Search NASA⌕ Search

SEARCH · Search NASA

Results for “DETERMINANT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Rapid and efficient ambient temperature X-ray crystal structure determination at Turkish Light Source

High-resolution biomacromolecular structure determination is essential to better understand protein function and dynamics. Serial crystallography is an emerging structural biology technique which has fundamental limitations due to either sample volume requirements or immediate access to the competitive X-ray beamtime. Obtaining a high volume of well-diffracting, sufficient-size crystals while mitigating radiation damage remains a critical bottleneck of serial crystallography. As an alternative, we introduce the plate-reader module adapted for using a 72-well Terasaki plate for biomacromolecule structure determination at a convenience of a home X-ray source. We also present the first ambient temperature lysozyme structure determined at the Turkish light source (Turkish DeLight). The complete dataset was collected in 18.5 min with resolution extending to 2.39 Å and 100% completeness. Combined with our previous cryogenic structure (PDB ID: 7Y6A), the ambient temperature structure provides invaluable information about the structural dynamics of the lysozyme. Turkish DeLight provides robust and rapid ambient temperature biomacromolecular structure determination with limited radiation damage.

59 BASIC BIOLOGICAL SCIENCES↗

Spectroelectrochemical determination of thiolate self-assembled monolayer adsorptive stability in aqueous and non-aqueous electrolytes

Self-assembled monolayers (SAM) are ubiquitous in studies of modified electrodes for sensing, electrocatalysis, and environmental and energy applications. However, determining their adsorptive stability is crucial to ensure robust experiments. Here, in this work, the stable potential window (SPW) in which a SAM-covered electrode can function without inducing SAM desorption was determined for aromatic SAMs on gold electrodes in aqueous and non-aqueous solvents. The SPWs were determined by employing cyclic voltammetry, attenuated total reflectance surface-enhanced infrared absorption spectroscopy (ATR-SEIRAS), and surface plasmon resonance (SPR). The electrochemical and spectroscopic findings concluded that all the aromatic SAMs used displayed similar trends and SPWs. In aqueous systems, the SPW lies between the reductive desorption and oxidative desorption, with pH being the decisive factor affecting the range of the SPW, with the widest SPW observed at pH 1. In the non-aqueous electrolytes, the desorption of SAMs was observed to be slow and progressive. The polarity of the solvent was the main factor in determining the SPW. The lower the polarity of the solvent, the larger the SPW, with 1-butanol displaying the widest SPW. This work showcases the power of spectroelectrochemical analysis and provides ample future directions for the use of non-polar solvents to increase SAM stability in electrochemical applications.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

The cosine-sine decomposition with different-orbitals-for-different-spins determinants

We report the spin decomposition of a spin-contaminated different-orbitals-for-different-spins (DODS) wave function is formulated in terms of the Krylov space of the $\hat{S}^2$ ||operator. The number of determinants that contribute to the various projected spin eigenfunctions vertical | $\psi ; S, M \rangle$ depends on the sparsity of the orbital overlap matrix X between the α and β spatial orbitals. The cosine-sine decomposition (CSD) procedure may be applied to this overlap matrix, and the resulting redundant orbital transformations may be applied to the α and β spatial orbitals. This produces a sparse X' matrix in the transformed basis in which each row or column has either one or two nonzero elements. This sparse X' matrix simplifies the spin-decomposition procedure in three ways:1) it reduces the number of contributing determinants within the Krylov basis functions and within the projected spin functions, 2) it reduces the effective orbital dimension through elimination of the frozen core and frozen virtual orbitals, and 3) it simplifies the spin-decomposition procedure in both the original and transformed bases by limiting the Krylov space dimension. These simplifications all reduce the computational effort for the spin-decomposition process. This procedure is implemented within a string-based DODS determinant formulation and applied to spin projection of unrestricted Hartree-Fock determinants.

