Upgrade of the Minos+ Experiment Data Acquisition for the High Energy NuMI Beam Run

The Minos+ experiment is an extension of the Minos experiment at a higher energy and more intense neutrino beam, with the data collection having begun in the fall of 2013. The neutrino beam is provided by the Neutrinos from the Main Injector (NuMI) beam-line at Fermi National Accelerator Laboratory (Fermilab). The detector apparatus consists of two main detectors, one underground at Fermilab and the other in Soudan, Minnesota with the purpose of studying neutrino oscillations at a base line of 735 km. The original data acquisition system has been running for several years collecting data from NuMI, but with the extended run from 2013, parts of the system needed to be replaced due to obsolescence, reliability problems, and data throughput limitations. Specifically, we have replaced the front-end readout controllers, event builder, and data acquisition computing and trigger processing farms with modern, modular and reliable devices with few single points of failure. The new system is based on gigabit Ethernet TCP/IP communication to implement the event building and concatenation of data from many front-end VME readout crates. The simplicity and partitionability of the new system greatly eases the debugging and diagnosing process. As a result, the new system improves throughput by about a factor of three compared to the old system, up to 800 megabits per second, and has proven robust and reliable in the current run.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Front-end electronic readout system for the Belle II imaging Time-Of-Propagation detector

The Time-Of-Propagation detector is a Cherenkov particle identification detector based on quartz radiator bars for the Belle II experiment at the SuperKEKB ee collider. The purpose of the detector is to identify the type of charged hadrons produced in ee collisions, and requires a single photon timing resolution below 100 picoseconds. A novel front-end electronic system was designed, built, and integrated to acquire data from the 8192 microchannel plate photomultiplier tube channels in the detector. Waveform sampling of these analog signals is done by switched-capacitor array application-specific integrated circuits. The processes of triggering, digitization of windows of interest, readout, and data transfer to the Belle II data acquisition system are managed by Xilinx Zynq-7000 programmable system on a chip devices.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Nanosecond Gated CMOS Camera (NSGCC) ICD (Rev. 2.1)

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time-gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and LLNL’s National Ignition Facility (NIF). Several cameras have been designed over the length of the program; one of the most recent is the Icarus, which is an improvement on past imagers (Furi and Hippogriff). A second sensor that can be connected is the Daedalus sensor. The Icarus is a 1024 × 512-pixel array with either 25 μm or 8 µm spatial resolution containing four frames of storage per pixel and has improved timing generation and distribution components while achieved 2 ns time gating. The Daedalus sensor is also a 1024 x 512-pixel array with 25 µm special resolution containing three frames of storage per pixel and has an increased set of features for a wider variety of applications from interlacing of rows in each frame to configurability of all shutters. See Section 14 for details regarding the Icarus implementation of the firmware and Section 15 for details regarding the Daedalus implementation. Due to the unique test environments UXI sensors are targeted for, full custom hardware was required to physically mount an Icarus or Daedalus sensor, manage its various functions, and read out pixel data for transfer to a host computer. Beyond experimental functionality, the hardware also needed to accommodate sensor characterization requirements. Lawrence Livermore National Laboratory’s ‘Version 4.0 Board’ was the result of these efforts. It mounts all the components required to fully utilize the Icarus and Daedalus sensors including analog to digital converters to convert pixel data and various system voltages to digital form for readout and analysis, DAC channels for remote configuration of critical bias voltages, static random-access memories to buffer pixel data, RS422 and Gigabit Ethernet communications for remote access, and an FPGA to tie these components together. This document describes the FPGA electrical interfaces in detail to allow the reader a greater understanding of the device, and to facilitate implementation of custom software to control and manage it. The Version 4.0 Board is a continuation of the Nano-second Gated CMOS hardware design that retains much of the functionality of the Version 1.0 Board while adding features including a DAC instead of digital potentiometers, as well as sensors for pressure and radiation. The Version 4.0 board is intended for applications requiring tight form-factor enclosures. It is composed of two stacking boards; one holds the FPGA and regulators to power the various components of the board while the other contains the mating connector to the sensor, image-readoff ADCs, the DAC, and other components.

