The development, testing and characterisation of a straw tracking detector and readout system for the Fermilab muon g-2 experiment

The anomalous magnetic moments of leptons can be both measured and theoretically predicted with high precision, and as such provide stringent tests of the Standard Model (SM) of particle physics. The anomalous magnetic moment of the muon, $a_\mu$, in particular offers sensitivity to new physics within the reach of current experiments. The current world’s best measurement of aμ made at the Brookhaven National Laboratory (BNL) deviates from the SM prediction by over 3σ, providing a tantalising but inconclusive hint that contributions from new physics may be present. A new $a_\mu$ experiment is currently under construction at the Fermi National Accelerator Laboratory (Fermilab), known as the Fermilab muon g-2 experiment. Due to commence in 2017, this new experiment is expected to improve the experimental measurement precision of $a_\mu$ by a factor of 4, and is seeking to confirm or reject the current discrepancy. The experiment, like its BNL predecessor, will measure the precession of the $\mu^{+}$ spin in a magnetic storage-ring. This new experiment has three straw tracking detectors used to measure the beam profile of the stored $\mu^{+}$, as well as other dynamic properties of the beam. This thesis describes the design of these detectors, and the data acquisition system and subsequent data processing systems that have been developed to read them out and make their data available for physics analysis. The performance of the straw trackers and the readout systems at a number of beam tests and test stands is presented, in addition to Monte-Carlo simulations of the trackers in the final experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Commissioning of the Mu2e tracker DAQ, planning for the Vertical Slice Test and pre-pattern recognition studies

The primary objective of the Mu2e experiment at Fermilab is to search for the neutrino-less coherent $\mu \rightarrow e$ conversion in the field of an aluminum nucleus ($\mu^- \text{Al} \rightarrow e^- \text{Al}$). The signature of this process is a monochromatic Conversion Electron (CE) with an energy of approximately 104.97 MeV \cite{bartoszek2015mu2e}. Within the Standard Model (SM), the branching ratio for this process, including neutrino masses and oscillation, is expected to be less than $\mathcal{O}(10^{-50})$. This value is far beyond current experimental capabilities. However, models of physics beyond the SM predict much higher relative rates, approaching an observable level. The SINDRUM II experiment set an upper limit on muon conversion at $7 \times 10^{-13}$ (90\% CL) on Au target \cite{SINDRUMII:2006dvw}, and the Mu2e collaboration aims to improve this limit by four orders of magnitude. Observing this process would provide a clear evidence of physics beyond the Standard Model. A brief discussion of the theoretical and experimental aspects is provided in Chapter \ref{intr}. Mu2e adopts a sophisticated experimental setup to achieve its goals, further described in Chapter \ref{mu2echapter}. The central part of the Mu2e detector is the tracker, that consists of 18 tracking stations. The tracker must provide excellent momentum resolution, approximately 1 MeV/c, to distinguish the monochromatic CE signal from the background. To minimize the energy losses, a straw tube tracker will be used \cite{bobbb}. Chapter \ref{chaptertrk} provides an overview of the straw tracker design and its working principles. This Thesis presents a comprehensive study of the Mu2e tracker, covering complementary aspects from initial commissioning to optimization and first steps of the calibration processes. My work at Fermilab has been focused on the complete Data Acquisition (DAQ) testing from both hardware and software perspectives. I was involved in the commissioning of the Mu2e DAQ system and the Vertical Slice Test (VST) of the tracker. The VST encompasses the entire testing chain, from the straws to the readout, and to processed data on disk. I was also focused on the offline analysis, especially on pre-pattern recognition studies, to explore the best methods for identifying $\delta$-electrons during the data taking. Chapter \ref{commissioning} details the commissioning of the tracker DAQ system, emphasizing the importance of understanding of the readout process before the data acquisition. This includes validating the readout logic and firmware through Monte Carlo simulations to confirm functionality and buffering, monitoring the quality of the data from the tracker preamplifiers and front-end electronics, and assessing overall DAQ performance to ensure reliability during future calibration and data-taking. Chapter \ref{planning} discusses the initial steps towards the tracker calibration. The ultimate goal is to perform a time calibration of the first assembled station of the tracker using cosmic muons, aiming for a longitudinal hit position resolution better than 4 cm. This involves determining the signal propagation times and channel-to-channel delays. I performed a Monte Carlo study to determine the impact of the station orientation on the quality of the calibration, in particular on the cosmic track reconstruction, focusing on potential biases that could arise. These studies provide essential insights into the operation, optimization, and calibration of the Mu2e tracker system. Given the high data volume expected during Mu2e operations, estimated at approximately 7 PBytes per year, optimizing memory usage and minimizing CPU consumption are critical. A significant challenge lies in effectively flagging $\delta$-electron hits, which are the primary source of hits in the tracker, without compromising the efficiency of CE hit detection and track reconstruction. A detailed study of pre-pattern recognition and a thorough comparison of two $\delta$-electron flagging algorithms is provided in Chapter \ref{delta}. In Chapter \ref{conclusions}, the findings are concisely summarized, offering a comprehensive synthesis of the research and emphasizing the key insights derived from this study.

