Search NASA⌕ Search

SEARCH · Search NASA

Results for “Direct Current (DC)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Performance Evaluation of Three RTU Energy Efficiency Technologies

This project was part of an effort by CLEAResult and ComEd to evaluate the energy saving potential of emerging technologies in the Chicago area. This project focused on evaluating emerging technologies related to rooftop units (RTUs). An RTU with a single-stage compressor and a constant-speed fan with an induction motor was selected as the baseline for technology comparison. Three retrofit strategies were investigated. The first two involved replacing the single-stage compressor of an RTU by either a two-stage or variable-speed compressor and adding a variable frequency drive (VFD) to the constant speed fan. The use of a multi-/variable-stage compressor improves the part-load efficiency of the compressor which will ultimately result in annual energy savings as well as peak demand shaving in some cases where the design capacity of the RTU is larger than the maximum cooling load of the building space that it is serving. The third technology was the use of a high rotor pole switched reluctance motor (SRM) as a replacement for the constant-speed supply fan. The SRM was applied in single-speed, two-stage and variable-speed compressor RTUs. SRM motors run via reluctance torque. Their stator poles are driven by direct current (DC) power and require an inverter as well as active control when using alternating current (AC) power. This inherent property results in high efficiency over a range of operating conditions. It also exhibits higher efficiency compared to variable frequency drives (VFDs) since its switching frequency is much slower (SCE, 2018).The three technologies investigated are summarized below: 1) Replacing the single-speed compressor with a two-stage compressor and adding a VFD to the supply fan. 2)Replacing the single-speed compressor with a variable-speed compressor and adding a VFD to the supply fan. 3) Replacing the constant-speed induction motor of the supply fan with a high rotor pole SRM. DOE’s building simulation platform EnergyPlus and its graphical user interface OpenStudio were used to evaluate the energy-saving potential of upgrading RTUs, by leveraging experimental data from previous research.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ganged-PV System Evaluation

The following report contains data and data summaries collected for the SkySun LLC elevated Ganged PV arrays. These arrays were fabricated as a series of PV panels in various orientations, suspended by cables, at the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL). Starting in February of 2021, Sandia personnel have collected power and accelerometer data for these arrays to assess design and operational efficacy of varying ganged- PV configurations. The purpose of this power data collection was to see how the various array orientations compare in power collection capability depending on the time of day, year, and the specific daily solar direct normal irradiance (DNI). The power data was collected as a measurement of the power output from the various series strings. The project team measured direct current (DC) voltage and current from the respective arrays. The accelerometer data was collected with the purpose of demonstrating potential destructive mode shapes that could take place with each of the arrays when exposed to high winds. This allowed the team to evaluate whether impacts with respect to specific array orientations using suspended cables is a safe design. All data collection was performed during calendar year 2021.

14 SOLAR ENERGY↗

U.S. Solar Photovoltaic System and Energy Storage Cost Benchmark: Q1 2021 [Slides]

Our benchmarking method includes bottom-up accounting for all necessary system and projectdevelopment costs incurred when installing residential, commercial, and utility-scale systems, and it models the Q1 2021 costs for such systems, excluding any previous supply agreements or contracts. In general, we attempt to model the typical installation techniques and business operations from an installed-cost perspective, and our benchmarks are national averages. The residential PV-only benchmark and the commercial rooftop PV-only benchmark average costs by inverter type (string inverters, string inverters with direct current [DC] optimizers, and microinverters), weighted by inverter market share. The residential PV-only benchmark is further averaged across small installer and national integrator business models, weighted by market share. All benchmarks include variations—accounting for the differences in size, equipment, and operational use (particularly for storage)—that are currently available in the marketplace. All benchmarks assume nonunionized construction labor; residential and commercial PV systems predominantly use nonunionized labor, and the type of labor required for utility-scale PV systems depends heavily on the development process. All benchmarks assume the use of monofacial monocrystalline silicon PV modules. Benchmarks using cadmium telluride or bifacial modules could result in significantly different results. The data in this annual benchmark report inform the formulation of and track progress toward the U.S. Department of Energy (DOE) Solar Energy Technologies Office’s Government Performance and Reporting Act cost targets.

