Search NASA⌕ Search

SEARCH · Search NASA

Results for “DAMPER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

BNL 56 MHz HOM damper prototype fabrication at JLAB

A prototype Higher-Order Mode (HOM) Damper was fabricated at JLab for the Relativistic Heavy-Ion Collider’s (RHIC) 56 MHz cavity at Brookhaven National Laboratory (BNL). Primarily constructed from high RRR Niobium and Sapphire, the coaxial damper presented significant challenges in electron-beam welding (EBW), brazing and machining via acid etching. The results of the prototype operation brought about changes in the damper design, due to overheating braze alloys and possible multi-pacting. Five production HOM dampers are currently being fabricated at JLab. This paper outlines the challenges faced in the fabrication process, and the solutions put in place.

43 PARTICLE ACCELERATORS↗

Assessing the Impact of Variable Air Volume Box Damper Stuck Faults Using a Building Automation System and Building Energy Simulation Model

The study examines the impact of variable air volume (VAV) damper stuck faults on the system operation, building indoor conditions, and reheating energy consumption. This study includes both experimental and simulation studies for five test scenarios, including a fault-free scenario. We implemented VAV damper stuck fault through the building automation system (BAS). Results show that a damper stuck in a high opening position (60% damper opening) results in supplying an excessive amount of cold air from the rooftop unit (RTU) to the conditioned zone, increasing reheating energy consumption. The results of this research can serve as a foundational resource for developing fault detection algorithms.

Jung, Sungkyun↗

Special Fluid Viscous Dampers For The Messina Strait Bridge

The Messina Strait Bridge would be the world's longest suspension bridge, with a design earthquake characterised by a PGA value of 0.58 g and a distance between the ipocenter and the bridge of 15 km. Said critical structure of course would need a suitable restraint system for traffic braking loads, wind and seismic actions. Each type of load requires a specific behaviour of the restraint system, making its design a big challenge.The restraint system comprises special types of fluid viscous dampers, installed both in longitudinal and transverse direction, both at the towers and at the anchorages. In seismic conditions they behave as viscous dampers, to reduce the forces on the structural elements and the movements of the bridge deck. But in service dynamic conditions, e.g. under traffic or wind load, the devices shall behave like shock transmission units, thus preventing the longitudinal and transverse movements of the deck.FIP Industriale cooperated with the selected General Contractor, a consortium lead by Impregilo, in the design of said viscous dampers. This paper describes the main features of said devices.

58 GEOSCIENCES↗

Semiactive Control Using MR Dampers of a Frame Structure under Seismic Excitation

The paper approaches the multifaceted task of semiactively controlling the seismic response of a prototypal building model, through interstorey bracings embedding magnetorheological dampers. The control strategy is based on a synthetic discrete model, purposely formulated in a reduced space of significant dynamic variables, and consistently updated to match the modal properties identified from the experimental response of the modeled physical structure. The occurrence of a known eccentricity in the mass distribution, breaking the structural symmetry, is also considered. The dissipative action of two magnetorheological dampers is governed by a clipped-optimal control strategy. The dampers are positioned in order to deliver two eccentric and independent forces, acting on the first-storey displacements. This set-up allows the mitigation of the three-dimensional motion arising when monodirectional ground motion is imposed on the non-symmetric structure. Numerical investigations on the model response to natural accelerograms are presented. The effectiveness of the control strategy is discussed through synthetic performance indexes.

58 GEOSCIENCES↗

Bifurcations and chaos of a vibration isolation system with magneto-rheological damper

