Fiber Optic Network Signal Integrity Analyzer
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Tracktable is a toolkit for analysis and visualization of the trajectories of moving objects. Its main focus is on air and sea traffic. It can also work with more abstract trajectories such as eye tracking data. We supply a set of core data structures, input/output routines, math and machine learning algorithms that operate on those data structures, and visualization algorithms to produce movies and still images of the results.
ABSTRACT We present a multiwavelength study of the flat-spectrum radio quasar CTA 102 during 2013–2017. We use radio-to-optical data obtained by the Whole Earth Blazar Telescope, 15 GHz data from the Owens Valley Radio Observatory, 91 and 103 GHz data from the Atacama Large Millimeter Array, near-infrared data from the Rapid Eye Monitor telescope, as well as data from the Swift (optical-UV and X-rays) and Fermi (γ-rays) satellites to study flux and spectral variability and the correlation between flux changes at different wavelengths. Unprecedented γ-ray flaring activity was observed during 2016 November–2017 February, with four major outbursts. A peak flux of (2158 ± 63) × 10−8 ph cm−2 s−1, corresponding to a luminosity of (2.2 ± 0.1) × 1050 erg s−1, was reached on 2016 December 28. These four γ-ray outbursts have corresponding events in the near-infrared, optical, and UV bands, with the peaks observed at the same time. A general agreement between X-ray and γ-ray activity is found. The γ-ray flux variations show a general, strong correlation with the optical ones with no time lag between the two bands and a comparable variability amplitude. This γ-ray/optical relationship is in agreement with the geometrical model that has successfully explained the low-energy flux and spectral behaviour, suggesting that the long-term flux variations are mainly due to changes in the Doppler factor produced by variations of the viewing angle of the emitting regions. The difference in behaviour between radio and higher energy emission would be ascribed to different viewing angles of the jet regions producing their emission.
Abstract not provided.
This software package processes Atmospheric Infrared Sounder (AIRS) Level 2 swath standard product geophysical parameters, and generates global, colorized, annotated maps. It automatically generates daily and multi-day averaged colorized and annotated maps of various AIRS Level 2 swath geophysical parameters. It also generates AIRS input data sets for Eyes on Earth, Puffer-sphere, and Magic Planet. This program is tailored to AIRS Level 2 data products. It re-projects data into 1/4-degree grids that can be combined and averaged for any number of days. The software scales and colorizes global grids utilizing AIRS-specific color tables, and annotates images with title and color bar. This software can be tailored for use with other swath data products for the purposes of visualization.
Automatic acquisition and tracking of pupil-iris boundary and of corneal reflection of light source in oculometer using electro-optic method for eye direction measurement
Assumptions regarding eye morphology are implicit in iris recognition algorithms. The cornea is assumed to have little to no effect on the view of the iris texture when the eye gaze is non-frontal, the iris is assumed flat, and the eye is assumed to be imaged via an orthographic projection. If these assumptions hold, affine transformations may be used to rectify non-frontally posed images to a frontal view and the rubber sheet model may be accurately used to normalize the iris annulus to a rectangular image. This work examines how iris recognition performance degrades when the first two assumptions are violated. Using a computer renderable eye model, a data set is created varying the presence of the cornea and a parameterized non-planarity of the iris shape across a large range of eye gaze angles. Matching scores are created using a commercial matcher. Thus, when comparing the relative impact of each assumption violation, it is observed that iris non-planarity presents a more significant problem than corneal refractive distortion with regard to iris recognition accuracy in non-frontal images.
Purpose: To evaluate the variations in dwell times and doses expected when using an episcleral brachytherapy device for treatment of neovascular agerelated macular degeneration (n-AMD) based on accurate imaging modalities Methods: Data from 40 eyes from 40 subjects with known n- AMD acquired through the Distance of Choroid Study (DOCS) conducted at Moorfields Eye Hospital was used to determine the target depth; the distance from the outer scleral surface of the eye, through the choroid, to the apex of the choroidal neovascularization (CNV). Each subject underwent, in triplicate, enhanced-depth Spectral Domain Optical Coherence Tomography (SD-OCT), Swept Source Optical Coherence Tomography, (SS-OCT) and Ocular Ultrasound (O-US). These data are the most comprehensive and accurate measurements of the dimensions of the CNV and adjacent layers of the eye for this cohort of patients. During treatment of n-AMD, patients receive a dose of 24Gy to the apex at the target depth. Using the percentage depth dose for a Sr-90 episcleral brachytherapy device, dwell times and doses to the apex were computed to determine the expected variations. Results: The mean target depth and the 95% confidence interval (CI) determined by combining O-US with SD-OCT were 1326 (956,1696)µm and with SS-OCT were 1332 (970,1693)µm. The calculated corresponding mean dwell times and 95% (CI) were 334 (223,445)s and 335 (226,445)s for SD-OCT and SS-OCT determined depths, respectively. The corresponding mean apex dose and 95% (CI) were 24 (35.9,18.0)Gy (SD-OCT) and 24 (35.6,18.1)Gy (SS-OCT). Conclusion: For episcleral brachytherapy treatment of n-AMD, using a patient population average target depth for treatment planning is inadequate, resulting in dose variations of a factor of approximately two over the 95% CI and larger variations for a nontrivial segment of the population. Each patient should have individualized imaging studies to determine the target depth for use in the dwell time calculation. Study was sponsored by Salutaris Medical Devices, Ltd., a subsidiary of Salutaris Medical Devices, Inc. Hamilton and Marsteller are founders of Salutaris Medical Devices, Inc. Drew, McGovern and Vitali are minor equity holders in Salutaris Medical Devices, Inc.
