Search NASASearch

SEARCH · Search NASA

Results for “Demand flexibility”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Consumer Benefits of Clean Energy: Renewable Energy

Meeting national and state decarbonization goals requires a transition to clean energy technologies. Energy efficiency, demand flexibility, renewable energy and storage can reduce consumers’ electricity bills, lower total electricity system costs, and provide health and resilience benefits. Berkeley Lab developed a series of briefs that explore these consumer benefits of a clean energy transition. This brief discusses some of the possible consumer benefits of utility-scale and behind the meter renewable energy, with a focus on how these resources can contribute to a low-cost electricity system. It begins with a literature review of modeled impacts, primarily considering consumer benefits, of the Inflation Reduction Act and Bipartisan Infrastructure Law. Next, it discusses how utility-scale renewable energy can contribute to a low-cost electricity system (e.g., in some cases, low resource costs relative to other alternatives). It concludes with a discussion of behind-the-meter renewable energy consumer benefits (e.g., reduced host electricity bill, increased property value, resilience).

29 ENERGY PLANNING, POLICY, AND ECONOMY

National Energy Education Development Project (NEED Project) (CRADA Final Report)

The U.S. Department of Energy Building Technologies Office (BTO) funds student competitions that introduce students to careers in the building sciences and increase public awareness around high-performance buildings to support the goal of developing, demonstrating, and accelerating the adoption of cost-effective technologies, techniques, tools, and services that enable high-performing, energy-efficient and demand-flexible residential and commercial buildings in both the new and existing buildings markets. The U.S. Department of Energy Solar Decathlon® (DOE/SD) is a flagship, high-visibility international competition started in 2002 that advances the goals of BTO by introducing students to building science careers; educating students and the public about the latest technologies and materials in high-performance buildings; encouraging student-led projects and research centered around building science; and demonstrating to the public the comfort and savings of homes that combine energy-efficient construction, home systems, appliances and innovative design with onsite renewable energy production. SD is a collegiate competition, comprising 10 contests, that challenges student teams to design and build highly efficient and innovative buildings powered by renewable energy. The winners will be those teams that best blend architectural and engineering excellence with innovation, market potential, building efficiency, and smart energy production. Solar Decathlon is comprised of two Challenges – Design Challenge (annual) and Build Challenge (biennial). The National Renewable Energy Laboratory (NREL) provides competition management for Solar Decathlon. NREL and Participant establish this CRADA to enable the success of the overall Solar Decathlon program by managing sponsorship funds and creating a K12 education program. Participant is to act as an Education Partner to Solar Decathlon, which includes: 1) accepting and dispersing sponsorship funds for DOE/SD; and 2) providing K12 education program to support Solar Decathlon Competition Events in April each year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Grid Interactive Micro-Distributed Display Case

The goal of this project is to design, fabricate and validate the performance of an economically viable next-generation self-contained, refrigerated open vertical display case with integrated thermal storage that improves energy efficiency, enhances demand flexibility, uses an environmentally friendly refrigerant, improves human comfort

25 ENERGY STORAGE

Quantifying and Optimizing the Energy Benefits of Mass Timber Construction

The International Mass Timber Alliance (IMTA) is a global organization of industry leaders, engineers, scientists, and associations dedicated to advancing mass timber construction. Its mission is to generate and disseminate scientific data supporting the development of standardized construction and energy efficient practices that promote the adoption of mass timber worldwide. IMTA collaborated with Oak Ridge National Laboratory (ORNL) to leverage ORNL’s expertise in building envelope modeling and testing to evaluate how mass timber construction can reduce peak heating and cooling demand, lower overall energy use, and improve resilience during power outages. A previous study of 80 mass timber buildings in Finland found measured energy use up to 50% lower than predicted by simulation. This project aimed to validate and extend those findings for U.S. buildings through analytical modeling, laboratory testing, and full-scale building evaluations. The research focused on the thermal performance of low-embodied-energy wall assemblies, such as cross-laminated timber (CLT) panels and log walls, with particular attention to the effects of thermal inertia on indoor comfort and energy performance. While mass timber’s structural and fire-resistance properties are well documented, its whole-building thermal behavior has received limited attention. Field data, simulation results, and resilience testing from this study will inform future modeling practices, design guidelines, and construction practices by quantifying the unique thermal and demand-flexibility benefits of mass timber construction.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ComStock Measure Documentation: High-Efficiency Rooftop Unit

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - high-efficiency rooftop unit (RTU) - and briefly introduces key results. The full public data set can be accessed on the Comstock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ComStock Measure Documentation: Variable-Speed Pumps

Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models, this work produces national data sets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The "baseline" model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass adoption impact on the baseline building stock. "Measures" refers to various "what-if" scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public data sets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario - variable speed pumps - and briefly introduces key results. The full public data set can be accessed on the ComStock data lake or via the Data Viewer at comstock.nlr.gov. The public data set enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ComStock Measure Documentation: Fan Static Pressure Reset for Multizone Variable Air Volume Systems