14 SOLAR ENERGY↗

NDE Technology Engineering Program for Hanford DST Non-Visual Volumetric Inspection Technology: Phase II RAVIS Radiation Tolerance Test Report

This test report provides the results of radiation tolerance robustness testing that was performed on samples of robotic components and an ultrasonic guided wave air-slot sensor that represent components/sub-systems of the Robotic Air-slot Volumetric Inspection System (RAVIS) that has been engineered for volumetric inspection of Hanford tank bottom plates via under-tank refractory pad air-slots. The specific components tested for 1) functionality during active irradiation and 2) tolerance to cumulative radiation dose (until failure or upon reaching a cumulative dose test limit) were: • four samples each of a printed circuit board (PCB) and direct current (DC) motor, which are robotic components, and • 26 ultrasonic piezoelectric elements (samples) inside an air-slot sensor. The robotic components are part of the RAVIS air-slot inspection crawler drive control system that is responsible for remote communication with and actuation of the air-slot inspection crawler. The failure of either of these components during under-tank deployment would require manual retrieval via the crawler’s tether, which risks damage to the robot/refractory/tank. Preemptive replacement of the components at appropriately conservative dose/time intervals informed by failure dose would reduce the likelihood of under-tank failure. The components were included in radiation tolerance testing to quantify their failure doses to inform replacement intervals. The air-slot sensor is responsible for collecting ultrasonic inspection data (scan images) for the tank bottom plates during under-tank deployment. Compromised signal quality due to elevated noise levels caused by gamma radiation would compromise inspection performance. The air-slot sensor was included in radiation tolerance testing to quantify the impact of active irradiation on sensor signal quality. The irradiation and in-situ functional tests of the PCBs, DC motors and air-slot sensor took place in June and July 2020 at the Pacific Northwest National Laboratory. Testing was performed at a gamma dose rate near 300 rad/hr., which, in the absence of under-tank dose rate data, has been conservatively estimated to be the upper-bound dose rate beneath the primary tanks at Hanford. Irradiation took place at elevated temperatures of 150-200°F to determine failure doses that reflect the compounding effects of gamma radiation and heat. The test results revealed: • The DC motors can tolerate being actively irradiated at the high dose rate at 200°F and can tolerate a cumulative dose of 300,000 rad, that which would be incurred after 5 years of service at the 300 rad/hr dose rate. The component therefore meets minimum and preferred radiation tolerance and lifecycle requirements for robotic components. • The air-slot sensor can tolerate being actively irradiated at the high dose rate at 150°F and can tolerate a cumulative dose of 60,000 rad, that which would be incurred after 1 year of service at the 300 rad/hr dose rate. The sensor therefore meets minimum radiation tolerance and lifecycle requirements. • The PCB can tolerate being actively irradiated at the high dose rate, but can only tolerate a cumulative dose of 19,000 rad at 150-200°F. The PCB does not meet minimum radiation tolerance and lifecycle requirements; however, because the component is considered replaceable, it can be replaced before a cumulative dose of 19,000 rad is reached, determined through either monitoring with a dosimeter or scheduled time intervals that are calculated based on conservative estimates of under-tank dose rates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solar Photovoltaics: Supply Chain Deep Dive Assessment

This is one of a series of reports and deep dive assessments produced in response to Executive Order 14017 “America’s Supply Chains,” which directs the Secretary of Energy to submit a report on supply chains for the energy sector industrial base. The Executive Order is helping the federal government to build more secure and diverse U.S. supply chains, including energy supply chains. Over the past decade, solar power has gone from an emerging, niche technology to a mature energy industry. By 2035, solar power could supply 40% or more of U.S. electricity demand, dramatically accelerating the decarbonization of buildings, transportation, and industry; and, if current technology trends continue, it could do so without increasing the price of electricity. The rapid expansion of solar energy has the potential to yield broad benefits in the form of economic activity and workforce development. The solar industry already employs roughly 230,000 people in the United States, at an average wage that is higher than the national average for most comparable positions. By decarbonizing the electricity sector by 2035, the U.S. solar industry could employ 500,000–1,500,000 people by 2030. The components that are assembled to install a photovoltaic power system are produced by a global supply chain. Photovoltaic (PV) modules (also called panels) are made of cells that use a variety of technologies. There are two leading types of solar modules used in the United States, with crystalline silicon (c-Si) modules representing 84% of the market and cadmium telluride (CdTe) modules representing 16% of the market. Modules of either type require mounting structures to provide mechanical support (racking), which may be configured to follow the sun (tracking). The output of any PV module is direct current (dc), which is almost always converted to alternating current (ac) by an inverter.

