Search NASA⌕ Search

SEARCH · Search NASA

Results for “Dryer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Drying of strawberries with airborne ultrasound and other integrated dehydration mechanisms

This article presents a comprehensive investigation into the drying of strawberries using multiple dehydration methods with an emphasis on energy efficiency and sustainability. Initially, an airborne ultrasonic transducer with a frequency of 21 kHz was employed in batch operations to examine the effects of controlling parameters, including applied power, distance from the transducer plate, sample thickness, and sample holder type. The Energy Ratio, defined as the ratio of thermal energy required to evaporate moisture to ultrasonic energy, was observed to reach up to 2.2, particularly during the initial stages of drying. Subsequently, the Smart Dryer integrated airborne ultrasound (US) dehydration, slot jet reattachment (SJR) nozzle convective drying, infrared (IR) drying, and their combinations, enabling a systematic exploration of various drying conditions on the drying time and quality of strawberries. The integration of airborne US with SJR nozzles and IR drying demonstrates a promising approach for optimizing drying processes. This method not only preserves the quality of dried strawberries but also improves the energy factor to 0.88, reducing drying time by 89% compared with other conditions. Key quality attributes of the dried strawberries, such as color and water activity, were evaluated to understand the influence of each drying method. The findings highlight the potential of these integrated drying techniques as sustainable solutions for efficient and high-quality strawberry dehydration.

42 ENGINEERING↗

PINCH POINT ANALYSIS OF GAS COOLERS IN TRANSCRITICAL R1336mzz(Z) HIGH-TEMPERATURE HEAT PUMPS

The majority of high-temperature heat pumps (HTHPs) operate subcritical vapor compression cycles, where the maximum sink temperature is limited by the critical temperature of refrigerants. In HTHPs with a sink temperature of ≥ 150°C, transcritical cycles overcome this limitation by rejecting heat in the supercritical regions of refrigerant. Supercritical refrigerants in gas coolers have a large temperature glide and substantial nonlinear variation in specific heat capacity vs. temperature. Closely matching the refrigerant glide temperature and the heat sink temperature profile greatly impacts the heat transfer characteristic of gas coolers and the overall performance of HTHPs. This study conducts a pinch point analysis for the gas cooling process of supercritical R1336mzz(Z) in HTHPs. A finite volume element model of a supercritical R1336mzz(Z) counterflow gas cooler is built and solved. This study evaluates the influences of operating conditions, including inlet and outlet of coolants, refrigerant evaporation temperature and superheat degree, pinch temperature difference, and heat rejection pressure, on the performance of HTHPs. The optimal discharge pressures in gas coolers are proposed for industrial spray dryers in providing drying air at 170°C−210°C. The results of the present study help design gas coolers in transcritical R1336mzz(Z) HTHPs.

