristics of Cyber-Physical-Systems (CPS). There is a high degree of coupling, cohesiveness, and interactions among vehicle's CPS components (e.g., sensors, devices, systems, systems-of-systems) across sensing, communication, and control layers. Cyber-attacks in the sensing or communication layers can compromise the security of the control layer. This paper provides a detailed review of potential cyber threats related to the sensing layer. Notably, the focus is mainly towards two categories of sensors: vehicle dynamics sensors (e.g., Tire Pressure Monitoring Systems (TPMS), magnetic encoders, and inertial sensors) and environment sensors (e.g., Light Detection and Ranging (LiDAR), ultrasonic, camera, Radio Detection and Ranging (Radar) systems, and Global Positioning System (GPS) units). Furthermore, the paper also offers perspectives through existing countermeasures from literature and stresses the need for data-driven cybersecurity solutions.

97 MATHEMATICS AND COMPUTING↗

R2U2: Tool Overview

R2U2 (Realizable, Responsive, Unobtrusive Unit) is an extensible framework for runtime System HealthManagement (SHM) of cyber-physical systems. R2U2 can be run in hardware (e.g., FPGAs), or software; can monitorhardware, software, or a combination of the two; and can analyze a range of different types of system requirementsduring runtime. An R2U2 requirement is specified utilizing a hierarchical combination of building blocks: temporal formula runtime observers (in LTL or MTL), Bayesian networks, sensor filters, and Boolean testers. Importantly, the framework is extensible; it is designed to enable definitions of new building blocks in combination with the core structure. Originally deployed on Unmanned Aerial Systems (UAS), R2U2 is designed to run on a wide range of embedded platforms, from autonomous systems like rovers, satellites, and robots, to human-assistive ground systems and cockpits. R2U2 is named after the requirements it satisfies; while the exact requirements vary by platform and mission, the ability to formally reason about realizability, responsiveness, and unobtrusiveness is necessary for flight certifiability, safety-critical system assurance, and achievement of technology readiness levels for target systems. Realizability ensures that R2U2 is suficiently expressive to encapsulate meaningful runtime requirements while maintaining adaptability to run on different platforms, transition between different mission stages, and update quickly between missions. Responsiveness entails continuously monitoring the system under test, real-time reasoning, reporting intermediate status, and as-early-as-possible requirements evaluations. Unobtrusiveness ensures compliance with the crucial properties of the target architecture: functionality, certifiability, timing, tolerances, cost, or other constraints.

Rozier, Kristin Y.↗

Cybersecurity for Distributed Energy Resources: All Hazards Approach for Grid Modernization

Distributed energy resources (DER) sit at the intersection of IoT and critical infrastructure. As we work towards clean energy and decarbonization targets, high rates of growth of DER are expected, making them an important component of generation and grid services. They have been a part of the explosion of internet connected devices developed to solve real-world problems and make life easier by providing clean, local energy and enable the smart management of grid services. However, the quick-to-market, low-cost drivers for DER, combined with a historically relative low-impact has meant that cybersecurity has not been a top priority. So as DER penetration increases, will DER be a part of the growing challenge of securing the grid, or part of the solution for necessary grid modernization? In this talk, we will discuss the factors that have led to our current position and what makes cybersecurity for DER unique. A wide range of research is conducted at national labs, in partnership with industry and academia, to inform everything from standards and regulation, to the development of cyber-physical anomaly detection through use of digital twins, and even advanced threat analytics to SBOM and HBOM tracking. Even with this multi-faceted approach to the challenges, the question remains: is this too little too late or are we doing enough to secure the grid for the next 30 years?

14 SOLAR ENERGY↗

Securing Vehicle Charging Infrastructure

As the US electrifies the transportation sector, cyber attacks targeting vehicle charging could bring consequences to electrical system infrastructure. This is a growing area of concern as charging stations increase power delivery and must communicate to a range of entities to authorize charging, sequence the charging process, and manage load (grid operators, vehicles, OEM vendors, charging network operators, etc.). The research challenges are numerous and are complicated because there are many end users, stakeholders, and software and equipment vendors interests involved. Poorly implemented electric vehicle supply equipment (EVSE), electric vehicle (EV), or grid communication system cybersecurity could be a significant risk to EV adoption because the political, social, and financial impact of cyberattacks - or public perception of such - ripples across the industry and has lasting and devastating effects. Unfortunately, there is no comprehensive EVSE cybersecurity approach and limited best practices have been adopted by the EV/EVSE industry. There is an incomplete industry understanding of the attack surface, interconnected assets, and unsecured interfaces. Thus, comprehensive cybersecurity recommendations founded on sound research are necessary to secure EV charging infrastructure. This project is providing the power, security, and automotive industry with a strong technical basis for securing this infrastructure by developing threat models, determining technology gaps, and identifying or developing effective countermeasures. Specifically, the team is creating a cybersecurity threat model and performing a technical risk assessment of EVSE assets, so that automotive, charging, and utility stakeholders can better protect customers, vehicles, and power systems in the face of new cyber threats.

