Search NASA⌕ Search

SEARCH · Search NASA

Results for “DRY HEAT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Residential segregation and outdoor urban moist heat stress disparities in the United States

The combined impact of urbanization-induced warming and drying on large-scale heat stress disparities remains unknown, with multicity studies using satellite-derived land surface temperature as a proxy for these disparities. Here, using high-resolution urban-resolving numerical model simulations for 2014–2018, we find pervasive disparities in all-sky average maximum summertime air temperature and moist heat stress metrics across US cities, with higher outdoor heat stress exposure in poorer and primarily non-white census tracts. Ninety-four percent of the US urban population (228 million) live in cities where heat stress burdens the poor, with heat stress inequities between white and non-white populations strongly associated with residential segregation. Similarly, historically redlined neighborhoods show higher heat stress than their non-redlined counterparts, demonstrating how historical segregation relates to present-day environmental inequalities. Our results provide quantitative estimates of physiologically relevant heat stress disparities at the US national scale and highlight potential biases when using satellites as a proxy for these.

54 ENVIRONMENTAL SCIENCES↗

Hydrometeorological sensitivities of net ecosystem carbon dioxide and methane exchange of an Amazonian palm swamp peatland

Here, we report ecosystem-scale CO 2 and CH 4 flux observations for an Amazonian palm swamp peatland over a two-year period in relation to hydrometeorological forcings. Seasonal and short-term variations in hydrometeorological forcing had a strong effect on carbon dioxide and methane fluxes. High air temperature and vapor pressure deficit exerted an important limitation on photosynthesis during the dry season, while latent heat flux appeared to be insensitive to these climate drivers. Evidence from light-response analyses and flux partitioning support that photosynthetic activity was downregulated during dry conditions, while ecosystem respiration was either inhibited or enhanced depending on water table position. The cumulative net ecosystem carbon dioxide exchange indicated that the peatland was a significant carbon dioxide sink ranging from –465 (–279 to –651) g C m -2 y -1 in 2018 to –462 (–277 to –647) g C m -2 y -1 in 2019. The forest was a methane source of 22 (20 to 24) g C m -2 y -1 , similar in magnitude to other tropical peatlands and larger than boreal and arctic peatlands. Furthermore, the annual carbon budget of this Amazonian palm swamp peatland appears to be a major carbon sink under current hydrometeorological conditions, but evidence indicates that the sink strength is vulnerable to future climate change.

54 ENVIRONMENTAL SCIENCES↗

Contrasting effects of lake breeze and urbanization on heat stress in Chicago metropolitan area

This study used the latest Weather Research and Forecasting (WRF) model coupled with multi -layer urban canopy models to investigate contrasting effects from urbanization and lake breeze on summer heat stress over the Chicago metropolitan area (CMA). Comparisons between the model and in situ observations show that this coupled modeling system better captures urban locations' diurnal pattern of surface air temperature, skin temperature and relative humidity, with root mean square error reduced from 1.58 to 1.80 degrees C to 1.14-1.31 degrees C, 3.11-3.55 degrees C to 1.81-2.21 degrees C, and 10.73-11.35% to 7.84-8.60%, respectively, compared to WRF without coupling the urban canopy models. Two sensitivity experiments were conducted to isolate the influence of lake breeze and urbanization: one replaced the urban land use with cropland over the CMA, and the other filled all of Lake Michigan with cropland. Three different heat stress indices were computed to assess the uncertainties of heat stress response to changes in air temperature, relative humidity, and wind conditions. Results show that, when the lake has the largest cooling effect on air temperature, it also increases the relative humidity the most, and vice versa for urban warming and drying effects. Urbanization intensifies heat stress at night, and extends the heat caution period by up to 4 h over inland urban grids; the lake breeze relieves heat stress during afternoon (when the heat stress is the worst), and shortens the heat caution period by 1-3 h over inland urban grids and 3-4 h over coastal urban grids. In conclusion, the intensification of heat stress over the CMA due to urbanization is more than four times greater than the reduction from the lake breeze in the late afternoon and evening.

