Search NASA⌕ Search

SEARCH · Search NASA

Results for “DOWNSTREAM FLOW”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Results of the third Marine Ice Sheet Model Intercomparison Project (MISMIP+)

We present the result of the third Marine Ice Sheet Model Intercomparison Project, MISMIP+. MISMIP+ is intended to be a benchmark for ice-flow models which include fast sliding marine ice streams and floating ice shelves and in particular a treatment of viscous stress that is sufficient to model buttressing, where upstream ice flow is restrained by a downstream ice shelf. A set of idealized experiments first tests that models are able to maintain a steady state with the grounding line located on a retrograde slope due to buttressing and then explore scenarios where a reduction in that buttressing causes ice stream acceleration, thinning, and grounding line retreat. The majority of participating models passed the first test and then produced similar responses to the loss of buttressing. We find that the most important distinction between models in this particular type of simulation is in the treatment of sliding at the bed, with other distinctions – notably the difference between the simpler and more complete treatments of englacial stress but also the differences between numerical methods – taking a secondary role.

58 GEOSCIENCES↗

Financial Analysis of the 2019 Glen Canyon Dam Bug Flow Experiment

This report was prepared by Argonne National Laboratory (Argonne) in support of a financial analysis of the Glen Canyon Dam (GCD) flow experiment that was intended to support downstream macroinvertebrate production that are a primary food supply for fishes in the Colorado River. Also known as “bug flow” experiments, these experimental water releases were conducted on the weekends and holidays from the beginnings of May 2019 through the end of August 2019. This analysis was funded by the Colorado River Storage Project (CRSP) Office of the U.S. Department of Energy’s Western Area Power Administration (WAPA). CRSP markets electricity produced by hydroelectric facilities collectively known as the Salt Lake City Area Integrated Projects including dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande Rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming. Staff members in Argonne’s Energy Systems Division prepared this technical memorandum with assistance from WAPA’s CRSP and Energy Marketing and Management Offices (EMMO).

13 HYDRO ENERGY↗

Financial Analysis of the 2020 Macroinvertebrate Production Flow Experiment at Glen Canyon Dam

This report was prepared by Argonne National Laboratory (Argonne) in support of a financial analysis of the Glen Canyon Dam (GCD) flow experiment that was intended to support downstream macroinvertebrate production that are a primary food supply for fishes in the Colorado River. Also known as “bug flow” experiments, these experimental water releases were conducted on the weekends and holidays from the beginnings of May 2020 through the end of August 2020. This analysis was funded by the Colorado River Storage Project (CRSP) Office of the U.S. Department of Energy’s Western Area Power Administration (WAPA). CRSP markets electricity produced by hydroelectric facilities collectively known as the Salt Lake City Area Integrated Projects including dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande Rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming. Staff members in Argonne’s Energy Systems Division prepared this technical memorandum with assistance from WAPA’s CRSP and Energy Marketing and Management Offices (EMMO).

13 HYDRO ENERGY↗

Financial Analysis of the 2022 Macroinvertebrate Production Flow Experiment at Glen Canyon Dam

This report was prepared by Argonne National Laboratory (Argonne) in support of a financial analysis of the Glen Canyon Dam (GCD) flow experiment that was intended to support downstream macroinvertebrate production that are a primary food supply for fishes in the Colorado River. Also known as “bug flow” experiments, these experimental water releases were conducted on the weekends and holidays from the beginnings of May 2022 through the end of August 2022. This analysis was funded by and prepared for the Colorado River Storage Project (CRSP) Office of the U.S. Department of Energy’s Western Area Power Administration (WAPA). CRSP markets electricity produced by hydroelectric facilities collectively known as the Salt Lake City Area Integrated Projects including dams equipped for power generation on the Colorado, Green, Gunnison, and Rio Grande Rivers and on Plateau Creek in the states of Arizona, Colorado, New Mexico, Utah, and Wyoming. Staff members in Argonne’s Energy Systems and Infrastructure Analysis Division prepared this technical memorandum with assistance from WAPA’s CRSP and Energy Marketing and Management Offices (EMMO).