14 SOLAR ENERGY↗

Charge per Micro-Pulse Calculation for Ideal Lujan and WNR beams

A complete redesign of the LANSCE front-end is currently under development for the Los Alamos Modernization Project (LAMP). This includes the replacement of the traditional Cockroft-Walton injection system to the newer radiofrequency quadrupole (RFQ) standard. LANSCE accelerates both H- and H+ beams and therefore requires an unconventional application for RFQ systems. A new facility could consider using an independent RFQ for each beam species. However, with the tight space of the LANSCE injector facility, it would prove difficult to instrument. Our initial studies have shown that a single RFQ could be used. The negatively- and positively-charged direct current (DC) beams are shaped, bunched, and accelerated out of phase to each other, with very little interaction. This would work for all possible H+ beam gates and most H- Beam gates. However, a challenge arises with the Weapons Neutron Research (WNR) beam structure that requires the acceleration of bunched beams at higher charge density per pulse. The Long Bunch Enable Gate (LBEG) used for the Lujan center is the best example of a standard injector beam gate. The beam gate, or Macro-Pulse (MP), is 625-us long, separated by at least 8.3 ms. A chopper is used to dice the MP into 1750 mini-Pulses (mP), which are 290-ns wide. After chopping, the MP contains 100,000 micro-Pulses (uP), which are generated by the linac acceleration structure modulated at 201.25 MHz; that is, the micro-Pulses are separated 5 ns apart from each other. The H+ beam structure will be very similar once a chopper is added to its transport. However, the Multi-Pulse Enable Gate (MPEG) used for WNR is significantly different in structure. In this case, the mP is chopped to be only 35-ns wide. This width is then rotated into a single 201.25 MHz RF bucket using the Low Frequency Buncher (LFB). This is proving difficult for the RFQ design in the LAMP upgrade. We began investigating the amount of current sent to WNR for two reasons. Firstly, we wanted to find a solution to avoid using the Low Frequency Buncher to simplify the LAMP RFQ design. It is simple to inject and accelerate a 35 mA DC beam in the LAMP RFQ (this is done in numerous accelerator facilities). However, injecting a short bunch with a larger current (once compressed to 5 ns to meet the RFQ frequency) may be difficult. Second, we have a technique called PSR2WNR in which we do not employ the Low Frequency Buncher, but rather accumulate 5 LBEG uP (5 ns) in the PSR and deliver the accumulated beam to WNR every 1.8 us. As a result, we could provide to WNR with five accumulated LBEG uPs every shot. The goal here is to create a rapid kicker with a frequency response of 555 kHz. DARHT-II and other accelerator facilities have constructed kickers of this type for other uses, and our engineers consider this technology as feasible.

43 PARTICLE ACCELERATORS↗

Space-Time Quantum Information from the Entangled States of Magnetic Molecule (STI Product)

This collaborative project combines synthesis, measurement, and theory by three faculty members at the Eddleman Quantum Institute of UC Irvine to effectively investigate the quantum properties of molecules in the space, time, and frequency domains. Through synthetic chemistry, molecules are tailored for their magnetic and coherent properties. By combining femtosecond (fs) terahertz (THz) light and a continuous wave (cw) THz laser with a low temperature scanning tunneling microscope (STM), quantum phenomena are probed with simultaneous femtosecond temporal and atomic-scale spatial resolution. In particular, the invention of the quantum superposition microscope (QSM) advances quantum sensing for enhanced spectroscopy and imaging capabilities. Coupling theory to the experimental efforts offers a deeper understanding and predictive power for the molecular systems. The phenomena of superposition, entanglement, and coherence is central to quantum information science and can be realized in qubit states. Many systems can be modeled by a double-well potential in which two levels are formed in the two lowest energy states interacting with the environment and external radiation. In focusing on molecules as two-level systems, the underlying expectation is that their tunable composition and structure allows an effective parameter space to optimize their use as qubits for quantum sensing and computing. The THz radiation induces the superposition between the two states, appearing as temporal oscillations that damp in amplitude. Enhanced spectroscopy and imaging in the time and frequency domains is achieved through the extreme sensitivity of the frequency and damping of coherence of two-level systems to its environment. A single hydrogen molecule trapped in the STM tunneling gap experiences a double-well potential and absorption of THz femtosecond pulses of light creates the superposition of its two levels, appearing as damped oscillations in the light induced direct current (DC). The oscillation frequency depends sensitively on the electric field distribution of the copper nitride (Cu 2 N) surface, through the Stark effect, and associated with the different charge distributions at the copper and nitrogen sites and in between. This QSM can resolve variation in the surface electric field with 0.02 nanometer resolution. In addition, the single hydrogen molecule entaes with nearby hydrogen molecules as seen in the avoided level crossings of energy (oscillation frequency) versus the voltage across the tunneling gap. Thus, the first application of the QSM senses and images the surface electric field at the atomic scale. Results from this project advance fundamental understanding of quantum phenomena, develop novel synthesis, measurement, and theory, provide the knowledge foundation for molecule-based qubits and sensing that enable the development of the QSM and emergent technologies. This project trained researchers in quantum information science, extended knowledge in classrooms, and outreached to the community.