54 ENVIRONMENTAL SCIENCES↗

Temperature-Time Modeling of Spent Fuel Cladding in Dry Storage Casks

This report uses thermal and decay heat modeling to investigate spent fuel performance and the potential for cladding to anneal in dry storage conditions. Annealing is an important feature to investigate in SNF cladding because it has a direct relationship to cladding response in storage, transportation and disposal conditions. Annealed cladding may have lower strength than unannealed cladding, however its increased ductility would provide better protection against rupture in high strain rate situations such as severe accidents. These consequences are the driver for this work however are outside of the scope of this report. The modeling focused on three representative storage systems, the TN-32B, MAGNASTOR with TSC-37 canister, and NUHOMS AHSM with a 32PTH2 canister. This covers the vertical dual-purpose, vertical ventilated and horizontal ventilated casks respectively. Decay heat modeling using high and low enrichment assemblies was used to bound the decay heat curves that might be expected in dry storage. To bound the temperature relationship, the storage casks were modeled starting at the design basis heat loads with heat decaying through time. Although the results are bounding there is not an attempt to maximize conservatism, rather the intent to form a reasonable upper limit on temperature that will be broadly applicable to the U.S. cask fleet. This will allow materials testing to focus on relevant conditions for annealing that may affect the U.S. spent fuel inventory. The results show a clear dependence on heat load pattern in time in Figure S-1 and Figure S-2. This dependence is due to the different assembly decay heat curves for different assemblies in preferentially loaded casks. It shows the need for careful decay heat modeling when examining in service fuel temperatures that are less than the cask design basis heat load. The body of the report shows percent cladding cutoffs of 300°C and 350 °C as well. These results can be used to inform testing and conclusions about cladding performance through time and the potential for cladding annealing during dry storage.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area: Preprint

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs drilled in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated including a single, double, and multi-lateral design. The subsurface within area is characterized by deep, hot (> 200degreesC) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lies within a target depth of 6 km where temperatures are estimated to approach 300degreesC. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down technoeconomic analysis model. The results show that the performance and cost optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60degreesC/km. By injecting 20 degreesC-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth can be achieved, resulting in an LCOE and LCOH of $136/MWh and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Thermal and Well Flow Performance of Closed-Loop Geothermal in the Wattenberg Area

Closed-loop geothermal systems provide an alternative to resource-constrained hydrothermal systems and stimulation-intensive enhanced geothermal systems. In this work, we apply the slender-body theory (SBT) model, to simulate the well flow and heat transfer performance of U-loop well designs in the Wattenberg area of the Denver-Julesburg Basin. Three U-loop well patterns are investigated, including a single-, double-, and multi-lateral design. The subsurface within the area of interest is characterized by deep, hot (> 200 degrees C) igneous/metamorphic basement rock underlying multiple sedimentary formations. The lateral section(s) of the U-loop lie(s) within a target depth of 6 km, where temperatures are estimated to approach 300 degrees C. As a base case, conduction-only heat transfer is investigated through simulations with the SBT model within U-loops with open-hole laterals that exchange heat directly with the hot, dry rock using water as a working fluid. The utilization of supercritical CO2 as a heat transfer fluid is also considered. For each scenario, the system performance in terms of annual heat production and temperature profile over a 20-year project lifetime are assessed. Also, the levelized costs of heat and electricity (LCOH and LCOE) are determined using a top-down techno-economic analysis model. The results show that the performance- and cost-optimized U-loop design is one having an injection-production well spacing of 1,000 meters with ten 50-meter-spaced laterals that traverse a subsurface system with a temperature gradient of 60 degrees C/km. By injecting 20 degrees C-water at a rate of 60 kg/s through this loop, an average heat production of 19 MWth (i.e., 2.2 MWe net plant output) can be achieved, resulting in an LCOE and LCOH of $136/MWhe and $1.53/GJ, respectively, over a 20-year project life.

closed-loop geothermal↗

Next Generation System Analysis Model Recently Added Features and Future Plans - Abstract

