Search NASA⌕ Search

SEARCH · Search NASA

Results for “Doppler spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

High-resolution continuous-wave coherent anti-Stokes Raman spectroscopy in a supersonic jet

High-resolution CW coherent anti-Stokes Raman spectra of the nu1 Q branch of methane in an underexpanded supersonic jet were obtained at temperatures as low as 31.5 K and pressures as low as 2 torr. The experimental spectra were well fitted by the calculated theoretical spectra, including transit-time broadening. A temperature of 31.5 K produced the best fit to the data, and the transit-time broadening was comparable to the residual Doppler broadening of about 100 MHz. The supersonic jet provides a convenient method of obtaining molecular cooling at relatively high density, and the ease of construction and the wide range of temperatures and densities available make it a useful tool for high resolution molecular spectroscopy.

Gustafson, E. K.↗

A spectroscopic and photometric study of FK Comae in 1989

Results of an observational campaign, coordinated between visual photometry, optical spectroscopy, and UV spectroscopy, to elucidate the characteristics of FK Comae are presented. The photometry showed complicated but systematic behavior. Photospheric absorption lines were distorted by a Doppler-shifted bump caused by dark starspots resulting in small apparent radial velocity variations. No radial velocity variations characteristic of orbital motion were seen to a level of 3 km/s. Broad emission in H-alpha was modulated at the photospheric rotational amplitude, implying an origin no farther from the rotational axis than 1 stellar radius. The strengths of Ca II lines are modulated in phase with H-alpha but do not have velocity-modulated wings like H-alpha.

Huenemoerder, David P.↗

Infrared spectra of van de Waals complexes of importance in planetary atmospheres

It has been suggested that (CO2)2 and Ar-CO2 are important constituents of the planetary atmospheres of Venus and Mars. Recent results on the laboratory spectroscopy of CO2 containing van der Waals complexes which may be of use in the modeling of the spectra of planetary atmospheres are presented. Sub-Doppler infrared spectra were obtained for (CO2)2, (CO2)3, and rare-gas-CO2 complexes in the vicinity of the CO2 Fermi diad at 2.7 micrometers using a color-center-laser optothermal spectrometer. From the spectroscopic constants the geometries of the complexes have been determined and van der Waals vibrational frequencies have been estimated. The equilibrium configurations are C2h, C3h, and C2v, for (CO2)2, (CO2)3, and the rare-gas-CO2 complexes, respectively. Most of the homogeneous linewidths for the revibrational transitions range from 0.5 to 22 MHz, indicating that predissociation is as much as four orders of magnitude faster than radiative processes for vibrational relaxation in these complexes.

Fraser, G. T.↗

Monitoring for neuroprotection. New technologies for the new millennium

Monitoring for neuroprotection, like surgery, has placed on emphasis on minimal or non-invasiveness. Monitoring of parameters that truly reflect the degree of injury to the nervous system is another goal. Thus, two themes for the coming decade in neuromonitoring will be: (1) less-invasive monitoring; and (2) parameters that more closely reflect the etiological factors in ischemic or other neuroinjury. In this paper, we review neuromonitoring techniques and devices that can be used readily in the operating room or intensive care unit setting. Those that require transport of the patient to a special facility (e.g., for computed tomography or magnetic resonance imaging/spectroscopy) and those that have been in standard practice for neuromonitoring (e.g., electrophysiological monitoring--EEG, evoked potentials) are not considered. The two techniques considered in detail are (1) continuous multiparameter local brain tissue monitoring with microprobes, and (2) non-invasive continuous local brain tissue oxygenation monitoring by near infrared spectroscopy. Both techniques have been cleared by the Food and Drug Administration (FDA) for clinical use. The rationale for their use, the nature of the devices, and clinical results to date are reviewed. It is expected that both techniques will gain wide acceptance during the coming decade; further advances in neuromonitoring that can be expected further into the twenty-first century are also discussed.

Review↗

Some aspects of remote atmospheric sensing by laser radar

An analysis has been made of some aspects of atmospheric sensing by laser radar spectroscopy. A discussion of the laser radar equation is presented which leads to methods for obtaining atmospheric information by spectroscopic means. Calculations are presented which investigate the potential of Doppler, Raman and differential absorption techniques. It is concluded that atmospheric measurements based upon Doppler and Raman approaches are restricted to qualitative studies at the present time primarily because of the limitations imposed by existing laser sources and detectors. It is probable that these limitations will be removed in the near future and it is recommended that exploratory experiments be continued. The differential absorption method for obtaining the spatial distribution of atmospheric gases is well developed for such gases as water vapor and oxygen where the basic laser frequency lies close to the center of the particular absorption line. Further investigation is recommended in the field of laser frequency shifting. Additional information is also required on the shape of the absorption line, particular in the region where the line reflects both pressure and Doppler broadening.