Magneto-rheological (MR) damper possesses inherent hysteretic characteristics. We investigate the resulting nonlinear behaviors of a two degree-of-freedom (2-DoF) MR vibration isolation system under harmonic external excitation. A MR damper is identified by employing the modified Bouc-wen hysteresis model. By numerical simulation, we characterize the nonlinear dynamic evolution of period-doubling, saddle node bifurcating and inverse period-doubling using bifurcation diagrams of variations in frequency with a fixed amplitude of the harmonic excitation. The strength of chaos is determined by the Lyapunov exponent (LE) spectrum. Semi-physical experiment on the 2-DoF MR vibration isolation system is proposed. We trace the time history and phase trajectory under certain values of frequency of the harmonic excitation to verify the nonlinear dynamical evolution of period-doubling bifurcations to chaos. The largest LEs computed with the experimental data are also presented, confirming the chaotic motion in the experiment. We validate the chaotic motion caused by the hysteresis of the MR damper, and show the transitions between distinct regimes of stable motion and chaotic motion of the 2-DoF MR vibration isolation system for variations in frequency of external excitation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Higher Order Mode Damper Study of the 56 MHz SRF Cavity

This report summarizes the study on the higher order mode (HOM) damper for the 56 MHz SRF cavity. The Q factors and frequencies of the HOMs with the HOM damper are measured and compared to the simulation. The high pass filter prototype for rejecting the fundamental mode is designed and tested. The filter measurement is also compared to the simulation. Based on the measurement, a new location of the HOM damper is chosen.

43 PARTICLE ACCELERATORS↗

Dynamic behavior of the mercury damper

The dynamic behavior of the mercury nutation damper is investigated. Particular attention is paid to the eccentric annular mercury configuration, which is the final continuous ring phase that occurs in the operation of all mercury dampers. In this phase, damping is poorest, and the system is closely linear. During the investigation, the hydrodynamic problem is treated as three dimensional, and extensive use is made of a variational principle of least-viscous frictional power loss. A variational principle of least-constraint is also used to advantage. Formulas for calculating the behavior of the mercury damper are obtained. Some confirmatory experiments were performed with transparent ring channels on a laboratory gyroscope. Selected movie frames taken during wobble damping are shown along with the results of film measurements.

Crout, P. D.↗

Low nutation-rate dampers

Mission requirements plus spacecraft weight and power constraints often reduce the excitation frequency of a nutation damper below 1 cpm. Since attitude stability is determined by damper performance, maximum effectiveness at low rates is demanded. Presented are design considerations that low-frequency dampers require, along with descriptions of two low-frequency systems: the Direct Measurement Explorer 1 and the Small Astronomy Satellite A (SAS-A).

Tossman, B. E.↗

Some observed effects of part-span dampers on rotating blade row performance near design point

Detailed measured radial distributions of flow parameters for eight rotors with part-span dampers are used to study the effects of dampers on rotor performance and flow parameters at near design operation. All rotors had a blade tip diameter of about 20 in. and operated at a blade tip speed of about 1400 ft/sec. Several examples demonstrate that, when the local loss variations in the damper flow region are included in an aerodynamic design or analysis procedure, the computed spanwise distributions of flow parameters compare closely with measured distributions.

Esgar, G. M.↗

Nutation damper

A nutation damper for use on a spinning body is disclosed. The damper is positioned parallel to the spin axis of the body and radially displaced therefrom. The damper is partially filled with a fluid and contains a porous media to impede the flow of the fluid induced by nutation.

Evans, J.↗

Space Shuttle Damper System for Ground Wind Load Tests

An active damper system which was originally developed for a 5.5% Saturn IB/Skylab Ground Winds Model was modified and used for similar purposes in a Space Shuttle model. A second damper system which was originally used in a 3% Saturn V/Dry Workshop model was also modified and made compatible with the Space Shuttle model to serve as a back-up system. Included in this final report are descriptions of the modified damper systems and the associated control and instrumentation.

Robinson, G. D.↗

Effect of damper on overall and blade-element performance of a compressor rotor having a tip speed of 1151 feet per second and an aspect ratio of 3.6

The overall and blade-element performance of two configurations of a moderately high aspect ratio transonic compressor rotor are presented. The subject rotor has conventional blade dampers. The performance is compared with a rotor utilizing dual wire friction dampers. At design speed the subject achieved a pressure ratio of 1.52 and efficiency of 0.89 at a near design weight flow of 72.1 pounds per second. The rotor with wire dampers gave consistently higher pressure ratios at each speed, but efficiencies for the two rotors were about the same. Stall margin for the subject rotor was 20.4 percent, but for the wire damped rotor only 4.0 percent.