unrestricted Hartree-Fock↗

Introductory guide to backgrounds in XPS spectra and their impact on determining peak intensities

Photoelectron and Auger peaks are central to most of the important uses of x-ray photoelectron spectroscopy (XPS), and thus, they receive the most attention in many types of analysis. Quantitative chemical analysis using XPS requires the assessment of the intensities of the photoemission peaks of the elements detected. Determination of peak intensities requires separation of the photoelectron peak signals from the background on which the peaks rest. For the determination of peak area intensities, the background is subtracted from overall signal intensity. The spectral background is also critical when peak fitting is used to determine intensities of overlapping peaks, and the model of background used in this process can impact the results. In addition to the impact on quantitative analysis, information about the depth distribution of elements in the near surface region can often be obtained by visual inspection of the background and quantified using appropriate modeling. Here, this introductory guide provides some basic information about backgrounds in the XPS analysis, describes the types of background models that are commonly used, suggests some of their strengths and weaknesses, and provides examples of their use and misuse. Although the fundamental nature of some components of the background signals in XPS is not understood, indicating that none of the models in use are fully correct and the area is subject to active research, appropriate good practices have been established for most routine analysis. The guide describes good practices, identifies errors that frequently appear in the literature, and uses examples to demonstrate the impacts of background selections on determinations of peak intensities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Spectroscopic Techniques for Determining the Peroxide Value of 19 Classes of Naturally Aged, Plant-Based Edible Oils

The peroxide value of edible oils is a measure of the degree of oxidation, which directly relates to the freshness of the oil sample. Several studies previously reported in the literature have paired various spectroscopic techniques with multivariate analyses to rapidly determine peroxide values using field portable and process instrumentation; those efforts presented “best-case scenarios” with oils from narrowly defined training and test sets. The purpose of this paper is to evaluate the use of near- and mid-infrared absorption and Raman scattering spectroscopies on oil samples from different oil classes, including seasonal and vendor variations, to determine which measurement technique or combination thereof is best for predicting peroxide values. Following peroxide value assays of each oil class using an established titration-based method, global and global-subset calibration models were constructed from spectroscopic data collected on the 19 oil classes used in this study. Spectra from each optical technique were used to create partial least squares regression calibration models to predict the peroxide value of unknown oil samples. A global peroxide value model based on near-infrared (8 mm optical path length) oil measurements produced the lowest RMSEP (4.9), followed by 24 mm optical path length near infrared (5.1), Raman (6.9) and 50 µm optical path length mid-infrared (7.3). However, it was determined that the Raman RMSEP resulted from chance correlations. Global peroxide value models based on low-level fusion of the NIR (8 and 24 mm optical path length) data and all infrared data produced the same RMSEP of 5.1. Global subset models, based on any of the spectroscopies and olive oil training sets from any class (pure, extra light, extra virgin), all failed to extrapolate to the non-olive oils. However, the near-infrared global subset model built on extra virgin olive oil could extrapolate to test samples from other olive oil classes. This work demonstrates the difficulty of developing a truly global method for determining peroxide value of oils.

36 MATERIALS SCIENCE↗

Comparison of methodologies used to determine aromatic lignin unit ratios in lignocellulosic biomass

