Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTRONIC RECORDING INSTRUMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Low Noise Amplifiers for 140 Ghz Wide-Band Cryogenic Receivers

We report S-parameter and noise measurements for three different Indium Phosphide 35-nanometer-gate-length High Electron Mobility Transistor (HEMT) Low Noise Amplifier (LNA) designs operating in the frequency range centered on 140 gigahertz. When packaged in a Waveguide Rectangular-6.1 waveguide housing, the LNAs have an average measured noise figure of 3.0 decibels - 3.6 decibels over the 122-170 gigahertz band. One LNA was cooled to 20 degrees Kelvin and a record low noise temperature of 46 Kelvin, or 0.64 decibels noise figure, was measured at 152 gigahertz. These amplifiers can be used to develop receivers for instruments that operate in the 130-170 gigahertz atmospheric window, which is an important frequency band for ground-based astronomy and millimeter-wave imaging applications.

High Electron Mobility Transistors (HEMTs)↗

A Co-Investigator Proposal for the Cornell University CAPER Rocket: Cleft Accelerated Plasma Experiment Rocket

The objectives are: 1) To support the Cornell wave instruments in a study of dayside ion outflow. 2) In conjunction with the U. of Alaska ground optical data, a prime objective was to measure the topside Cusp ion spectra responsible for dayside proton aurora. If such a correlative measurement could be made, then monitoring of this cusp precipitation from the ground could be routinely achieved. The nature of Cusp ions has and will continue to provide information about dayside magnetic reconnection. 3) A third objective was to study the dayside microburst electron precipitation from the BPS/CPS population. The Scifer rocket flight showed a bursty electron population at 1000 km altitude correlated closely with pulsation ground aurora on closed field lines. The frequency of this pulsating aurora is about 1 Hz. Ground pulsation measurements have recorded dayside bursts of Pc1 waves which could very well be the source of the electrons responsible for the pulsating aurora. In support of the Caper flight, UNH provided ground induction antennas to measure the equatorial Pc1 waves that might be dumping trapped electrons from the Central Plasma Sheet population. The Caper flight was launched on the last day of the window and all the Cornell and UNH instrumentation worked perfectly. Unfortunately the rocket trajectory flew very far to the west of the ground site at Longyearbyen missing conjugacy by several hundred kilometers. This meant the intended aurora was not crossed and all the ground experiments were far from being near the foot print of the rocket ruling out correlative science. The "miss" was primarily due to a decision during the countdown by the Andoya Rocket Range to move the azimuth of the rocket to the west to avoid Norwegian fishing boats at the splash point of the first two stages, and to make matters worse, the dispersion of the fourth stage of the rocket added entirely in this direction. Although no publications have resulted from the UNH data up to this point, a joint publication with the U. of Alaska group using both the Scifer and Caper data is in preparation. The data will continue to be worked on. There is interest in the Caper data as evidence by two recent papers presented at the "Low Latitude Boundary Layer Chapman Conference" held in New Orleans, Louisiana in April 2001.

Arnoldy, Roger L.↗

A new approach to long-life noncontacting electromechanical devices

Brushless dc motors are finding increasing application in space. Likewise, with the advent of the light emitting diode, noncontacting encoders are gradually replacing sliding contact types. The direct drive concept has proved its merit and is now the preferred approach for tape recorders and low to moderate torque instrument drives. The final step in this evolution is the magnetic bearing, which now appears feasible for several applications. Where it can be applied in a totally noncontacting system, life and reliability will be a function of the electronic controls, where redundancy, derating, and quality assurance approaches virtually assure the desired lifetime and failure rate.

Devine, E. J.↗

Extraction of the muon signals recorded with the surface detector of the Pierre Auger Observatory using recurrent neural networks

The Pierre Auger Observatory, at present the largest cosmic-ray observatory ever built, is instrumented with a ground array of 1600 water-Cherenkov detectors, known as the Surface Detector (SD). The SD samples the secondary particle content (mostly photons, electrons, positrons and muons) of extensive air showers initiated by cosmic rays with energies ranging from 1017eV up to more than 1020eV. Measuring the independent contribution of the muon component to the total registered signal is crucial to enhance the capability of the Observatory to estimate the mass of the cosmic rays on an event-by-event basis. However, with the current design of the SD, it is difficult to straightforwardly separate the contributions of muons to the SD time traces from those of photons, electrons and positrons. In this paper, we present a method aimed at extracting the muon component of the time traces registered with each individual detector of the SD using Recurrent Neural Networks. We derive the performances of the method by training the neural network on simulations, in which the muon and the electromagnetic components of the traces are known. We conclude this work showing the performance of this method on experimental data of the Pierre Auger Observatory. We find that our predictions agree with the parameterizations obtained by the AGASA collaboration to describe the lateral distributions of the electromagnetic and muonic components of extensive air showers.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Doping engineering: Next step toward room temperature performance of terahertz quantum cascade lasers

