Search NASA⌕ Search

SEARCH · Search NASA

Results for “Diagnostic Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Converting existing optical detectors into fast x-ray detectors

Here, the very short burn time and small size of burning plasmas created at advanced laser-fusion facilities will require high-spatial-resolution imaging diagnostics with fast time resolution. These instruments will need to function in an environment of extremely large neutron fluxes that will cause conventional diagnostics to fail because of radiation damage and induced background levels. One solution to this challenge is to perform an ultrafast conversion of the x-ray signals into the optical regime before the neutrons are able to reach the detector and then to relay image the signal out of the chamber and into a shielded bunker, protected from the effects of these neutrons. With this goal in mind, the OMEGA laser was used to demonstrate high-temporal-resolution x-ray imaging by using an x-ray snout to image an imploding backlighter capsule onto a semiconductor. The semiconductor was simultaneously probed with the existing velocity interferometry system for any surface reflector (VISAR) diagnostic, which uses an optical streak camera and provided a one-dimensional image of the phase in the semiconductor as a function of time. The phase induced in the semiconductor was linearly proportional to the x-ray emission from the backlighter capsule. This approach would then allow a sacrificial semiconductor to be attached at the end of an optical train with the VISAR and optical streak camera placed in a shielded bunker to operate in a high neutron environment and obtain time-dependent one-dimensional x-ray images or time-dependent x-ray spectra from a burning plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intracardiac Electrical Imaging using the 12-lead ECG: A Machine Learning Approach using Synthetic Data

Current state-of-the-art techniques for non-invasive imaging of cardiac electrical phenomena require voltage recordings from dozens of different torso locations and anatomical models built from expensive medical diagnostic imaging procedures. Here this study aimed to assess if recent machine learning advances could alternatively reconstruct electroanatomical maps at clinically relevant resolutions using only the standard 12-lead electrocardiogram (ECG) as input. To that end, a computational study was conducted to generate a dataset of over 16000 detailed cardiac simulations, which was then used to train neural network (NN) architectures designed to exploit both spatial and temporal correlations in the ECG signal. Analysis over a validation set showed average errors in activation map reconstruction below 1.7 msec over 75 intracardiac locations. Furthermore, phenotypical patterns of activation and the morphology of the activation potential were correctly reconstructed. The approach offers opportunities to stratify patients non-invasively, both retrospectively and prospectively, using metrics otherwise only available through invasive clinical procedures.

59 BASIC BIOLOGICAL SCIENCES↗

Microwave Imaging and Holographic Diagnostic to Antennas in Cylindrical Near-Field Measurement

In this paper, the issues pertaining to microwave imaging and holographic diagnostic to antennas in cylindrical near-field measurements are addressed. The theoretical approach is based on expanding the work in [1] and [2] where a cylindrical wave expansion of the field on a cylindrical near-field surface is given. The sampling probe is modeled by its equivalent aperture current (idealized circular aperture) and incorporated into the near-field to far-field transformation. The method of steepest decent is applied to obtain the far-field. In its implementation, however, one could specify directly the angular spectrum at which the far-field is desired to be calculated without resorting to interpolation. The microwave imaging and holographic diagnostic is based on back projection where a plane wave expansion of the far-field is obtained. This approach necessitates the knowledge of the far-field at exact angular spectrum resulting from application of 2-D FFT. Hence, we were able to construct simply the near-field on a plane not necessarily on the aperture plane of the test antenna but also on planes perpendicular to the aperture plane [3]. And a 3-D high resolution and high precision antenna imaging of the test antenna is obtained from cylindrical near-field simulated measurements. In addition microwave holographic diagnostic of large NASA scatterometer radar antenna obtained from measured near-field on a cylindrical surface will be given if time permits.

Microwave Imaging Holographic↗

Application of high-speed, species-specific chemiluminescence imaging for laminar flame speed and Markstein length measurements in spherically expanding flames

A high-speed chemiluminescence imaging diagnostic system has been developed and characterized for measuring species-specific properties of spherically expanding flames, with the objective of obtaining synchronized measurements of multiple flame properties from a single flame experiment. The imaging system comprises a high-speed camera coupled to a high-speed image intensifier and optical filters to isolate emission from desired excited species. Here this study validates the diagnostic scheme specifically for measuring laminar flame speed and Markstein length from chemiluminescence at three wavelength bands corresponding to OH*, CH*, and total chemiluminescence, respectively. Mixtures of methane-air and methane/ethane-air were tested at initial conditions of atmospheric pressure and room temperature. An under-utilized methodology for computing unburned Markstein length from burned Markstein length was implemented. Flame speed modeling of each mixture was conducted in Chemkin using AramcoMech 2.0. No significant differences were observed between the results derived from the three emission wavelength bands for the flame speeds nor the Markstein lengths. For both of these properties, excellent agreement was observed between the experimental results and the values reported in the literature. Because laminar flame speed and Markstein length show no dependency on the imaging wavelength, the present results imply that multiple flame properties, such as laminar flame speed, Markstein length, flame thickness, and excited-species intensity profiles, can all be acquired simultaneously for the same flame using this method.

