Compact, Large Solid Angle Coverage Neutron Diffractometer
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A new large radius imaging plate diffraction camera for high-resolution and high-throughput synchrotron x-ray powder diffraction by means of multiple exposures has been developed for an insertion device beamline of SPring-8, Japan. The new imaging plate camera consists of a large radius cylindrical shape imaging plate cassette that is 400 mm in length and 954.9 mm in cylinder radius. The cassette is designed to be mounted on the 2{theta} arm of the diffractometer of BL15XU in SPring-8. One imaging plate covers 24 deg. and several times of exposure changing the 2{theta}-setting angle is necessary to obtain whole powder diffraction data up to a high angle region. One pixel of the imaging plate corresponds to 0.003 deg. in 2{theta} when the readout pixel size is 50 {mu}m squares. Separately collected data are translated to 2{theta}-intensity format and are connected by comparing the peak and background intensity included in the overlapped area. The exposure time is less than 120 s for most samples and the readout time is about 3 min; thus, the total measurement time for one powder diffraction pattern is less than 20 min. The measurement time is the same order as the continuous 2{theta}-scanning method of the third generation synchrotron powder diffractometer. The angular resolution of the new imaging plate camera was evaluated by comparing the full width at half maximum of the 111 reflection of NBS-Si. The observed angular resolution is not so high as a powder diffractometer with a Si or a Ge analyzer monochromator in the third generation synchrotron facility but higher than a powder diffractometer with a Ge analyzer monochromator at a bending magnet beamline of the second generation synchrotron. The Rietveld analysis of NBS-CeO{sub 2} was successfully carried out with the data taken by the new imaging plate camera.
Here, a `2D + λ' mode using two detector angles and wavelength is added to the modes of operation of a six-circle diffractometer, i.e. `4S + 2D' diffractometer [You (1999). J. Appl. Cryst. 32, 614–623]. In synchrotron sources, the X-ray energy, and hence the wavelength, can be a degree of freedom for angle calculations. For diffractometers with two detector circles, therefore, the variable X-ray energy can be the third degree of freedom, sufficient for accessing reciprocal space without rotating the sample. This mode is useful for limited sample rotations or X-ray beams focused smaller than the diffractometer circle of confusion.
High-resolution crystallographic studies of the hydration of the coenzyme cob(II)alamin have provided hydrogen-bond parameters of unprecedented accuracy for a biomacromolecule. The hydration of the coenzyme cob(II)alamin has been studied using high-resolution monochromatic neutron crystallographic data collected at room temperature to a resolution of 0.92 Å on the original D19 diffractometer with a prototype 4° × 64° detector at the high-flux reactor neutron source run by the Institute Laue–Langevin. The resulting structure provides hydrogen-bonding parameters for the hydration of biomacromolecules to unprecedented accuracy. These experimental parameters will be used to define more accurate force fields for biomacromolecular structure refinement. The presence of a hydrophobic bowl motif surrounded by flexible side chains with terminal functional groups may be significant for the efficient scavenging of ligands. The feasibility of extending the resolution of this structure to ultrahigh resolution was investigated by collecting time-of-flight neutron crystallographic data during commissioning of the TOPAZ diffractometer with a prototype array of 14 modular 2° × 21° detectors at the Spallation Neutron Source run by Oak Ridge National Laboratory.