Wang, Pengtao↗

Herbaceous Feedstock 2019 State of Technology Report

The U.S. Department of Energy (DOE) promotes the production of advanced liquid transportation fuels from lignocellulosic biomass by funding fundamental and applied research that advances the State of Technology (SOT). As part of its involvement with this mission, Idaho National Laboratory (INL) completes an annual SOT report for biomass feedstock logistics. This report summarizes supply system impacts of Bioenergy Technologies Office (BETO)-funded research and development efforts at INL and elsewhere (such as the High-Tonnage Feedstock Logistics projects (Webb et al. 2013a, Webb et al. 2013b, Webb et al. 2013c, Webb and Sokhansanj 2014, Sokhansanj et al. 2014)) that lead to improvements in feedstock supply systems. These include improvements to and observed performance of innovative harvest and collection methods, storage technologies, transportation and handling approaches, and advanced preprocessing technologies. Biomass quality and variability, and the interface between feedstock quality and conversion performance are key drivers in addition to delivered feedstock cost. In this report, we estimate the benefits of R&D improvements to individual supply system unit operations and present the status of feedstock logistics technology development for converting biomass into biofuels. These analyses are supported by experimental data where possible and help to align the SOT relative to the cost goals defined in the Multi-Year Program Plan. The 2019 Herbaceous SOT incorporates several technology changes in feedstock preprocessing and introduces opportunities from the integrated landscape management (ILM) strategy and increased grower participation to reduce biomass access costs, while maintaining or improving grower profitability. During FY18 uneven flow from the horizontal bale grinder was identified as a significant issue limiting preprocessing system throughput. Based on FSL-funded research at INL, the 2019 Herbaceous SOT replaces the horizontal bale grinder used in the first stage size reduction with a bale processor. The improved uniformity of biomass flow entering the PDU eliminated slugging flow from the first stage size reduction and improved the throughput of downstream operations. In order to achieve moisture reduction through frictional heating during grinding (which allowed elimination of the costly rotary drum dryer in previous SOTs), the second stage grinder was changed from a rotary shear, which does not remove moisture, back to a hammer mill. Finally, the 2019 Herbaceous SOT introduces modified three-pass and two-pass corn stover supply curves derived from the BT16 resource assessment, based on FY19 modeling results (WBS 4.2.1.20) quantifying economic benefits of ILM in the supply area, together with modeling results (WBS 1.2.1.5) identifying ILM strategies to increase grower participation. The 2019 Herbaceous SOT report documents the current modeled cost of an herbaceous feedstock supply system from harvest to the pretreatment reactor throat for hydrocarbon fuel production via biochemical conversion, based on equipment and processes now available or potentially available in the near term. The modeled cost also considers both the required quality and the availability of the biomass resources. The 2019 Herbaceous SOT predicts a modeled delivered feedstock cost of $81.37 /dry ton (2016$); this is a $2.30/dry ton (2016$) decrease from the 2018 Herbaceous SOT. Technology improvements that contributed to this modeled cost reduction include reduced cost for the new preprocessing design and quantification of the opportunities of the integrated landscape management (ILM) strategy and an increased grower participation rate to reduce the grower payment portion of biomass access costs, while maintaining or improving grower profitability. A greenhouse gas emissions (GHG) assessment was completed by Argonne National Laboratory using the 2019 Greenhouse Gases, Regulated Emissions, and Energy use in Transportation model, estimating an increase of 14.89 kg CO2e/ton from the 2018 SOT (69.27 kg CO2e/ton in 2018 to 84.16 kg CO2e/ton in 2019). The increase of energy consumption during preprocessing along with higher transportation distance to access low cost biomass from further distance contributed to the increase of GHG emissions in the 2019 Herbaceous SOT. The reason for the increased transportation distances was the cost tradeoff of going farther from the biorefinery to access the cheaper ILM-derived counties (the cheaper price outweighed the cost of increased supply radius).

09 BIOMASS FUELS↗

Filtration Performance Results: Sierra Peaks Material No. 4

Sandia National Laboratories (SNL) assessed the filtration performance of materials from Sierra Peaks to identify alternatives which may perform similarly to materials used in FDA-approved N95 respirators. This work is meant to characterize the aerosol performance of materials to give Sierra Peaks information for them to determine if they elect to submit masks made using these materials for follow-on N95 certification testing at an accredited facility. The R&D testbed used is a large-scale filtration system designed to test commercial filter boxes. System modifications were performed to simulate, where possible, parameters defined by the National Institute for Occupational Safety and Health (NIOSH) for certification of filter materials for N95 respirators (NIOSH 2019). The system is a pull-through design. Air enters through a Laminar Flow Element (LFE) and the volumetric flow is measured based on the pressure drop across the LFE. Pressure is measured via a Pressure Transducer (PT). The air then passes through a High Efficiency Particulate Air (HEPA) filter to purge the air of ambient airborne particulates. Test aerosol is injected into the flow shortly after and mixing is induced via a coarse mesh. The airflow is allowed to fully develop prior to arriving at the test section. The aerosol then passes through the test material mounted in a box in the test section. Pressure drop across the test article is measured and aerosol sampling probes measure the aerosol concentrations upstream and downstream of the sample. The air passes through a second HEPA filter prior to being exhausted to ambient by a blower. A Topas aerosol generator is used to produce the test aerosol from Sodium Chloride (NaC1) dissolved in deionized (DI) water. Generated aerosol passes through a heated mixing chamber and a desiccant dryer to produce nanosized solid-state particulates. A dilution loop allows for the aerosol concentration to be regulated. The aerosol sampling probes upstream and downstream of the test section are aligned with the flow path. These are ducted directly to the aerosol sizing and counting instruments. A Laser Aerosol Spectrometer (LAS) was used for data collection in the original configuration of the system and was also used for initial testing in this project. Because the lower measurement range for the LAS is 90 nanometers (nm), the LAS was switched out for a more complicated Scanning Mobility Particle Sizer (SMPS) spectrometer system. The SMPS is comprised of an Electrostatic Classifier (EC), Differential Mobility Analyzer (DMA), and a Condensation Particle Counter (CPC). This enabled data collection at 75 nm, the particle size called out in the NIOSH guidelines.

