Search NASA⌕ Search

SEARCH · Search NASA

Results for “Demand management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Modeling and Detection of Future Cyber-Enabled DSM Data Attacks

Demand-Side Management (DSM) is an essential tool to ensure power system reliability and stability. In future smart grids, certain portions of a customer’s load usage could be under the automatic control of a cyber-enabled DSM program, which selectively schedules loads as a function of electricity prices to improve power balance and grid stability. In this scenario, the security of DSM cyberinfrastructure will be critical as advanced metering infrastructure and communication systems are susceptible to cyber-attacks. Such attacks, in the form of false data injections, can manipulate customer load profiles and cause metering chaos and energy losses in the grid. The feedback mechanism between load management on the consumer side and dynamic price schemes employed by independent system operators can further exacerbate attacks. To study how this feedback mechanism may worsen attacks in future cyber-enabled DSM programs, we propose a novel mathematical framework for (i) modeling the nonlinear relationship between load management and real-time pricing, (ii) simulating residential load data and prices, (iii) creating cyber-attacks, and (iv) detecting said attacks. In this framework, we first develop time-series forecasts to model load demand and use them as inputs to an elasticity model for the price-demand relationship in the DSM loop. This work then investigates the behavior of such a feedback loop under intentional cyber-attacks. We simulate and examine load-price data under different DSM-participation levels with three types of random additive attacks: ramp, sudden, and point attacks. We conduct two investigations for the detection of DSM attacks. The first studies a supervised learning approach, with various classification models, and the second studies the performance of parametric and nonparametric change point detectors. Results conclude that higher amounts of DSM participation can exacerbate ramp and sudden attacks leading to better detection of such attacks, especially with supervised learning classifiers. We also find that nonparametric detection outperforms parametric for smaller user pools, and random point attacks are the hardest to detect with any method.

97 MATHEMATICS AND COMPUTING↗

Of impacts, agents, and functions: An interdisciplinary meta-review of smart home energy management systems research

Smart home energy management technologies (SHEMS) have long been viewed as a promising opportunity to manage the way households use energy. Research on this topic has emerged across a variety of disciplines, focusing on different pieces of the SHEMS puzzle without offering a holistic vision of how these technologies and their users will influence home energy use moving forward. This paper presents the results of a systematic, interdisciplinary meta-review of SHEMS literature, assessing the extent to which it discusses the role of various SHEMS components in driving energy benefits. Results reveal a bias towards technical perspectives and controls approaches that seek to drive energy impacts such as load management and energy savings through SHEMS without user or third-party participation. Not only are techno-centric approaches more common, there is also a lack of integration of these approaches with user-centric, information-based solutions for driving energy impacts. Finally, these results suggest future work should investigate more holistic solutions for optimal impacts on household energy use. We hope these results will provoke a broader discussion about how to advance research on SHEMS to capitalize on their potential contributions to demand-side management initiatives moving forward.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Quantifying the effect of multiple load flexibility strategies on commercial building electricity demand and services via surrogate modeling

The expansion of commercial building demand response as a demand-side management resource for the electric grid necessitates new decision support resources for customers seeking to assess the benefit–risk tradeoffs of possible strategies for energy flexible building operations. To address this need, we, in this study, develop surrogate models that predict the impacts of several load flexibility strategies on commercial building electricity demand and indoor temperature, focusing on offices and retail buildings at multiple scales. The surrogate models are fit to a synthetic database generated via whole building simulations, which establish the relationships between the key operational features of a given strategy and potential changes in building demand and temperature across a variety of contexts. The surrogate models are translated to a Bayesian framework to allow straightforward communication of uncertainty and parameter updating given new evidence. We find strong predictive performance across the suite of models, underscoring the usefulness of the approach in guiding decisions about implementing load flexibility strategies under a particular set of operational and environmental conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Demand Bidding Model for Multi-Product Industrial Plants