Abstract Background Multiple analytical methods have been developed to determine the ratios of aromatic lignin units, particularly the syringyl/guaiacyl (S/G) ratio, of lignin biopolymers in plant cell walls. Chemical degradation methods such as thioacidolysis produce aromatic lignin units that are released from certain linkages and may induce chemical changes rendering it difficult to distinguish and determine the source of specific aromatic lignin units released, as is the case with nitrobenzene oxidation methodology. NMR methods provide powerful tools used to analyze cell walls for lignin composition and linkage information. Pyrolysis-mass spectrometry methods are also widely used, particularly as high-throughput methodologies. However, the different techniques used to analyze aromatic lignin unit ratios frequently yield different results within and across particular studies, making it difficult to interpret and compare results. This also makes it difficult to obtain meaningful insights relating these measurements to other characteristics of plant cell walls that may impact biomass sustainability and conversion metrics for the production of bio-derived fuels and chemicals. Results The authors compared the S/G lignin unit ratios obtained from thioacidolysis, pyrolysis-molecular beam mass spectrometry (py-MBMS), HSQC liquid-state NMR and solid-state (ss) NMR methodologies of pine, several genotypes of poplar, and corn stover biomass. An underutilized approach to deconvolute ssNMR spectra was implemented to derive S/G ratios. The S/G ratios obtained for the samples did not agree across the different methods, but trends were similar with the most agreement among the py-MBMS, HSQC NMR and deconvoluted ssNMR methods. The relationship between S/G, thioacidolysis yields, and linkage analysis determined by HSQC is also addressed. Conclusions This work demonstrates that different methods using chemical, thermal, and non-destructive NMR techniques to determine native lignin S/G ratios in plant cell walls may yield different results depending on species and linkage abundances. Spectral deconvolution can be applied to many hardwoods with lignin dominated by S and G units, but the results may not be reliable for some woody and grassy species of more diverse lignin composition. HSQC may be a better method for analyzing lignin in those species given the wealth of information provided on additional aromatic moieties and bond linkages. Additionally, trends or correlations in lignin characteristics such as S/G ratios and lignin linkages within the same species such as poplar may not necessarily exhibit the same trends or correlations made across different biomass types. Careful consideration is required when choosing a method to measure S/G ratios and the benefits and shortcomings of each method discussed here are summarized.

09 BIOMASS FUELS↗

Determination of Stress-Free Lattice Spacing (D₀) for Residual Stress Relaxation Measurement in Ni-based Superalloys by Neutron Diffraction

The residual stress and its relaxation in critical engineering components are key to structural materials reliability. The determination of residual stress in bulk engineering structures like Ni-based superalloys can be conducted by measuring the lattice strain with penetrating neutron diffraction. The state-of-the-art engineering diffraction beamline VULCAN at the Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) provides the critical capability to evaluate the residual strain/stress relaxation in engineering component thanks to the high flux and event data features. By the means of residual stress/strain calculation, it is critical to accurately determine the stress-free lattice spacing d₀, which can be altered by the change of chemistry, unrelieved stress, and measurement scheme. Here we reported d₀ determination for determining residual stress relaxation and distribution in Alloy 718 superalloys after different quenching treatments. Selection of locations for d₀ measurement was discussed by considering the neutron path, attenuation and sample alignment. A dynamic d₀ that resulted from atom diffusion and chemistry change was estimated as function of time for the in-situ relaxation characterization. It demonstrated how the dynamic d₀ values may influence on the strain calculation in different thermally treated samples. The results highlight the importance of dynamic d₀ for in-situ relaxation involving chemical changes and provide guidance to the dynamic d₀ measurement and simulation.

36 MATERIALS SCIENCE↗

Determination of particle-dependent light response for defining detector response functions

This study comprehensively characterizes two scintillation detectors, an organic deuterated liquid and a stilbene crystal, concerning their response to charged particles such as electrons, protons, alphas, and carbon nuclei. The Birks function was used to determine the detectors’ response to charged particles, enabling the determination of particle-dependent light responses. The particle-dependent light characterization was used to determine detector response functions (DRF) using Geant in combination with Gamma Detector Response and Analysis Software (GADRAS). These DRFs enhance GADRAS by enabling full spectral analysis functionality for previously underrepresented detector materials. Additionally, neutron-specific DRFs are determined for neutron energy spectrum unfolding applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

General-Purpose Bayesian Tensor Learning With Automatic Rank Determination and Uncertainty Quantification