42 ENGINEERING↗

Limited-angle computed tomography with deep image and physics priors

Computed tomography is a well-established x-ray imaging technique to reconstruct the three-dimensional structure of objects. It has been used extensively in a variety of fields, from diagnostic imaging to materials and biological sciences. One major challenge in some applications, such as in electron or x-ray tomography systems, is that the projections cannot be gathered over all the angles due to the sample holder setup or shape of the sample. This results in an ill-posed problem called the limited angle reconstruction problem. Typical image reconstruction in this setup leads to distortion and artifacts, thereby hindering a quantitative evaluation of the results. To address this challenge, we use a generative model to effectively constrain the solution of a physics-based approach. Our approach is self-training that can iteratively learn the nonlinear mapping from partial projections to the scanned object. Because our approach combines the data likelihood and image prior terms into a single deep network, it is computationally tractable and improves performance through an end-to-end training. We also complement our approach with total-variation regularization to handle high-frequency noise in reconstructions and implement a solver based on alternating direction method of multipliers. We present numerical results for various degrees of missing angle range and noise levels, which demonstrate the effectiveness of the proposed approach.

47 OTHER INSTRUMENTATION↗

“Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation”

Radioisotopes are essential for the development and application of radiopharmaceuticals that target specific diseases, such as cancer, offering unique potential for precision medicine. The growing demand for theranostic radioisotopes underscores their critical role in personalized medicine, where they enhance diagnostic imaging, minimize patient radiation exposure, and improve targeted tissue uptake, particularly in receptor- and antigen-directed therapies. The theranostic pair terbium-155 (diagnostic) and terbium-161 (therapeutic) holds significant promise for advancing individualized, targeted, and dosimetry-driven radiotherapies. However, the United States currently lacks routine and reliable production of these isotopes. This project made significant progress toward addressing this supply issue by developing production and separation methods for terbium-155 and terbium-161 while also training the next generation of the nuclear and radiochemistry workforce. This grant also strengthened collaboration between scientists at the University of Washington, the University of Missouri and Brookhaven National Laboratory. The research effort focused on evaluating target preparation methods, optimizing irradiation parameters, and refining isolation processes. In addition, the project provided extensive hands-on training to graduate students and postdoctoral fellows, equipping them with expertise in radioisotope production technologies and fostering the growth of the nuclear science workforce.

07 ISOTOPE AND RADIATION SOURCES↗

Verification of diesel spray ignition phenomenon in dual-fuel diesel-piloted premixed natural gas engine

Dual-fuel (DF) engines, in which premixed natural gas and air in an open-type combustion chamber is ignited by diesel-fuel pilot sprays, have been more popular for marine use than pre-chamber spark ignition (PCSI) engines because of their superior durability. However, control of ignition and combustion in DF engines is more difficult than in PCSI engines. In this context, here we focus on the ignition stability of n-heptane pilot-fuel jets injected into a compressed premixed charge of natural gas and air at low-load conditions. To aid understanding of the experimental data, chemical-kinetics simulations were carried out in a simplified engine-environment that provided insight into the chemical effects of methane (CH4) on pilot-fuel ignition. The simulations reveal that CH4 has an effect on both stages of n-heptane autoignition: the small, first-stage, cool-flame-type, low-temperature ignition (LTI) and the larger, second-stage, high-temperature ignition (HTI). As the ratio of pilot-fuel to CH4 entrained into the spray decreases, the initial oxidization of CH4 consumes the OH radicals produced by pilot-fuel decomposition during LTI, thereby inhibiting its progression to HTI. Using imaging diagnostics, the spatial and temporal progression of LTI and HTI in DF combustion are measured in a heavy-duty optical engine, and the imaging data are analyzed to understand the cause of severe fluctuations in ignition timing and combustion completeness at low-load conditions. Images of cool-flame and hydroxyl radical (OH*) chemiluminescence serve as indicators of LTI and HTI, respectively. The cycle-to-cycle and spatial variation in ignition extracted from the imaging data are used as key metrics of comparison. The imaging data indicate that the local concentration of the pilot-fuel and the richness of the surrounding natural-gas air mixture are important for LTI and HTI, but in different ways. In particular, higher injection pressures and shorter injection durations increase the mixing rate, leading to lower concentrations of pilot-fuel more quickly, which can inhibit HTI even as LTI remains relatively robust. Decreasing the injection pressure from 80 MPa to 40 MPa and increasing the injection duration from 500 µs to 760 µs maintained constant pilot-fuel mass, while promoting robust transition from LTI to HTI by effectively slowing the mixing rate. This allows enough residence time for the OH radicals, produced by the two-stage ignition chemistry of the pilot-fuel, to accelerate the transition from LTI to HTI before being consumed by CH4 oxidation. Thus from a practical perspective, for a premixed natural gas fuel–air equivalence-ratio, it is possible to improve the “stability” of the combustion process by solely manipulating the pilot-fuel injection parameters while maintaining constant mass of injected pilot-fuel. This allows for tailoring mixing trajectories to offset changes in fuel ignition chemistry, so as to promote a robust transition from LTI to HTI by changing the balance between the local concentration of the pilot-fuel and richness of the premixed natural gas and air. This could prove to be a valuable tool for combustion design to improve fuel efficiency or reduce noise or perhaps even reduce heat-transfer losses by locating early combustion away from in-cylinder walls.