The Nuclear Waste Policy Act of 1982, as amended (NWPA 1982), established the federal government’s responsibility to accept spent nuclear fuel (SNF) and high-level radioactive waste (HLW) from waste owners and generators for ultimate disposition. SNF generated by the current fleet of commercial nuclear reactors is being stored at the reactor sites in spent fuel pools (SFPs) and in dry independent spent fuel storage installations (ISFSIs). The US Department of Energy Office of Nuclear Energy (DOE-NE) is developing an Integrated Waste Management Program (IWMP) comprising a suite of options and supporting analyses to enable future informed choices. The IWMP is applying integrated waste management system architecture analysis, system engineering, and decision analysis principles to inform potential future decisions regarding potential nuclear waste management system architectures. Architecture analyses of the IWM system are being conducted to support the future deployment of a comprehensive system for managing nuclear waste that considers all major aspects of the back end of the nuclear fuel cycle (i.e., transportation, storage, and disposal). The Next Generation System Analysis Model (NGSAM) is an agent-based simulation software tool designed for the express purpose of modeling the IWM system. NGSAM imports data from the Oak Ridge National Laboratory (ORNL) Unified Database (e.g., historic assembly information, thermal profiles for assembly heat, at-reactor dry storage loadings) to ensure that the simulation initializes with a realistic representation of the state of commercial SNF in the United States. Recent major enhancements that have been implemented into NGSAM since NGSAM was last presented at the WM2019 conference include: • Tracking of railroad escort and buffer car acquisition. • Addition of heavy haul and barge routes for some sites, as well as support for user-defined inter-modal routes. • Updates to the logic that checks the thermal maps prior to package transport. • Addition of an allocation method that predicts when reactor sites will pack assemblies from their pools for dry storage and allocates packages to those reactor sites in the preceding periods, favoring direct transport packages and reducing the number of packages that reactor sites pack for dry storage at their ISFSIs. • Addition of reactor site family operational limits, which are used to limit the number of loads from the pool and from dry storage at a given reactor site per year. • Support has been added for multiple canister loading maps and packages having multiple compatible transportation overpacks. • Updates in the handling of non-commercial fuel, including a new database containing data to support the updates. • Support for repackaging at reactor sites. • Implementing additional output reports or modifying existing reports. • User edits can now be created and edited via the NGSAM website. • Ability to load packages for dry storage at ISF pools. • Same-type package blending at DOE sites. • Support for multi-mode transloading at reactor sites. These new features have improved NGSAM capabilities and/or improve the user experience with the model and will be discussed in more detail. The initial NGSAM requirements for advanced reactor fuels, reprocessing, treatment, and conditioning are preliminary and are described at a high level in this paper: analysts will provide more specific requirements to the NGSAM team in the future. Additionally, there are many data needs associated with modeling advanced reactors in NGSAM, but many of the data or plans are still in progress and/or yet to be fully defined. However, this document describes an initial exploration of the data relevant to this program. Advanced reactor data will likely require revision as concepts evolve and new considerations are made. This is a technical paper that does not take into account contractual limitations or obligations under the Standard Contract for Disposal of Spent Nuclear Fuel and/or High-Level Radioactive Waste (Standard Contract) (10 CFR Part 961). For example, under the provisions of the Standard Contract, spent nuclear fuel in multi-assembly canisters is not an acceptable waste form, absent a mutually agreed to contract amendment. To the extent discussions or recommendations in this paper conflict with the provisions of the Standard Contract, the Standard Contract governs the obligations of the parties, and this paper in no manner supersedes, overrides, or amends the Standard Contract. This paper reflects technical work which could support future decision making by DOE. No inferences should be drawn from this paper regarding future actions by DOE, which are limited both by the terms of the Standard Contract and Congressional appropriations for the Department to fulfill its obligations under the Nuclear Waste Policy Act including licensing and construction of a spent nuclear fuel repository.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Assessment of lignite upgrade and hydrogen evolution via electrolysis