A major challenge in many machine learning tasks is that the model expressive power depends on model size. Low-rank tensor methods are an efficient tool for handling the curse of dimensionality in many large-scale machine learning models. The major challenges in training a tensor learning model include how to process the high-volume data, how to determine the tensor rank automatically, and how to estimate the uncertainty of the results. While existing tensor learning focuses on a specific task, this paper proposes a generic Bayesian framework that can be employed to solve a broad class of tensor learning problems such as tensor completion, tensor regression, and tensorized neural networks. We develop a low-rank tensor prior for automatic rank determination in nonlinear problems. Our method is implemented with both stochastic gradient Hamiltonian Monte Carlo (SGHMC) and Stein Variational Gradient Descent (SVGD). We compare the automatic rank determination and uncertainty quantification of these two solvers. We demonstrate that our proposed method can determine the tensor rank automatically and can quantify the uncertainty of the obtained results. We validate our framework on tensor completion tasks and tensorized neural network training tasks.

Bayesian inference↗

Sequencing and Analysis of the Sex Determination Region of Populus trichocarpa

The ages and sizes of a sex-determination region (SDR) are difficult to determine in non-model species. Due to the lack of recombination and enrichment of repetitive elements in SDRs, the quality of assembly with short sequencing reads is universally low. Unique features present in the SDRs help provide clues about how SDRs are established and how they evolve in the absence of recombination. Several Populus species have been reported with a male heterogametic configuration of sex (XX/XY system) mapped on chromosome 19, but the exact location of the SDR has been inconsistent among species, and thus far, none of these SDRs has been fully assembled in a genomic context. Here we identify the Y-SDR from a Y-linked contig directly from a long-read PacBio assembly of a Populus trichocarpa male individual. We also identified homologous gene sequences in the SDR of P. trichocarpa and the SDR of the W chromosome in Salix purpurea. We show that inverted repeats (IRs) found in the Y-SDR and the W-SDR are lineage-specific. We hypothesize that, although the two IRs are derived from the same orthologous gene within each species, they likely have independent evolutionary histories. Furthermore, the truncated inverted repeats in P. trichocarpa may code for small RNAs that target the homologous gene for RNA-directed DNA methylation. These findings support the hypothesis that diverse sex-determining systems may be achieved through similar evolutionary pathways, thereby providing a possible mechanism to explain the lability of sex-determination systems in plants in general.

59 BASIC BIOLOGICAL SCIENCES↗

Advancing Molecular Weight Determination of Lignin by Multi-Angle Light Scattering

Due to the complexity and recalcitrance of lignin, its chemical characterization is a key factor preventing the valorization of this abundant material. Multi-angle light scattering (MALS) is becoming a sought-after technique for absolute molecular weight (MW) determination of polymers and proteins. Lignin is a suitable candidate for MW determination via MALS, yet further investigation is required to confirm its absolute MW values and molecular size. Studies aiming to break down lignin into a variety of renewable products will benefit greatly from a simple and reliable determination method like MALS. Recent pioneering studies, discussed in this review, addressed several key challenges in lignin’s MW characterization. Nevertheless, some lignin-specific issues still need to be considered for in-depth characterization. This study explores how MALS instrumentation manages the complexities of determining lignin’s MW, e.g., with simultaneous fractionation and fluorescence interference mitigation. Additionally, we rationalize the importance of a more detailed light scattering analysis for lignin characterization, including aspects like the second virial coefficient and radius of gyration.

differential refractive index increment↗

Comparison of fluence-rate determination techniques for the Advanced Test Reactor-Critical Facility