42 ENGINEERING↗

The MicroBooNE continuous readout stream for detection of supernova neutrinos

Since the original detection of core-collapse supernova neutrinos in 1987, all large neutrino experiments seek to detect the neutrinos from the next nearby supernova. Among them, liquid argon time projection chambers (LArTPCs) offer a unique sensitivity to the electron neutrino flux of a supernova. However, the low energy of these events (scale of MeVs), and the fact that all large (multi-tonne) LArTPCs operating at the moment are located near the Earth's surface, and are therefore subject to an intense cosmic ray flux, makes triggering on the supernova neutrinos very challenging. Instead, MicroBooNE has pioneered a novel approach for detecting supernova neutrinos based on a continuous readout stream and a delayed trigger generated by other neutrino detectors (the Supernova Early Warning System, or SNEWS). MicroBooNE's data is stored temporarily for a few days, awaiting a SNEWS alert to prompt the permanent recording of the data. In order to cope with the large data rates produced by the continuous readout of the TPC and the PMT systems of MicroBooNE, FPGA-based zero-suppression algorithms have been developed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of the Stratospheric Aerosol and Gas Experiment II (SAGE II) instrument

Design and performance data are analyzed for the Stratospheric Aerosol and Gas Experiment II (SAGE II) instrument, which has been developed for the NASA Earth Radiation Budget Satellite (ERBS). SAGE II is designed to monitor globally, from 70 degrees S to 70 degrees N latitude, the vertical distribution of stratospheric aerosols, ozone, water vapor, and nitrogen dioxide by measuring the extinction of solar radiation through the earth's atmosphere during the ERBS observatory solar occultations. A flat scanning mirror reflects solar radiation into a Cassegrain type telescope, which forms a solar image on the entrance slit of a grating spectrometer. The instantaneous-field-of-view of the SAGE II is scanned along the vertical solar diameter by the elevation scan mirror. The optical system is contained within an azimuth gimbal which tracks the solar radiometric centroid during the data event, while the spectrometer isolates seven spectral wavelengths from 0.385-1.02 micrometers. The seven channels of the spectrometer use silicon photodiode dedectors operated in the photovoltaic mode. The detector outputs are multiplexed into a serial data stream for readout by the ERBS telemetry system, with each output being sampled 64 times per second and digitized to 12 bit resolution.

Zaun, N. H.↗

The NOvA Data Acquisition System

The NOvA experiment is a long baseline neutrino experiment designed to make key measures to determine the neutrino mass hierarchy, neutrino mixing and CP violation in the neutrino sector. In order to make these measurements the NOvA collaboration has designed a highly distributed, synchronized, continuous digitization and readout system that is able to acquire and correlate data from the Fermilab accelerator complex, the NOvA near detector at Fermilab and the NOvA far detector which is located 810 km away at Ash River, MN. This system has unique properties that let it fully exploit the physics capabilities of the NOvA detector. This paper discusses the design of the NOvA DAQ system and its capabilities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NO$\nu$A Far Detector Data Acquisition System

The NOνA experiment is a long-baseline neutrino experiment designed to make measurements to determine the neutrino mass hierarchy, neutrino mixing parameters and CP violation in the neutrino sector. In order to make these measurements the NOνA collaboration has designed a highly distributed, synchronized, continuous digitization and readout system that is able to acquire and correlate data from the Fermilab accelerator complex (NuMI), the NOνA near detector at the Fermilab site and the NOνA far detector which is located 810 km away at Ash River, MN. This system has unique properties that let it fully exploit the physics capabilities of the NOνA detector. The design of the NOνA DAQ system and its capabilities are discussed in this paper.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Telemetry of intracranial pressure

A completely implantable epidural pressure telemetry system designed for accurate measurement of intracranial pressure (ICP) is described. The implant device is batteryless, providing unlimited operating life. The described system uses a capacitive pressure transducer with excellent long-term stability. Once detected with the transducer and converted to a frequency with the oscillator electronics, the pressure signal is digitized. It is then telemetered without the possibility of further degradation. After detection with the small external module, the data can be retransmitted by a radio link for complete patient mobility or the energizer signal pickup module can be wired to a bedside readout unit. Continuous data are available from the system so that the dynamic ICP changes reflecting arterial blood pressure can be observed and used for diagnosis.

Fryer, T. B.↗

Network Time Synchronization of the Readout Electronics for a New Radioactive Gas Detection System

In systems with multiple radiation detectors, time synchronization of the data collected from different detectors is essential to reconstruct multi-detector events such as scattering and coincidences. In cases where the number of detectors exceeds the readout channels in a single data acquisition electronics module, multiple modules have to be synchronized, which is traditionally accomplished by distributing clocks and triggers via dedicated connections. To eliminate this added cabling complexity in the case of a new radioactive gas detection system prototype under development at the French Atomic Energy Commission, we implemented time synchronization between multiple XIA Pixie-Net detector readout modules through the existing Ethernet network, based on the IEEE 1588 precision time protocol. The detector system is dedicated to the measurement of radioactive gases at low activity and consists of eight large silicon pixels and two NaI(Tl) detectors, instrumented with a total of three 4-channel Pixie-Net modules. Detecting NaI(Tl)/silicon coincidences will make it possible to identify each radioisotope present in the sample. To allow these identifications at low activities, the Pixie-Net modules must be synchronized to a precision well below the targeted coincidence window of 500-1000 ns. Being equipped with an Ethernet PHY compatible with IEEE 1588 and synchronous Ethernet that outputs a locally generated but system-wide synchronized clock, the Pixie-Net can operate its analog to digital converters and digital processing circuitry with that clock and match time stamps for captured data across the three modules. Depending on the network configuration and synchronization method, the implementation is capable to achieve timing precisions between 300 ns and 200 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Streaming readout for next generation electron scattering experiments