43 PARTICLE ACCELERATORS↗

THE ARCONS PIPELINE: DATA REDUCTION FOR MKID ARRAYS

The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. Here we outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

OVERVIEW OF THE KEPLER SCIENCE PROCESSING PIPELINE

The Kepler Mission Science Operations Center (SOC) performs several critical functions including managing the {approx}156,000 target stars, associated target tables, science data compression tables and parameters, as well as processing the raw photometric data downlinked from the spacecraft each month. The raw data are first calibrated at the pixel level to correct for bias, smear induced by a shutterless readout, and other detector and electronic effects. A background sky flux is estimated from {approx}4500 pixels on each of the 84 CCD readout channels, and simple aperture photometry is performed on an optimal aperture for each star. Ancillary engineering data and diagnostic information extracted from the science data are used to remove systematic errors in the flux time series that are correlated with these data prior to searching for signatures of transiting planets with a wavelet-based, adaptive matched filter. Stars with signatures exceeding 7.1{sigma} are subjected to a suite of statistical tests including an examination of each star's centroid motion to reject false positives caused by background eclipsing binaries. Physical parameters for each planetary candidate are fitted to the transit signature, and signatures of additional transiting planets are sought in the residual light curve. The pipeline is operational, finding planetary signatures and providing robust eliminations of false positives.

79 ASTRONOMY AND ASTROPHYSICS↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Magnetic Microcalorimeter (MMC) Gamma-Ray Detectors with Ultra-High Energy Resolution. Comprehensive Technology Readiness Assessment

Magnetic Microcalorimeter (MMC) gamma ray detectors have demonstrated very high energy resolution of 38 eV FWHM for gamma ray energies below 100 keV. This is an order or magnitude better than conventional HPGe detector and can remove most line-overlap problems in NDA by gamma spectroscopy below ~130 keV. Unlike superconducting transition edge sensors (TESs), MMCs have a reproducible and almost perfectly linear response, which greatly simplifies adding spectra from different detector pixels and reduces systematic errors in quantitative assays. The instrument is currently at TRL-5 but could advance to TRL-6 by improving the signal processing software and using the system for the quantitative analysis of a safeguards sample provided by e.g. the IAEA. Making MMC detectors commercially viable and used more widely then depends on making the technology more reliable, specifically by increasing the device uniformity and yield, and by developing commercial software. This situation is often only half-jokingly referred to as the “valley of death” and could be addressed though the SBIR program. Our collaborators at STAR Cryoelectronics LLC are well qualified to further advance MMC development, and XIA LLC is well-positioned to develop the data acquisition system and write the software for MMC readout. In addition, the advance to TRL-6 would be desirable to increase the visibility and showcase the value of MMC spectrometers, e.g. by placing one of them into the Safeguards Analytical Laboratory (SAL) at the IAEA, whose NDA experts have recently started to show interest in cryogenic detector technology. As a result of this LCP, we also now have an instrument at LLNL that we will use for various applications of MMCs in nuclear safeguards and science. We are confident that as the number of high-profile results increases, so will the interest in and commercial viability of this technology.