Schotland, R. M.↗

The convective noise floor for the spectroscopic detection of low mass companions to solar type stars

The threshold mass for the unambiguous spectroscopic detection of low mass companions to solar type stars is defined here as the time when the maximum acceleration in the stellar radial velocity due to the Doppler reflex of the companion exceeds the apparent acceleration produced by changes in convection. An apparent acceleration of 11 m/s/yr in integrated sunlight was measured using near infrared Fourier transform spectroscopy. This drift in the apparent solar velocity is attributed to a lessening in the magnetic inhibition of granular convection as solar minimum approaches. The threshold mass for spectroscopic detection of companions to a one solar mass star is estimated at below one Jupiter mass.

Deming, D.↗

Diode laser saturation spectroscopy of NH3

Saturation of molecular transitions using a tuneable diode laser was demonstrated for the first time using a standing-wave cavity configuration with an f/8 beam focussed at the sample. Observed saturation effects in NH3 transitions near 888/cm include sub-Doppler (Lamb-dip) resonances at line center.

Jennings, D. E.↗

Differential absorption lidar measurements of atmospheric water vapor using a pseudonoise code modulated AlGaAs laser

Lidar measurements using pseudonoise code modulated AlGaAs lasers are reported. Horizontal path lidar measurements were made at night to terrestrial targets at ranges of 5 and 13 km with 35 mW of average power and integration times of one second. Cloud and aerosol lidar measurements were made to thin cirrus clouds at 13 km altitude with Rayleigh (molecular) backscatter evident up to 9 km. Average transmitter power was 35 mW and measurement integration time was 20 minutes. An AlGaAs laser was used to characterize spectral properties of water vapor absorption lines at 811.617, 816.024, and 815.769 nm in a multipass absorption cell using derivative spectroscopy techniques. Frequency locking of an AlGaAs laser to a water vapor absorption line was achieved with a laser center frequency stability measured to better than one-fifth of the water vapor Doppler linewidth over several minutes. Differential absorption lidar measurements of atmospheric water vapor were made in both integrated path and range-resolved modes using an externally modulated AlGaAs laser. Mean water vapor number density was estimated from both integrated path and range-resolved DIAL measurements and agreed with measured humidity values to within 6.5 percent and 20 percent, respectively. Error sources were identified and their effects on estimates of water vapor number density calculated.

Rall, Jonathan A. R.↗

Indium Single-Ion Frequency Standard

A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

Nagourney, Warren↗

Tunable diode laser optogalvanic spectroscopy of molecules

The laser optogalvanic (LOG) technique for studying molecular spectra has been extended for the first time to the infrared wavelength region. Portions of the NH3 nu-2 band at 9.5 microns and the NO2 nu-3 band at 6.2 microns have been recorded at Doppler-limited resolution using CW tunable diode lasers to probe dc electrical discharges in pure NH3 and an NO2/He gas mixture. Using adjustable electrode positions and an orthogonal geometry between the probe laser and the discharge axis, two contributions to the optogalvanic signal are identified: one which corresponds to an increase in discharge impedance and is seen only for irradiation of the negative glow region; and a second which corresponds to a decrease in discharge impedance and is seen for irradiation of all other discharge regions.

Webster, C. R.↗

An Intense Slit Discharge Source of Jet-Cooled Molecular Ions and Radicals (T(sub rot) less than 30 K)

A novel pulsed, slit supersonic discharge source is described for generating intense jet-cooled densities of radicals (greater than 10(exp 12)/cu cm) and molecular ions (greater than 10(exp 10)/cu cm) under long absorption path (80 cm), supersonically cooled conditions. The design confines the discharge region upstream of the supersonic expansion orifice to achieve efficient rotational cooling down to 30 K or less. The collisionally collimated velocity distribution in the slit discharge geometry yields sub-Doppler spectral linewidths, which for open-shell radicals reveals spin-rotation splittings and broadening due to nuclear hyperfine structure. Application of the slit source for high-resolution, direct IR laser absorption spectroscopy in discharges is demonstrated on species such as OH, H3O(+) and N2H(+).

Anderson, David T.↗

X-ray line widths and coronal heating

Preliminary results of spectroscopy and imaging of a solar active region and flare plasma in soft X-ray emission lines are presented. Observed X-ray line widths in a nonflaring active region are broader than the Doppler width corresponding to the local electron temperature. An analysis of 41 soft X-ray flares within a single active region reveals a preference for flares to occur at locations that already show enhanced X-ray emission and to favor magnetic complexity over high gradient. However, flares do not appear to be directly responsible for the heating and X-ray production of the active regions.

Acton, L. W.↗

Stable isotope laser spectroscopy

Recent advances in semiconductor laser technology have produced a reliable lightweight device ideally suited for a spacecraft high resolution molecular spectrometer. Lead-salt tunable diode lasers (TDL) emit in several spectral modes, each with a very narrow linewidth of -0.0003/cm. This spectral resolution is much narrower than typical Doppler broadened molecular linewidths in the mid-IR range. Thus it is possible to detect individual rotational lines within the vibrational band and measure their intensity, which can be used to determine gas concentration. The narrow spectral lines of any impurity gas tend to lie between the narrow lines of the gas of interest. This represents a major advantage over the accepted gas chromatograph mass spectrometer (GCMS) technique for measuring gas concentrations and isotope ratios. The careful and extensive gas purification procedures required to remove impurities for reliable GCMS measurements will not be required for an IR laser gas analysis. The infrared laser gas analysis technique is being developed to measure stable isotopic ratios of gases such as CO2, CH4, N2O, and NH3. This will eventually lead to development of instruments capable of in situ istopic measurements on planets such as Mars. The carbon (C-12, C-13) isotope ratio is indicative of the type of carbon fixation mechanisms (e.g., photosynthesis, respiration) in operation on a planet, while the nitrogen (N-14, N-15) isotope ratio can probably be used to date nitrogen-bearing Martian samples. The absorbance ratio of two adjacent lines of CO2 in the 2300/cm (4.3 micron) region of the spectrum was measured. The precision of the measurement is presently better than 1 percent and significant improvement is anticipated as rapid sweep-integration techniques and computer controlled data acquistion capabilities are incorporated.