42 ENGINEERING↗

Image Processing System

Mallinckrodt Institute of Radiology (MIR) is using a digital image processing system which employs NASA-developed technology. MIR's computer system is the largest radiology system in the world. It is used in diagnostic imaging. Blood vessels are injected with x-ray dye, and the images which are produced indicate whether arteries are hardened or blocked. A computer program developed by Jet Propulsion Laboratory known as Mini-VICAR/IBIS was supplied to MIR by COSMIC. The program provides the basis for developing the computer imaging routines for data processing, contrast enhancement and picture display.

Source record↗

Analysis of streaked images of x-ray self-emission in laser-driven spherical implosions

Imaging of x-ray self-emission provides a powerful in situ measurement of the spatial and temporal evolution of high-energy-density plasmas. However, interpretation of these measurements requires detailed understanding of the data-generating process. This work presents a case study in the interpretation of x-ray self-emission data for the specific application of streaked one-dimensional slit imaging of spherical laser-driven implosions. A comprehensive generative model of the streaked slit-imaging diagnostic is developed including detailed treatments of the radiation transfer, photometrics, and photostatistics associated with the measurement. The model is used to generate realistic synthetic streaked images and to analyze experimental streaked images to extract important physical quantities of interest. An example analysis of streaked images from implosion experiments on the OMEGA laser is presented, where the model developed in this work is used to constrain the trajectory and peak velocity of the implosion using Bayesian inference.

Bayesian inference↗

Introduction to the special topic on inertial confinement fusion diagnostics

In the first decade of the 21st century, the United States began operating three leading Inertial Confinement Fusion (ICF) and High-Energy Density Physics (HEDP) facilities. The National Ignition Facility (NIF) began its quest to first surpass the Lawson Criterion and then reach thermonuclear ignition and thermonuclear gain. The Omega EP (Extended Performance) laser provides unprecedented energy, reliability, and consistency for petawatt (PW)-class laser experiments. The Omega laser continues to support over 1000 ICF and HEDP experiments each year. The Z pulsed power machine is a Z-pinch plasma confinement device that was refurbished to increase current drive and improve reliability. The extreme states of matter created in these new facilities required advancement of many technologies. The most important among these was the significant improvement in instrumentation capabilities needed to diagnose plasma conditions and resulting nuclear products. The instruments needed a better temporal, spatial, and energy resolution. They also needed to be hardened against EMP and radiation. Typical events in an ICF implosion include compressing the deuterium–tritium (DT) fuel to greater than 60 g/cm 3 and heating the DT to a temperature greater than 10 keV (110 000 000 K). The DT atoms react to produce 14 MeV neutrons from a volume with a radius of ~30 μm. When the fuel ignites, the DT burn prop agates into cold fuel and the neutron-emitting region can reach sizes of over 200 μm. Furthermore, the burn typically lasts less than 150 ps, but the burn duration will decrease as the DT yield increases. Burn durations as short as 90 ps have been recorded and are predicted to decrease still further to 20 ps. X-ray imaging diagnostics are needed to measure the acceleration and velocity of the capsule enclosing the DT, where the implosion velocities can reach over 400 km/s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