The growing contribution of renewable energy sources has increased volatility and uncertainty in electricity markets, challenging traditional grid operation paradigms. Demand bidding (DB), a market participation model where (large) electricity users communicate their willingness to pay for electricity to the grid operator, was shown in previous work to enhance grid stability and lower generation cost. We present a DB model for multi-product industrial plants, based on an extended optimal power flow problem where the plant dynamics are represented using autoregressive with extra inputs (ARX) models. We compare DB to price-based demand-side management, showing that, under certain assumptions, the two approaches are equivalent, while DB provides more transparency and predictability to the grid operator. A case study based on an industrial air separation unit is discussed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Spatio-temporal impacts of a utility’s efficiency portfolio on the distribution grid

Energy Efficiency has historically focused on delivering savings to offset growth in energy supply. Today’s growing emphasis on decarbonization of the energy supply is driving renewables adoption and increased interest in electrification. As a result, energy efficiency is being assessed not just in its ability to offset load growth, but also for its ability to alleviate location-specific constraints on transmission and distribution infrastructure. This work demonstrates that advanced measurement and verification modeling techniques can be used to estimate the spatio-temporal grid impact of a portfolio of energy efficiency programs. It extends measurement-based methods to an entire Demand Side Management portfolio and uses a single model to predict annual as well as seasonal building energy use with near-zero bias. In addition, new metrics are introduced to assess grid level impacts of energy efficiency. The results show that the efficiency program portfolio delivers savings of over 12% at the territory-wide proxy level, with substation and feeder level savings ranging from 0.4% to 26%, and ~5%-42% respectively. Overall, these savings impacted 1.0%–1.4% of the energy used at these locations in the grid. This work provides a methodology with potential to connect efficiency with distribution planning, carrying implications for non-wires alternatives and targeted delivery of efficiency programs.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Identification and Online Updating of Dynamic Models for Demand Response of an Industrial Air Separation Unit

Demand-response operation of air separation units requires frequent changes in production rate(s), and scheduling calculations must explicitly consider process dynamics to ensure feasibility of the solutions. To this end, scale-bridging models (SBMs) approximate the scheduling-relevant dynamics of a process and its controller in a low-order representation. In contrast to previous works that have employed nonlinear SBMs, this paper proposes linear SBMs, developed using time-series analysis, to facilitate online scheduling computations. Using a year-long industrial dataset, we nd that compact linear SBMs are suitable approximations over typical scheduling horizons, but that their accuracies are unpredictable over time. We introduce a strategy for online updating of the SBMs, based on Kalman ltering schemes for online parameter estimation. The approach greatly improves the accuracy of SBM predictions and will enable the use of linear SBM-based demand-response scheduling in the future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Assessing thermal comfort and participation in residential demand flexibility programs

Residential space-conditioning-based demand flexibility (DF) has become an increasingly sought-after method for demand-side load management to enhance grid reliability and facilitate integration of renewable energy generation. However, predicting the effectiveness and flexibility of residential DF resources is challenging due to the variability in household energy use behaviors. Current estimates show that only 50 % of projected savings from DF resources are actualized due to regulatory, technological, and social barriers. From a household perspective, concerns over thermal comfort during space conditioning-based DF events significantly impact participation decisions. Currently, there is a very limited understanding of how thermal comfort during space-conditioning-based DF events in real-world settings impacts household energy use behaviors and, consequently, the success of DF programs in achieving targeted savings. This paper proposes a method to comprehensively assess the thermal comfort implications of DF strategies and presents results of their impacts on DF event participation decisions and demand savings. Here, the proposed method was applied to a heat pump DF field study in Cordova, Alaska. The study’s key findings are: 1) DF event setpoint offsets that maintain indoor operative temperatures between 18 to 22 °C (65 to 71°F) may be preferred in Cordova, Alaska; 2) Household-level thermal comfort is more sensitive to the duration of the DF event than to the degree of temperature offset from baseline conditions; 3) The delayed impact of changes in indoor operative temperature in response to setpoint offsets, both during and after a DF event, influences occupants’ thermal comfort perceptions and willingness to persistently participate in events. The findings from application of the proposed method can help inform future larger-scale occupant-centric DF programs as it can capture information not readily available through utility and device-level energy use data. Thus, it can supplement these sources and help program administrators develop occupant-centric DF strategies, enabling more accurate predictions of participation rates and savings estimates for space-conditioning-based DF programs.

