Dynamically Reconfigurable Data Readout of Pixel Detectors for Automatic Synchronization with Data Acquisition Systems

Reconfigurable detectors with dynamically selectable sensing and readout modes are highly desirable for implementing edge computing as well as enabling advanced imaging techniques such as foveation. The concept of a camera system capable of simultaneous passive imaging and dynamic ranging in different regions of the detector is presented. Such an adaptive-autonomous detector with both spatial and temporal control requires programmable window of exposure (time frames), ability to switch between readout modes such as full-frame imaging and zero-suppressed data, modification of the number of pixel data bits and independent programmability for distinct detector regions. In this work, a method is presented for seamlessly changing time frames and readout modes without data corruption while still ensuring that the data acquisition system (DAQ) does not need to stop and resynchronize at each change of setting, thus avoiding significant dead time. Data throughput is maximized by using a minimum unique data format, rather than lengthy frame headers, to differentiate between consecutive frames. A data control and transmitter (DCT) synchronizes data transfer from the pixel to the periphery, reconfigures the data to transmit it serially off-chip, while providing optimized decision support based on a DAQ definable mode. Measurements on a test structure demonstrate that the DCT can operate at 1 GHz in a 65 nm LP CMOS process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Addition of transient kinetics capabilities to an infrared reflection absorption spectroscopy system through synchronized gas pulsing and data acquisition

Surface science methodologies for understanding thermodynamic aspects of surface processes are at an advanced level. However, instrumentation and approaches for extracting kinetic parameters from elementary steps are far less accessible. In this work, we present an approach combining the use of a fast gas pulsing valve synchronized with data acquisition to enable surface transient kinetics studies using infrared reflection absorption spectroscopy. This methodology applies to the study of reversible processes and borrows concepts and ideas from molecular beam scattering and temporal analysis of products. Here, a temporal resolution of ~67 ms is achieved, and this is illustrated through the study of CO adsorption and desorption on a Pd(111) crystal in the presence and absence of background O 2 . The same approach can be extended to other surface spectroscopies, such as X-ray photoelectron spectroscopy, to obtain spectra with high temporal resolution and signal-to-noise ratio and enable future multimodal surface transient kinetic studies aiming at elucidating reaction mechanisms.

36 MATERIALS SCIENCE↗

Influence of Data Acquisition Algorithms on X-ray Phase Contrast Imaging Computed Tomography

X-ray phase contrast imaging (XPCI) is a non-destructive evaluation technique that enables high-contrast detection of low-attenuation materials that are largely transparent in traditional radiography. Extending a grating based Talbot-Lau XPCI system to three- dimensional imaging with computed tomography (CT) imposes two motion requirements: the analyzer grating must translate transverse to the optical axis to capture image sets for XPCI reconstruction, and the sample must rotate to capture angular data for CT reconstruction. The acquisition algorithm choice determines the order of movement and positioning of the two stages. The choice of image acquisition algorithm for XPCI CT is instrumental to collecting high fidelity data for reconstruction. We investigate how data acquisition influences XPCI CT by comparing two simple data acquisition algorithms and determine that capturing a full phase-stepping image set for a CT projection before rotating the sample results in higher quality data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Calibration of a compact ASIC-based data acquisition system for neutron/$γ$ discrimination and spectroscopy with organic scintillators

Segmented neutron detectors that use silicon photomultipliers (SiPMs) are receiving significant attention in nuclear security applications. Some of these detectors employ hundreds of channels and would therefore benefit from the use of high-channel-density and low-cost-per-channel data acquisition (DAQ) systems. Candidate DAQ systems that meet these requirements exist, but few perform full waveform digitization, which permits neutron and gamma-ray interaction discrimination via pulse shape. In this work, we study the performance of the TOFPET2 (PETsys Electronics), an ASIC-based DAQ designed for positron emission tomography, which has been adapted to provide sensitivity to pulse shape by the use of variable-period charge integration. We use a light-emitting diode to calibrate a combination of an ON Semiconductor (SensL) 60035-64P J-Series SiPM and TOPFET2 DAQ and evaluate the linearity of their response and dynamic range. Here, the calibration curve was obtained by comparing the DAQ response to that measured with a photodiode interfaced with a traditional waveform digitizer. This calibration process was used for rudimentary spectroscopy of various neutron and sources.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Containerization of Phase-2 Tracker Data Acquisition and Control Framework

The CMS Experiment has started an extensive upgrade program in the context of the High-Luminosity phase of the LHC (Phase-2). In order to cope with the highly demanding High-Luminosity conditions, CMS will need a completely new inner and outer tracking detectors. On top of R&D development, a Data AcQuisition (DAQ) software is being developed along with different applications to control, monitor and validate the newly produced modules of the future tracker. As more and more developers are getting involved to maintain all those codes, an environment where software and applications can work independently of the host machine operating system is crucial. The Phase-2 Tracker group decided to make use of Docker as containerization solution for its framework. This poster describes the containerization of DAQ software/applications utilized to test and validate the Tracker modules. This includes continuous integration and continuous deployment (so-called CI/CD) and running GUI applications inside containers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Slow control and data acquisition development in the Mu2e experiment