Current and future experiments at the high-intensity frontier are expected to produce an enormous amount of data that needs to be collected and stored for offline analysis. Thanks to the continuous progress in computing and networking technology, it is now possible to replace the standard ‘triggered’ data acquisition systems with a new, simplified and outperforming scheme. ‘Streaming readout’ (SRO) DAQ aims to replace the hardware-based trigger with a much more powerful and flexible software-based one, that considers the whole detector information for efficient real-time data tagging and selection. Considering the crucial role of DAQ in an experiment, validation with on-field tests is required to demonstrate SRO performance. In this paper, we report results of the on-beam validation of the Jefferson Lab SRO framework. In this work, we exposed different detectors (PbWO-based electromagnetic calorimeters and a plastic scintillator hodoscope) to the Hall-D electron-positron secondary beam and to the Hall-B production electron beam, with increasingly complex experimental conditions. By comparing the data collected with the SRO system against the traditional DAQ, we demonstrate that the SRO performs as expected. Furthermore, we provide evidence of its superiority in implementing sophisticated AI-supported algorithms for real-time data analysis and reconstruction.

47 OTHER INSTRUMENTATION↗

Rate-capability of the VMM3a front-end in the RD51 Scalable Readout System

The VMM3a is an Application Specific Integrated Circuit (ASIC), specifically developed for the readout of gaseous detectors. Originally developed within the ATLAS New Small Wheel (NSW) upgrade, it has been successfully integrated into the Scalable Readout System (SRS) of the RD51 collaboration. This allows, to use the VMM3a also in small laboratory set-ups and mid-scale experiments, which make use of Micro-Pattern Gaseous Detectors (MPGDs). As part of the integration of the VMM3a into the SRS, the readout and data transfer scheme was optimised to reach a high rate-capability of the entire readout system and profit from the VMM3a's high single-channel rate-capability of 3.6Mhits/s. The optimisation focused mainly on the handling of the data output stream of the VMM3a, but also on the development of a trigger-logic between the front-end cards and the DAQ computer. In this article, two firmware implementations of the non-ATLAS continuous readout mode are presented, as well as the implementation of the trigger-logic. Afterwards, a short overview on X-ray imaging results is presented, to illustrate the high rate-capability from an application point-of-view.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Earth Observatory Satellite system definition study. Report 5: System design and specifications. Volume 7: Specification for EOS low cost readout station

The functional, performance, and design requirements for the Low Cost Readout Station (LCRS) which supports the Earth Observatory Satellite (EOS) data system are described. The basic LCRS consists of all hardware and software needed to acquire and track the EOS-A or EOS-B satellite and receive, record, process, and annotate the instrument data from the satellites. The LCRS also provides appropriate interfaces with the unique local user provided display and extractive processing equipment. The LCRS has the capability of acquiring image data from the EOS-A and the EOS-B satellites over a ground area defines by a 500 kilometer radius from the coordinates of the station. The LCRS is also capable of receiving and processing both, but not simultaneously, full five band Multispectral Scanner (MSS) image data and various modes of the Compacted Thematic (CTM) data.

Source record↗

Simulation of the Charge Measurements for the SuperCDMS Soudan Experiment

Astronomical observations lead us to believe that dark matter constitutes the majority of the mass of the Universe, yet it has never been directly observed experimentally. The Super Cryogenic Dark Matter Search Experiment (SuperCDMS) aims to discover the particle nature of dark matter, by developing and using some of the most sensitive detectors ever built. The SuperCDMS detectors are capable of rejecting known particles to search for dark matter interactions, but the discrimination is a complicated analysis task. Previous analyses with SuperCDMS set world leading sensitivity limits to dark matter interactions, but the analysis techniques have not been based on simulations. Now we have developed an efficient simulations infrastructure that will help better understand the detectors, develop a better background model, and optimize the next generation dark matter searches. In this thesis we present the fully-functional simulations infrastructure to produce high quality samples a s well as results for the charge system readout simulations, and comparisons to expectations from data. We show that our simulations well-reproduce dominant features of data, bringing SuperCDMS closer to a robust simulation-based analysis method, much needed for the upcoming SuperCDMS dark matter searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

TDRSS/user satellite timing study

A timing analysis for data readout through the Tracking and Data Relay Satellite System (TDRSS) was presented. Various time tagging approaches were considered and the resulting accuracies delineated. The TDRSS was also defined and described in detail.