47 OTHER INSTRUMENTATION↗

Recommended Actions to Improve Adapter Safety

With the rapid advancement and acceleration in the electric vehicle (EV) industry within the United States, major automakers and EV charging companies are increasingly adopting the North American Charging Standard (NACS) connector style, now officially known as J3400. This shift is expected to enhance charging infrastructure, providing a better customer experience by making it easier for all EV drivers to access a wider network of direct-current (DC) fast chargers (DCFCs). However, the adoption of the J3400 standard presents challenges for many EVs already on the roads and some currently coming off production lines that are equipped with the Combined Charging System (CCS) connector, which this report will refer to as the North American standard, CCS1. These vehicles will need adapters to use new or existing J3400 infrastructure. During this transition, several issues have emerged. Firstly, there is a need to standardize the new connector type to ensure it is interoperable, safe, and reliable. Second, existing CCS EV drivers need a way to access the J3400 network, which will require electric vehicle supply equipment (EVSE) or sites with both connector types, driver-provided adapters to physically convert from CCS to J3400, or EVSE with retained adapters designed for use with the EVSE. Third, adapter standards will need to be written to specify how they will be designed and what evaluations will be needed to ensure safe and reliable performance. To address these challenges, adapters that support different types of charging connectors will be essential. These adapters will play a crucial role in supporting the transition and ensuring continued service for legacy EVs with CCS inlets as the J3400 standard becomes the predominant one in the United States. Consequently, the National Charging Experience (ChargeX) Consortium has investigated and performed a teardown analysis on the different adapter versions on the market. The aim is to create a failure mode and effects analysis (FMEA) on what are expected to be the most common adapter types used in this transition. In order to support this work, we executed an FMEA exercise with the main goal of identifying gaps in the existing adapters' performance and conformance to the most common safety requirements of high-power and high-voltage devices. This effort focused on adapters provided by the driver, as these may present the highest safety and reliability risks. The recommendations made here apply to both retained and driver-provided adapters.

25 ENERGY STORAGE↗

Advanced Diagnosis and Accelerated Testing of Balance of System Components for Utility Scale PV Installations: October 1, 2022-September 30, 2024

A study of the durability of PV Balance of System components was performed. Specifically, wire cable jackets and cable connectors were examined within the direct current (DC) PV Power Transmission Chain (PTC). Degraded and failed samples have been obtained from utility PV installations to provide feedback on the degradation modes and the related damage-enabling considerations in today's PV systems. An industry interface group (including system owners, system inspectors, component manufacturers, and test labs) was used to help identify and obtain field-failed samples, for feedback (including samples and experimental design), and to facilitate the subsequent dissemination of the results of this study. Samples were empirically studied using accelerated stress testing with steady-state conditions (cable jackets) in addition to combined-accelerated stress testing (cable jackets, connectors and uncapped connectors). Steady-state accelerated testing has been performed using at least one applied stressor (e.g. UV light) to aid understanding of jacket durability relative to its application. Component- and material-focused failure analysis was conducted to develop an understanding and advise the PV industry. In-depth characterization will be applied selectively to field- and artificially aged-samples, to gain scientific understanding of the structural, chemical, electrical, mechanical, and thermal properties enabling degradation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Communications Reliability for Vehicle Grid Integration