Lignite, considered as the lowest-rank coal, accounts for 45% of the total coal resources worldwide, and its low carbon and high ash contents limit its large-scale application. In order to upgrade lignite effectively, a modified coal electrolytic cell (MCEC) was designed, built, and then evaluated for lignite upgrade and hydrogen production through electrolysis, and the operating conditions were optimized. The results show that the performance of the MCEC outperformed the previous coal electrolytic cell (CEC). The operating temperature and iron concentration significantly impact the average current density per milligram of catalyst (ACDMC). The content of dry fixed carbon and heating value increased by 20.9% (wt%) and 8.15%, respectively, in electrolyzed lignite compared with raw lignite. Besides, 71.5% ash and 39.6% mercury were removed from raw lignite after electrolysis, which is the first report. The Faradaic efficiency (FE) for hydrogen evolution reached 99% using MCEC. In addition, the analysis of spectroscopy methods (SEM, EDX, FTIR, and XRD) revealed that the lignite particles were cracked; the oxygen-containing functional groups increased; the minerals of quartz and hematite formed on the surface of lignite particles after electrolysis. Furthermore, the facts indicate that electrolysis of lignite is a competitive approach for lignite upgrade and hydrogen production.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Single Crystalline Na 0.67 Ni 0.33 Mn 0.67 O 2 Positive Electrode Material via Molten Salt Synthesis for Sodium Ion Batteries

P2-layered Na 0.67 Ni 0.33 Mn 0.67 O 2 (NNMO) has emerged as a promising positive electrode material for sodium ion batteries due to its appealing electrochemical properties. Synthesis of polycrystalline NNMO (PC-NNMO) materials through conventional calcination of solid precursors remains the prevailing method, where heating occurs in a dry environment with air or O 2 . On the other hand, the molten salt method, where precursors are submerged in molten salt medium during calcination, emerged in recent years to be a scalable technique for more controlled crystal growth and uniform morphology in a variety of materials. Here, we utilize the molten salt method to synthesize single crystalline NNMO (SC-NNMO) materials with enhanced electrochemical properties. The SC-NNMO material exhibits an initial specific discharge capacity of 95 mAh g –1 at a 0.1C rate, retaining approximately 88.5% of its capacity after 100 cycles over a wide voltage range of 2.0–4.2 V. Furthermore, SC-NNMO maintains a capacity retention of 83.9% after 300 cycles at a 1C rate compared to 66.6% for PC-NNMO, indicating excellent long-term cycling stability. This stability is further confirmed by the performance of an SC-NNMO//hard carbon full cell, which retains 90.3% of its capacity after 200 cycles at 1C within a voltage window of 1.9–4.1 V. The enhancement in stability of the SC-NNMO sample is attributed to the single crystalline structure suppressing the undesired P2–O2 phase transition at high voltage. This study also presents an easy, efficient, and straightforward molten salt process for SC-NNMO material synthesis, offering valuable insights into the potential application of such methodology for the large-scale, cost-effective production of various sodium-layered transition metal oxide positive electrode materials for SIBs.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Greenland Surface Melt Dominated by Solar and Sensible Heating

The Greenland Ice Sheet is the primary source of global Barystatic sea-level rise, and at least half of its recent mass-loss acceleration is caused by surface meltwater runoff. Previous studies on surface melt have examined various thermodynamic and dynamic drivers, yet their contributions are not compared using unified observations. We use decade-long in-situ measurements from automatic weather stations throughout the ablation zone to assess energy components and identify the leading physical processes in this area. Large melt events exceeding 3σ contribute only ~2% to total surface melt since 2007. The day-to-day variability of all melt is dominated by sensible heat exchange (31 ± 7%) and shortwave radiation (28 ± 5%). Sensible and solar heating correlate with the occurrence of dry and fast gravity-driven winds. These katabatic winds increase sensible heating of the surface mainly by enhancing vertical mixing that reduces the temperature inversion. The concomitant low humidity and clear skies yield increased solar heating.

54 ENVIRONMENTAL SCIENCES↗

Balancing moisture and oxygen can match the crystallization dynamics of inert halide perovskite processing