Methods and systems of the present invention identify the presence of and/or the concentration of a selected analyte in a subject by: (a) illuminating a selected region of the eye of a subject with an optical excitation beam, wherein the excitation beam wavelength is selected to generate a resonant Raman spectrum of the selected analyte with a signal strength that is at least 100 times greater than Raman spectrums generated by non-resonant wavelengths and/or relative to signals of normal constituents present in the selected region of the eye; (b) detecting a resonant Raman spectrum corresponding to the selected illuminated region of the eye; and (c) identifying the presence, absence and/or the concentration of the selected analyte in the subject based on said detecting step. The apparatus may also be configured to be able to obtain biometric data of the eye to identify (confirm the identity of) the subject.
Purpose/Objective(s): Radiation therapy can be used to treat uveal metastases with the goal of local control and improvement of quality of life. Proton therapy can be used to treat uveal tumors efficiently and with expectant minimization of normal tissue injury. Here, we report the use of proton beam therapy for the management of uveal metastases. Methods and Materials: A retrospective chart review was made of all patients with uveal metastases treated at our institution with proton therapy between June 2002 and June 2012. Patient and tumor characteristics, fractionation and dose schemes, local control, and toxicities are reported. Results: Ninety patients were identified. Of those, 13 were excluded because of missing information. We report on 77 patients with 99 affected eyes with available data. Patients were 68% female, and the most common primary tumor was breast carcinoma (49%). The median age at diagnosis of uveal metastasis was 57.9 years. Serous retinal detachment was seen in 38% of treated eyes. The median follow-up time was 7.7 months. The median dose delivered to either eye was 20 Gy(relative biological effectiveness [RBE]) in 2 fractions. Local control was 94%. The median survival after diagnosis of uveal metastases was 12.3 months (95% confidence interval, 7.7-16.8). Death in all cases was secondary to systemic disease. Radiation vasculopathy, measured decreased visual acuity, or both was observed in 50% of evaluable treated eyes. The actuarial rate of radiation vasculopathy, measured decreased visual acuity, or both was 46% at 6 months and 73% at 1 year. The 6 eyes with documented local failure were successfully salvaged with retreatment. Conclusions: Proton therapy is an effective and efficient means of treating uveal metastases. Acutely, the majority of patients experience minor adverse effects. For longer-term survivors, the risk of retinal injury with vision loss increases significantly over the first year.
Data processing procedures used on flights of Rangers VII, VIII and IX, evaluating lunar photographs
No abstract available
Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.
Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.
Iris recognition can be accomplished for a wide variety of eye images by using plenoptic imaging. Using plenoptic technology, it is possible to correct focus after image acquisition. One example technology reconstructs images having different focus depths and stitches them together, resulting in a fully focused image, even in an off-angle gaze scenario. Another example technology determines three-dimensional data for an eye and incorporates it into an eye model used for iris recognition processing. Another example technology detects contact lenses. Application of the technologies can result in improved iris recognition under a wide variety of scenarios.
INTRODUCTION Posture and locomotion are among the functions most affected by space flight. Postflight ataxia can be quantified easily by using the walk on the floor line test with the eyes closed (WOFEC). Data from a modified WOFEC were obtained as part of an ongoing interdisciplinary pre- and postflight study (Functional Task Test, FTT) designed to evaluate both postflight functional performance of astronauts and related physiological changes. METHODS Five astronauts with flight durations of 12 to 16 days participated in this study. Performance measurements were obtained in 2 preflight sessions, on landing day, and 1, 6, and 30 days after landing. The WOFEC test consisted of walking with the feet placed heel to toe in tandem, arms folded across the chest and eyes closed, for 10 steps. A trial was initiated after the eyes were closed and the front foot was aligned with the rear foot. The performance metric was the average percentage of correct steps completed over 3 trials. A step was not counted as correct if the crewmember sidestepped, opened eyes, or paused for more than 3 seconds between steps. Step accuracy was scored independently by 3 examiners. RESULTS Immediately after landing subjects seemed to be unaware of their foot position relative to their body or the floor. The percentage of correct steps was significantly decreased on landing day. Partial recovery was observed the next day, and full recovery to baseline on the sixth day post landing. CONCLUSION These data clearly demonstrate the sensorimotor challenges facing crewmembers after they return from space flight. Although this simple test is intended to complement the FTT battery of tests, it has some stand-alone value as it provides investigators with a means to quantify vestibular ataxia as well as provide instant feedback on postural stability without the use of complex test equipment.
Twenty-five years ago the desktop computer started becoming ubiquitous in the scientific lab. Researchers were delighted with its ability to both control instrumentation and acquire data on a single system, but they were not completely satisfied. There were often gaps in knowledge that they thought might be gained if they just had more data and they could get the data faster. Computer technology has evolved in keeping with Moore’s Law meeting those desires; however those improvements have of late become both a boon and bane for researchers. Computers are now capable of producing high speed data streams containing terabytes of information; capabilities that evolved faster than envisioned last century. Software to handle large scientific data sets has not kept up. How much information might be lost through accidental mismanagement or how many discoveries are missed through data overload are now vital questions. An important new task in most scientific disciplines involves developing methods to address those issues and to create the software that can handle large data sets with an eye towards scalability. This software must create archived, indexed, and searchable data from heterogeneous instrumentation for the implementation of a strong data-driven materials development strategy. At the National Center for Photovoltaics in the National Renewable Energy Laboratory, we began development a few years ago on a Laboratory Information Management System (LIMS) designed to handle lab-wide scientific data acquisition, management, processing and mining needs for physics and materials science data, and with a specific focus towards future scalability for new equipment or research focuses. We will present the decisions, processes, and problems we went through while building our LIMS system for materials research, its current operational state and our steps for future development.