42 ENGINEERING↗

Design and Construction of Detector and Data Acquisition Elements for Proton Computed Tomography

Proton computed tomography (pCT) offers an alternative to x-ray imaging with potential for three-dimensional imaging, reduced radiation exposure, and in-situ imaging. Northern Illinois University (NIU) is developing a second-generation proton computed tomography system with a goal of demonstrating the feasibility of three-dimensional imaging within clinically realistic imaging times. The second-generation pCT system is comprised of a tracking system, a calorimeter, data acquisition, a computing farm, and software algorithms. The proton beam encounters the upstream tracking detectors, the patient or phantom, the downstream tracking detectors, and a calorimeter. The schematic layout of the PCT system is shown. The data acquisition sends the proton scattering information to an offline computing farm. Major innovations of the second generation pCT project involve an increased data acquisition rate ( MHz range) and development of three-dimensional imaging algorithms. The Fermilab Particle Physics Division and Northern Illinois Center for Accelerator and Detector Development at Northern Illinois University worked together to design and construct the tracking detectors, calorimeter, readout electronics and detector mounting system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

STAR Vertex Detector Upgrade Development

We report on the development and prototyping efforts undertaken with the goal of producing a micro-vertex detector for the STAR experiment at the RHIC accelerator at BNL. We present the basic detector requirements and show a sensor development path, conceptual mechanical design candidates and readout architecture. Prototyping and beam test results with current generation MimoSTAR-2 sensors and a readout system featuring FPGA based on-the-fly hit finding and data sparsification are also presented.

43 PARTICLE ACCELERATORS↗

Data Acquisition System of Nobeyama MKID Camera

We are developing a superconducting camera based on microwave kinetic inductance detectors (MKIDs) to observe 100-GHz continuum with the Nobeyama 45-m telescope. A data acquisition (DAQ) system for the camera has been designed to operate the MKIDs with the telescope. This system is required to connect the telescope control system (COSMOS) to the readout system of the MKIDs (MKID DAQ) which employs the frequency-sweeping probe scheme. The DAQ system is also required to record the reference signal of the beam switching for the demodulation by the analysis pipeline in order to suppress the sky fluctuation. The system has to be able to merge and save all data acquired both by the camera and by the telescope, including the cryostat temperature and pressure and the telescope pointing. A collection of software which implements these functions and works as a TCP/IP server on a workstation was developed. The server accepts commands and observation scripts from COSMOS and then issues commands to MKID DAQ to configure and start data acquisition. We made a commissioning of the MKID camera on the Nobeyama 45-m telescope and obtained successful scan signals of the atmosphere and of the Moon.

42 ENGINEERING↗

Real-time performance of commercial Intel-based VME Controllers for the CODA data acquisition system

We have evaluated the performance of several Intel-based VME Controllers for the use in the data acquisition systems (DAQs) at Jefferson Lab. For the 12 GeV upgrade, PPC-based VME controllers running vxWorks will be replaced with those that are Intel-based running Linux. Their task will be facilitated by the use of FPGAs on the VME modules to perform trigger logic and communicating trigger information over serial and fiber connections through the DAQ. The need for a hard realtime operating system on the VME controller is removed from the equation as the readout of the digitized data from the VME modules (using VME-2eSST) is done in a threaded environment with multiple CPU cores while digitization takes place in the buffered, pipelined system. In this paper we brief discuss the 12 GeV Hall D DAQ and the requirements of the VME Controller. We present results from baseline testing of various models from different vendors using different Linux kernels, including results from a kernel compiled with the CONFIG_PREEMPT_RT patch.