Electric Vehicles (EVs) adoption rate has been steadily increasing in the US leading to a growing number of charging stations including faster DC (Direct Current) chargers and slower Level 1 and Level 2 AC (Alternating Current) chargers. This increase in demand for electricity is further exacerbated by recent developments in Artificial Intelligence (AI) technology, advanced manufacturing, and digitization. These factors will require electric utilities to upgrade their infrastructure to keep up with the increasing electrical demand (especially during peak hours). An easy way to counteract the need for these upgrades is to shift a major chunk of active charge sessions (durations where there is energy transfer from charger to EV's propulsion battery) to off-peak hours thereby flattening the load curve and making the infrastructure more resilient. This concept is known as Smart Charge Management (SCM). EV owners also benefit from SCM since it lowers their charging costs and consequently their transportation costs by prioritizing charging during off-peak hours. SCM takes advantage of EV's capability to act as a controllable load or DER (Distributed Energy Resource). This report summarizes the reliability analysis performed on the communication required for two of these SCM use-cases. This analysis only focuses on SCM strategies for unidirectional charging (energy transfer from EVSE to EV or V1G) and not bidirectional charging.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Towaoc Housing Solar Initiative

The Towaoc Housing Solar initiative was implemented to install net-metered solar generation systems on twenty-three Tribal buildings in Towoac, CO on the Ute Mountain Ute Reservation. The project was funded 80% by Department of Energy and 20% by the Ute Mountain Ute Tribe. The project and grant are authorized by Ute Mountain Ute Tribal Council Resolution 2020-116. The systems were designed to cumulatively generate 160 direct current (DC) kilowatts on average, translating to 222,585 kilowatt hours per year. The average cost for the generation was calculated at $\$$3.34/watt with a return on investment period anticipated at 22 years for a simple payback of all costs, 11 years for the Tribe’s investment at 50% cost-share. The systems should last for 30 years. The primary goals of the project for the Tribe were identified as the reduction of electricity costs for the twenty three Tribal buildings of the Housing Authority (comprising 22 rental homes and a small apartment building with 11 units) and the reduction of carbon pollution through the transition of energy sources used in the buildings.

14 SOLAR ENERGY↗

Standardizing Performance Metrics for Building-Level Electrical Distribution Systems

Building-level electrical distribution systems comprise a myriad of current-carrying equipment, conversion devices, and protection devices that deliver power from the utility or local distributed energy resources to end-use building loads. Electric power has traditionally been generated, transmitted, and distributed in alternating current (AC). However, the last decade has seen a significant increase in the integration of native direct current (DC) equipment that has elevated the importance of DC distribution systems. Numerous studies have comparatively examined the performance of various electrical distribution systems in buildings but have failed to achieve uniform conclusions, primarily because of a lack of consistent and analogous performance evaluation methods. This paper aims to fill this gap by providing a standard set of metrics and measurement boundaries to consistently evaluate the performance of AC, DC, or hybrid AC/DC electrical distribution systems. The efficacy of the proposed approach is evaluated on a representative medium-sized commercial office building model with AC distribution and an equivalent hybrid AC/DC and DC distribution model, wherein the AC distribution model is concluded to be the most efficient. The simulation results show variation in computed metrics with different selected boundaries that verify the effectiveness of the proposed approach in ensuring consistent computation of the performance of building-level electrical distribution systems. This paper provides an initial set of guidelines for building energy system stakeholders to adopt appropriate solutions, thus leading to more efficient energy systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Micro-inverter assembly for use in a photovoltaic system and method of making same

A micro-inverter assembly for use in a photovoltaic system includes a housing, a direct current (DC)-to-alternating current (AC) micro-inverter disposed within the housing, and a DC connector electrically coupled to the DC-to-AC micro-inverter. The DC connector is positioned within a recess formed in a bottom surface of the housing such that at least one electrical contact of the DC connector is accessible from outside the housing. According to alternative embodiments, the DC connector comprises a plug-and-play connector constructed for one of a rotational engagement and a translational engagement with a DC connector of a photovoltaic (PV) panel.