A technique using small, enriched uranium-aluminum alloy monitors to measure fission rates in fuel plate assembly reactors was developed at the Idaho National Laboratory Radiation Measurements Laboratory in support of Advanced Test Reactor Critical (ATR-C) Facility irradiations. Previous measurements were performed to determine the correlation between the beta-particle activity and the fission rate in the U-Al monitors following irradiation. The American Society for Testing and Materials (ASTM) has established a standard practice E704 for determining neutron fluence rate by radioactivation of depleted uranium by measuring the concentration of fission-products in irradiated uranium monitors. Rather than measuring the beta-particle decay from fission-products, the decay rate of fission-products is determined by gamma-ray spectroscopy. The feasibility of using a method adapted from the ASTM standard practice E704 was investigated for ATR-C irradiations and compared to the present method by analyzing a subset of 21 monitor wires using both methods. The resulting calculated fission rates agreed with an average standard deviation of 7.45%, within the average combined measurement error of 9.05%. Practical considerations such as expected fluence-rates, sample activity, and counting-time were compared between the two methods and the sources of error for each method were investigated. Quality assurance measurements utilizing the modified ASTM standard method are recommended for future test irradiation, but gross-beta-particle counting remains the most practical solution for ATR-C fluence-rate determination.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Methods and materials for determination of distribution coefficients for separation materials

Methods and materials for determining the affinity of separation materials for targeted species are described. A composite separation medium is described that combines a separation material such as an ion exchange material or a sorbent with an SERS substrate. Methods and materials can be utilized to determine the distribution coefficient of a species for a separation material after running a single separation protocol followed by examination of the separation material of the protocol according to SERS. Disclosed methods can be utilized to determine the affinity of existing separation materials for targeted species as well as to determine the affinity of newly engineered separation materials to characterize species.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Machine Learning-Based PV Reserve Determination Strategy for Frequency Control on the WECC System: Preprint

Frequency control from Photovoltaic (PV) plants has great potential to address the frequency response challenge of the power system with high renewable penetration. However, using model-based approaches to determine the optimal PV headroom reserve requires significant online computation and is intractable for an interconnection level system. This paper proposes a machine learning based strategy, that is suitable for real-time operation, to determine the optimal PV reserve for frequency control. The proposed machine learning algorithm is trained and tested on 1,987 offline simulations of a 60% renewable penetration Western Electricity Coordinating Council (WECC) system. Furthermore, the proposed reserve determination strategy is applied on a realistic one-day operation profile of the WECC system and demonstrates over 40% PV headroom saving compared to a conservative approach. It is evident that the proposed strategy can efficiently and effectively determine the optimal PV frequency control reserve for realistic interconnection systems.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Salt mass determination by 22 Na-based radioactive tracer dilution of a highly radioactive molten salt system for pyroprocessing spent oxide nuclear fuels

To demonstrate the feasibility of the 22 Na-based radioactive tracer dilution (RTD) for determining the total salt mass in a 60-kg oxide reduction (OR) system at Idaho National Laboratory (INL) for pyroprocessing spent oxide nuclear fuels, a LiCl- 22 NaCl tracer salt was prepared and spiked to the OR vessel, and salt samples were analyzed by gamma spectroscopy. Due to the high radioactivity (around 10 mCi/g) of the OR salt, mainly from 137 Cs, traditional gamma spectroscopy methods, which typically involve diluted salt samples, was not effective for analyzing the RTD samples. Since the 22 Na tracer radioactivity was very low, undiluted samples were necessary to detect the small amount of 22 Na tracer. Here, despite the high gamma radioactivity of the OR salt, increasing the detector-sample distance from 20 cm to 40 cm during gamma spectroscopy allowed the detection of radioactivity as low as 0.12 µCi/g 22 Na. The preparation of the 22 NaCl-LiCl tracer salt suitable for spiking into the OR salt was successful, and the mass determined by RTD was consistent with that estimated by salt level measurement. Therefore, the 22 Na-based RTD technique for total mass determination of the 60-kg molten salt system for OR is feasible, though more development work, particularly in the improving the uncertainty, is needed .