Moffit, Bryan↗

Conceptual design of the modular detector and readout system for the CMB-S4 survey experiment

We present the conceptual design of the modular detector and readout system for the Cosmic Microwave Background – Stage four (CMB-S4) ground-based survey experiment. CMB-S4 will map the cosmic microwave background (CMB) and the millimeter-wave sky to unprecedented sensitivity, using 500,000 superconducting detectors observing from Chile and Antarctica to map over 60% of the sky. The fundamental building block of the detector and readout system is a detector module package operated at 100 mK, which is connected to a readout and amplification chain that carries signals out to room temperature. It uses arrays of feedhorn-coupled orthomode transducers (OMT) that collect optical power from the sky onto dc-voltage-biased transition-edge sensor (TES) bolometers. The resulting current signal in the TESs is then amplified by a two-stage cryogenic Superconducting Quantum Interference Device (SQUID) system with a time-division multiplexer to reduce wire count, and matching room-temperature electronics to condition and transmit signals to the data acquisition system. Sensitivity and systematics requirements are being developed for the detector and readout system over wide range of observing bands (20 to 300 GHz) and optical powers to accomplish CMB-S4’s science goals. While the design incorporates the successes of previous generations of CMB instruments, CMB-S4 requires an order of magnitude more detectors than any prior experiment. This requires fabrication of complex superconducting circuits on over 10 m2 of silicon, as well as significant amounts of precision wiring, assembly and cryogenic testing

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-I-88: The Effect of System Dead Time On Real-Time Plastic and GOS Based Fiber-Optic Dosimetry Systems

Purpose: A methodology is presented to correct for measurement inaccuracies at high detector count rates using a plastic and GOS scintillation fibers coupled to a photomultiplier tube with digital readout. This system allows temporal acquisition and manipulation of measured data. Methods: The detection system used was a plastic scintillator and a separate gadolinium scintillator, both (0.5 diameter) coupled to an optical fiber with a Hamamatsu photon counter with a built-in microcontroller and digital interface. Count rate performance of the system was evaluated using the nonparalzable detector model. Detector response was investigated across multiple radiation sources including: orthovoltage x-ray system, colbat-60 gamma rays, proton therapy beam, and a diagnostic radiography x-ray tube. The dead time parameter was calculated by measuring the count rate of the system at different exposure rates using a reference detector. Results: The system dead time was evaluated for the following sources of radiation used clinically: diagnostic energy x-rays, cobalt-60 gamma rays, orthovoltage xrays, particle proton accelerator, and megavoltage x-rays. It was found that dead time increased significantly when exposing the detector to sources capable of generating Cerenkov radiation, all of the sources sans the diagnostic x-rays, with increasing prominence at higher photon energies. Percent depth dose curves generated by a dedicated ionization chamber and compared to the detection system demonstrated that correcting for dead time improves accuracy. On most sources, nonparalzable model fit provided an improved system response. Conclusion: Overall, the system dead time was variable across the investigated radiation particles and energies. It was demonstrated that the system response accuracy was greatly improved by correcting for dead time effects. Cerenkov radiation plays a significant role in the increase in the system dead time through transient absorption effects attributed to electron hole-pair creations within the optical waveguide.

07 ISOTOPE AND RADIATION SOURCES↗

Reconstruction of the BNB and NuMI Neutrino Bunch Structure with ICARUS

ICARUS serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab, sitting on-axis on the Booster Neutrino Beam (BNB) and 6$^\circ$ off-axis from the Neutrinos at the Main Injector (NuMI) beam. Neutrinos from both beams inherit the timing sub-structure of their parent proton spills, which is in turn derived from either the Booster's or the Main Injector's synchrotron acceleration. Since neutrino propagation introduces only a constant offset, their timing structure is preserved as they travel. Identifying this structure in data represents a powerful tool for selecting neutrino events and searching for physics beyond the Standard Model (BSM). This poster presents the preliminary reconstruction of the BNB and NuMI neutrino bunch structure with ICARUS data, exploiting only the precise timing of ICARUS optical readout system to both locate and assign a time to each interaction.

43 PARTICLE ACCELERATORS↗

Reconstruction of the BNB and NuMI Neutrino Bunch Structure with ICARUS

ICARUS serves as the Far Detector of the Short Baseline Neutrino (SBN) program at Fermilab, sitting on-axis on the Booster Neutrino Beam (BNB) and 6$^\circ$ off-axis from the Neutrinos at the Main Injector (NuMI) beam. Neutrinos from both beams inherit the timing sub-structure of their parent proton spills, which is in turn derived from either the Booster's or the Main Injector's synchrotron acceleration. Since neutrino propagation introduces only a constant offset, their timing structure is preserved as they travel. Identifying this structure in data represents a powerful tool for selecting neutrino events and searching for physics beyond the Standard Model (BSM). This poster presents the preliminary reconstruction of the BNB and NuMI neutrino bunch structure with ICARUS data, exploiting only the precise timing of ICARUS optical readout system to both locate and assign a time to each interaction.

