Search NASA⌕ Search

SEARCH · Search NASA

Results for “Density measurement”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A comparison of equatorial electron densities measured by whistlers and by a satellite radio technique

Magnetospheric equatorial electron densities determined from whistler observations are compared with in situ satellite measurements of electron density along near-equatorial orbits. Whistler data was recorded at Siple and Palmer, Antarctica, while the sweep frequency receiver on ISEE-1 was used to measure plasma densities during passes within about 15 deg of the whistler station longitudes at L values between 3 and 5.2. The whistler and satellite data sets are found to be in good agreement for the three rendezvous considered, suggesting that the diffusive equilibrium model applied to calculate electron densities from whistler measurements was appropriate for the description of electron density distributions along field lines in the outer plasmasphere. Data also indicate that density enhancements within the whistler ducts were not more than about 30% of the mean or interduct level, and that there were no significant east-west density gradients within about 15 deg of whistler station longitudes over the L range of the study.

Carpenter, D. L.↗

Molecular Rayleigh Scattering Diagnostic for Dynamic Temperature, Velocity, and Density Measurements

A molecular Rayleigh scattering technique is developed to measure dynamic gas temperature, velocity, and density in unseeded turbulent flows at sampling rates up to 16 kHz. A high power CW laser beam is focused at a point in an air jet plume and Rayleigh scattered light is collected and spectrally resolved. The spectrum of the light, which contains information about the temperature and velocity of the flow, is analyzed using a Fabry-Perot interferometer. The circular interference fringe pattern is divided into four concentric regions and sampled at 1 and 16 kHz using photon counting electronics. Monitoring the relative change in intensity within each region allows for measurement of gas temperature and velocity. Independently monitoring the total scattered light intensity provides a measure of gas density. A low speed heated jet is used to validate the measurement of temperature fluctuations and an acoustically excited nozzle flow is studied to validate velocity fluctuation measurements. Power spectral density calculations of the property fluctuations, as well as mean and fluctuating quantities are presented. Temperature fluctuation results are compared with constant current anemometry measurements and velocity fluctuation results are compared with constant temperature anemometry measurements at the same locations.

Mielke, Amy R.↗

Electric field and plasma density measurements in the strongly driven daytime equatorial electrojet. I - The unstable layer and gradient drift waves. II - Two-stream waves

The results of electric field and plasma density measurements in the strongly driven daytime equatorial electrojet over Peru, made during the March 1983 Condor electrojet experiment from Punta Lobos, Peru, are discussed together with the rocket instrumentation used for the measurements and the pertinent payload dynamics. The overall characteristics of the irregularity layer observed in situ in the electrojet are described. Special consideration is given to the waves generated by the gradient drift instability (observed between 90 and 106.5 km) and to primary and secondary two-stream waves detected by the two probes on the topside between 103 and 111 km, where the electron current was considered to be strongest.

Pfaff, R. F.↗

Absolute electron density measurements in the equatorial ionosphere

Accurate measurement of the electron density profile and its variations is crucial to further progress in understanding the physics of the disturbed equatorial ionosphere. To accomplish this, a plasma frequency probe was included in the payload complement of two rockets flown during the Condor rocket campaign conducted from Peru in March 1983. This paper presents density profiles of the disturbed equatorial ionosphere from a night-time flight in which spread-F conditions were present and from a day-time flight during strong electrojet conditions. Results from both flights are in excellent agreement with simultaneous radar data in that the regions of highly disturbed plasma coincide with the radar signatures. The spread-F rocket penetrated a topside depletion during both the upleg and downleg. The electrojet measurements showed a profile peaking at 1.3 x 10 to the 5th per cu cm at 106 km, with large scale fluctuations having amplitudes of roughly 10 percent seen only in the upward gradient in electron density. This is in agreement with plasma instability theory. It is further shown that simultaneous measurements by fixed-bias Langmuir probes, when normalized at a single point to the altitude profile of electron density, are inadequate to correctly parameterize the observed enhancements and depletions.

Baker, K. D.↗

Electron density measurements of an inhomogeneous plasma using millimeter wave Fabry-Perot interferometers.

The electron density of a laboratory generated inhomogeneous plasma was measured using 60-90, GHz flat-plate and 150 GHz semi-confocal Fabry-Perot interferometers. The plasma was a negative glow-type and had a measured parabolic electron density profile. An analytical comparison between the derived equations of electron density for an assumed homogeneous plasma slab and an inhomogeneous plasma with parabolic distribution showed that the slab approximation was valid for such a profile. Comparison of measured values of electron density with those using X-band and K-band interferometers for the same plasma indicated good agreement.

Kendall, B. M.↗

Velocity, Temperature and Density Measurements in Supersonic Jets

Prediction of the flow field properties in supersonic jets using computational fluid dynamics (CFD) codes is challenging when there is a significant temperature difference between the jet core and the ambient air and/or compressibility effects are substantial. A benchmark set of flow field property data were obtained to assess current CFD capabilities and develop better modeling approaches for these turbulent flow fields where accurate calculation of turbulent heat flux is important. Three different convergent-divergent nozzles were investigated with exit Mach numbers of: 1.36, 1.63 and 2.0 at their perfectly expanded conditions. The conditions of the jet were set to obtain a temperature difference of zero between the jet core and the ambient air, and then the temperature difference was progressively increased, at the same jet Mach number. Particle Image Velocimetry (PIV), spontaneous rotational Raman scattering spectroscopy (SRS), Background Oriented Schlieren (BOS) and probe-based measurements were used to acquire high quality, spatially-resolved measurements of the mean and root mean square (rms) velocities as well as the mean and rms gas temperatures and densities in both hot and cold supersonic jet flows. The non-intrusive flow measurements are compared both against probe measurements and against standard Reynolds averaged Navier-Stokes (RANS) predictions of the supersonic jet flow properties.