Demand side management↗

DFAT: A web-based toolkit for estimating demand flexibility in building-to-grid integration

Demand Flexibility Assessment Tool (DFAT) is an open source web-based tool that estimates the demand flexibility potential of common control strategies in commercial buildings. The toolkit features a demand flexibility estimation tool that contains two calculators, basic and advanced, based on the level of input of customer data. The basic version calculates demand shed metrics for the control strategy “global temperature adjustment” and “cycle on/off compressors” using customer building information, local weather data, and electrical meter data. The advanced version, which uses detailed HVAC equipment data, calculates demand flexibility metrics for control strategies such as static pressure reset, global temperature adjustment, and cycle on/off compressors. In addition to the demand flexibility estimation tool, this toolkit offers a benchmarking tool that helps facility operators, aggregators, and utility resource managers assess demand flexibility opportunities, quantify/verify performance, and compare their performance against that of their peers.

Leong, Michael↗

Modulating thermal load through lightweight residential building walls using thermal energy storage and controlled precooling strategy

Precooling is a recognized technique for reducing cooling energy in buildings during peak hours by shifting load to off-peak hours. This technique is particularly effective in buildings with high thermal mass, because of their large thermal energy storage capacity, and in commercial buildings due to their variable electricity pricing based on time-of-use rates. Precooling in residential buildings has been a matter of limited interest in the past because of their low thermal mass and typically uniform electricity pricing rate. While previous studies on precooling primarily focused on cost savings, an important aspect of precooling is the thermal load modulation, which could be very effective in managing peak demand in lightweight residential buildings integrated with thermal energy storage systems. In this study, we examine different precooling strategies to manage the heat gains in lightweight building walls integrated with phase-change materials. We create nine different precooling profiles by controlling the interior temperature, and then evaluate the influence of the precooling profiles on four key building energy performance parameters: total heat gain, peak heat gain, maximum heat gain during peak hours, and time at which peak occurs. To thoroughly understand the fundamental physics, we first consider hypothetical climates and obtain the optimal precooling strategy required to achieve maximum peak shedding and shifting while minimizing the total heat gains. We then extend the model to Baltimore, Maryland, and estimate the benefits of the optimized precooling strategy under real conditions. The optimal precooling strategy proposed in this study can shift the peak heat gain by up to 14 hours, thereby reducing the heat gain during peak period by up to 95%, at the expense of a 23% increase in the total heat gains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermally anisotropic building envelope for thermal management: finite element model calibration using field evaluation data

The thermally anisotropic building envelope (TABE) is an active building envelope that redistributes thermal loads in response to weather conditions and building energy demand. Conductive layers throughout the TABE distribute low-grade heat among hydronic loops, altering heat flow direction and intensity. Finite element models of TABE roof and wall panels were developed and calibrated using field evaluation data. The calibration results showed that heat flux differences between the experimental data and finite element models averaged –0.42% and 3.57%, with a maximum mean square error of 1.78 and 3.96 for roof and wall panels, respectively. A reduction in heat flux from the environment to the building living space over the entire testing period (weeks in July/August) was found to be 85% for roof panels and 335% (load reversed) for wall panels. Finally, these results indicate TABE can effectively harness low-grade thermal energy sources to achieve high energy efficiency and promote demand-side management.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

When Do Efficiency and Demand Flexibility Go Hand-in-hand?

