The track-length extension fitting algorithm for energy measurement of interacting particles in liquid argon TPCs and its performance with ProtoDUNE-SP data

This paper introduces a novel track-length extension fitting algorithm for measuring the kinetic energies of inelastically interacting particles in liquid argon time projection chambers (LArTPCs). The algorithm finds the most probable offset in track length for a track-like object by comparing the measured ionization density as a function of position with a theoretical prediction of the energy loss as a function of the energy, including models of electron recombination and detector response. The algorithm can be used to measure the energies of particles that interact before they stop, such as charged pions that are absorbed by argon nuclei. The algorithm's energy measurement resolutions and fractional biases are presented as functions of particle kinetic energy and number of track hits using samples of stopping secondary charged pions in data collected by the ProtoDUNE-SP detector, and also in a detailed simulation. Additional studies describe the impact of the dE/dx model on energy measurement performance. The method described in this paper to characterize the energy measurement performance can be repeated in any LArTPC experiment using stopping secondary charged pions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Italian Summer Students Program at Fermilab and other US Laboratories: 40 years of education in particle physics and technology

Since 1983 the Italian groups collaborating with Fermilab (US) have been running a 2-month summer training program for Master students. While in the first year the program involved only 4 physics students, in the following years it was extended to engineering students. Many students have extended their collaboration with Fermilab with their Master Thesis and PhD. The program has involved almost 600 Italian students from more than 20 Italian universities. Each intern is supervised by a Fermilab Mentor responsible for the training program. Training programs spanned from Tevatron, CMS, Muon (g-2), Mu2e and SBN and DUNE design and data analysis, development of particle detectors, design of electronic and accelerator components, development of infrastructures and software for tera-data handling, quantum computing and research on superconductive elements and accelerating cavities. In 2015 the University of Pisa included the program within its own educational programs. Summer Students are enrolled at the University of Pisa for the duration of the internship and at the end of the internship they write summary reports on their achievements. After positive evaluation by a University of Pisa Examining Board, interns are acknowledged 6 ECTS credits for their Diploma Supplement. In the years 2020 and 2021 the program was canceled due to the sanitary emergency but in 2022 it was restarted and allowed a cohort of 21 students in 2022, and a cohort of 27 students in 2023 to be trained for nine weeks at Fermilab. We are now organizing the 2024 program.

Barzi, Emanuela↗

Resistive Coatings for High-performance, Low-background MCPs Operating Across Broad Temperature Ranges and at Cryogenic Temperatures

Microchannel plate with improved thermo-electric properties are a high risk, high payoff development undertaken by a consortium of effort that links the Argonne National Lab, the Space-Science Lab at UC Berkeley and the small businesses (Incom Inc.) that will commercialize the advanced technology in open MCPs and LAPPDs. This development will satisfy the needs for new instrumentation for homeland security (non-proliferation) sensors to screen vehicles and cargo for Special Nuclear Materials (SNMs) and scientific detectors for astrophysics, electron microscopy, time-of-flight mass spectrometry, molecular and atomic collision studies, and fluorescence imaging applications in biotechnology and medical imaging products including positron emission tomography (PET scanning).

99 GENERAL AND MISCELLANEOUS↗

Search for inelastic boosted dark matter with the ICARUS detector at the Gran Sasso Underground National Laboratory

We present the result of a search for inelastic boosted dark matter using the data corresponding to an exposure of 0.13 kton · year , collected by the ICARUS T-600 detector during its 2012–2013 operational period at the INFN Gran Sasso Underground National Laboratory. The benchmark boosted dark matter model features a multiparticle dark sector with a U ( 1 ) ′ gauge boson, the dark photon. The kinetic mixing of the dark photon with the Standard Model photon allows for a portal between the dark sector and the visible sector. The inelastic boosted dark matter interaction occurs when a dark matter particle inelastically scatters with an electron in the ICARUS detector, producing an outgoing, heavier dark sector state which subsequently decays back down to the dark matter particle, emitting a dark photon. The dark photon subsequently couples to a Standard Model photon through kinetic mixing. The Standard Model photon then converts to an electron-positron pair in the detector. This interaction process provides a distinct experimental signature that consists of a recoil electron from the primary interaction and an associated electron-positron pair from the secondary vertex. After analyzing 4,134 triggered events, the search results in zero observed events. Exclusion limits are set in the dark photon mass and coupling ( m X , ε ) parameter space for several selected optimal boosted dark matter mass sets and cover previously unexplored parameter space. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Testing of a Line Driver With Configurable Pre-Emphasis on Lossy Transmission Lines