36 MATERIALS SCIENCE↗

Tracer gas test in Net-Zero Energy Residential Test Facility

The Net-Zero Energy Residential Test Facility (NZERTF) at NIST was built in 2012 to support the development and adoption of cost-effective net-zero energy designs, technologies, and construction methods. It is two-story, and has four bedrooms, three bathrooms, and an open living room, dining room, and kitchen space. The NZERTF also has a basement and attic, both located within the conditioned space because the thermal and air-moisture barriers encompass the basement walls and attic roof. Transfer grilles link the living spaces to these two zones. The central heating and cooling system includes an air-toair heat pump, which delivers air to the basement, first and second floors. The heat pump has a cooling capacity of 7.6 kW and a heating capacity of 7.8 kW. The indoor unit is in the basement and ductwork runs along the basement ceiling. A balanced heat recovery ventilator (HRV) is installed in the basement and has its own dedicated ductwork. The HRV supplies 47 L/s of outdoor air to the house, with supplies on the first floor (in the kitchen/dining area) and in each of the three second-floor bedrooms. Air from the first-floor bathroom and both second-floor bathrooms is returned to the HRV before being exhausted, though the HRV was turned off during the tests. The house also has a range hood exhaust and a clothes dryer exhaust, both of which were turned off for the tests. The temperature of the house was measured and the operation of the space conditioning system, including its recirculating air distribution fan, were controlled by a commercially available thermostat.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of Long Fiber Filled Materials for Fused Filament Fabrication (FFF) (Phase 2)

ORNL worked with 3D Platform to develop new hardware and systems for their largest product, a medium format pellet system known as the WorkCenter 500. 3D Platform provided an Alpha version of the system for ORNL to begin development and systems integration. ORNL focused efforts on integrating a new dryer, safety enclosure, extruder, and build table for improved operation of the system.

36 MATERIALS SCIENCE↗

Preheating of Cold, High Moisture Particulate Biomaterials to Reduce Drying Time

Forest Concepts led a two-year project to reduce fossil fuel consumption and improve the energy efficiency of dryers through the application of radio frequency (RF) energy impartation to preheat cold-wet bulk particulate biomass materials. A comprehensive biomass heating and drying mathematical model was developed that enables simulation of drying systems for biomass as well as most other bulk porous particulate materials. Experimental and modeling results conclude that energy consumption for both RF preheating and hot-air preheating are essentially equal for cold, high-moisture feedstocks that are above fiber saturation and therefore not economically beneficial for those conditions. Further results suggest that RF heating may have a direct energy consumption benefit in the late stages of drying and in case of preheating biomass that has a moisture content below fiber saturation. This work was funded in part by the US Department of Energy under contact DE-EE0009130.

09 BIOMASS FUELS↗

Managing Army Plug Load Equipment Energy Use: Vending Machines

Vending machines consume the most energy of individual plug load devices common to Army buildings. As a group, they rank fourth in total electricity consumption, behind only clothes dryers, laptop computers, and telecom loads. Upgrading 80% of the estimated 22,000 refrigerated vending machines on Army installations to the latest ENERGY STAR ® performance and optimizing their efficiency settings could save 31 million kWh and $2 million per year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

FORGE: Summer Internship Experience

The presentation summarizes my summer internship experience with the Fluids Group at Fermilab. During the internship, I learned about the maintenance and operation of water pumps and other equipment that support important facility systems. I worked alongside fluids technicians and gained hands-on experience with maintaining machinery, installing pipes, refilling water, cleaning RF cavities, and observing new water-pump construction for PIP-II. My projects included repairing an air dryer, learning how heat exchangers cool low-conductivity water, and cleaning the copper cooling rings used in RF cavities. Overall, this experience helped me better understand the work processes of technicians and the importance of practical technical knowledge for engineers.

Uribe, Anthony [Unlisted, US, IL]↗

Fluorescent bioaerosol particle concentrations measured by the DU WIBS during the AGINSGP field experiment

Real-time, immersion mode ambient fluorescent bioaerosol concentrations were measured at ARM’s Southern Great Plains (SGP) site during the AGINSGP field experiment using a Wideband Integrated Bioaerosol Sensor (DMT Inc.; WIBS-4A). The WIBS-4A is an optical particle counter that also measures single particle fluorescence in three channels, along with particle asymmetry. Particles are grouped into different types depending on which channels they fluoresce in. The instrument was located in the guest instrument facility (GIF) and measured fluorescent particle concentrations from April 7th to April 29th. Data presented here are the concentrations for each particle type, binned in 5 minute increments. Air was drawn into the GIF through custom aluminum stack inlets (6” inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8” or 1/4" copper lines, depending on sample flow of the instrument. Particles were dried using a silica diffusion dryer prior to analysis.