13 HYDRO ENERGY↗

Computational and Experimental Study of Film-Cooling Effectiveness With and Without Downstream Vortex Generators

Downstream vortex generators that involve a pair of rectangular plates arranged in an open V-shape placed just downstream of each film-cooling hole were shown to create flow and vortical structures that entrain lifted film-cooling flow back to the surface and increase its lateral spreading on the surface (GT2020–14317). In this study, computations and measurements were performed to examine the flow mechanisms this vortex generator induces to improve film-cooling effectiveness of a flat plate with the cooling flow emanating from one row of inclined holes. Parameters studied include blowing ratio (BR = 0.75 and 1.0) and temperature ratio (TR = 1.07 and 1.9). Here, the computational study is based on steady Reynolds-averaged Navier–Stokes (RANS) closed by the shear-stress transport (SST) turbulence model with and without conjugate analysis. The experimental study was conducted by using a conjugate heat transfer test rig with a plenum, where cooling flow is introduced. Measurements made include velocity and temperature profiles upstream and downstream of the film-cooling holes as well as the temperature at several locations on the hot and cold sides of the film-cooled flat plate. The computational study was validated by comparing computed results with those from measurements at BR = 0.75 and 1.0 and TR = 1.9. Computational and experimental results are presented to show the effects of BR and TR on the flow structures and how those structures improve the effectiveness of film cooling with and without the downstream vortex generators and with and without conjugate heat transfer.

42 ENGINEERING↗

The Relationship of Hydrology in the Green River to Colorado Pikeminnow Populations

The Federally listed Colorado Pikeminnow (CP) (Ptychocheilus Lucius) has been declining in the Green River Basin over the last 20 years. Muth et al. (2000) recommended flows and temperatures to benefit endangered fish species downstream of Flaming Gorge Dam on the Green River. The recommendations identified a range of flows during the base flow period (flows that occur after the annual snowmelt runoff period, usually from early summer to the following spring) that were intended to benefit CP. The recommendations indicated that the mean flow for the summer–winter period should be established each year on the basis of anticipated hydrologic conditions, but adjustments could be made if hydrologic conditions change. Flow should gradually decline from peak flow to base flow, with the base flow reached by early to middle summer (depending on hydrologic conditions) and maintained through February. The rate of decline should depend on rates of decline in Yampa River flows and the recommended rates of decline for dam releases. No specific recommendations were made for base flow variation in Reach 1, but variation around the annual mean base flow should be restricted to achieve recommended levels of variation in Reach 2 (middle Green River) (Table 5.5 in Muth et al. 2000). Implementation of the flow and temperature recommendations served as the proposed action for an EIS on Flaming Gorge Dam operations. A Biological Assessment of the impacts on endangered species of implementing the recommendations was prepared and a Biological Opinion that called for development of a study plan to examine the effects of implementation. Projects to address this evaluation were identified in the Green River Study Plan and have been conducted since then. The purpose of the Study Plan was to identify and recommend to the Recovery Program those monitoring or research projects necessary for implementation and evaluation of the flow and temperature recommendations. Those projects included studies to evaluate the anticipated effects of implementing the recommendations (including potential adverse effects identified in the 2006 Biological Opinion) and studies to examine recognized uncertainties of the recommendations. A new recovery program summer base flow study plan was approved in September of 2020 to evaluate stable and elevated summer base flows below Flaming Gorge Dam intended to benefit CP spawning and rearing success. Anecdotal observations suggest CP production may have been higher in years prior to flow restrictions for endangered fish. Based on long-term CP monitoring data in the Green River, Bestgen and Hill (2016) concluded that CP would benefit from higher summer baseflows (1,700-3,000 ft 3 /sec) with flows above or below associated with lower abundance of age-0 CP. Therefore, flexibility in the ROD is currently being utilized to establish higher stable summer base flows in an attempt create more advantageous conditions for spawning and rearing CP. These fish recovery flows are restrictive to WAPA in the summer months, therefore it is necessary to conduct an analysis of historic river data relationships to CP abundance to better understand if the recommended fish flows (elevated and stable base flows) are necessary for fish recovery.