We hereby offer a comprehensive analysis of various factors that could potentially enable terahertz quantum cascade lasers (THz QCLs) to achieve room temperature performance. We thoroughly examine and integrate the latest findings from recent studies in the field. Our work goes beyond a mere analysis; it represents a nuanced and comprehensive exploration of the intricate factors influencing the performance of THz QCLs. Through a comprehensive and holistic approach, we propose novel insights that significantly contribute to advancing strategies for improving the temperature performance of THz QCLs. This all-encompassing perspective allows us not only to present a synthesis of existing knowledge but also to offer a fresh and nuanced strategy to improve the temperature performance of THz QCLs. We draw new conclusions from prior works, demonstrating that the key to enhancing THz QCL temperature performance involves not only optimizing interface quality but also strategically managing doping density, its spatial distribution, and profile. This is based on our results from different structures, such as two experimentally demonstrated devices: the spit-well resonant-phonon and the two-well injector direct-phonon schemes for THz QCLs, which allow efficient isolation of the laser levels from excited and continuum states. In these schemes, the doping profile has a setback that lessens the overlap of the doped region with the active laser states. Our work stands as a valuable resource for researchers seeking to gain a deeper understanding of the evolving landscape of THz technology. Furthermore, we present a novel strategy for future endeavors, providing an enhanced framework for continued exploration in this dynamic field. This strategy should pave the way to potentially reach higher temperatures than the latest records reached for T max of THz QCLs.

47 OTHER INSTRUMENTATION↗

Far Ultraviolet Imaging from the Image Spacecraft: Wideband FUV Imaging - 2

The Far Ultraviolet Wideband Imaging Camera (WIC) complements the magnetospheric images taken by the IMAGE satellite instruments with simultaneous global maps of the terrestrial aurora. Thus, a primary requirement of WIC is to image the total intensity of the aurora in wavelength regions most representative of the aurora] source and least contaminated by dayglow, have sufficient field of view to cover the entire polar region from spacecraft apogee and have resolution that is Sufficient to resolve auroras on a scale of 1 to 2 latitude degrees, The instrument is sensitive in the spectral region from 140- 190 nm. The WIC is mounted on the rotating, IMAGE spacecraft viewing radially outward and has a field of view of 17 deg in the direction parallel to the spacecraft spin axis. Its field of view is 30 deg in the direction perpendicular to the spin axis, although only a 17 deg x 17 deg image of the Earth is recorded. The optics was an all-reflective, inverted Cassegrain Burch camera using concentric optics with a small convex primary and a large concave secondary mirror. The mirrors were coated by a special multi-layer coating, which has low reflectivity in the visible and near UV region, The detector consists of a MCP-Intensified CCD. The MCP is curved to accommodate the focal surface of the concentric optics. Tile phosphor of the image intensifier is deposited on a concave fiberoptic window, which is then Coupled to the CCD with a fiberoptic taper. The camera head operates in a fast frame transfer mode with the CCD being read approximately 30 full frames (512 by 256 pixel) per second with an exposure time of 0.033 s. The image motion (file to the satellite spin is minimal during such a short exposure. Each image is electronically distortion corrected using the look up table scheme. An offset is added to each memory address that is proportional to the image shift due to satellite rotation, and the charge signal is digitally summed in memory. On orbit, approximately 300 frames will be added to produce one WIC image in memory. The advantage of the electronic motion compensation and distortion correction is that it is extremely flexible, permitting several kinds of corrections including motions parallel and perpendicular to the predicted axis of rotation. File instrument was calibrated by applying ultraviolet light through a vacuum monochromator and measuring the absolute responsivity of the instrument. To obtain the data for the distortion look up table the camera was turned through various angles and the input angles corresponding to a pixel matrix were recorded. It was found that the spectral response peaked at 150 nm and fell off in either direction. The equivalent aperture of the camera, including mirror reflectivities and effective photocathode quantum efficiency, is about 0.04 sq cm. Thus, a 100 Rayleigh LBH aurora is expected to produce 23 equivalent counts per pixel per 10 s exposure at the peak of instrument response.

Mende, S. B.↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

Care, feeding, and use of charge-coupled device /CCD/ imagers at Palomar observatory

The paper describes the optical, mechanical, and electronic properties of the TI and RCA CCDs which have been applied to two-dimensional photometry and spectroscopy at Palomar. The drive, processing, and recording techniques are also discussed, and consideration is given to a focal conversion optical system, the Prime Focus Universal Extragalactic Instrument (PFUEI), which is used to more optimally match the Hale 5 meter plate scale. Calibration and data analysis are also examined.