This report assesses the potential for nationwide adoption of a duct static pressure reset in MZ VAV systems in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario—Fan Static Pressure Reset for Multizone Variable Air Volume (VAV) Systems—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use case (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

ComStock Measure Documentation: Thermostat Setbacks During Unoccupied Periods

This report assesses the potential for nationwide adoption of thermostat setbacks in appropriate applications. Building on the 3-year End-Use Load Profiles project to calibrate and validate the U.S. Department of Energy’s ResStock™ and ComStock™ models, this work produces national datasets that enable cities, states, utilities, and other stakeholders to answer a broad range of questions regarding their commercial building stock. ComStock is a highly granular, bottom-up model that uses various data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. The “baseline” model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology of the baseline model is discussed in the ComStock Reference Documentation. The goal of this work is to develop energy efficiency and demand flexibility measures that cover market-ready technologies and study their mass-adoption impact on the baseline building stock. “Measures” refers to various “what-if” scenarios that can be applied to buildings. The results for the baseline and measure scenario simulations are published in public datasets that provide insights into building stock characteristics, operational behaviors, utility bill impacts, and annual and sub-hourly energy usage by fuel type and end use. This report describes the modeling methodology for a single ComStock measure scenario— Thermostat Setbacks During Unoccupied Periods—and briefly introduces key results. The full public dataset can be accessed on the ComStock data lake or via the Data Viewer at comstock.nrel.gov. The public dataset enables users to create custom aggregations of results for their use cases (e.g., filter to a specific county or building type).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Community-Engaged Energy Transition Planning in Holyoke

The overarching motivation of this project is to provide stakeholder-engaged research and education to enable a clean, equitable, and resilient energy transition. Presently, low-income communities and people of color are disproportionately burdened by environmental harm, while also being routinely left out of planning processes and benefits from infrastructure improvements. The Energy Transition Institute (ETI) addresses these issues in three ways: community engagement, educating diverse future leaders, and cutting-edge research. As municipalities across the Commonwealth plan their transition to a climate-friendly energy system, research from ETI will advance technical and social understanding of heating electrification, energy storage, demand flexibility, reliability and resiliency of power distribution infrastructure, with attention to equity. This will benefit surrounding communities, cities and towns across Massachusetts, and the global research community

14 SOLAR ENERGY

High-Fidelity Building Emulator for Integrated Comfort and Energy Analysis using EnergyPlus and Radiance

The growing need for smart, energy-efficient, and occupant-centric buildings has created a demand for advanced control systems that can optimize building operations to balance energy savings, demand flexibility, and comfort. However, current building energy simulation tools, such as EnergyPlus, have limitations that hinder the development and evaluation of these complex control systems. To address this challenge, we introduce a high-fidelity building emulator that dynamically couples EnergyPlus with Radiance for enhanced daylight modeling. The introduced workflow allows researchers and practitioners to rapidly develop and evaluate innovative control solutions. An example study looking at a south-facing office zone revealed up to 67% deviation in predicted light levels, which can significantly impact building assessment.

Yu, Tammie

Information Switching Processor (ISP) contention analysis and control

Future satellite communications, as a viable means of communications and an alternative to terrestrial networks, demand flexibility and low end-user cost. On-board switching/processing satellites potentially provide these features, allowing flexible interconnection among multiple spot beams, direct to the user communications services using very small aperture terminals (VSAT's), independent uplink and downlink access/transmission system designs optimized to user's traffic requirements, efficient TDM downlink transmission, and better link performance. A flexible switching system on the satellite in conjunction with low-cost user terminals will likely benefit future satellite network users.

Shyy, D.

Design and Development of a Baseband Processor for the Advanced Communications Technology Satellite

This paper describes the implementation of the operational baseband processor (BBP) subsystem on board the NASA Advanced Communications Technology Satellite (ACTS). The BBP supports the network consisting of the NASA ground station (NGS) low burst rate (LBR) terminals, and the T1 very small aperture terminals (VSAT's), to provide flexible, demand assigned satellite switched (SS), baseband processed frequency division modulated (FDM)/time division multiple access (TDMA) operations. This paper presents an overview of the baseband processor and includes a description of the data flow, functional block diagrams, and a discussion of the implementation of BBP. A discussion of the supporting technologies for the BBP is presented. A brief summary of BBP-level performance testing is also presented. Finally, a discussion of the implications of current technology on the BBP design, if it were to be developed today, is presented.

Lee, Kerry D.