Cioffi, Philip Michael↗

Power converter circuitry for photovoltaic devices

Power converter circuitry includes a direct current (DC) input comprising a first DC input node and a second DC input node, an alternating current (AC) output comprising a first AC output node coupled to the first DC input node and a second AC output node, a first boost switch coupled between the second DC input node and a boost intermediate node, a second boost switch coupled between the boost intermediate node and a common node, a boost inductor coupled between the boost intermediate node and the first DC input node, a link capacitor coupled between the second DC input node and the common node, a first half-bridge switch coupled between the second DC input node and a half-bridge intermediate node, a second half-bridge switch coupled between the half-bridge intermediate node and the common node, and a half-bridge inductor coupled between the half-bridge intermediate node and the second AC output node.

Ayyanar, Rajapandian↗

Optoelectronic memristor devices including one or more solid electrolytes with electrically controllable optical properties

An optoelectronic memristor includes a first electrode, a second electrode, and a solid electrolyte in between that is in electrical communication with the first electrode and the second electrode. The solid electrolyte has an electronic conductivity of about 10 −10 Siemens/cm to about 10 −4 Siemens/cm at room temperature. The first electrode, and optionally the second electrode, can be optically transparent at a specific wavelength and/or a wavelength range. A direct current (DC) voltage source is employed to apply an electric field across the solid electrolyte, which induces a spatial redistribution of ionic defects in the solid electrolyte. In turn, this causes a change in electrical resistance of the solid electrolyte. The application of the electric field can also cause a change in an optical property of the solid electrolyte at the specific wavelength, and/or at the wavelength range (or a portion thereof).

Defferriere, Thomas↗

Integration of microinverter with photovoltaic module

Various technologies for integrating a microinverter with a photovoltaic module are disclosed. An alternating current photovoltaic (ACPV) module includes a photovoltaic module having a frame and a junction box including a direct current (DC) output connector, and a microinverter having a housing coupled to the frame and a DC input connector electrically mated with the DC output connector of the photovoltaic module.

Gilchrist, Phil↗

Three-phase differential mode converter

A system for charging a battery includes three sub-modules, each receiving a respective phase of a three-phase alternating current (AC) signal. The three sub-modules cooperate to transform the respective phases of the three-phase AC signal to a direct current (DC) signal by passing the respective phases of the three-phase AC signal through a respective semiconductor device configured to discontinuously modulate the respective phase of the three-phase AC signal to convert it to a DC signal provided to the battery to charge the battery.

Mazumder, Sudip K.↗

Magnetic cores with high reluctance differences in flux paths

Embodiment of the present invention includes a magnetic structure and a magnetic structure used in a direct current (DC) to DC energy converter. The magnetic structure has an E-core and a plate, with the plate positioned in contact or in near contact with the post surfaces of the E-core. The E-core has a base, a no-winding leg, a transformer leg, and an inductor leg. The no-winding leg, the transformer leg, and the inductor leg are perpendicular and magnetically in contact with the base. The plate is a flat slab with lateral dimensions generally larger than its thickness. The plate has a plate nose that overlaps a top no-winding leg surface of the no-winding leg with a no-winding gap area to form a no-winding gap with a no-winding gap reluctance. The plate also has a plate end that overlaps a top inductor leg surface of the inductor leg with an inductor gap area to form an inductor gap with an inductor gap reluctance. In some embodiments, e.g., where the duty cycle is less than 50 percent, the inductor gap reluctance will be designed to be less than the no-winding gap reluctance. In these cases, the majority of the magnetic flux that passes through the transformer leg will return through the inductor leg, instead of through the no-winding leg. The inductor and no-winding gap reluctances can he adjusted, so that the electromotive force applied to a charge passing through the inductor will partially cancel the electromotive force applied by the transformer secondary. The gap reluctance ratio can be defined, so that the difference in secondary and inductor electromotive forces is equal to the output voltage defined by an optimal no-ripple duty cycle. In this way no changing current is required through the inductor to create a dI/dt inductive voltage drop across the output inductor. Zero output current ripple is achieved.Various embodiments of the plate, plate shape, and no-winding leg are disclosed. These embodiments allow achieving a high ratio of no-winding gap reluctance to inductor gap reluctance, for practical, affordable magnetic material structures and aspect ratios. A high gap reluctance ratio enables zero output current ripple for the high transformer turns ratios that are needed to achieve high input to output voltage ratios. The embodiments therefore allow achieving low output current ripple for 48 V or higher input voltages, 1 V or lower output voltages, and high output currents.

Yao, Yuan↗