The high-intensity time-of-flight (TOF) neutron diffractometer POWTEX for powder and texture analysis is currently being built prior to operation in the eastern guide hall of the research reactor FRM II at Garching close to Munich, Germany. Because of the world-wide 3 He crisis in 2009, the authors promptly initiated the development of 3 He-free detector alternatives that are tailor-made for the requirements of large-area diffractometers. Herein is reported the 2017 enterprise to operate one mounting unit of the final POWTEX detector on the neutron powder diffractometer POWGEN at the Spallation Neutron Source located at Oak Ridge National Laboratory, USA. As a result, presented here are the first angular- and wavelength-dependent data from the POWTEX detector, unfortunately damaged by a 50 g shock but still operating, as well as the efforts made both to characterize the transport damage and to successfully recalibrate the voxel positions in order to yield nonetheless reliable measurements. Also described is the current data reduction process using the PowderReduceP2D algorithm implemented in Mantid [Arnold et al. (2014). Nucl. Instrum. Methods Phys. Res. A , 764 , 156–166]. The final part of the data treatment chain, namely a novel multi-dimensional refinement using a modified version of the GSAS-II software suite [Toby & Von Dreele (2013). J. Appl. Cryst. 46 , 544–549], is compared with a standard data treatment of the same event data conventionally reduced as TOF diffraction patterns and refined with the unmodified version of GSAS-II . This involves both determining the instrumental resolution parameters using POWGEN's powdered diamond standard sample and the refinement of a friendly-user sample, BaZn(NCN) 2 . Although each structural parameter on its own looks similar upon comparing the conventional (1D) and multi-dimensional (2D) treatments, also in terms of precision, a closer view shows small but possibly significant differences. For example, the somewhat suspicious proximity of the a and b lattice parameters of BaZn(NCN) 2 crystallizing in Pbca as resulting from the 1D refinement (0.008 Å) is five times less pronounced in the 2D refinement (0.038 Å). Similar features are found when comparing bond lengths and bond angles, e.g. the two N—C—N units are less differently bent in the 1D results (173 and 175°) than in the 2D results (167 and 173°). The results are of importance not only for POWTEX but also for other neutron TOF diffractometers with large-area detectors, like POWGEN at the SNS or the future DREAM beamline at the European Spallation Source.
HKL-IOC is an open source EPICS IOC that performs real‑time crystallographic HKL calculations for diffractometers and scattering instruments. It integrates the Python hkl library with EPICS through PyDevice, exposing HKL calculations and diffractometer geometry transformations as standard EPICS process variables. This allows beamline and laboratory control systems to convert between motor positions and reciprocal‑space coordinates, configure diffractometer geometries, and drive scans directly in HKL space. The software is written in Python and designed to run alongside existing EPICS deployments without requiring changes to core EPICS components. It is intended for use at synchrotron and neutron scattering facilities, as well as laboratory X‑ray diffractometers, where reliable and reproducible HKL calculations are needed for experiment control, data collection, and automation. HKL-IOC is distributed under the GNU General Public License v3.0 (GPL‑3.0) and contributions and extensions for additional geometries and beamlines are welcomed.
The high-resolution Fourier diffractometer (HRFD) was commissioned at the IBR-2 pulsed reactor at FLNP JINR in 1994. The specific feature of the HRFD design is the use of fast Fourier chopper for modulating the primary neutron beam intensity and the correlation method of diffraction data acquisition. This allowed to reach with HRFD extremely high resolution (Δ d / d ≈ 0.001) over a wide range of inter-planar spacings at a relatively short flight path between chopper and sample (L = 20 m). Over time, a lot of diffraction experiments on crystalline materials, the main goal of which was to study their atomic and magnetic structures, were performed at HRFD. Successful implementation of the Fourier diffractometry technique at the IBR-2 reactor stimulated the construction of yet another Fourier diffractometer intended for internal mechanical stress studies in bulk materials (FSD, Fourier Stress Diffractometer). In this paper the experience of using this technique at the IBR-2, which is a long-pulse neutron source, is considered, the examples of HRFD studies are given, and possible solutions for existing technical problems of using correlation diffractometry and ways of increasing the intensity and resolution of HRFD are discussed.
GSAS instrument parameters are tabulated for a variety of laboratory and synchrotron diffractometers to give users an idea of the typical ranges of profile parameters when they generate their own instrument parameter files. For modern high-resolution laboratory diffractometers, the parameters fall in the ranges 0 < U < 3, V = 0, 0 < W < 4, 1 < X < 3, 0 < Y < 3, 1 < asym < 3, and 0 < S/L < 0.03. For synchrotron diffractometers, the parameters fall in the ranges 0 < U < 1.2, -1 < V < 0, 0 < W < 1, 0 < X < 1, 0 < Y < 1, 0 < asym < 0.5, 0 < S/L < 0.001, and 0 < H/L < 0.007. FULLPROF equivalents are also reported. The factors which are convoluted together to generate the instrument profile are described.
Crystallization trial is one of the most important but time-consuming steps in macromolecular crystallography, and in-situ diffraction experiment has a capability to make researchers to proceed this step more efficiently. At the Photon Factory, a new tabletop diffractometer for in-situ diffraction experiments has been developed. It consists of XYZ translation stages with a plate handler, an on-axis viewing system and a plate rack with a capacity for ten crystallization plates. These components sit on a common plate and are able to be placed on the existing diffractometer table. The CCD detector with a large active area and a pixel array detector with a small active area are used for acquiring diffraction images from crystals. Dedicated control software and a user interface have also been developed. The new diffractometer has been operational for users and used for evaluation of crystallization screening since 2014.