Understanding crystallization in ambient environments is essential for scaling the fabrication of halide perovskite solar cells. Antisolvent-free perovskite deposition offers improved compatibility with high-throughput processing but introduces distinct crystallization dynamics relative to the more ubiquitous use of antisolvents in lab-scale perovskite fabrication. These dynamics are driven by interactions between solutes, solvent and the deposition environment. Using in situ wide-angle X-ray scattering during spin-coating and annealing, we demonstrate how relative humidity (RH) and oxygen, can be tuned to drive polytype evolution during ambient crystallization of formamidinium lead iodide to match that of inert synthesis and achieve comparable film and device quality. In an inert (N 2 ) environment, we find that perovskite films follow a well-established 2H → 3C phase transformation with a short period of coexistence of the 4H and 6H phase during heating. During crystallization in dry air (RH 0%), the added presence of oxygen leads to the dominance of 4H intermediate for an extended duration, establishing a 2H → 4H → 3C pathway. Introducing low humidity (RH 10%) suppresses the 4H phase to a short-lived intermediate above 100 °C, facilitating a more direct transition to the desired 3C phase and almost replicating the crystallization behavior observed under inert conditions. Interestingly, films crystallized under RH 10% show a lower onset temperature for the perovskite 3C phase than under N 2 . At higher humidity (RH 40%), the strong interaction of oxygen and moisture with iodoplumbates appears to stabilize higher order polytypes (4H and 6H). Devices fabricated under RH 10% achieve higher efficiency and enhanced stability compared to those produced under inert atmosphere. These findings provide mechanistic insight into crystallization pathways in different environments and provide a framework to transfer processes from inert to ambient conditions. The results highlight the critical role of controlled humidity in tuning antisolvent-free perovskite crystallization for scalable processing.

Hossain, Maimur [Univ. of California, San Diego, C↗

Chapter 8: Geothermal Energy

Geothermal resources are used at different temperatures for different applications, depending on the resource temperature; applications include power generation, direct heating and cooling, mineral recovery, and energy storage. This chapter focuses on the most prominent applications of geothermal energy today: power generation and direct heating and cooling, specifically, dry steam, flash, and binary technologies. Other topics explored include: direct use of geothermal resources, thermodynamic cycle applications, and the multiple steps and multiple technologies involved in capturing all minerals of interest in a cost-effective way.

cooling↗

Alumina-based filters made via binder jet 3D printing of alumina powder, colloidal silica infiltration, and sintering

Alumina-based, porous filter media was made via a binder jet 3D printing process consisting of an alumina powder printing step with subsequent heating, colloidal silica infiltration, drying, and sintering to consolidate particles yet retain a net open porous microstructure. The composites made were alumina-silica or alumina-mullite, where the silica sintering aid was used to densify and join the alumina particles. The resulting composite structures had open porosities in the 25–31 vol% range as measured by Archimedes density. Pressure drops were measured across the filter media at constant flow rates to compare disc shapes and complex, 3D printed filters based on the N95 design requirements. Complex, 3D-printed alumina composites were produced with acceptable pressure drops for N95 implementation.

36 MATERIALS SCIENCE↗

Sensitivity Analyses of Natural Convection in the AP1000 Passive Containment Cooling System Following LBLOCA Using CFD

The AP1000 power plant has implemented multiple layers of passive safety systems to enhance reactor safety and ensure system integrity during postulated scenarios, such as loss of coolant accident (LOCA) and main steam line break (MSLB). Among these, the passive containment cooling system (PCCS) is a safety-related system designed to prevent the containment from exceeding the design limits of both pressure and temperature following a postulated design basis accident, by transferring heat from the steel containment vessel to the atmosphere. During LOCA, natural air convection plays a vital role in removing heat from the steel containment vessel to the atmosphere. This is integrated with the condensate film from the Passive Containment Cooling Water Storage Tank (PCCWST). Air natural convection is also the only heat removal mechanism after the dry-out of the PCCWST and during the loss of shutdown decay heat removal (LOSDHR) event. Therefore, it is essential to investigate the thermal hydraulics behavior of the containment under transient conditions to ensure its safety and integrity. This paper presents a simplified CFD/ANSYS FLUENT model developed to analyze the impact of different parameters, such as air relative humidity, air temperature, and steel containment temperature, on the natural convection capability to remove the decay heat following LOCA. The model aims to examine the thermal behavior of the containment and provides a comprehensive understanding of the system's natural convection capability during postulated accidents. The results obtained from the model can be used to improve the safety and integrity of the containment system and provide valuable insights for future research in the field.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Prioritizing Transformative Energy Efficiency Technologies in the Pulp and Paper Sector Through Levelized Cost of Conserved Energy