54 ENVIRONMENTAL SCIENCES↗

Self-regulating behavior of hybrid membrane systems as demonstrated in an element-scale forward osmosis-reverse osmosis hybrid system

Hybrid membrane systems can be difficult to design due to the requisite flow rate matching between up- and downstream unit operations. In this work, we use a forward osmosis-reverse osmosis (FO-RO) hybrid system to demonstrate how some membrane systems can exhibit self-regulating behavior due to osmotic coupling. This can reduce the need for complex control systems for flow balancing. We show this behavior using a module-scale test bed that can mimic the behavior of larger scale operations. The system shows permeate flow rate near-convergence between the FO and RO modules after startup or when perturbed by a change in RO module pressure. The behavior of this hybrid system demonstrates that some membrane operations can exploit osmotic interdependence, rather than expensive control systems, to achieve steady state operation.

Debottlenecking↗

Small Reservoirs Offer a New Perspective on Flood Reduction in Large Basins

The flood reduction potential of individual reservoirs within a large river network continuum remains poorly understood due to the complex interplay between reservoir characteristics and network properties. Here we investigate whether a collection of relatively small reservoirs can play a significant role in mediating downstream floods and assess how that role may be influenced by reservoir network properties compared to traditionally known reservoir characteristics. Our unique contribution was the simulation of downstream flood inundation maps alongside peak flows for each of the 81 major reservoirs (6 × 104 to 8 × 109 m3) across 15,000 river reach segments, integrated into a process-based hydrologic model covering a 415,000 km2 region in the Texas Gulf Coast, United States. The three key takeaways from our study are as follows. (a) Smaller reservoirs can substantially reduce downstream flooding, suggesting that inclusion of large reservoirs—the traditional approach in flood risk management studies—may present only a partial picture. (b) Flood reduction by smaller reservoirs is more effective upstream, although this phenomenon may be linked with aridity and overall water availability. (c) While reservoir size matters, it is not the primary factor determining its downstream flood reduction potential; the influence of network properties, such as catchment area, the count of upstream reservoirs, the cumulative maximum storage capacity of upstream reservoirs, and Stream Order (i.e., location), is equally and often more important. The broader impact of our findings goes beyond just floods, providing foundational insights for addressing emerging challenges such as aging dams and river connectivity.

Patel, Krutikkumar [University of Texas at Arlingt↗

Noncontact Flow Rate Using Laser Ultrasonics

Several types of advanced nuclear reactors are cooled with high-temperature liquid metal or molten salt flows. There is a critical need to measure flow velocity in flow channels for test purposes, and eventually in operational reactors. In conventional ultrasonic flow sensors, ultrasonic waves traveling in both the upstream and downstream directions are generated and detected by transducers that must contact the flow channels. A shift in the frequency or transit time between the two ultrasonic waves is measured to determine flow velocity. We describe here an initial effort to apply that sensing concept when the contact transducers are replaced by laser-based generation and detection instrumentation. This noncontact sensing avoids many practical problems associated with contact transducers when implemented on flow channels at high temperature. Laser-based flow monitoring can also be applied to hot-process piping in the geothermal energy, chemical-processing and petroleum-refining industries. Our effort has included theoretical simulation of noncontact laser-based flow monitoring, indicating capability of measuring flow velocities relevant to reactor cooling. It also included a room-temperature experimental demonstration using water as the flow liquid, and indicating capability of measuring flow velocity at a responsivity roughly consistent with simulation predictions. Plans were made for an experimental demonstration at Oregon State University using liquid metal at 110 degrees C.

02 PETROLEUM↗

Thermodynamic modeling of hydrogen fueling process from high-pressure storage tank to vehicle tank

This study develops a hydrogen fueling station (HFS) thermodynamic model that simulates the actual fueling process in which hydrogen is supplied from a high-pressure (HP) storage tank into a fuel cell electric vehicle (FCEV) tank. To make the model as accurate as possible, we use the same components and specifications as in actual HFSs, such as a pressure control valve, a pre-cooling system, and an FCEV tank. After the components and their specifications are set, pressure and temperature profiles are set as the HP tank supply conditions. Based on the pressure and temperature profiles, the model solves for the temperature, pressure, and mass flow rate of hydrogen at each downstream position, including the inside of the vehicle tank. The values predicted by the model are compared with experimental data, and we show that the developed model makes it possible to accurately simulate those values at any position during the fueling process.