43 PARTICLE ACCELERATORS↗

Performance of a Modular Ton-Scale Pixel-Readout Liquid Argon Time Projection Chamber

The Module-0 Demonstrator is a single-phase 600 kg liquid argon time projection chamber operated as a prototype for the DUNE liquid argon near detector. Based on the ArgonCube design concept, Module-0 features a novel 80k-channel pixelated charge readout and advanced high-coverage photon detection system. In this paper, we present an analysis of an eight-day data set consisting of 25 million cosmic ray events collected in the spring of 2021. We use this sample to demonstrate the imaging performance of the charge and light readout systems as well as the signal correlations between the two. We also report argon purity and detector uniformity measurements and provide comparisons to detector simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A new FPGA-based trigger/DAQ system for the MTV experiment at TRIUMF

A new FPGA based data acquisition (DAQ) and trigger combined system is developed for the MTV experiment (Mott Polarimetry for T-Violation Experiment). The MTV experiment measures backward Mott scattering events by detecting the incident and scattered tracks using a drift chamber. For the backward scattering probability is as small as less than 0.1%, efficient triggering system is required to select the desired events. An intelligent Level-2 trigger system reading hitting pattern together with its digital readout system are built in a custom FPGA system. In this paper, design overview and results from performance tests are described.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

DUNE DAQ R&D integration in ProtoDUNE Single-Phase at CERN

The DAQ system of ProtoDUNE-SP successfully proved its design principles and met the requirements of the beam run of 2018. The technical design of the DAQ system for the DUNE experiment has major differences compared to the prototype due to different requirements placed on the detector, as well as a radically different location of operation. The single-phase prototype at CERN is a major integration facility for R&D aspects of the DUNE DAQ system. The facility allows for the exploration of additional data processing capabilities and optimization of the FELIX system, which is the chosen TPC readout solution for the DUNE single-phase detectors. One of the fundamental differences from the prototype is that the DUNE DAQ relies on self-triggering. Therefore, real-time processing of the data stream for hit and trigger primitive finding is essential for the requirement of continuous readout. The supernova burst trigger requires a large and fast buffering technique, where 3D XPoint persistent memory solutions are evaluated and integrated. In order to maximize resource utilization of the FELIX hosting servers, the elimination of the 100 Gb network communication stack is desired. This implies the design and development of a single-host application layer, which is a fundamental element of the self-triggering chain. This paper discusses the evaluation and integration of these developments for the DUNE DAQ, in the ProtoDUNE environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of a streaming readout solution for Jefferson Lab experiments

Jefferson Lab (JLab) operates the CEBAF accelerator that provides a high energy (up to 12 GeV) and high current (up to 150 µA) polarized electron beam for fixed target experiments. JLab's mission is to provide substantial progress in understanding the Quantum Chromo Dynamics (QCD), the current theory of the spectrum and the dynamics of hadronic matter. Given the broad scientific program a general-purpose detector, CLAS12, has been designed and constructed. Such a detector requires a sophisticated trigger and current experiments use an on-line FPGA-based system that relies upon custom firmware and electronics both of which are difficult reconfigure from one experiment to the next. To overcome these challenges transitioning to a streaming readout has been proposed since it would allow a more flexible, easier to debug, software trigger to be developed. To facilitate this JLab is gaining experience with streaming readout systems and is actively working to design and test a streaming data acquisition architecture. Significant work has already been done to make existing front-end electronics compatible with operation in streaming mode. Software-wise, much work remains to be done but an existing framework, TriDAS, which was developed for underwater neutrino telescopes can, in principle, be used with the existing JLab hardware. A test stand is already in place in the INDRA DAQ development lab at JLab. This paper will present the development of this TriDAS based test system and it?s operation in-beam using parts of the CLAS12 detector to evaluate streaming readout for a large general purpose detector.

Battaglieri, Marco↗