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INTERFACES. A Program for Determining the 3D Structures of Surfaces Sites Using NMR Data

Dynamic nuclear polarization surface enhanced NMR spectroscopy has enabled the determination of high-resolution structures from surface-supported molecules, including singlesite heterogeneous catalysts. Structure determinations have largely mimicked the approaches used in biomolecular NMR spectroscopy, namely, using distance measurements to constrain a conformational search. These early demonstrations made use of purpose-built software, which has limited the adoption of the technique. Herein, we describe the open-source program INTERFACES (Interpret NMR to Elucidate or Reconstruct the Full Atomistic Configurations of External Surfaces) which automates the analysis of RE(SP)DOR data as well as the structure determination for surface sites. Distances, angles, dihedral angles, complex orientation, and distance from the support can all be sampled to find all structures that agree with the experimental data. A χ 2 metric is used to define the error ranges of the REDOR fits and produce structures with an arbitrary level of confidence. Structural solutions are then provided as both overlays and ORTEP-like probability ellipsoids.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atomic structures determined from digitally defined nanocrystalline regions

Nanocrystallography has transformed our ability to interrogate the atomic structures of proteins, peptides, organic molecules and materials. By probing atomic level details in ordered sub-10 nm regions of nanocrystals, scanning nanobeam electron diffraction extends the reach of nanocrystallography and in principle obviates the need for diffraction from large portions of one or more crystals. Scanning nanobeam electron diffraction is now applied to determine atomic structures from digitally defined regions of beam-sensitive peptide nanocrystals. Using a direct electron detector, thousands of sparse diffraction patterns over multiple orientations of a given crystal are recorded. Each pattern is assigned to a specific location on a single nanocrystal with axial, lateral and angular coordinates. This approach yields a collection of patterns that represent a tilt series across an angular wedge of reciprocal space: a scanning nanobeam diffraction tomogram. Using this diffraction tomogram, intensities can be digitally extracted from any desired region of a scan in real or diffraction space, exclusive of all other scanned points. Intensities from multiple regions of a crystal or from multiple crystals can be merged to increase data completeness and mitigate missing wedges. It is demonstrated that merged intensities from digitally defined regions of two crystals of a segment from the OsPYL/RCAR5 protein produce fragment-based ab initio solutions that can be refined to atomic resolution, analogous to structures determined by selected-area electron diffraction. In allowing atomic structures to now be determined from digitally outlined regions of a nanocrystal, scanning nanobeam diffraction tomography breaks new ground in nanocrystallography.

36 MATERIALS SCIENCE↗

True molecular conformation and structure determination by three-dimensional electron diffraction of PAH by-products potentially useful for electronic applications

The true mol­ecular conformation and the crystal structure of benzo[e]di­naphtho­[2,3-a;1',2',3',4'-ghi]fluoranthene, 7,14-di­phenyl­naphtho­[1,2,3,4-cde]bis­anthene and 7,16-di­phenyl­naphtho­[1,2,3,4-cde]heli­anthrene were determined ab initio by 3D electron diffraction. All three mol­ecules are remarkable polycyclic aromatic hydro­carbons. The mol­ecular conformation of two of these com­pounds could not be determined via classical spectroscopic methods due to the large size of the mol­ecule and the occurrence of multiple and reciprocally connected aromatic rings. The mol­ecular structure of the third mol­ecule was previously considered provisional. These com­pounds were isolated as by-products in the synthesis of similar products and were at the same time nanocrystalline and available only in very limited amounts. 3D electron diffraction data, taken from submicrometric single crystals, allowed for direct ab initio structure solution and the unbiased determination of the inter­nal mol­ecular conformation. Detailed synthetic routes and spectroscopic analyses are also discussed. Based on many-body perturbation theory simulations, benzo[e]di­naphtho­[2,3-a;1',2',3',4'-ghi]fluoranthene may be a promising candidate for triplet–triplet annihilation and 7,14-di­phenyl­naphtho­[1,2,3,4-cde]bis­anthene may be a promising candidate for inter­molecular singlet fission in the solid state.

36 MATERIALS SCIENCE↗