08 HYDROGEN↗

Hybrid Ceramic-CMC Vane with EBC for Future Coal Derived Syngas Fired 65% Efficient Turbine Combined Cycle

The efficiency of both simple cycle and combined cycle power generation systems scale with the peak temperature at which the gas exits the combustor to drive the turbine. In conventional systems, a substantial fraction of the total turbine core flow exiting the compressor is diverted downstream to cool metallic turbine hardware rather than power the turbine, much of which is used to cool the first-stage turbine vane. The use of coal derived syngas fuels provides an additional challenge to the lifetime of materials utilized in the turbine, as particulate byproducts created in the coal gasification process melt in the combustion gas, and can subsequently deposit and interact with the turbine hardware. The development of durable hot-section materials capable of operating at temperature well above that of single crystal superalloy airfoil/zirconia based thermal barrier coatings is critical to realizing 65% efficient coal derived syngas fired gas turbine based power systems. To enable higher turbine inlet temperatures while lowering cooling air requirements, United Technologies Research Center (UTRC), the central R&D laboratory supporting UT Pratt & Whitney, led the conceptual design of a new type of ceramic composite turbine hot section materials system. The design focused on a novel hybrid monolithic ceramic-fiber reinforced ceramic matrix composite (CMC) first stage turbine vane having an environmental barrier coating. By utilizing ceramic construction in the turbine hot-section, the core flow normally used to cool metallic components will be substantially reduced, increasing efficiency and reducing emissions. To provide the framework for future demonstration testing, UTRC partnered with University of North Dakota Energy and Environmental Research Center (UNDEERC) to provide a conceptual design for a gasified coal fed high-pressure turbine combustor system designed to mimic the conditions expected in a future 65% fuel to busbar efficient syngas fueled gas turbine based combined cycle. The UNDEERC and UTRC collaborated on characterizing dusts from coal gasifier filtration systems.