Production of High Specific Activity 155 Tb, 161 Tb and 203 Pb for Research and Clinical Applications: Effective Target Design, Target Material Recycling and Radioisotope Separation (Final Technical Report)

The overall objectives of this project were (1) to develop methods for the production and separation of a diagnostic and therapeutic or “theranostic” pair of radioisotopes, terbium-155 ( 155 Tb) and terbium-161 ( 161 Tb) and (2) to train graduate students and postdoctoral fellows in technologies and methods used in radionuclide production. Radionuclides can be incorporated into drugs called radiopharmaceuticals that target a specific disease (e.g., cancer). The need for theranostic radionuclides is escalating with the clinical translation of radiopharmaceuticals due to their implementation in personalized medicine, which has demonstrated enhanced patient treatments. High purity and high specific activity radionuclides are critical for theranostic agent development, for example to maintain diagnostic image quality, to minimize radiation dose to the patient, and to increase uptake in the targeted tissue (e.g., tumor), especially in the case of receptor- and antigen-targeted agents. The 155 Tb (diagnostic) and 161 Tb (therapeutic) radioisotopes that were generated through this project are a theranostic pair with demonstrated potential for the development and translation into individualized, targeted, and dosimetry-driven radiotherapies. However, the development of such radiotherapies has been hindered by the lack of a routine and reliable supply of these isotopes in the United States. Methods for the production, separation, and supply of 155 Tb and 161 Tb were investigated and developed in this project. Further, the strong emphasis throughout the project on the training of graduate students and postdoctoral fellows has helped to ensure and enhance the nuclear science workforce through the training of the next generation of highly qualified scientists in nuclear and radiochemistry. This grant also continued a collaboration between scientists at the University of Washington (UW), the University of Missouri (MU) and Brookhaven National Laboratory (BNL). All three institutions were involved in the project, but to different degrees on the various tasks through which the overall objectives were met.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of Human Research Facility Ultrasound With the ISS Video System

Most medical equipment on the International Space Station (ISS) is manifested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical situations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-operator during an exam to facilitate the diagnosis in a timely fashion. In this document, we strove to verify that the HRF ultrasound video output is compatible with the ISS video system, identify ISS video system field rates and resolutions that are acceptable for varying clinical scenaiios, and evaluate the HRF ultrasound video with a commercial, off-the-shelf video converter, and compare it with the ISS video system.

Melton, Shannon↗

Lunar Surface Reference Missions: A Description of Human and Robotic Surface Activities

Most medical equipment to the International Space Station (ISS) is manisfested as part of the U.S. or the Russian medical hardware systems. However, certain medical hardware is also available as part of the Human Research Facility. The HRF and the JSC Medical Operations Branch established a Memorandum of Agreement for joint use of certain medical hardware, including the HRF ultrasound system, the only diagnostic imaging device currently manifested to fly on ISS. The outcome of a medical contingency may be changed drastically, or an unnecessary evacuation may be prevented, if clinical decisions are supported by timely and objective diagnostic information. In many higher-probability medical scenarios, diagnostic ultrasound is a first-choice modality or provides significant diagnostic information. Accordingly, the Clinical Care Capability Development Project is evaluating the HRF ultrasound system for its utility in relevant clinical siruations on board ISS. For effective management of these ultrasound-supported ISS medical scenarios, the resulting data should be available for viewing and interpretation on the ground, and bidirectional voice communication should be readily available to allow ground experts (sonographers, physicians) to provide guidance to the Crew Medical Officer. It may also be vitally important to have the capability of real-time guidance via video uplink to the CMO-opertor during an exam to facilitate the diagnosis in a timely fashion.

Duke, Michael B.↗

A Specialized Ultrasound Protocol for NASA's Renal Stone Surveillance and Clinical Practice