The muon campus program at Fermilab includes the Mu2e experiment that will search for a charged-lepton flavor violating processes where a negative muon converts into an electron in the field of an aluminum nucleus, improving by four orders of magnitude the search sensitivity reached so far.Mu2e’s Trigger and Data Acquisition System (TDAQ) uses {\it otsdaq} solution. Developed at Fermilab, {\it otsdaq} uses the {\it artdaq} DAQ framework and {\it art} analysis framework, for event transfer, filtering, and processing.{\it otsdaq} is an online DAQ software suite with a focus on flexibility and scalability, and provides a multi-user interface accessible through a web browser.A Detector Control System (DCS) for monitoring, controlling, alarming, and archiving has been developed using the Experimental Physics and Industrial Control System (EPICS) open source Platform. The DCS System has also been integrated into {\it otsdaq}, providing a GUI multi-user, web-based control, and monitoring dashboard.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Residual Dose and Environmental Monitoring for the Fermilab Main Injector Tunnel Using the Data Acquisition Logging Engine (Dale)

The Recycler and the Main Injector are part of the Fermilab Accelerator complex used to deliver proton beam to the different experiments. It is very important to control and minimize losses in both machines during operation, to reduce personnel dose from residual activation and to preserve component lifetime. To minimize losses, we need to identify the loss points and adjust the components accordingly. The Data Acquisition Loss Engine (DALE) platform has been developed within the Main Injector department and upgraded throughout the years. DALE is used to survey the entire enclosure for residual dose rates and environmental readings when unrestricted access to the enclosure is possible. Currently DALE has two radiation meters, which are aligned along each machine, so loss points can be identified for both at the same time. DALE attaches to the enclosure carts and is continuously in motion monitoring dose rates and other environmental readings. In this paper we will describe how DALE is used to provide radiation maps of the residual dose rates in the enclosure. We will also compare the loss points with the Beam Loss monitor data.

43 PARTICLE ACCELERATORS↗

CONTROL AND DATA ACQUISITION IN A CYBER-PHYSICAL MIDSTREAM TESTBED

This thesis presents the development of a laboratory-scale cyber–physical midstream pipeline testbed designed to address this gap and support research in industrial control systems security. The platform integrates pumps, valves, sensors, programmable logic controllers (PLCs), and a human–machine interface (HMI) to emulate the monitoring and control architecture of real pipeline operations. The physical process is implemented as a closed-loop liquid circulation system designed to replicate flow behavior characteristic of midstream pipeline infrastructure. The testbed enables real-time data acquisition of key process variables, including flow rate and pressure facilitating the generation of datasets representative of normal pipeline operation. A threat model encompassing common ICS attack vectors was developed, including sensor spoofing, command injection, false data injection, denial-of-service attacks, and relay manipulation. Multiple attack scenarios were implemented and evaluated to demonstrate how cyber intrusions targeting sensors, actuators, networks, and software propagate into measurable physical consequences in pipeline flow and pressure. The developed platform serves as a practical, cost-effective environment for experimentation, education, and future cybersecurity research in midstream pipeline systems.

42 ENGINEERING↗

Time-tagging data acquisition system for testing superconducting electronics based on an RFSoC and custom analog frontend

Novel electronic devices can often be operated in a plethoraof ways, which makes testing circuits comprised of them difficult.Often, no single tool can simultaneously analyze the operatingmargins, maximum speed, and failure modes of a circuit, particularlywhen the intended behavior of subcomponents of the circuit is notstandardized. This work demonstrates a cost-effective time-domaindata acquisition system for electronic circuits that enables moreintricate verification techniques than are practical withconventional experimental setups. We use high-speeddigital-to-analog converters and real-timemulti-gigasample-per-second waveform processing to push experimentalcircuits beyond their maximum operating speed. Our customtime-tagging data capture firmware reduces memory requirements andcan be used to determine when errors occur. The firmware iscombined with a thermal-noise-limited analog frontend with50 dB of dynamic range. Compared to currentlyavailable commercial test equipment that is seven times moreexpensive, this data acquisition system was able to operate asuperconducting shift register at a nearly three-times-higher clockfrequency (200 MHz vs. 80 MHz).