Utilities have been experimenting with integrated demand side management (IDSM) programs since the 2000s. The potential benefits of improved program cost-effectiveness and customer engagement from combining energy efficiency (EE), demand flexibility (DF), and other distributed energy resources into an integrated customer offering have been recognized although there are several known regulatory and program administrative challenges. In addition, as buildings adopt EE measures, the baseline load profile change generally reduces the potential load that can be shed or shifted. This has been a significant technical barrier for customers and program implementers. However, it is a myth that EE always reduces DF. Load change from EE can be time-varying. Therefore, whether EE improves or reduces DF should be evaluated on an individual measure basis accounting for weather dependencies and interactions. For IDSM program design purpose, it is useful to understand how common EE features influence DF and the underlying building physics. In this paper, we use parametric simulations of a prototype medium office building to evaluate how various EE features influence DF, measured by a “demand decrease intensity” (W/ft2) metric. These EE features cover envelope characteristics, internal loads, and airside HVAC system. The parametric analysis shows that some efficient HVAC control measures will increase DF but not the traditional building envelope, lighting, and ventilation-related efficiency measures. These findings contribute to the technical basis for achieving enhanced energy benefits by packaging appropriate HVAC control measures in IDSM program design. Program developers should further validate these results in targeted pilot projects.

Yu, Lili↗

Meter-Based Assessment of the Time and Locational Benefits of a Large Utility’s DSM Portfolio

As decarbonization goals drive increasing levels of renewable generation, there is a need to understand the time- and location-based savings benefits of demand-side management (DSM) programs. The challenges of the 'duck curve' are driving the utility industry to consider how programs can be optimized to match demand profiles with low carbon generation resources. From an infrastructure standpoint, time- and location-targeted DSM could serve as a ‘non-wires alternative’ (NWA) to defer equipment upgrades. Additional DSM value streams are motivating innovation in savings evaluation, providing more resolved insights beyond the total annual program impact. Methods grounded in the principles of billing analysis, leveraging hourly metering at the distribution grid, can provide new visibility into the spatial and temporal savings achieved through DSM. A large body of work has investigated related topics including interval meter-based savings analysis, the time- varying nature of efficiency measures, and NWA. A less studied topic concerns the impact of DSM on the grid, based on metered consumption. This paper presents an analysis of interval data across more than 25,000 customers and twelve substations, from the Sacramento Municipal Utility District. The results show for different locations on the grid: achieved savings and the impact on grid consumption; hourly savings shapes for DSM program participants and non-participants, and how those shapes vary with season; and the impact of the programs on peak demand. These findings show the current impact of DSM, with implications for future, more intentional targeting as the utility continues to pursue aggressive electrification, efficiency, load flexibility, and reliable NWA.

Granderson, Jessica↗

Master Services Agreement - Flexible Feeder/Distribution System Support: Cooperative Research and Development (Final Report)

PGE will engage NREL on a broad range of projects related to the integration of distributed energy resources (DERs) into the utility's operations. This portfolio of work could include projects focused on DER adoption models, advanced distribution management system (ADMS) and distributed energy management system (DERMS) design, DER dispatch strategy development, and DER valuation framework development. Additional topics could include long-term energy planning, renewable energy, energy efficiency and demand-side management. As well as technology evaluations and design guidance for building retrofits and new construction projects, energy and energy infrastructure planning, policies, and markets (and their analysis), energy storage, energy security and resilience (including energy system-related cybersecurity), transportation and mobility, technology integration analysis. Additionally, other assistance as requested by PGE consistent with NREL’s expertise.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Technology Impact and Resource Assessment of Existing and Planned U.S. Biofuel Production: Life Cycle Water Consumption, Water Stress, Land Use, and Criteria Air Pollutants

Biofuels have the potential to strengthen the U.S. energy supply, enhance energy security, and promote economic development. As the United States continues to expand biofuel production, quantifying resource requirements and location-specific constraints is crucial for planning, siting, and technology development to support long-term viability. Accordingly, this work assesses the life cycle resource consumption (water consumption, and land use), water stress and criteria air pollutants associated with expanded U.S. biofuel production over the 2020–2035 period, based on producers’ plans. We perform a bottom-up technology impact assessment and resource assessment by integrating facility-level production statistics with Argonne’s Research and Development (R&D) GREET model and county-level water-stress characterization factors from Available Water Remaining for the United States (AWARE-US) model. Results suggest that by 2035, biofuels could meaningfully contribute to U.S. energy demand, driven primarily by first-generation and waste-based feedstocks with plans for substantial capacity expansion, although cellulosic and e-fuel technologies remain limited. However, growth must be managed to minimize impacts on water resources and land use. These impacts vary by fuel type and facility location, specifically, projected expansion increases water consumption and can elevate water-stress impacts in certain regions like Nebraska, Kansas, Colorado, Idaho, California and North Texas. Direct land use also increases overall, particularly for first-generation feedstocks such as corn and soybeans. These findings underscore the need for continued technological improvements and innovative strategies to manage resource demands as the industry scales and to support complementary deployment within the evolving U.S. energy system.