Becker, J. F.↗

Passive remote sensing of stratospheric and mesospheric winds

A passive infrared sensor for remote sounding of the wind field in the stratosphere and mesosphere from near earth orbital spacecraft is described. The sensor utilizes gas correlation spectroscopy and electrooptic phase-modulation techniques to measure winds in the 20-120 km altitude range, temperature, and atmospheric species concentrations. The operation of the sensor is examined. The sensitivity of the sensor is small Doppler shifts in an observed spectrum and the performance of the instrument were evaluated using laboratory simulation and numerical modeling. The data reveal that the sensor's wind measurements should have an accuracy better than 5 m/s and a spatial resolution of 5 km vertical by 150 km horizontal.

Mccleese, D. J.↗

Combustion Zone Characterization of GO2/GH2 Rocket Using Laser-Induced Fluorescence of OH

A series of studies were undertaken to measure various parameters such as velocity, species concentration, and temperature downstream of a shear coaxial injector in an optically accessible uni-element rocket chamber. Techniques applied include: laser Doppler velocimetry (LDV) for velocity; laser light scattering (LLS) for flow visualization and estimating mixture fraction and density; laser induced fluorescence (LIF) of hydroxyl radials (OH) to determine the characteristics and extent of the reaction zone; and Raman spectroscopy to measure major species concentration and temperature.

Moser, M. D.↗

Advanced Non-Intrusive Instrumentation for Propulsion Engines

Changes in engine technology such as higher temperatures, higher tip speeds, new metal/composite/ceramic materials together with radical changes in design philosophy will require amongst other prerequisites the ability to measure and to monitor key internal gas and structural characteristics. The symposium papers presented non-intrusive measurement and analysis technologies in the following categories: Laser Point Measurements (11); Absorption and Infrared Techniques (4); Paints - Surface Sensors (6); Laser Induced Fluorescence (6); Mechanical (7); Films (5); Laser Planar Measurement (9); and a Keynote Address.

Propulsion↗

WISE J233237.05-505643.5: A Double-Peaked Broad-Lined AGN with Spiral-Shaped Radio Morphology

We present radio continuum mapping, optical imaging and spectroscopy of the newly discovered double-peaked broad-lined AGN WISE J233237.05-505643.5 at redshift z = 0.3447. This source exhibits an FR-I and FR-II hybrid-morphology, characterized by bright core, jet, and Doppler-boosted lobe structures in ATCA continuum maps at 1.5, 5.6, and 9 GHz. Unlike most FR-II objects, W2332-5056 is hosted by a disk-like galaxy. The core has a projected 5" linear radio feature that is perpendicular to the curved primary jet, hinting at unusual and complex activity within the inner 25 kpc. The multi-epoch optical-near-IR photometric measurements indicate significant variability over a 3-20 year baseline from the AGN component. Gemini-South optical data shows an unusual double-peaked emission-line features: the centroids of the broad-lined components of H-alpha and H-beta are blueshifted with respect to the narrow lines and host galaxy by approximately 3800 km/s. We examine possible cases which involve single or double supermassive black holes in the system, and discuss required future investigations to disentangle the mystery nature of this system.

galaxies: individual↗

High-Resolution Spectroscopy of the Lunar Sodium Exosphere

We have applied high-resolution Fabry-Perot spectroscopy to the study of the lunar sodium exosphere for the study of exospheric effective temperature and velocity variations. Observing from the National Solar Observatory McMath-Pierce Telescope, we used a dual-etalon Fabry-Perot spectrometer with a resolving power of 180,000 to measure line widths and Doppler shifts of the sodium D2 (5889.95 Å) emission line. Our field of view was 360 km, and measurements were made in equatorial and polar regions from 500 km to 3500 km off the limb. Data were obtained from full moon to 3 days following full moon (waning phase) in March 2009. Measured Doppler line widths within 1100 km of the sunlit east and south lunar limbs for observations between 5 and 40 deg lunar phase imply effective temperatures ranging between 3260 +/- 190 and 1000 +/- 135 K. Preliminary line center analysis indicates velocity displacements between different locations off the lunar limb ranging between 100 and 600 m/s from the lunar rest velocity with a precision of +/-20 to +/-50 m/s depending on brightness. Based on the success of these exploratory observations, an extensive program has been initiated that is expected to constrain lunar atmospheric and surface-process modeling and help quantify source and escape mechanisms.

Lunar↗