Rare-event physics experiments such as the Deep Underground Neutrino Experiment (DUNE) or the next Enriched Xenon Observatory (nEXO) experiment search for rare, low-energy events, detected by sensitive detectors immersed in a cryogenic noble liquid (e.g., liquid argon or xenon). Readout electronics used within such detectors must consume minimal power while operating reliably in cryogenic environments. Furthermore, in the case of nEXO, maximizing the radiopurity of the environment is vital to minimize background noise, thus placing strict limits on the volume of dielectric materials, leading to high-loss data cables spanning distances up to 12 m. Such cables cause high attenuation and intersymbol interference (ISI), resulting in a high bit-error rate (BER). These issues were addressed by developing an integrated line driver with configurable pre-emphasis in a 65-nm CMOS process. The pre-emphasis parameters can be programmed to minimize BER for specific cables and data rates under power constraints. Here, the driver was tested at both room and cryogenic temperatures. In both cases, the output BER was found to be strongly correlated with the pre-emphasis settings. Furthermore, analysis and simulation showed that adapting the pre-emphasis settings based on the incoming bit sequence can further improve performance with minimal changes to the current solution.

47 OTHER INSTRUMENTATION↗

Precise test of lepton flavour universality in W -boson decays into muons and electrons in pp collisions at $\sqrt{s}$ =13 TeV with the ATLAS detector

The ratio of branching ratios of the $W$ boson to muons and electrons, $R^{μ/e}_{W}$ = $\mathcal{B}$($W$ → $μν$)/$\mathcal{B}$($W$ → $eν$), has been measured using 140 fb -1 of pp collision data at $\sqrt{s}$ = 13 TeV collected with the ATLAS detector at the LHC, probing the universality of lepton couplings. The ratio is obtained from measurements of the $t\overline{t}$ production cross section in the $ee$, $eμ$ and $μμ$ dilepton final states. To reduce systematic uncertainties, it is normalised by the square root of the corresponding ratio $R^{μμ/ee}_{Z}$ for the Z boson measured in inclusive $Z$ → $ee$ and $Z$ → $μμ$ events. By using the precise value of $R^{μμ/ee}_{Z}$ determined from $e^+$ $e^-$ colliders, the ratio $R^{μ/e}_{W}$ is determined to be $R^{μ/e}_{W}$ = 0.9995 ± 0.0022 (stat) ± 0.0036 (syst) ± 0.0014 (ext). The three uncertainties correspond to data statistics, experimental systematics and the external measurement of $R^{μμ/ee}_{Z}$, giving a total uncertainty of 0.0045, and confirming the Standard Model assumption of lepton flavour universality in $W$ boson decays at the 0.5% level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Single particle – MC-ICP-MS for isotopic analysis of uranium particles