09 BIOMASS FUELS↗

Developing and Evaluating Metrics for Demand Flexibility in Buildings: Comparing Simulations and Field Data

Building demand flexibility (DF) has attracted significant attention in recent years among researchers, technology developers and control companies, aggregators, utilities, and many others. There are numerous challenges with today’s electricity systems such as managing peak demand capacity and integrating variable renewables into the grid. Flexible building loads can provide various grid services to help reduce electricity costs, smooth out renewables intermittency and balance supply and demand. Recognizing this, the US DOE is leading the Grid-interactive Efficient Buildings (GEB) initiative which includes research to evaluate the potential, availability and timing of flexible loads. In this paper we present load shed metrics for three building types – medium office, large office and retail store – and compare prototype simulation results with measured data from 12 actual buildings that participated in hot summertime utility demand response (DR) events. The DR strategies included varying zone temperature and reducing light levels. The magnitude of a key DF metric, “demand decrease intensity” (or “shed intensity”) (W/ft2), between the simulation results and field data are similar (14-32% differences) for both mean and median values, though the field data show much larger variation among DR events. The coefficient p-values from linear regression model tests showed that outside air temperature is a significant variable for the whole building shed intensity when the resetting zone temperature strategy is deployed. These findings support the concept of using prototype building simulation to estimate building DF and expanding future simulation research to additional building types and climate zones.

Liu, Jingjing↗

Charge Management for an Inductively Charged On-Demand Battery-Electric Shuttle Service with High Penetration of Renewable Energy

This paper presents a charge management control strategy for an on-demand battery-electric shuttle van operating at the National Renewable Energy Laboratory (NREL) campus and supported by day-time inductive charging at the vehicle's waiting spot. A new control algorithm has been proposed for reducing the demand charge costs incurred from wireless charging of the on-demand shuttle. A custom controller has been developed to monitor the shuttle, wireless charger, renewable energy generation, and various loads at NREL's campus, and regulate charging behavior for demand response. The intermittent renewable generation and sporadic operation of the on-demand shuttle service contribute to a high level of uncertainty in expected campus load profile, which must be carefully managed. The control algorithm predicts energy profile to estimate the mobility needs of the vehicle and maintain uninterrupted service during operation while still minimizing peak demand. The proposed controller has been designed and optimized using a Simulink model for the entire system. Next, it has been implemented and tested in real-time on the NREL campus. Two primary vehicle-use cases, charge sustaining and charge depletion operation, are tested under different load profiles and drive cycles to assess the controller's effectiveness at reducing peak demand and therefore demand charges. The proposed controller showed robust performance under different driving scenarios with high correlation between simulated and experimental data. The results showed that proper demand response can be achieved with an average of 94% reduction of charging loads during peak demand events.

ADVANCED PROPULSION SYSTEMS,ENERGY STORAGE↗

Distributed Solution Approach for a Stackelberg Pricing Game of Aggregated Demand Response

Demand-side management is a fundamental up-to-date strategy that transforms the traditional power grid to a modern smart grid where the flexible pricing mechanisms play a critical role in its successful implementation. In this paper, the pricing-demand response between a distribution system operator (DSO) and load aggregators (LAs) is modeled as a Stackelberg game, where the DSO is the price maker that adjusts its strategy based on observed responses from LAs. With the concerns of computational cost and privacy protection, two distributed solution approaches, particle swarm optimization and pattern search algorithm, are conducted and compared with the classical centralized backward induction approach. Numerical results on a small case study demonstrate the effectiveness of the proposed distributed solution approaches in leveraging flexible demand response potential.

Chen, Yang↗