Lewis, G. W.↗

Design and application of squeeze film dampers for turbomachinery stabilization

The steady-state transient response of the squeeze film damper bearing was investigated. Both the steady-state and transient equations for the hydrodynamic bearing forces are derived; the steady-state equations were used to determine the damper equivalent stiffness and damping coefficients. These coefficients are used to find the damper configuration which will provide the optimum support characteristics based on a stability analysis of the rotor-bearing system. The effects of end seals and cavitated fluid film are included. The transient analysis of rotor-bearing systems was conducted by coupling the damping and rotor equations and integrating forward in time. The effects of unbalance, cavitation, and retainer springs are included. Methods of determining the stability of a rotor-bearing system under the influence of aerodynamic forces and internal shaft friction are discussed.

Gunter, E. J.↗

A damper for ground wind-induced launch vehicle oscillations

Prelaunch oscillatory bending deflections of the Atlas/Centaur launch vehicle are restrained by a damper mechanism mounted on the end of a horizontal boom supported from the umbilical tower. A single vertical pin on the vehicle engages the mechanism, and the damper is connected to the vehicle until liftoff. As the attach pin rises with the vehicle, a retractable arm mechanism provides initial clearance. An explosive release mechanism allows the boom to swing clear of the vehicle like a pendulum, while a snubber mechanism decelerates the free swinging boom and damper mechanism to a safe stop.

Bodle, J. G.↗

Correlation of part-span damper losses through transonic rotors operating near design point

The design-point losses caused by part-span dampers (PSD) were correlated for 21 transonic axial flow fan rotors that had tip speeds varying from 350 to 488 meters per second and design pressure ratios of 1.5 to 2.0. For these rotors a correlation using mean inlet Mach number at the damper location, along with relevant geometric and aerodynamic loading parameters, predicts the variation of total pressure loss coefficient in the region of the damper to a good approximation.

Roberts, W. B.↗

Shear dampers for deflections of micro-inch magnitudes

The rotation of the TV camera on the Mariner Jupiter/Saturn 1977 (MJS77) spacecraft will excite the long magnetometer and heavy RTG booms which are slightly damped perturbances that have long settling times. To ensure clear TV pictures additional damping was required over micro-inch displacements and at low frequencies. The solution incorporated elastomeric shear dampers at the base of these booms which possessed high loss tangent values in the expected frequency and temperature ranges. Presented are the shear damper design, results of full scale horizontal boom tests and relative effects of damper sizing and temperature. Boom instrumentation and excitation used for the full scale tests are also discussed.

Otth, D.↗

An active nutation damper for spacecraft

An active nutation damping device, consisting of an angular accelerometer, a dc motor driven flywheel, and associated electronics, was developed for spacecraft use. This damping system was used on the Lageos spacecraft, launched 4 May 1976, to control nutation buildup during the long coast period after the third stage separation. Of many electrical and mechanical design choices, an angular rather than linear accelerometer offered some advantages but problems developed in adapting the angular accelerometer to spacecraft use. The damper package was evaluated and proven on a three axis gas-bearing simulator that duplicated the Lageos spacecraft critical flight dynamics. A failure analysis of the damper assembly was performed. Performance of the damper during the Lageos flight has confirmed the preflight evaluation and analysis.

Abercrombie, R. A.↗

An active nutation damper for spacecraft

An active nutation damping device, consisting of an angular accelerometer, a dc-motor-driven flywheel, and associated electronics, developed for spacecraft use is described. This damping system was used on the LAGEOS spacecraft to control nutation buildup during the long coast period (approximately 75 minutes) after the third stage separation. The damper package was evaluated and proven on a three-axis gas-bearing simulator that duplicated the LAGEOS spacecraft critical flight dynamics. In addition, a failure analysis of the damper assembly was performed. Performance of the damper during the LAGEOS flight has confirmed the preflight evaluation and analysis.