Single particle – multi-collector – inductively coupled plasma – mass spectrometry (SP-MC-ICP-MS) was employed to measure a suspension of 1 µm U3O8 particles (∼1.3 pg total U/particle) to determine their individual isotopic compositions of 234U/238U, 235U/238U, and 236U/238U. The effects of different detector combinations for 235U and 238U, including secondary electron multipliers (SEM) and Faraday detectors (1011 and 1013 Ω amplifiers), were explored for accuracy and precision optimization on the observed 235U/238U. The minor isotopic ratios (i.e., 234U/238U and 236U/238U) were analyzed such that the 234U and 236U were monitored on SEM detectors and the 238U was monitored on a Faraday (1011 Ω) detector. Various integration times (5, 10, 25, and 50 ms) were investigated in all detector configurations to gain a better understanding of their impact on sensitivity, accuracy, and precision. For 235U/238U ratios of 1 µm U3O8 particles, a dual Faraday detector measurement with 1011 Ω was the optimal choice; measurement of 1021 particles yielded an average 235U/238U ratio of 0.00170 (14), a −1.8% relative difference (% RD) from the reference value. The minor isotopic compositions were determined to be 0.0000070 (14) and 0.0000758 (48) for the 234U/238U and 236U/238U, respectively. These measurements correspond to <8% and <1% RD from their reference value for the 234U/238U and 236U/238U, respectively. SP-MC-ICP-MS was also able to provide insight into measurement sensitivity. In these individual particles, merely 15 and 165 atto-grams (ag) of 234U and 236U were present (calculated). Initial limits of detection for SP-MC-ICP-MS were determined to be ∼1.0 ag (when measured via SEM detectors). This valuable approach is applicable to areas including nuclear forensics, nuclear safeguards, and geochemical analysis, which require high-precision measurements of uranium within micron-sized particles.

Manard, Benjamin [ORNL] (ORCID:0000000207400627)↗

MPGD Trackers in the ePIC Detector at the EIC

The future Electron-Ion Collider (EIC) at Brookhaven National Laboratory will collide polarized electrons with polarized proton/ions. The electron ? Proton / Ion Collider (ePIC) Experiment is the EIC general-purpose detector aiming at delivering the full physics program of the EIC. This unique environment imposes stringent requirements on the tracking system needed for the measurement of the scattered electron and charged particles produced in the collisions at the EIC. The central tracker of the ePIC detector has silicon layers for tracking and vertexing based on MAPS technology, which are complemented by large Micro-Pattern Gaseous Detector (MPGD) trackers in the barrel and in both the electron and hadron end cap regions. The MPGD layers provide fast timing (10-20 ns) and additional hit points (150 µm) for pattern recognition during track finding. Two MPGD technologies are used in ePIC central trackers: cylindrical Micromegas for the barrel inner tracker and planar thin-gap GEM-µRWELL hybrid detector for the barrel outer tracker and the end cap disks. In this talk, we will introduce these two technologies in the context of ePIC and we will discuss the ongoing R&D efforts to address the requirements. Finally, we will discuss the plans and timeline for the production and testing and commissioning of the MPGD trackers for the installation in the ePIC detector.

Gnanvo, Kondo↗

Revealing Phase Heterogeneity in Vertically Aligned Nanocomposites via Plan-View Electron Energy Loss Spectroscopy

Hydrogen utilization in clean energy technologies is challenged by limited storage and transport within materials, owing to the complex hydrogen kinetics at interfaces [1]. Understanding these interfacial mechanisms at the nanoscale is crucial for developing improved materials for hydrogen applications, particularly proton-conducting fuel cells (PCFCs). Vertically aligned nanocomposites (VANs) grown by pulsed laser deposition (PLD) offer a unique platform for investigating the interfacial effects on hydrogen transport due to their well-defined interfaces parallel to the direction of charge transport [2-4]. To investigate hydrogen transport, the two phases within the VANs were chosen as BaZr 0.9 Y 0.1 O 3-x (BZY), a known proton conductor, and Pr 0.1 Ce 0.9 O 2-x (PCO), a mixed ionic-electronic conductor [5]. This PCO-BZY VANs architecture allows the investigation of how the interface between a proton conductor and a mixed conductor influences hydrogen transport. However, because of the small size of hydrogen, it is difficult to discern the nature of its interactions with interfaces from bulk measurements at the macroscale, thus necessitating nanoscale measurements [6]. Electron energy loss spectroscopy (EELS) allows for nanometer-resolution probing of the local atomic structure and chemistry at the BZY/PCO interface. In this study, plan-view analysis of PCO-BZY VANs films was employed to characterize the structure and phase distribution of the VANs and investigate the interface between the nanostructures. The films were imaged using scanning electron microscopy (SEM) in the Hitachi S-4800 SEM, collecting secondary electron images using mixed upper and lower detectors. Then, plan-view transmission electron microscopy (TEM) and scanning transmission electron microscopy (STEM) EELS were employed using a JEOL ARM300 microscope operated at 300kV with a Gatan K3 GIF Continuum detector to study the distribution of the BZY and PCO phases through the film. As a result, spectrum images were acquired at a dispersion of 0.18eV per channel and denoised afterward by principal component analysis (PCA) method.