Gunn, J. E.↗

Description and charging results from the RSPM

Representative satellite materials, to be flown on STP-78-2 in 1979 on the SSPM instruments, were included as part of the AFGL Rocket payload flown from White Sands Missile Range on January 21, 1978. Potentials as high as + 1100 volts on the conductor and + or - 400 volts on the insulator were recorded by the RSPM near the minimum in the electron density vs altitude profile. In addition to the charging potentials measured during ion gun operation, sample charging currents also were recorded with time resolutions near 30 milliseconds. These results demonstrate the validity of the experiment concept of the SSPM on SCATHA.

Mizera, P. F.↗

AMIA KDDM Working Group Collaborative Workshop: Enriching Electronic Health Records with Social Determinants of Health to Improve Outcomes and Health Equity

Prior research has demonstrated that social determinants of health (SDoH) are major drivers of health outcomes and contributors to widespread health inequities. It was estimated that, in the United States, SDoH could be responsible for up to 40% of all preventable deaths, significantly higher than the 10-15% for which better medical care is responsible. Public health interventions that target SDoH are instrumental for improving health outcomes and reducing long-standing health inequities. Currently, most mainstream EHR vendors have implemented SDoH screeners in their EHR systems. However, the utility of the screeners is low, rendering patient-level SDoH still widely unavailable in the structured fields. SDoH are sometimes mentioned in free-text clinical notes (e.g., social context section) where natural language processing (NLP) can be applied to extract relevant information. Contextual-level SDoH can be identified from multiple data sources, many of which are publicly available and spatiotemporally linked to EHR data. As such, there is an opportunity for the KDDM research community to create innovative solutions to draw meaningful insights by creating and using rich data with SDoH to improve health outcomes while reducing disparities. In this workshop organized by AMIA Knowledge Discovery and Data Mining Working Group (AMIA KDDM WG), we will invite world-leading experts from academia, national laboratories, and life science industry with varied backgrounds in biomedical informatics, epidemiology, data science, machine learning, natural language processing, and pediatric cardiology to discuss the best practice of capturing, standardizing, and using SDoH information in various applications aiming at improving outcomes and health equity.

He, Zhe↗

Simultaneous Observations of Traveling Convection Vortices: Ionosphere-Thermosphere Coupling

We present simultaneous observations of magnetosphere-ionosphere-thermosphere coupling over Svalbard during a traveling convection vortex (TCV) event. Various spaceborne and ground-based instruments made coordinated measurements, including magnetometers, particle detectors, an all-sky camera, European Incoherent Scatter (EISCAT) Svalbard Radar, Super Dual Auroral Radar Network (SuperDARN), and SCANning Doppler Imager (SCANDI). The instruments recorded TCVs associated with a sudden change in solar wind dynamic pressure. The data display typical features of TCVs including vortical ionospheric convection patterns seen by the ground magnetometers and SuperDARN radars and auroral precipitation near the cusp observed by the all-sky camera. Simultaneously, electron and ion temperature enhancements with corresponding density increase from soft precipitation are also observed by the EISCAT Svalbard Radar. The ground magnetometers also detected electromagnetic ion cyclotron waves at the approximate time of the TCV arrival. This implies that they were generated by a temperature anisotropy resulting from a compression on the dayside magnetosphere. SCANDI data show a divergence in thermospheric winds during the TCVs, presumably due to thermospheric heating associated with the current closure linked to a field-aligned current system generated by the TCVs. We conclude that solar wind pressure impulse-related transient phenomena can affect even the upper atmospheric dynamics via current systems established by a magnetosphere-ionosphere-thermosphere coupling process.

Kim, Hyomin↗

Patient Monitoring

In photo above, the electrocardiogram of a hospitalized patient is being transmitted by telemetry. Widely employed in space operations, telemetry is a process wherein instrument data is converted to electrical signals and sent to a receiver where the signals are reconverted to usable information. In this instance, heart readings are picked up by the electrode attached to the patient's body and delivered by wire to the small box shown, which is a telemetry transmitter. The signals are relayed wirelessly to the console in the background, which converts them to EKG data. The data is displayed visually and recorded on a printout; at the same time, it is transmitted to a central control station (upper photo) where a nurse can monitor the condition of several patients simultaneously. The Patient Monitoring System was developed by SCI Systems, Inc., Huntsville, Alabama, in conjunction with Abbott Medical Electronics, Houston, Texas. In developing the system, SCI drew upon its extensive experience as a NASA contractor. The company applied telemetry technology developed for the Saturn launch vehicle and the Apollo spacecraft; instrumentation technology developed for heart, blood pressure and sleep monitoring of astronauts aboard NASA's Skylab long duration space station; and communications technology developed for the Space Shuttle.