Neutron diffraction texture measurements provide bulk averaged textures with excellent grain orientation statistics, even for large-grained materials, owing to the probed volume being of the order of 1 cm 3 . Furthermore, crystallographic parameters and other valuable microstructure information such as phase fraction, coherent crystallite size, root-mean-square microstrain, macroscopic or intergranular strain and stress, etc. can be derived from neutron diffractograms. A procedure for combined high stereographic resolution texture and residual stress evaluation was established on the pulsed-neutron-source-based engineering materials diffractometer TAKUMI at the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Research Center, through division of the neutron detector panel regions. Pole figure evaluation of a limestone standard sample with a well known texture suggested that the precision obtained for texture measurement is comparable to that of the established neutron beamlines utilized for texture measurement, such as the HIPPO diffractometer at the Los Alamos Neutron Science Center (New Mexico, USA) and the D20 angle-dispersive neutron diffractometer at the Institut Laue–Langevin (Grenoble, France). A high-strength martensite–austenite multilayered steel was employed for further verification of the reliability of simultaneous Rietveld analysis of multiphase textures and macro stress tensors. By using a texture-weighted geometric mean micromechanical (BulkPathGEO) model, a macro stress tensor analysis with a plane stress assumption showed a rolling direction–transverse direction (RD–TD) in-plane compressive stress (about –330 MPa) in the martensite layers and an RD–TD in-plane tensile stress (about 320 MPa) in the austenite layers. The phase stress partitioning was ascribed mainly to the additive effect of the volume expansion during martensite transformation and the linear contraction misfit between austenite layers and newly transformed martensite layers during the water quenching process.
In this paper, we report on the crystal structures of Nb 2 AlC and TiNbAlC actual composition (Ti 0.45 ,Nb 0.55 ) 2 AlC compounds determined from Rietveld analysis of neutron diffraction patterns in the 300-1173 K temperature range. The average linear thermal expansion coefficients of a Nb 2 AlC sample in the a and c directions are, respectively, 7.9(5)x10 -6 K -1 and 7.7(5)x10 -6 K -1 on one neutron diffractometer and 7.3(3)x10 -6 K -1 and 7.0(2)x10 -6 K -1 on a second diffractometer. The respective values for the (Ti 0.45 ,Nb 0.55 ) 2 AlC composition - only tested on one diffractometer - are 8.5(3)x10 -6 K -1 and 7.5(5)x10 -6 K -1 . These values are relatively low compared to other MAX phases. Like other MAX phases, however, the atomic displacement parameters show that the Al atoms vibrate with higher amplitudes than the Ti and C atoms, and 1 more along the basal planes than normal to them. In addition, when the predictions of the atomic displacement parameters obtained from density functional theory are compared to the experimental results, good quantitative agreement is found for the Al atoms. In case of the Nb and C atoms, the agreement was more qualitative.
This paper addresses several aspects of the scientific utilization of the Oak Ridge National Laboratory High Flux Isotope Reactor (HFIR). Topics to be covered will include: 1) HFIR neutron scattering instruments and the formal instrument user program; 2) Recent upgrades to the neutron scattering instrument stations at the reactor, and 3) eMod a new tool for addressing instrument modifications and providing configuration control and design process for scientific instruments at HFIR and the Spallation Neutron Source (SNS). There are 15 operating neutron instrument stations at HFIR with 12 of them organized into a formal user program. Since the last presentation on HFIR instruments at IGORR we have installed a Single Crystal Quasi-Laue Diffractometer instrument called IMAGINE; and we have made significant upgrades to HFIR neutron scattering instruments including the Cold Triple Axis Instrument, the Wide Angle Neutron Diffractometer, the Powder Diffractometer, and the Neutron Imaging station. In addition, we have initiated upgrades to the Thermal Triple Axis Instrument and the Bio-SANS cold neutron instrument detector system. All of these upgrades are tied to a continuous effort to maintain a high level neutron scattering user program at the HFIR. For the purpose of tracking modifications such as those mentioned and configuration control we have been developing an electronic system for entering instrument modification requests that follows a modification or instrument project through concept development, design, fabrication, installation, and commissioning. This system, which we call eMod, electronically leads the task leader through a series of questions and checklists that then identifies such things as ES&H and radiological issues and then automatically designates specific individuals for the activity review process. The system has been in use for less than a year and we are still working out some of the inefficiencies, but we believe that this will become a very effective tool for achieving the configuration and process control believed to be necessary for scientific instrument systems.