INTRODUCTION Ample evidence exists on the effectiveness of ultrasound in the diagnosis of kidney stones. However, terrestrial practice is mostly concerned with diagnosis of clinically significant urolithiasis. Adapting this non-irradiating, low-cost imaging modality for the asymptomatic astronaut population offers high-sensitivity screening and limits their career radiation dose. METHODS NASA developed a novel ultrasound-based detection and surveillance protocol to identify, categorize, and monitor mineralized renal material (MRM) in astronauts. The term MRM was developed to denote abnormal, presumably calcified, focal material of unknown clinical significance in the kidneys. Sonographic criteria for MRMs include measurable echogenic foci, their detectability in multiple, designated imaging plains, posterior shadowing, and “twinkle” pattern visualized in Color Doppler and/or demonstrated in Spectral Doppler modes. The mere discovery of an MRM does not trigger further imaging or intervention, unless the affected crewmember is mission-assigned, or the MRM meets actionable criteria based on size, location, and sonographic characteristics. If the threshold is met, the crew surgeon is notified, and additional diagnostic imaging and urology consultation are considered. RESULTS In total, 73 individuals have been scanned using our specialized methods, 60 have had more than one study done. As of April 2023, 282 total studies have been performed. So far, over 30 pairs of pre-and postflight studies have been obtained, and the findings are presented elsewhere in this panel. DISCUSSION A surveillance program was initiated nine years ago to screen asymptomatic members of the astronaut corps for renal calcifications, from their initial hiring, through their mission timeframes, and throughout their career. The goal is to reduce the probability that an astronaut will fly with a renal stone that may become symptomatic. This also gives NASA the information it needs to improve screening criteria for future long-duration crewed missions.

H Lyons↗

Acoustic Holography of the Solar Convection Zone with SOHO-MDI Observations

The original grant with the title stated above was NAG5-10984, awarded to the Solar Physics Research Corporation (SPRC) in July, 2001, and was to be a three-year project. The basic theme of the project was the development and application of computational seismic holography for imaging, diagnostics, and monitoring of magnetic anomalies beneath active regions, in the deep solar interior, and on the Sun's far surface. The project was roughly separated into the following five tasks: (1) A holographic survey of active regions. (2) p-Mode absorption diagnostics of magnetic regions. (3) Acoustic modeling of the shallow subphotospheres of active regions and the quiet-Sun supergranulation based on phase-correlation seismic holography. (4) Seismic holography of the deep convection zone. (5) Improvements in holographic imaging of the far surface of the Sun. Following the death of Karen Harvey, President of SPRC, during the first year, the grant was transferred to Northwest Research Associates as NAG5-12901. Substantial but progress had been made on most of the above tasks in the first year under NAG5-10984, but none were completed. This work was continued under NAG5-12901.

Lindsey, Charles↗

Moly 99 Reactor Case Study

Molybdenum-99 (Moly 99) is a critical raw material for Technetium (Tc) 99m, a radioactive isotope most widely used in nuclear medicine procedures. Moly 99 has a short half-life of about six hours, which means it cannot be stockpiled. When Moly 99 decays, it turns into Tc 99m, which has a half-life of 214,000 years. The photon energy emitted from the decay of Moly 99 is used in a variety of nuclear imaging technologies such as gamma cameras. Furthermore, radiopharmaceutical manufacturers use the photon energy emitted from the decay of Moly 99 to produce generators for hospitals, clinics, and radiopharmacies. Once Moly 99 decays to Tc 99m, it is used to make individual patient doses for a variety of diagnostic imaging procedures. The Moly 99 Reactor Design is a conceptual blueprint for Moly 99 production that does not use weapon-grade uranium; instead, the reactor has a target core of low-enriched uranium. The reactor design is small, reaching a foot-and-a-half in height and diameter and consumes less than two megawatts of power. The reactor's only purpose is for medical isotope production and with every fission, Moly 99 is produced.

07 ISOTOPE AND RADIATION SOURCES↗

Radioarsenic: A promising theragnostic candidate for nuclear medicine

Molecular imaging is a non-invasive process that enable the visualization, characterization, and quantitation of biological processes at the molecular and cellular level. With the emergence of theragnostic agents to diagnose and treat disease for personalized medicine there is a growing need for matched pairs of isotopes. Matched pairs offer the unique opportunity to obtain patient specific information from SPECT or PET diagnostic studies to quantitate in vivo function or receptor density to inform and tailor therapeutic treatment. There are several isotopes of arsenic that have emissions suitable for either or both diagnostic imaging and radiotherapy. Their half-lives are long enough to pair them with peptides and antibodies which take longer to reach maximum uptake to facilitate improved patient pharmacokinetics and dosimetry then can be obtained with shorter lived radionuclides. Arsenic-72 even offers availability from a generator that can be shipped to remote sites and thus enhances availability. Arsenic has a long history as a diagnostic agent, but until recently has suffered from limited availability, lack of suitable chelators, and concerns about toxicity have inhibited its use in nuclear medicine. However, new production methods and novel chelators are coming online and the use of radioarsenic in the pico and nanomolar scale is well below the limits associated with toxicity. This manuscript will review the production routes, separation chemistry, radiolabeling techniques and in vitro/in vivo studies of three medically relevant isotopes of arsenic (arsenic-74, arsenic-72, and arsenic-77).

07 ISOTOPE AND RADIATION SOURCES↗