10 SYNTHETIC FUELS↗

AGR 5/6/7 Data Qualification Report for ATR Cycles 162B through 168A

This report provides the qualification status of experimental data for the Advanced Gas Reactor (AGR) 5/6/7 fuel irradiation. AGR-5/6/7 was conducted in the Advanced Test Reactor (ATR) at Idaho National Laboratory (INL) in support of development and qualification of tri-structural isotropic (TRISO) low-enriched fuel for use in high temperature gas-cooled reactors. The objectives of the AGR-5/6/7 experiments are to: (i) irradiate reference-design fuel particles to support fuel qualification, (ii) establish operating margins for the fuel beyond normal operating conditions, and (iii) provide irradiated-fuel performance data and irradiated-fuel samples for post-irradiation examination (PIE) and safety testing. The test train contains five separate capsules that were independently controlled and monitored. Each capsule contains multiple 12.51-mm-long compacts filled with low enriched uranium carbide/oxide (UCO) TRISO fuel particles. The primary objective of the AGR-5/6 test (Capsules 1, 2, 4, and 5) is to verify successful performance of the reference-design fuel under normal operating conditions. The AGR-7 test (Capsule 3) was designed to explore fuel performance at higher temperatures to demonstrate the capability of the fuel to withstand conditions beyond normal operating conditions in support of plant design and licensing. AGR 5/6/7 will also provide irradiated-fuel performance data on fission-gas release from failed particles during irradiation. The AGR-5/6/7 capsules were irradiated in the ATR northeast flux trap location. The experiment began on February 16, 2018 and ended on July 22, 2020, spanning nine ATR cycles over two and a half years. Thus, the AGR-5/6/7 fuel compacts were irradiated for a total of 360.9 effective full power days. The AGR 5/6/7 experiment was able to remain in the reactor core during all three Powered Axial Locator Mechanism (PALM) cycles (163A, 165A, and 167A) without overheating its fuel compacts. This report includes irradiation monitoring data from nine ATR Cycles: 162B, 163A, 164A, 164B, 165A, 166A, 166B, 167A, and 168A, as stored in the Nuclear Data Management and Analysis System (NDMAS). During irradiation, data records consisted of instantaneous measurements recorded every minute and provided by text files automatically every 2 hours. The AGR 5/6/7 data streams addressed in this report include thermocouple (TC) temperatures, sweep gas data (flow rates [capsule inlet, outlet, and downstream at detector], pressure, and moisture content), and Fission Product Monitoring System (FPMS) data (release rates and release to birth rate ratios [R/Bs]) for each of the five capsules. A total of 94,989,908 TC temperature and sweep gas data records were received and processed by NDMAS for AGR 5/6/7 irradiation. Of these records, 41,593,387 (or 43.7% of the total) met data collection and accuracy requirements and are labeled as Qualified. A total of 57,746,693 TC temperature readings were captured from 54 installed TCs. Among them, 10,034,676 TC temperature records (only 17.4%) were Qualified and 47,701,371 TC temperatures (or 82.6%) are Failed due to 48 TC failures (63.5%) and due to missing values (19.1%). To assess performance of the operational TCs, analysis of daily correlations between TCs found no evidence of virtual junction failure for any TCs. Analyses on control charts of TC temperature differences revealed trending in TC readings for TC2, 4, 5, and 13 in Capsule 3, but there is no conclusive indication of TC drift failure that caused those trends. Therefore, TC control charts are not used to disqualify TC data, but only for users’ consideration. For sweep gas flow rates, a total of 31,519,747 gas flow records (84.4%) are Qualified for use for AGR-5/6/7 experiment; 5,723,468 gas flow records (15.4%) are Failed due mostly to missing values; and 74,641 high sweep gas flow rates (0.2 %) are Trend. A large number of Failed missing TC temperature and gas flow values were caused by an error in the data output script that outputted a ‘NULL’ value when values were unchanged. This problem was fixed during the outage of Cycle 166B, which led to a substantially decreased number of missing values during the last three cycles. Nonetheless, a large amount of non-missing data remained because of the high data acquisition frequency (1-minute) and still provided sufficient data to effectively monitor the experiment as designed. For FPMS data, NDMAS received and processed fission product release and R/B data for nine ATR cycles, when ATR core reached full power during AGR 5/6/7 irradiation. These data consist of 110,388 release rate records and 110,388 R/B records for the twelve radionuclides (Kr 85m, Kr 87, Kr 88, Kr 89, Kr 90, Xe 131m, Xe 133, Xe 135, Xe 135m, Xe 137, Xe 138, and Xe 139) for each of the five capsules. Equivalent numbers of uncertainty records associated the release rates and R/B values were provided. To date, qualification status of the FPMS data stored in the NDMAS dat

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

The Role of Snowmelt and Subsurface Heterogeneity in Headwater Hydrology of a Mountainous Catchment in Colorado: A Model‐Data Integration Approach

Mountainous headwater streams are sustained by both snowmelt‐driven streamflow and groundwater discharge in the Upper Colorado River Basin. However, predicting headwater stream discharge magnitude and peak flow timing is challenging in mountainous terrains, where snowmelt rates vary with vegetation type and elevation, and heterogeneous subsurface physical properties influence groundwater storage and its release. We used a model‐data integration approach to investigate the roles of snowmelt and subsurface structure in stream discharge and groundwater level. We ran an ensemble of 100 integrated surface‐subsurface hydrologic models for a mountainous headwater catchment near Crested Butte, Colorado, USA. We also evaluated and calibrated these models against observed data sets, including snow depth measurements using distributed temperature probes, stream discharge, and groundwater levels. Calibration with multiple data sources using neural density estimators has further constrained uncertainty in subsurface properties and snowmelt rates. Results indicated that observed slower snowmelt rates in evergreen forests delayed the peak flow and baseflow onset. In upstream areas with lower subsurface permeability, water was stored within the subsurface but was not released as interflow or shallow groundwater flow, and thereby not contributing to downstream streamflow during recession limb periods. Double peaks in groundwater occurred in areas with spatial subsurface heterogeneity, in our case due to the contrast between granodiorite and Mancos shale. These process‐based insights into groundwater and snowmelt dynamics in mountainous headwaters will help improve predictions of headwater hydrology.