Source record↗

Distributed integrated instrumentation and control system

The operation and capabilities of a new integrated instrumentation and control system are described. The system will, under one main program, both acquire data from a conducted test and automatically control the test sequence. The system layout has a multiplexer front end and control-function electronics at the test area, while the system control computer, recording devices, and monitors are located remotely. The system's data, control, and communication signals are transmitted via fiber-optic lines. Diagrams are presented illustrating the control and data displays.

Hagood, Don↗

Cloud screening Coastal Zone Color Scanner images using channel 5

Clouds are removed from Coastal Zone Color Scanner (CZCS) data using channel 5. Instrumentation problems require pre-processing of channel 5 before an intelligent cloud-screening algorithm can be used. For example, at intervals of about 16 lines, the sensor records anomalously low radiances. Moreover, the calibration equation yields negative radiances when the sensor records zero counts, and pixels corrupted by electronic overshoot must also be excluded. The remaining pixels may then be used in conjunction with the procedure of Simpson and Humphrey to determine the CZCS cloud mask. These results plus in situ observations of phytoplankton pigment concentration show that pre-processing and proper cloud-screening of CZCS data are necessary for accurate satellite-derived pigment concentrations. This is especially true in the coastal margins, where pigment content is high and image distortion associated with electronic overshoot is also present. The pre-processing algorithm is critical to obtaining accurate global estimates of pigment from spacecraft data.

Eckstein, B. A.↗

Very low frequency waves stimulated by an electron accelerator in the auroral ionosphere

The sounding rocket, Polar 5, carrying a 10 keV electron accelerator in a mother-daughter configuration and other diagnostic instruments, was launched into a slightly disturbed ionosphere with weak auroral activity on February 1, 1976 from Northern Norway to study VLF wave phenomena. The rocket trajectory crossed two auroral regions: one, between 86 and 111 s flight time, and a secondary region between 230 and 330 s. The daughter, carrying the accelerator, was separated axially from the mother in a forward direction at an altitude of 90 km. The VLF experiment, carried by the mother payload, recorded both electromagnetic and electrostatic waves. The receiving antenna was an electric dipole, 0.3 m tip-to-tip, oriented 90 degrees to the rocket spin axis. The onboard particle detector recorded increased electron fluxes in the two auroral regions. A double peaked structure was observed in the fluxes of 4-5 and 12-27 keV electrons within the northern auroral form. The number density of thermal plasma varied during the flight, with maximum density within the main auroral region. To the north of this aurora a slow, steady decrease in the density was observed, with no enhancement in the region of the second aurora.

Holtet, J. A.↗

An instrument for the study of the composition of the electron component of cosmic rays

A telescope consisting of three spark chambers and two control scintillation counters has been designed and is used for investigating the composition of the cosmic ray electron component within the range of energies from 1.0 to 10.0 BeV by the EN assymetry method. The geometrical factor of the telescope is approximately 20 sq cm ster. Discharges are recorded in the chambers on a photo film. The telescope is oriented to the azimuth with an accuracy of + or - 3 deg.

Bogomolov, E. A.↗

Large scale waves in the thermosphere observed by the AE-C satellite

Atmospheric Explorer C (AE-C) data are analyzed to study wavelike perturbations in the thermosphere at an altitude of about 260 km. Four geophysical parameters are analyzed. These are nitrogen and oxygen densities, electron density and ion temperature as measured by three different instruments on board AE-C. The data are processed by normalizing them to their average values and their fluctuations are obtained by passing the normalized data through a high pass filter. These fluctuations exhibit strong periodicities that persist throughout the records, regardless of the filter cutoff frequency. The fluctuations are cross correlated by direct comparison, by comparison of their spectral content as obtained by the MEM and FFT, and by computing cross correlation functions.

Gross, S. H.↗

A portable hypergolic oxidizer vapor sensor for NASA's Space Shuttle program

The design and performance characteristics of an electrochemical NO2 sensor selected by NASA for the space shuttle program is described. The instrument consists of a sample pump, an electrochemical cell, and control and display electronics. The pump pushes the sample through the electrochemical cell where the vapors are analyzed and an output proportional to the NO2 concentration is produced. The output is displayed on a panel meter, and is also available at a recorder jack. The electrochemical cell is made up of a polypropylene chamber covered with teflon membrane faceplates. Plantinum electrodes are bonded to the faceplates, and the sensing and counter electrodes are potentiostatically controlled at -200 mV with respect to the reference electrode. The cell is filled with electrolyte, consisting of 13.5 cc of 23% solution of KOH.

Helms, W. R.↗