Griffin, Elizabeth [Northwestern University, Evans↗

Study of deeply virtual Compton scattering at the future electron-ion collider

This study presents the impact of future measurements of deeply virtual Compton scattering (DVCS) with the ePIC detector at the electron-ion collider (EIC), currently under construction at Brookhaven National Laboratory. The considered process is sensitive to generalized parton distributions (GPDs), the understanding of which is a cornerstone of the EIC physics program. Our study marks a milestone in the preparation of DVCS measurements at EIC and provides a reference point for future analyses. In addition to presenting distributions of basic kinematic variables obtained with the latest ePIC design and simulation software, we examine the impact of future measurements on the understanding of nucleon tomography and DVCS Compton form factors, which are directly linked to GPDs. We also assess the impact of radiative corrections and background contribution arising from exclusive π 0 production.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optimization of the light detection system of the ICARUS detector

The Short Baseline Neutrino (SBN) Program at Fermilab is designed to investigate short-baseline neutrino oscillations and test the hypothesis of sterile neutrinos, motivated by several experimental anomalies observed over the past decades. Within this program, the ICARUS experiment plays a key role. It employs the world’s largest Liquid Argon Time Projection Chamber (LArTPC) and serves as the farthest and most sensitive SBN detector for studying muon and electron neutrino oscillations. A crucial subsystem of the ICARUS detector is the Light Detection System (LDS), which captures the prompt scintillation light produced by neutrino interactions in the 600-ton active liquid Argon volume. This system provides precise timing information that is essential for event reconstruction, the trigger system, and cosmic background rejection. The LDS is composed of 360 Hamamatsu R5912-MOD 8-inch photomultiplier tubes (PMTs), operating under cryogenic conditions ($\sim 87 \ K$) inside the detector’s cryostats. During the detector’s operation at FNAL, a degradation in PMT gain has been observed, attributed to aging under low-temperature conditions. In collaboration with ICARUS teams from INFN Pavia and Catania, I developed an experimental setup to study the temperature-dependent behavior of the PMTs, performing gain measurements both at room temperature and down to $-70°C$ using a climatic chamber at INFN Catania. The results indicate that while the PMTs maintain stable gain at room temperature, a significant and permanent gain reduction occurs at low temperatures. Although $-70°C$ is still warmer than liquid Argon temperatures, the findings clearly demonstrate a gain-dependent performance degradation. The thesis also discusses mitigation strategies implemented in the ICARUS detector to address this issue and presents a simplified model to describe and simulate the observed behavior.

Saia, Clara [Catania U.] (ORCID:0009000464102417)↗

Electromagnetic Shower Reconstruction and Identification in FASER's Emulsion Detector for LHC Forward Neutrino Measurements

We present methods for electromagnetic shower reconstruction and identification in the FASERnu emulsion detector using 100 GeV and 200 GeV electron test-beam data from the CERN SPS H4 beamline. The reconstruction employs a clustering-based algorithm without energy-dependent tuning to determine shower axes. A multi-level identification chain comprising track pre-selection, a cut-based selection, and a BDT classifier achieves combined background rejection rates of 99.99% (100 GeV) and 99.94% (200 GeV). The method reaches total reconstruction and identification efficiencies of 58.9% (100 GeV) and 70.8% (200 GeV) evaluated from simulated samples. Energy reconstruction using the total number of reconstructed segments as the calorimetric estimator yields relative biases of +0.6% (100 GeV) and -0.8% (200 GeV), with resolutions of 25.4% and 22.6%, respectively. Systematic uncertainties on the energy reconstruction are dominated by variations in emulsion film detection efficiency, contributing (+10.9%/-8.2%) at 100 GeV and (+10.3%/-6.9%) at 200 GeV. The methodology provides a validated framework for electron neutrino identification with the FASERnu detector at the LHC.