Wang, Lijing [University of Connecticut, Storrs, C↗

Model Driven Deception for Defense of Operational Technology Environments

Due to the strong integration of real-world physics, OT deception platforms must operate differently than traditional IT deceptions. For instance, turning off a valve will be detected downstream by other sensors because the flow will reduce and stop. Additionally, controllers and applications leverage data from sensors to send control commands to each other. A believable deception must be integrated with the system to project the effects of events. An attack will likely attempt to control the physical process in a negative manner. To make the attacker believe they are achieving their objective, it must predict the effects of these actions, to a reasonable degree. Our approach to simulating a model to generate realistic decoy behavior is explored including description of two approaches: a physics model-based approach and a data driven approach. The performance of two machine learning techniques are investigated in their ability to learn a good enough model of the physics of the system.

97 MATHEMATICS AND COMPUTING↗

Experimental investigation of turbulent wake flows in a helically wrapped rod bundle in presence of localized blockages

In nuclear sodium fast reactors, bundles of rods are tightly packed into a triangular lattice, enclosed in a hexagonal duct, and each pin is spirally wrapped with a thin wire. Flow blockages can potentially impact the local flow characteristics and heat transfer mechanisms in the bundle due to its small subchannel size. The effects of the blockage on the flow structures and heat transfer mechanisms are important aspects that require an accurate investigation. In this study, the flow-field characteristics in the vicinity of a blockage located in the exterior subchannel of rod bundles with helically wrapped wires were experimentally investigated. The velocity fields in the exterior subchannel were acquired by applying matched-index-of-refraction and time-resolved particle image velocimetry (TR-PIV) techniques for Reynolds numbers of Re 1 = 4000 and Re 2 = 17 000, i.e., equivalent to Rew 1 = 19 600 and Rew 2 = 83 200, respectively, based on the blockage width. The results from the TR-PIV measurements revealed an arch-shaped vortex with a large flow recirculation and a pair of counter-rotating vortices in the wake region downstream of the blockage, which is commonly observed in the wake flow of bluff bodies. The relative lateral distance and angle between the two vortices decreased when the Reynolds numbers increased. Profiles of maximum turbulence intensity along the shear layers illustrated the transition process including the growth, peak, and decay along the flow direction. From the spectral analysis of the turbulent velocities extracted at points along the shear layer, the Strouhal numbers ( St ) representing the vortex shedding frequency were found to be St = 0.25 and St = 0.56 for the left and right shear layers, respectively. Characteristics of shear layers generated by the blockage in the exterior subchannel were investigated via the two-point cross correlation of fluctuating velocities. The patiotemporal cross correlations of turbulent velocities, computed at points in the region where the left shear layer exhibited rolling effects and vortex breakdowns, were considerably wider and longer. The convection velocity U c was estimated to be ~0.82 U m to 0.93 U m . Proper orthogonal decomposition (POD) analysis was applied to the instantaneous velocity fields to extract the statistically dominant flow structures. It was found that POD modes 2–3 and 4–5 formed the pair modes when the corresponding POD temporal coefficients depicted sinusoidal shapes and exhibited nearly circular orbits in the phase space. Spectral analysis of the POD temporal coefficients confirmed the vortex shedding frequencies detected in the analysis of turbulent velocities.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Pressure Response Optimization of an Eddy Current-Driven Flyer Plate Valve for the ITER Shattered Pellet Injection System