Foster, Reed A. [MIT] (ORCID:0000000231002127)↗

Improved Beam Loss Accounting with Fast Data Acquisition (DAQ) Chassis

Identifying the source of beam loss events in the CE-BAF accelerator can be a challenging task. However, with our new prototype system, this task becomes more effi-cient. The system, developed in the fall of 2022, utilizes a dispersive beam position monitor (BPM) and the exist-ing switched electrode electronics BPM hardware. Previ-ously a commercial off-the-shelf data acquisition (DAQ) system was employed to capture BPM wire signals at a sample rate of 20 kS/s. The fast shutdown signal triggered the system, which disables the beam at the injector. Analysis of beam position and energy variation before a beam loss event was used to determine if the beam loss event was associated with an energy transient. The proto-type system, implemented using National Instruments hardware and LabVIEW® software, relied on a software trigger. Manual post-processing was required to ascertain whether the fault was due to an un-tripped cavity with a gradient or phase transient. This work focuses on deploying a Fast DAQ Chassis to monitor BPM hardware in real time and during beam loss events. This system was originally developed and in-stalled in CEBAF to monitor the time-domain RF control signals in the legacy analog RF systems. This technology was leveraged to also monitor BPM signals. As the new system employs a hardware trigger, developing tools to automatically identify faults linked to energy transients unrelated to cavity faults will be straightforward. This paper will discuss the project's initial updates, underlin-ing the crucial role of each member of our team in this achievement

Tiskumara, J.↗

Multi-Sensor Data Acquisition System for Process Monitoring

Idaho National Laboratory is building a new nuclear fuel cycle test bed. This fuel cycle test bed named “Beartooth” will give researchers the opportunity to study the nuclear fuel cycle process. The process operations include the use of centrifugal contactors and process flow for the purification of special nuclear material recovery in used fuel. This new research facility has the need to use non-traditional measurement sensors to determine the state-of-health of the solvent extraction process. These non-traditional sensors can also enhance nuclear nonproliferation supervision and other activities. The non-traditional sensors include accelerometers, acoustic, current, flow, colorimetric, temperature, pH and conductivity. The challenge behind deploying all these sensors, is the need for fast and reliable data collection. The data acquisition system (DAQ) needs to be capable of recording up to 12 accelerometers and/or acoustic microphones simultaneously at rates up to 12.8 kSamples/second/channel. This requires the need for a strong architecture and data collection solution. This summary identifies the system architecture, DAQ, and sensors needed to support non-traditional measurements in a solvent extraction process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Design and implementation of the AMIGA embedded system for data acquisition

The Auger Muon Infill Ground Array (AMIGA) is part of the AugerPrime upgrade of the Pierre Auger Observatory. It consists of particle counters buried 2.3 m underground next to the water-Cherenkov stations that form the 23.5 km 2 large infilled array. The reduced distance between detectors in this denser area allows the lowering of the energy threshold for primary cosmic ray reconstruction down to about 1017 eV. At the depth of 2.3 m the electromagnetic component of cosmic ray showers is almost entirely absorbed so that the buried scintillators provide an independent and direct measurement of the air showers muon content. This work describes the design and implementation of the AMIGA embedded system, which provides centralized control, data acquisition and environment monitoring to its detectors. The presented system was firstly tested in the engineering array phase ended in 2017, and lately selected as the final design to be installed in all new detectors of the production phase. The system was proven to be robust and reliable and has worked in a stable manner since its first deployment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Data Acquisition System Selection and Calibration of Resistive Moisture Content Measurements for Large-Scale Field Studies in Cold Climate Residential Building Envelope Performance

The residential building stock built before the energy codes were enforced has several significant inefficiency problems in terms of insulation and air leakage. To decrease these inefficiencies, building retrofits are necessary. However, if the envelope is not appropriately designed, excessive accumulation of moisture content and thus mold formation and decay inside the envelope layers can be a vital problem. This risk becomes higher, especially in extreme climate conditions such as cold winters and hot and humid summers as in some northern regions of the U.S. Field studies are essential to test the long-term hygrothermal performance of building envelopes. Although in-situ temperature, RH, and heat flux measurements are straightforward, moisture content measurements are cumbersome. Mainly, because of the heterogeneous nature of the wood materials, deviations and nonuniformities within the materials are unavoidable. Resistance measurements are one of the oldest methods used to measure the moisture content of wood and other building materials. In large-scale studies, it is commonly preferred to use multi-purpose data acquisition systems (DAQ) and custom-made or prefabricated moisture pins to measure the electrical resistance (and thus moisture content) of critical building materials. These multi-purpose DAQ systems generally provide lower costs and offer more flexibility. However, these systems require calibration and fine-tuning to achieve accurate moisture content measurements. A large-scale, two-year-long field study was conducted in northern Minnesota to monitor the hygrothermal performance of residential retrofit wall systems in cold climates. Two base case walls and sixteen different wall treatments were tested. Moisture contents were measured at various layers in each wall treatment using 85 sets of moisture pins. This paper focuses on the overall approach, fabrication, and calibration methodology for the combination of custom-made moisture pins and a multi-purpose DAQ. The aim is to directly use the low-excitation multi-purpose DAQ without any extra voltage regulator. A half-bridge circuit is used to measure wood resistance with 4V excitation voltage and 100 kΩ and 500 kΩ reference resistors. The system is calibrated for four different materials: Douglas fir, lodgepole pine, western red cedar, and oriented strand board (OSB). Calibration experiments were done under controlled conditions in 50% and 65% RH test chambers. Resistance-based moisture content calibration curves are obtained for each species. Results show that higher reference resistors provided better calibration curves for lower excitation voltages.