33 ADVANCED PROPULSION SYSTEMS↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

97 MATHEMATICS AND COMPUTING↗

Systems and methods for detecting and mitigating cyber attacks on power systems comprising distributed energy resources

Extensive deployment of interoperable distributed energy resources (DER) on power systems is increasing the power system cybersecurity attack surface. National and jurisdictional interconnection standards require DER to include a range of autonomous and commanded grid-support functions which can drastically influence power quality, voltage, and the generation-load balance. Investigations of the impact to the power system in scenarios where communications and operations of DER are controlled by an adversary show that each grid-support function exposes the power system to distinct types and magnitudes of risk. The invention provides methods for minimizing the risks to distribution and transmission systems using an engineered control system which detects and mitigates unsafe control commands.

Johnson, Jay Tillay↗

Bracknell Meteorological Office

The Bracknell (U.K.) Meteorological Office runs a global weather model twice a day, providing the following data: surface and radiosonde; aircraft reports; and satellite soundings and wind. A human forecast is made every six hours. The model runs on a 150 km grid with 15 levels, and takes about four minutes on a Cyber-205. The standard output from the global products are wind, temperature, height, tropopause, and maximum wind. Various experiments have been conducted to see if short-range forecasters could improve on the upper-wind forecasts over the numerical model; the numerical model remains of paramount importance. Small-scale models are being run in the U.S. and the U.K. A fine-mesh model covers Europe and the Atlantic. A mesoscale model is under development. A great deal of verification work is done to see how good the models are.

Flood, Colin R.↗

Impact of DER Communication Delay in AGC: Cyber-Physical Dynamic Co-Simulation: Preprint

Distributed energy resource (DER) frequency regulations are promising technologies for future grid operation. Unlike conventional generators, DERs might require open communication networks to exchange signals with control centers, possibly through DER aggregators; therefore, the impacts of the communication variations including the latency on the system frequency stability need to be investigated. This paper develops a cyber-physical dynamic simulation (CPDS) model based on the Hierarchical Engine for Large-Scale Co-Simulation (HELICS) to evaluate the impact of the communication variations, such as delays in DER frequency regulations. The feasible delay range can be obtained under different AGC parameter settings. The results show that the risk of instability generally increases with the communication delay and that the difference of AGC provided from DER and conventional generation units should be recognized when designing frequency regulation controllers.

61 RADIATION PROTECTION AND DOSIMETRY↗

Using Discrete Event Simulation to Model Attacker Interactions with Cyber and Physical Security Systems

The number of connections between physical and cyber security systems is rapidly increasing due to centralized control from automated and remotely connected means. As the number of interfaces between systems continues to grow, the interactions and interdependencies between them cannot be ignored. Historically, physical and cyber vulnerability assessments have been performed independently. This independent evaluation omits important aspects of the integrated system, where the impacts resulting from malicious or opportunistic attacks are not easily known or understood. Here, we describe a discrete event simulation model that uses information about integrated physical and cyber security systems, attacker characteristics and simple response rules to identify key safeguards that limit an attacker's likelihood of success. Key features of the proposed model include comprehensive data generation to support a variety of sophisticated analyses, and full parameterization of safeguard performance characteristics and attacker behaviours to evaluate a range of scenarios. Lastly, we also describe the core data requirements and the network of networks that serves as the underlying simulation structure.

97 MATHEMATICS AND COMPUTING↗

The seasonal-cycle climate model

The seasonal cycle run which will become the control run for the comparison with runs utilizing codes and parameterizations developed by outside investigators is discussed. The climate model currently exists in two parallel versions: one running on the Amdahl and the other running on the CYBER 203. These two versions are as nearly identical as machine capability and the requirement for high speed performance will allow. Developmental changes are made on the Amdahl/CMS version for ease of testing and rapidity of turnaround. The changes are subsequently incorporated into the CYBER 203 version using vectorization techniques where speed improvement can be realized. The 400 day seasonal cycle run serves as a control run for both medium and long range climate forecasts alsensitivity studies.

Marx, L.↗

Spectral General Circulation Model Development

A spectral general circulation model was developed to run on the Cyber 205 computer system installed at the NASA Goddard Space Flight Center. This model should enhance the utility of satellite-based observation systems for accurate long-range weather prediction.