Mammen Abraham, Roshan [UC, Irvine]↗

Deployment of POLARBEAR-2b

POLARBEAR-2b (PB-2b) is the second receiver in the Simons Array, a cosmic microwave background (CMB) polarization experiment. The Simons Array uses dichroic polarization sensitive lenslet-coupled sinuous antennas and transition-edge sensor (TES) bolometers made of superconducting films. These bolometers are read out with frequency multiplexing electronics. PB-2b contains ~7500 detectors in two bands at 90 and 150 GHz with arcminute resolution. The polarization of these detectors is modulated by a cryogenic continuously rotating half-wave plate. PB-2b was installed on its telescope in 2022 in the Atacama Desert at an altitude of 5.2 km. This paper will detail initial readout commissioning, test of a new loopgain monitoring method, and focusing the optics. Work is ongoing to commission the remaining ambient temperature readout electronics, measure detector time constants, and observe with the cryogenic half-wave plate spinning.

47 OTHER INSTRUMENTATION↗

Large area position sensitive detector for thermal neutrons

Large area thermal neutron detectors are applied in many fields including industrial imaging, nuclear safeguarding, neutron scattering, and fundamental science. Historically, these detectors were based on 3 He gas proportional counters despite the limitations of 3 He detectors such as high cost, limited supply, non-uniform spatial resolution, and depth of absorption problems. Two alternatives to 3 He detectors are 6 Li-loaded glass scintillators, and powdered ZnS(Ag) scintillators mixed with 6LiF neutron converters. The 6 LiF/ZnS(Ag) scintillator has advantages over 6 Li glass as it is less expensive and can be produced in larger areas, although its self-absorption presents a problem. In this work, we developed a large area thermal neutron detector based on 6 LiF/ZnS(Ag) scintillator coupled with wavelength shifting fibers. The detector uses resistive charge divider-based position encoding. We further modified and improved the method by 2D segmentation of the detector using modular multichannel readout electronics. This segmentation approach allows for a combination of large detector area, improved spatial resolution, and increased count rate. Furthermore, spatial resolution can be variable across the detector area by adjusting the segment size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic Design and Thermal Analysis of EIC Central Detector (ePIC) Solenoid Magnet (MARCO)

The Electron Ion Collider (EIC) physics program utilizes a 2.0 T superconducting magnet at the heart of its ePIC detector system. This approximately 3.5 m long and 2.84 m diameter warm bore magnet has a 20 tons cold mass which is conduction-cooled using liquid helium at 4.5 K. A closed loop active thermosiphon system is chosen to facilitate the cooling and to maintain a minimum of 2 K temperature margin on the peak operating temperature (4.7 K) of the superconductor. Here, this paper presents the cryogenic design of the cooling system and the thermal analysis of the solenoid. A Computational fluid dynamics (CFD) model was developed to quantify the performance of the two–phase closed thermosiphon system and predict the temperature gradient on the cold mass.

Gopinath, Sandesh [Thomas Jefferson National Accel↗

High‐speed 4‐dimensional scanning transmission electron microscopy using compressive sensing techniques