One technique for mitigating disruptions in a tokamak is shattered pellet injection (SPI). SPI is a process in which a large solid pellet consisting of deuterium, neon, or argon is desublimated in a pipe gun barsrel and launched downstream. Pellets are shattered just before entering the plasma by an impact with an angled tube. Injection of these materials into the plasma radiates stored thermal energy, limits current decay rates, suppresses the generation of runaway electrons, and dissipates runaway electrons if necessary. A critical element of the SPI system is a fast-acting valve that releases high-pressure gas to dislodge and accelerate pellets directly, or indirectly via a mechanical punch. A prototype valve sized for the ITER SPI system has been designed and fabricated. A pulsed high-voltage power supply energizes the valve’s internal magnetic coil, which induces eddy currents in the adjacent flyer plate resulting in a repulsive force between the flyer plate and the coil. The flyer plate action lifts a valve seat, allowing high-pressure gas to flow from the valve plenum to the downstream (breech) location of the pellet or mechanical punch. All of the valve’s internal components are designed to operate in ITER-level static background magnetic fields. Here, a study was conducted to optimize the downstream pressure response for a range of valve sizes and operating pressures. In particular, the study analyzes the breech pressure response associated with varying plenum pressures as well as varying breech volumes. A computational fluid dynamics simulation was built in STAR-CCM+ and validated against data from laboratory experiments. The resulting simulation outputs, in the form of downstream responses for a variety of initial plenum pressures and breech volumes, will be used as a complement to experimental data to ensure the pressure pulse is suitable for pellet survivability. These data, combined with studies on pellet shear strength and shock response, will be applied to optimization of overall operating parameters of the ITER SPI system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hydrokinetic Energy Conversion by Flow-Induced Oscillation of Two Tandem Cylinders of Different Stiffness

Abstract The vortex-induced vibration for aquatic clean energy (VIVACE) converter harnesses hydrokinetic energy by enhancing flow-induced oscillations (FIOs) of elastically supported rigid cylinders in a river, tide, or ocean current. The harnessing power depends on the intensity of the oscillation, which is a consequence of the flow–structure interaction. The inflow condition for the downstream (second) cylinder is slowed down and perturbed by the upstream (first) cylinder, due to the shielding effect. Therefore, the optimal structural parameters, i.e., stiffness and damping ratio, for the second cylinder may be different from the first cylinder, in terms of energy harnessing. To improve the performance of the VIVACE converter, a series of experiments are conducted in a recirculating water channel, with various stiffness combinations of two cylinders in tandem. Results show that the stiffness of the second cylinder, K2, does not affect the energy harnessing power in vortex-induced vibration (VIV) occurring at low speeds, because the oscillation of the downstream cylinder in this velocity range is completely dominated by the wake of the upstream cylinder. K2 has a great influence on the harnessing power at higher velocities in the transition region from VIV to galloping and in galloping. Changing K2 onsets and enhances galloping at lower flow velocity and harnesses up to 110% more energy than the case of K1 = K2.

Engineering↗

A Multiscale Simulation Study of the Effects of Nantucket Island on Atmospheric Boundary Layer Flow

Multiscale atmospheric simulations were conducted to investigate how Nantucket Island modifies the marine atmospheric boundary layer (ABL) flow, how the mechanisms responsible are represented in mesoscale versus large-eddy simulation (LES) domains, and potential impacts on wind energy production downstream, in moderate and high wind speed cases. Here, to isolate the effects of the island, each case study was simulated (i) with and without island topography included and (ii) with observed versus spatially uniform sea surface temperature (SST) values, the latter removing the influence of spatial variability in SST, while also enabling the examination of how the island effects vary with near-surface thermodynamic stability over the surrounding ocean. Island effects were found to be strongest during daytime heating, which generates convective rolls that redistribute momentum vertically over the island and downstream. Colder SSTs and weaker winds strengthen these rolls and extend their influence. Flow statistics within a representative wind turbine rotor-swept area downstream show that while vertical momentum redistribution enhances near-surface wind speeds, those aloft decrease, resulting in minimal net change to rotor-equivalent wind speed and slightly reduced vertical shear. Comparisons of mesoscale and LES domains reveal that both capture the roughness-driven near-surface slowdown, but mesoscale models underestimate vertical momentum transport compared to LES, which explicitly resolves convective rolls. Increasing LES resolution beyond the grid spacing required to begin capturing the largest convective roll structures ∼ O(100) m yields minimal additional momentum transport but increases resolved turbulence kinetic energy, relevant for stress loading.

Atmosphere-land interaction↗