Orszag, S. A.↗

Securing Distributed Energy Resource Integration

The penetration of distributed energy resources (DER) is growing at much higher rates than predicted 20 years ago. Far from being used only in residential settings, DER are now installed on distribution and transmission circuits. In this position, they do not have the same properties as traditional generators and are more flexible in many cases. The growing penetration and range of uses for DER motivate the need to reliably and safely integrate them into the grid. Operators must be able to rely on them not only for normal operation, but also during abnormal conditions like black starts or adverse cyber scenarios. To that end, we study the communications, device interfaces, and potential consequences of DER operation under abnormal and adversarial conditions. The weaknesses of communications networks are studied based on the industrial protocols used, and the benefits of security features are examined. The device interfaces are found to be vulnerable to attack based on the requirements in the IEEE-1547 standard for DER interconnection and interoperability, which is expected to be adopted in the next ten years. In addition to exploring the requirements of the standard, we show that these vulnerabilities and others do exist and can be used maliciously in a modern storage system DER. Consequences of these vulnerabilities range from exacerbated grid instability, to simultaneous loss of large portions of DER penetration, to physical damage to inverters or DER themselves and other sensitive equipment. We tie these outcomes to specific attacker actions in an effort to give operators a better threat intelligence view that allows them to prioritize mitigations. Finally, we discuss mitigations that could prevent many of the adversarial scenarios described. Some solutions can be added to existing infrastructure, while others may require longer term planning for grid modernization with consideration for security.

25 ENERGY STORAGE↗

Complete viscous flowfield solutions about a blunt parabolic body in a supersonic stream

A hybrid computational technique which splits the flowfield into inviscid and viscous regions is used to investigate the complete flowfield about axisymmetric parabolic blunt bodies in a supersonic stream. The solutions are carried out on the CDC CYBER-203 computer which, with its extensive memory, allows for the use of a large number of finite-difference mesh points, allowing resolution of important flowfield features. A range of freestream Mach number of 2-5 and a range of Re number based on nose radius of 500-125,000 was run for a sonic corner body. Contour plots of density, pressure, and Mach number, velocity vector plots, and surface distributions of pressure, heat transfer, and shear stress are presented. Also, correlations of the downstream extent of the base recirculation region with Re number based on nose radius are given.

Weilmuenster, K. J.↗

A real-time multiphysics model of a pressurized solid oxide electrolysis cell (SOEC) for cyber-physical simulation

Solid oxide electrolysis cells (SOEC) can play important roles in integrated energy systems (IES) as the hydrogen production hub and the resilience energy hub. When tied to a microgrid with high renewable penetration, the SOEC is subjected to rapid load transitions in response to the intermittent renewable generations that occur not only in diurnal cycles but also in short timeframes (e.g., sub-minute). The cyber-physical simulation approach can derisk operability research but requires a real-time dynamic SOEC model. In the present work, a real-time multiphysics model for pressurized SOEC is developed and validated in the pressure range from 1.4 to 8bar. Further, the accuracy of the single repeating unit (SRU) assumption in SOEC stack simulation is quantified. A guidance of more than 45 cells in one SOEC stack is recommended to safely apply the SRU assumption. Modeling results suggest that at a given current density, more power is consumed by SOEC at elevated operating pressures. The anode air and cathode stream have major impacts on thermal management, highlighting the potential benefit of integrating SOEC with other thermal processes in IES. To achieve high hydrogen production efficiency, the SOEC could operate at the maximum endothermic point to maximize the use of thermal energy. The real-time execution of the developed SOEC model is also demonstrated, which only takes 0.1% of the fixed time step of 5ms. The developed model establishes the basis for cyber-physical simulation of SOEC hybrid systems.

25 ENERGY STORAGE↗

TrojAI Alternate Analysis

In this portion of the TrojAI evaluation, we focus on the cyber-network-c2-mar2024 dataset. Recall that in this round ResNet18 and ResNet34 neural networks (NN) were trained on the USTC-TFC2016 dataset with the aim of distinguishing between benign versus botnet command and control (c2) packets. A range of bytes from each packet was reformatted into a 28x28 pixel image, and the collection of reformatted packets served as the training (and testing) data for the two ResNet models. For some of the data a trigger watermark was strategically placed to affect various inputs to the NNs. This watermarked, or poisoned, data in turn created a poisoned, or trojaned NN. The data were poisoned in different ways ultimately creating different trojaned NNs. This collection of trojaned NNs was combined with various versions of not trojaned NNs and served as the training and testing data for the performers. The performers’ task was to construct a classifier to distinguish between the trojaned and not trojaned models. It was previously noted that the performers struggled with the cyber-network-c2-mar2024 dataset, motivating this investigation of potential reasons the performers experienced challenges.

97 MATHEMATICS AND COMPUTING↗