The Best of Both Worlds: Combined Thermal and Battery Storage for Widespread Building Decarbonization

To meet 2050 decarbonization targets, widespread building electrification is a critical complement to clean power generation. Behind-the-meter storage (BTMS) (e.g., battery electric energy storage [EES] and thermal energy storage [TES]) integrated with buildings or building end uses to store and supply energy at optimal times can minimize burdens associated with operation, planning, and upgrades to the electrical grid sometimes triggered by building electrification. Such BTMS systems can serve the dual purpose of providing enhanced resilience at the building and grid level, and support the deployment of renewable generation needed for wide-scale decarbonization. While TES can cost-effectively shed and shift thermal loads, it cannot generally backup or shift non-thermal building end uses. EES, by contrast, is more expensive, but applicable to all end uses (i.e., thermal and electrical loads). Combined together, these storage systems can be traded off against one another to perform optimally in meeting demand flexibility, decarbonization goals, and energy resilience of the buildings at a lower total system cost. This paper proposes a framework to define BTMS benefits, provides four illustrative electrification scenarios using TES and EES, and discusses the combined TES/EES benefits with building energy modeling results. The paper also highlights potential barriers to adoption of BTMS and a path forward.

buildings

OpenStudio Development, Maintenance, and Support

BEM is a key decision support tool for energy efficiency, demand flexibility, and electrification at the building and building stock levels. The OpenStudio SDK maximizes the value of BEM by enhancing the productivity, consistency, and transparency with which it is applied. OpenStudio enables BEM experts to encapsulate domain and process knowledge in such a way that makes it usable by a range of stakeholders.

BEM

Network-Aware and Welfare-Maximizing Dynamic Pricing for Energy Sharing: Preprint

The proliferation of behind-the-meter (BTM) distributed energy resources (DER) within the electrical distribution network presents significant supply and demand flexibilities, but also introduces operational challenges such as voltage spikes and reverse power flows. In response, this paper proposes a network-aware dynamic pricing framework tailored for energy-sharing coalitions that aggregate small, but ubiquitous, BTM DER downstream of a distribution system operator's (DSO) revenue meter that adopts a generic net energy metering (NEM) tariff. By formulating a Stackelberg game between the energy-sharing market leader and its prosumers, we show that the dynamic pricing policy induces the prosumers toward a network-safe operation and decentrally maximizes the energysharing social welfare. The dynamic pricing mechanism involves a combination of a locational ex-ante dynamic price and an ex-post allocation, both of which are functions of the energy sharing's BTM DER. The ex-post allocation is proportionate to the price differential between the DSO NEM price and the energy sharing locational price. Simulation results using real DER data and the IEEE 13-bus test systems illustrate the dynamic nature of network-aware pricing at each bus, and its impact on voltage.

energy communities

Energy performance of an operational government building retrofitted with ceiling phase change material tiles in a mixed-humid climate

The aging U.S. building stock requires various retrofit measures to enhance their energy efficiency. Here, this study explores the integration of thermal energy storage and advanced building controls as viable retrofit solutions for load flexibility and peak demand response while maintaining the occupants' comfort. A detailed assessment is conducted on the energy use of an administrative building in Sumner County, Kansas, focusing on the implementation of phase change materials (PCMs) in the ceiling of occupied zones. First, a time-resolved, whole-building energy model is developed in EnergyPlus, incorporating complex thermal behaviors such as air exchange between the plenum space and occupied zones, envelope leakage, and operational schedules. The model is then validated using experimental field test data, and subsequently a parametric assessment of key PCM properties and application strategies is performed to evaluate cooling electricity demand benefits. The parametric study shows that the optimal retrofit strategy, comprising a PCM with 23°C peak melting temperature, 0.125 in. (3.17 mm) thickness, and 150 kJ/kg latent heat, combined with active controls that include 8 h of precooling, forced convection under the ceiling, and a 2°C thermostat setback during peak hours, can result in a maximum load shift during the peak period of 99.6 % and the total electricity savings during the peak period of 98.9 % for the optimum case and thus provide significant cost savings under time-of-use pricing scenarios.

24 POWER TRANSMISSION AND DISTRIBUTION

ResStock Measure Documentation: HVAC Load Flexibility

This report is part of a series describing different ResStock(TM) measures. "Measures" refers to energy efficiency retrofits that can be applied to buildings during modeling. This documentation covers the "HVAC Load Flexibility" measure upgrade methodology and briefly discusses key results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Intelligent industrial demand response to increase grid flexibility and reliability: A review

The rapid transition toward renewable energy has introduced challenges in grid stability due to the intermittency of non-dispatchable sources like solar and wind. Industrial Demand Response (IDR) offers a promising, cost-effective solution that adjusts energy consumption patterns to align with supply, increases renewable utilization, and reduces costs. This review provides an updated analysis of IDR, sorting technologies into five categories: energy storage, scheduled energy usage, operational flexibility, on-site generation, and intelligent operations. Energy storage solutions, while requiring little flexibility, often have the longest payback periods. While slightly better, on-site generation also has longer payback periods, ranging from 5 to 20 years or more. Scheduled energy usage, operational flexibility, and intelligent operations allow significant peak reduction at lower capital costs but require greater flexibility. While 15–20 % peak reduction is within the range of all five categories, scheduled energy use and on-site energy generation are shown to have reductions of up to 70–80 % in select scenarios. Combining multiple IDR strategies from these five categories maximizes both financial and operational benefits. Synergistic approaches are shown to enhance grid stability while reducing costs. As the grid evolves, IDR will enable a more flexible, renewable-powered future that will benefit industrial facilities and the broader energy system.

Demand flexibility