Rotational Raman Spectroscopy↗

Spectral density measurements of gyro noise

Power spectral density (PSD) was used to analyze the outputs of several gyros in the frequency range from 0.01 to 200 Hz. Data were accumulated on eight inertial quality instruments. The results are described in terms of input angle noise (arcsec 2/Hz) and are presented on log-log plots of PSD. These data show that the standard deviation of measurement noise was 0.01 arcsec or less for some gyros in the passband from 1 Hz down 10 0.01 Hz and probably down to 0.001 Hz for at least one gyro. For the passband between 1 and 100 Hz, uncertainties in the 0.01 and 0.05 arcsec region were observed.

Truncale, A.↗

A study of density measurements in hypersonic helium tunnels using an electron beam fluorescence technique

A series of experiments have been conducted at Langley Research Center to determine the feasibility of using electron-beam fluorescence to measure the free-stream static density of gaseous helium flow over a wide range of conditions. These experiments were conducted in the Langley hypersonic helium tunnel facility and its 3-inch prototype. Measurements were made for a range of stagnation pressures and temperatures and produced free-stream number densities of 1.53 x 10 to the 23rd to 1.25 x 10 to the 24th molecules/cu m and static temperatures from 2 K to 80 K. The results showed the collision quenching cross section to be 4.4 x 10 to the -15th sq cm at 1 K and to have a weak temperature dependence of T to the 1/6. With knowledge of these two values, the free-stream number density can be measured quite accurately.

Honaker, W. C.↗

Local and Total Density Measurements in Ice Shapes

Preliminary measurements of local and total densities inside ice shapes were obtained from ice shapes grown in the NASA Glenn Research Tunnel for a range of glaze ice, rime ice, and mixed phase ice conditions on a NACA 0012 airfoil at 0 angle of attack. The ice shapes were removed from the airfoil and a slice of ice 3 mm thick was obtained using a microtome. The resulting samples were then x-rayed to obtain a micro-radiography, the film was digitized, and image processing techniques were used to extract the local and total density values.

Vargas, Mario↗

Shuttle high resolution accelerometer package experiment results - Atmospheric density measurements between 60-160 km

Indirect or inferred values of atmospheric density encountered by the Shuttle Orbiter during reentry have been calculated from acceleration measurements made by the High Resolution Accelerometer Package (HiRAP) and the Orbiter Inertial Measurement Unit (IMU) liner accelerometers. The atmospheric density data developed from this study represent a significant gain with respect to the body of data collected to date by various techniques in the altitude range of 60 to 160 km. The data are unique in that they cover a very wide horizontal range during each flight and provide insight into the actual density variations encountered along the reentry flight path. The data, which were collected over about 3 years, are also characterized by variations in solar activity, geomagnetic index, and local solar time. Comparison of the flight-derived densities with various atmospheric models have been made, and analyses have attempted to characterize the data and to show correlation with selected physical variables.

Blanchard, R. C.↗

Precision flux density measurements of the giant planets at 8420 MHz

Precision measurements of the 3.56 cm flux densities of Jupiter, Saturn, Uranus, and Neptune are reported. The results are compared with previously published measurements as a means of: (1) remotely sensing long-term changes in the microwave emission from the atmospheres of these planets; (2) measuring the effects of Saturn's rings on the disk temperature as observed from earth at different ring inclination angles.

Turegano, J. A.↗

Precision flux density measurements of the giant planets at 8420 MHz

Precision measurements of the 3.56 cm flux densities of Jupiter, Saturn, Uranus, and Neptune are reported. The results are compared with previously published measurements as a means of: remotely sensing long-term changes in the microwave emission from the atmospheres of these planets and measuring the effects of Saturn's rings on the disk temperature as observed from earth at different ring inclination angles.

Turegano, J. A.↗

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm-diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗

Time-dependent local density measurements in unsteady flows

A laser-induced fluorescence technique for measuring the relative time-dependent density fluctuations in unsteady or turbulent flows is demonstrated. Using a 1.5-W continuous-wave Kr(+) laser, measurements have been obtained in 0.1-mm diameter by 1-mm-long sampling volumes in a Mach 3 flow of N2 seeded with biacetyl vapor. A signal amplitude resolution of 2% was achieved for a detection frequency bandwidth of 10 kHz. The measurement uncertainty was found to be dominated by noise behaving as photon statistical noise. The practical limits of signal-to-noise ratios have been characterized for a wide range of detection frequency bandwidths that encompasses those of interest in supersonic turbulence measurements.

Mckenzie, R. L.↗

Sound Source Identification Through Flow Density Measurement and Correlation With Far Field Noise

Sound sources in the plumes of unheated round jets, in the Mach number range 0.6 to 1.8, were investigated experimentally using "casuality" approach, where air density fluctuations in the plumes were correlated with the far field noise. The air density was measured using a newly developed Molecular Rayleigh scattering based technique, which did not require any seeding. The reference at the end provides a detailed description of the measurement technique.

Panda, J.↗

Instrumentation for bone density measurement

Measurement system evaluates the integrated bone density over a specific cross section of bone. A digital computer converts stored bone scan data to equivalent aluminum calibration wedge thickness, and bone density is then integrated along the scan by using the trapezoidal approximation integration formula.

Meharg, L. S.↗