Desjarlais, Andre Omer↗

Attentional Ptycho-Tomography (APT) for three-dimensional nanoscale X-ray imaging with minimal data acquisition and computation time

Abstract Noninvasive X-ray imaging of nanoscale three-dimensional objects, such as integrated circuits (ICs), generally requires two types of scanning: ptychographic, which is translational and returns estimates of the complex electromagnetic field through the IC; combined with a tomographic scan, which collects these complex field projections from multiple angles. Here, we present Attentional Ptycho-Tomography (APT), an approach to drastically reduce the amount of angular scanning, and thus the total acquisition time. APT is machine learning-based, utilizing axial self-Attention for Ptycho-Tomographic reconstruction. APT is trained to obtain accurate reconstructions of the ICs, despite the incompleteness of the measurements. The training process includes regularizing priors in the form of typical patterns found in IC interiors, and the physics of X-ray propagation through the IC. We show that APT with ×12 reduced angles achieves fidelity comparable to the gold standard Simultaneous Algebraic Reconstruction Technique (SART) with the original set of angles. When using the same set of reduced angles, then APT also outperforms Filtered Back Projection (FBP), Simultaneous Iterative Reconstruction Technique (SIRT) and SART. The time needed to compute the reconstruction is also reduced, because the trained neural network is a forward operation, unlike the iterative nature of these alternatives. Our experiments show that, without loss in quality, for a 4.48 × 93.2 × 3.92 µm 3 IC (≃6 × 10 8 voxels), APT reduces the total data acquisition and computation time from 67.96 h to 38 min. We expect our physics-assisted and attention-utilizing machine learning framework to be applicable to other branches of nanoscale imaging, including materials science and biological imaging.

47 OTHER INSTRUMENTATION↗

Accelerating data acquisition with FPGA-based edge machine learning: a case study with LCLS-II

New scientific experiments and instruments generate vast amounts of data that need to be transferred for storage or further processing, often overwhelming traditional systems. Edge machine learning (EdgeML) addresses this challenge by integrating machine learning (ML) algorithms with edge computing, enabling real-time data processing directly at the point of data generation. EdgeML is particularly beneficial for environments where immediate decisions are required, or where bandwidth and storage are limited. In this paper, we demonstrate a high-speed configurable ML model in a fully customizable EdgeML system using a field programmable gate array (FPGA). Our demonstration focuses on an angular array of electron spectrometers, referred to as the ‘CookieBox,’ developed for the Linac Coherent Light Source II project. The EdgeML system captures 51.2 Gbps from a 6.4 GS s −1 analog to digital converter and is designed to integrate data pre-processing and ML inside an FPGA. Our implementation achieves an inference latency of 0.2 µs for the ML model, and a total latency of 0.4 µs for the complete EdgeML system, which includes pre-processing, data transmission, digitization, and ML inference. The modular design of the system allows it to be adapted for other instrumentation applications requiring low-latency data processing.

97 MATHEMATICS AND COMPUTING↗

Alternating conduction and convection drying of paper – an experimental analysis with a continuous data acquisition approach

In conventional multi-cylinder drying of paper and board, both conductive drying from steam-heated dryer cylinders and convective drying by flowing air over the paper surface in the pockets are used. Conductive drying from steam-heated drying cylinders is a critical component in providing the necessary thermal energy to paper and board as they dry. Steam temperature and internal and external resistances at the contacting surface are critical process parameters influencing the conductive drying process. An experimental setup was developed to study the alternating conductive and convective drying of paper and board. Paper sheet moisture, temperature, and temperature distribution within the heated platen and the instantaneous heat flux as the sheet was being dried were measured. The instantaneous heat flux, contact heat transfer coefficient, and drying rates were determined as drying proceeds. Experimental results, as well as comparisons to literature and commercial data, are presented. The conductive heat transfer coefficients determined were compared to traditional correlations normally used in the modeling of paper drying. Similarly, the convective heat and mass transfer coefficients are also determined and compared to literature data. In addition to the evaluation of alternating conductive and convective drying characteristics of paper and board, the potential inclusion of auxiliary energy components will also be included. Experimental results from the conduction and convection drying system are presented. Furthermore, this data will be useful in process development, intensification of manufacturing processes, and modeling and simulation of paper drying processes.

42 ENGINEERING↗