Here, neutron diffraction and spectroscopies offer unique insight into structures and properties of solids and molecular materials. All neutron instruments located at the various neutron sources are distinct, even if their designs are based on similar principles, and thus, are usually less familiar to the community than commercial X–ray diffractometers and optical spectrometers. Major neutron instruments in the USA, which are open to scientists around the world, and examples of their use in coordination chemistry research are presented here, along with a list of similar instruments at main neutron facilities in other countries. The reader may easily and quickly find from this mini–review an appropriate neutron instrument for research. The instruments include single–crystal and powder diffractometers to determine structures, inelastic neutron scattering (INS) spectrometers to probe magnetic and vibrational excitations, and quasielastic neutron scattering (QENS) spectrometers to study molecular dynamics such as methyl rotation on ligands. Key and unique features of the diffraction and neutron spectroscopies that are relevant to inorganic chemistry are reviewed.
We have developed an ultrahigh-vacuum instrument for resonant diffraction experiments using polarized soft x rays in the energy range of h{nu}=300-2000 eV at beamline BL17SU of SPring-8. The diffractometer consists of modified differentially pumped rotary feedthroughs for {theta}-2{theta} stages, a sample manipulator with motor-controlled x-y-z-, tilt ({chi})-, and azimuth ({phi})-axes, and a liquid helium flow-type cryostat for temperature dependent measurements between 30 and 300 K. Test results indicate that the diffractometer exhibits high reproducibility (better than 0.001 deg.) for a Bragg reflection of {alpha}-quartz 100 at a photon energy of h{nu}=1950 eV. Typical off- and on-resonance Bragg reflections in the energy range of 530-1950 eV could be measured using the apparatus. The results show that x-ray diffraction experiments with energy-, azimuth-, and incident photon polarization-dependence can be reliably measured using soft x rays in the energy range of {approx}300-2000 eV. The facility can be used for resonant diffraction experiments across the L-edge of transition metals, M-edge of lanthanides, and up to the Si K-edge of materials.
We have developed a compact ultrafast electron diffractometer, consisting of a laser-driven rf photocathode that generates 3.0 MeV probe electron pulses, three-stage lens optics, and a custom-built detector for relativistic electrons. High-quality single-shot transmission electron diffraction has been detected from 180-nm-thick Si single crystals, with an excellent special resolution for diffracted beams; the spot width of 0.02 A{sup -1} is obtained. The pulse width is estimated to be 100 fs in duration. Characteristics of the electron beam and other diffractometer features are discussed.
A resistive furnace combined with a load frame was built that allows for in situ neutron diffraction studies of high temperature deformation, in particular, creep. A maximum force of 2700 N can be applied at temperatures up to 1000 deg. C. A load control mode permits studies of, e.g., creep or phase transformations under applied uni-axial stress. In position control, a range of high temperature deformation experiments can be achieved. The examined specimen can be rotated up to 80 deg. around the vertical compression axis allowing texture measurements in the neutron time-of-flight diffractometer HIPPO (High Pressure - Preferred Orientation). We present results from the successful commissioning, deforming a Zr-2.5 wt.% Nb cylinder at 975 deg. C. The device is now available for the user program of the HIPPO diffractometer at the LANSCE (Los Alamos Neutron Science Center) user facility.
In the growing field of in operando and in situ X-ray experiments, there exists a large disparity in the types of environments and equipment to control them. This situation makes it challenging to conduct multiple experiments with a single mechanical interface to the diffractometer. Here, we describe the design and implementation of a modular instrument mounting system that can be installed on a standard six-circle diffractometer (e.g., 5021 Huber GmbH). This new system allows for the rapid changeover of different chambers and sample heaters and permits accurate sample positioning (x, y, z, and azimuthal rotation) without rigid coupling to the chamber body. Isolation of the sample motion from the chamber enclosure is accomplished through a combination of custom rotary seals and bellows. Control of the pressure and temperature has been demonstrated in the ranges of 10{sup -6}-10{sup 3} Torr and 25 Degree-Sign C-900 Degree-Sign C, respectively. We have utilized the system with several different modular instruments. As an example, we provide in situ sputtering results, where the growth dynamics of epitaxial LaGaO{sub 3} thin films on (001) SrTiO{sub 3} substrates were investigated.