Mcgregor, D.↗

Multiplexed Holographic Data Storage in Bacteriorhodopsin

High density optical data storage, driven by the information revolution, remains at the forefront of current research areas. Much of the current research has focused on photorefractive materials (SBN and LiNbO3) and polymers, despite various problems with expense, durability, response time and retention periods. Photon echo techniques, though promising, are questionable due to the need for cryogenic conditions. Bacteriorhodopsin (BR) films are an attractive alternative recording medium. Great strides have been made in refining BR, and materials with storage lifetimes as long as 100 days have recently become available. The ability to deposit this robust polycrystalline material as high quality optical films suggests the use of BR as a recording medium for commercial optical disks. Our own recent research has demonstrated the suitability of BR films for real time spatial filtering and holography. We propose to fully investigate the feasibility of performing holographic mass data storage in BR. Important aspects of the problem to be investigated include various data multiplexing techniques (e.g. angle- amplitude- and phase-encoded multiplexing, and in particular shift-multiplexing), multilayer recording techniques, SLM selection and data readout using crossed polarizers for noise rejection. Systems evaluations of storage parameters, including access times, memory refresh constraints, erasure, signal-to-noise ratios and bit error rates, will be included in our investigations.

Mehrl, David J.↗

A Temperature Sensor using a Silicon-on-Insulator (SOI) Timer for Very Wide Temperature Measurement

A temperature sensor based on a commercial-off-the-shelf (COTS) Silicon-on-Insulator (SOI) Timer was designed for extreme temperature applications. The sensor can operate under a wide temperature range from hot jet engine compartments to cryogenic space exploration missions. For example, in Jet Engine Distributed Control Architecture, the sensor must be able to operate at temperatures exceeding 150 C. For space missions, extremely low cryogenic temperatures need to be measured. The output of the sensor, which consisted of a stream of digitized pulses whose period was proportional to the sensed temperature, can be interfaced with a controller or a computer. The data acquisition system would then give a direct readout of the temperature through the use of a look-up table, a built-in algorithm, or a mathematical model. Because of the wide range of temperature measurement and because the sensor is made of carefully selected COTS parts, this work is directly applicable to the NASA Fundamental Aeronautics/Subsonic Fixed Wing Program--Jet Engine Distributed Engine Control Task and to the NASA Electronic Parts and Packaging (NEPP) Program. In the past, a temperature sensor was designed and built using an SOI operational amplifier, and a report was issued. This work used an SOI 555 timer as its core and is completely new work.

Patterson, Richard L.↗

A blessing in disguise : Characterisations of ProtoDUNE photon showers for neutrino measurements in DUNE

There are few areas of particle physics as open to new discoveries as the neutrino sector. Although these particles are among the most abundant in the universe, their weak coupling to ordinary matter makes them a challenge to study. The Deep Underground Neutrino Experiment (DUNE) is an upcoming precision experiment in neutrino physics planned to be built between Illinois and South Dakota in the US. The most powerful neutrino beam in the world will be aimed at the largest liquid argon time projection chamber in the world through 1300 km of solid rock. In order to prototype this detector, a scale model was constructed and operated at CERN in 2018 called ProtoDUNE. This thesis presents three studies performed on this detector. The first concerns the readout of detector data by the FELIX data acquisition system, as well as compression studies performed on the same data. The second study concerns the identification of photons created in neutral pion decay, which form a major background to neutrino-produced electrons. The distinction between electrons and photons is based on the differing energy deposition in the initial part of the particle showers they produce. The third study concerns the energy reconstruction of particle showers in the detector. Although photon showers created from neutral pion decay are a major background to the eventual neutrino signal, they have a known energy profile and can thus be used to calibrate the energy reconstruction of particle showers in general, a vital requirement for DUNE’s physics goals.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Blessing in Disguise -- Characterisations of ProtoDUNE photon showers for neutrino measurements in DUNE

This thesis presents three studies performed on ProtoDUNE, a prototype liquid argon time projection chamber for the Deep Underground Neutrino Experiment (DUNE). The first study concerns the readout of detector data by the FELIX data acquisition system, as well as compression studies performed on the same data. The second study concerns the identification of photons created in neutral pion decay, which form a major background to neutrino-produced electrons. The distinction between electrons and photons is based on the differing energy deposition in the initial part of the particle showers they produce. The third study concerns the energy reconstruction of these particle showers in the detector. They have a known energy profile and can thus be used to calibrate the energy reconstruction of particle showers in general, a vital requirement for DUNE’s physics goals.