This presentation explores how the U.S. pulp and paper sector can prioritize energy efficiency (EE) technologies using the Levelized Cost of Conserved Energy (LCCE) metric. As mills face market shifts and rising costs, technologies such as advanced drying, membrane concentration, waste heat recovery, and recovery boiler replacements offer potential savings but face economic barriers. LCCE enables consistent comparison of technologies by calculating cost per unit of energy saved, including capital, operating, and potentially non-energy benefits like productivity, maintenance, and safety improvements. Preliminary findings show economies of scale significantly influence recovery boiler replacement feasibility, with larger systems achieving lower LCCE values. Ongoing work incorporates non-energy benefits to provide a more comprehensive cost-effectiveness assessment and guide research, development, and deployment priorities for underutilized and emerging technologies.

Kamath, Dipti [ORNL] (ORCID:0000000278739994)↗

Warming of alpine tundra enhances belowground production and shifts community towards resource acquisition traits

Abstract Climate warming is expected to stimulate plant growth in high‐elevation and high‐latitude ecosystems, significantly increasing aboveground net primary production (ANPP). However, the effects of simultaneous changes in temperature, snowmelt timing, and summer water availability on total net primary production (NPP)—and elucidation of both above‐ and belowground responses—remain an important area in need of further study. In particular, measures of belowground net primary productivity (BNPP) are required to understand whether ANPP changes reflect changes in allocation or are indicative of a whole plant NPP response. Further, plant functional traits provide a key way to scale from the individual plant to the community level and provide insight into drivers of NPP responses to environmental change. We used infrared heaters to warm an alpine plant community at Niwot Ridge, Colorado, and applied supplemental water to compensate for soil water loss induced by warming. We measured ANPP, BNPP, and leaf and root functional traits across treatments after 5 yr of continuous warming. Community‐level ANPP and total NPP (ANPP + BNPP) did not respond to heating or watering, but BNPP increased in response to heating. Heating decreased community‐level leaf dry matter content and increased total root length, indicating a shift in strategy from resource conservation to acquisition in response to warming. Water use efficiency (WUE) decreased with heating, suggesting alleviation of moisture constraints that may have enabled the plant community to increase productivity. Heating may have decreased WUE by melting snow earlier and creating more days early in the growing season with adequate soil moisture, but stimulated dry mass investment in roots as soils dried down later in the growing season. Overall, this study highlights how ANPP and BNPP responses to climate change can diverge, and encourages a closer examination of belowground processes, especially in alpine systems, where the majority of NPP occurs belowground.

54 ENVIRONMENTAL SCIENCES↗

Exergy Analysis of a Convective Heat Pump Dryer Integrated with a Membrane Energy Recovery Ventilator

To increase energy efficiency, heat pump dryers and membrane dryers have been proposed to replace conventional fossil fuel dryers. Both conventional and heat pump dryers require substantial energy for condensing and reheating, while “active” membrane systems require vacuum pumps that are insufficiently developed. Lower temperature dehumidification systems make efficient use of membrane energy recovery ventilators (MERVs) that do not need vacuum pumps, but their high heat losses and lack of vapor selectivity have prevented their use in industrial drying. In this work, we propose an insulating membrane energy recovery ventilator for moisture removal from drying exhaust air, thereby reducing sensible heat loss from the dehumidification process and reheating energy. The second law analysis of the proposed system is carried out and compared with a baseline convective heat pump dryer. Irreversibilities in each component under different ambient temperatures (5–35 °C) and relative humidity (5–95%) are identified. At an ambient temperature of 35 °C, the proposed system substantially reduces sensible heat loss (47–60%) in the dehumidification process, resulting in a large reduction in condenser load (45–50%) compared to the baseline system. The evaporator in the proposed system accounts for up to 59% less irreversibility than the baseline system. A maximum of 24.5% reduction in overall exergy input is also observed. The highest exergy efficiency of 10.2% is obtained at an ambient condition of 35 °C and 5% relative humidity, which is more than twice the efficiency of the baseline system under the same operating condition.

Balaraman, Anand (ORCID:0000000218355788)↗