54 ENVIRONMENTAL SCIENCES↗

Lunar Orbiter photo-subsystem mechanisms

Lunar Orbiter photo subsystem mechanisms, discussing film transport, vacuum and mechanical clamps, focal plane shutter, processor-dryer and optical mechanical scan

Bradley, G.↗

Evidence of a diffuse magnetopause boundary.

Observational evidence is presented to show that the magnetosphere-magnetopause boundary was diffuse during the Pioneer 8 magnetopause traversal on Dec. 14 and 15, 1967. This boundary was characterized by proton fluxes of significantly lower intensity than those observed in the magnetosheath. In addition, the angles of flow associated with the fluxes at the boundary were more diverse than those observed in the magnetosheath. Proton energy spectra are presented to indicate the change in the spectral shape at the boundary. The observational evidence is consistent with calculations by Axford and Dryer of a viscous magnetopause boundary layer, which is a function of an anomalous nonclassical kinematic viscosity. The observational evidence presented for the diffuse magnetosphere boundary may also be consistent with Dungey's model reconnection of magnetic field lines and an open magnetosphere.

Intriligator, D. S.↗

Distant Bow Shock Observations by Explorer 33

Locations, orientations and magnetic field changes are given for 135 bow shock crossings at distances downstream from earth between 84 and 117 earth radii. The shock locations are dependent on the spacecraft trajectory and agree with locations calculated for the hypersonic analogue for a Mach number of 3.8. The shock normal vectors have been calculated using magnetic coplanarity. The average normal vectors have a greater inclination by approximately 17 + or - 5 deg from the symmetry axis than the Dryer and Heckman shock orientations for a 3.8 Mach number. Over a range of downstream distances from 60 to 115 earth radii, the median magnetic field magnitude jump across the shock changes from 1.90 to 1.70 times.

Mihalov, J. D.↗

Solar concentrator/absorber

Collector/energy converter, consisting of dual-slope optical concentrator and counterflow thermal energy absorber, is attached to multiaxis support structure. Efficient over wide range of illumination levels, device may be used to generate high temperature steam, serve as solar powered dryer, or power absorption cycle cooler.

Von Tiesenhausen, G. F.↗

Development of megasonic cleaning for silicon wafers

A cleaning and drying system for processing at least 2500 three in. diameter wafers per hour was developed with a reduction in process cost. The system consists of an ammonia hydrogen peroxide bath in which both surfaces of 3/32 in. spaced, ion implanted wafers are cleaned in quartz carriers moved on a belt past two pairs of megasonic transducers. The wafers are dried in the novel room temperature, high velocity air dryer in the same carriers used for annealing. A new laser scanner was used effectively to monitor the cleaning ability on a sampling basis.

Mayer, A.↗

An atmospheric exposure chamber for small animals

The purpose of this project was to design a long-term environmental exposure chamber for small animals. This chamber is capable of producing hypoxic, normoxic and hyperoxic atmospheres which are closely regulated. The chamber, which is of the recycling type, is fashioned after clear plastic germ-free isolators. Oxygen concentration is set and controlled by a paramagnetic O2 analyzer and a 3-way solenoid valve. In this way either O2 or N2 may be provided to the system by way of negative O2 feedback. Relative humidity is maintained at 40-50 percent by a refrigeration type dryer. Carbon dioxide is absorbed by indicating soda lime. A diaphragm pump continuously circulates chamber gas at a high enough flow rate to prevent buildup of CO2 and humidity. This chamber has been used for numerous studies which involve prolonged exposure of small animals to various O2 concentrations.

Glaser, R. M.↗

Power-Factor Controllers: How Safe?

Potential safety problems with power-factor controllers (PFC's) evaluated. Based on study of PFCs in use with appliances, report recommends measures to prevent consumers from misapplying these energy saving devices. Device used on such appliances as refrigerators, sewing machines, pumps, hair dryers, and food processors. When misused, they fail to save energy and may cause damage.

Long, K.↗

Polymeric Electrolytic Hygrometer For Harsh Environments

Design of polymeric electrolytic hygrometer improved to meet need for reliable measurements of relative humidity in harsh environments of pulpmills and papermills. Redesigned sensor head features shorter, more-rigidly-held sensing element, less vulnerable than previous version to swell and loss of electrical contact. Useful for control of batch dryers in food and pharmaceutical industries.

Lawson, Daniel D.↗