Abstract Here we show that compressive sensing allows 4‐dimensional (4‐D) STEM data to be obtained and accurately reconstructed with both high‐speed and reduced electron fluence. The methodology needed to achieve these results compared to conventional 4‐D approaches requires only that a random subset of probe locations is acquired from the typical regular scanning grid, which immediately generates both higher speed and the lower fluence experimentally. We also consider downsampling of the detector, showing that oversampling is inherent within convergent beam electron diffraction (CBED) patterns and that detector downsampling does not reduce precision but allows faster experimental data acquisition. Analysis of an experimental atomic resolution yttrium silicide dataset shows that it is possible to recover over 25 dB peak signal‐to‐noise ratio in the recovered phase using 0.3% of the total data. Lay abstract : Four‐dimensional scanning transmission electron microscopy (4‐D STEM) is a powerful technique for characterizing complex nanoscale structures. In this method, a convergent beam electron diffraction pattern (CBED) is acquired at each probe location during the scan of the sample. This means that a 2‐dimensional signal is acquired at each 2‐D probe location, equating to a 4‐D dataset. Despite the recent development of fast direct electron detectors, some capable of 100kHz frame rates, the limiting factor for 4‐D STEM is acquisition times in the majority of cases, where cameras will typically operate on the order of 2kHz. This means that a raster scan containing 256^2 probe locations can take on the order of 30s, approximately 100‐1000 times longer than a conventional STEM imaging technique using monolithic radial detectors. As a result, 4‐D STEM acquisitions can be subject to adverse effects such as drift, beam damage, and sample contamination. Recent advances in computational imaging techniques for STEM have allowed for faster acquisition speeds by way of acquiring only a random subset of probe locations from the field of view. By doing this, the acquisition time is significantly reduced, in some cases by a factor of 10‐100 times. The acquired data is then processed to fill‐in or inpaint the missing data, taking advantage of the inherently low‐complex signals which can be linearly combined to recover the information. In this work, similar methods are demonstrated for the acquisition of 4‐D STEM data, where only a random subset of CBED patterns are acquired over the raster scan. We simulate the compressive sensing acquisition method for 4‐D STEM and present our findings for a variety of analysis techniques such as ptychography and differential phase contrast. Our results show that acquisition times can be significantly reduced on the order of 100‐300 times, therefore improving existing frame rates, as well as further reducing the electron fluence beyond just using a faster camera.

Robinson, Alex W.↗

The NEXT-100 Detector

The NEXT collaboration is dedicated to the study of double beta decays of 136 Xe using a high-pressure gas electroluminescent time projection chamber. This advanced technology combines exceptional energy resolution (≤ 1% FWHM at the Q ββ value of the neutrinoless double beta decay) and powerful topological event discrimination. Building on the achievements of the NEXT-White detector, the NEXT-100 detector started taking data at the Laboratorio Subterráneo de Canfranc (LSC) in May of 2024. Designed to operate with xenon gas at 13.5 bar, NEXT-100 consists of a time projection chamber where the energy and the spatial pattern of the ionising particles in the detector are precisely retrieved using two sensor planes (one with photo-multiplier tubes and the other with silicon photo-multipliers). The detector has been operating at stable conditions using argon and xenon gases at ~4 bar and drift fields of 74 V cm –1 and 118 V cm –1 , respectively. Alpha decays from the 222 Rn chain have been used to test and monitor the stability of the detector, showing a constant electron lifetime in the drift volume. In this paper, in addition to reporting the results of the commissioning run, we provide a detailed description of the NEXT-100 detector, describe its assembly, and present the current estimation of the radiopurity budget.

Adams, C. [Argonne National Laboratory; NVIDIA] (O↗

Rad-hard readout system for Timepix3 Hybrid Pixel Detectors

The Beam Gas Ionisation (BGI) profile monitor, located in the Proton Synchrotron (PS) and Super Proton Synchrotron (SPS) at CERN, requires a radiation-tolerant readout system to transfer data from the challenging accelerator surroundings to the back-end for processing. The system needs to control and acquire data from four Timepix3 Hybrid Pixel Detectors (HPDs) located directly inside the beam pipe, a highly radioactive environment. It must ensure reliability given limited hardware access and preserve signal integrity for the high-speed data (32 channels at 320 MHz). However, due to the unavailability of a suitable rad-hard Timepix3 readout, the Beam Instrumentation PiXeL (BIPXL) readout system was designed to meet these requirements. This system employs radiation-hardened components such as the GBTx and the FEASTMP, both developed at CERN. It will be compatible with forthcoming hybrid pixel detector initiatives in similarly harsh radiation conditions.

47 OTHER INSTRUMENTATION↗