Search NASA⌕ Search

SEARCH · Search NASA

Results for “ELECTROPHORESIS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Bioprocessing in Microgravity: Applications of Continuous Flow Electrophoresis to Rat Anterior Pituitary Particles

In this report we describe the results of a continuous flow electrophoresis (CFE) experiment done on STS-65 in which we tested the idea that intracellular growth hormone (GH) particles contained in a cell lysate prepared from cultured rat anterior pituitary cells in microgravity might have different electrophoretic mobilities from those in a synchronous ground control cell lysate. Collectively, the results suggested that CFE processing in microgravity was better than on earth; more samples could be processed at a time (6 x) and more variant forms of GH molecules could be resolved as well. We had also hoped to carry out a pituitary cell CFE experiment, but failure of the hardware required that the actual cell electrophoresis trials be done on earth shortly after Shuttle landing. Data from these experiments showed that space-flown cells possessed a higher electrophoretic mobility than ground control cells, thereby offering evidence for the idea that exposure of cultured cells to microgravity can change their net surface charge-density especially when the cells are fed. Collectively, the results from this pituitary cell experiment document the advantage of using coupled cell culture and CFE techniques in the microgravity environment.

Hymer, W. C.↗

Quantifying clustered DNA damage induction and repair by gel electrophoresis, electronic imaging and number average length analysis

Assessing DNA damage induction, repair and consequences of such damages requires measurement of specific DNA lesions by methods that are independent of biological responses to such lesions. Lesions affecting one DNA strand (altered bases, abasic sites, single strand breaks (SSB)) as well as damages affecting both strands (clustered damages, double strand breaks) can be quantified by direct measurement of DNA using gel electrophoresis, gel imaging and number average length analysis. Damage frequencies as low as a few sites per gigabase pair (10(9)bp) can be quantified by this approach in about 50ng of non-radioactive DNA, and single molecule methods may allow such measurements in DNA from single cells. This review presents the theoretical basis, biochemical requirements and practical aspects of this approach, and shows examples of their applications in identification and quantitation of complex clustered damages.

NASA Program Biological Systems Research↗

Capillary electrophoresis-electrochemistry microfluidic system for the determination of organic peroxides

A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.

NASA Discipline Life Sciences Technologies↗

Contactless conductivity detector for microchip capillary electrophoresis

A microfabricated electrophoresis chip with an integrated contactless conductivity detection system is described. The new contactless conductivity microchip detector is based on placing two planar sensing aluminum film electrodes on the outer side of a poly(methyl methacrylate) (PMMA) microchip (without contacting the solution) and measuring the impedance of the solution in the separation channel. The contactless route obviates problems (e.g., fouling, unwanted reactions) associated with the electrode-solution contact, offers isolation of the detection system from high separation fields, does not compromise the separation efficiency, and greatly simplifies the detector fabrication. Relevant experimental variables, such as the frequency and amplitude of the applied ac voltage or the separation voltage, were examined and optimized. The detector performance was illustrated by the separation of potassium, sodium, barium, and lithium cations and the chloride, sulfate, fluoride, acetate, and phosphate anions. The response was linear (over the 20 microM-7 mM range) and reproducible (RSD = 3.4-4.9%; n = 10), with detection limits of 2.8 and 6.4 microM (for potassium and chloride, respectively). The advantages associated with the contactless conductivity detection, along with the low cost of the integrated PMMA chip/detection system, should enhance the power and scope of microfluidic analytical devices.

NASA Center JPL↗

Enhanced protein electrophoresis technique for separating human skeletal muscle myosin heavy chain isoforms

Talmadge and Roy (J. Appl. Physiol. 1993, 75, 2337-2340) previously established a sodium dodecyl sulfate - polyacrylamide gel electrophoresis (SDS-PAGE) protocol for separating all four rat skeletal muscle myosin heavy chain (MHC) isoforms (MHC I, IIa, IIx, IIb); however, when applied to human muscle, the type II MHC isoforms (Ila, IIx) are not clearly distinguished. In this brief paper we describe a modification of the SDS-PAGE protocol which yields distinct and consistent separation of all three adult human MHC isoforms (MHC I, IIa, IIx) in a minigel system. MHC specificity of each band was confirmed by Western blot using three monoclonal IgG antibodies (mAbs) immunoreactive against MHCI (mAb MHCs, Novacastra Laboratories), MHCI+IIa (mAb BF-35), and MHCIIa+IIx (mAb SC-71). Results provide a valuable SDS-PAGE minigel technique for separating MHC isoforms in human muscle without the difficult task of casting gradient gels.

NASA Center JSC↗

Analysis of water from the Space Shuttle and Mir Space Station by ion chromatography and capillary electrophoresis

Drinking water and condensate samples collected from the US Space Shuttle and the Russian Mir Space Station are analyzed routinely at the NASA-Johnson Space Center as part of an ongoing effort to verify water quality and monitor the environment of the spacecraft. Water quality monitoring is particularly important for the Mir water supply because approximately half of the water consumed is recovered from humidity condensate. Drinking water on Shuttle is derived from the fuel cells. Because there is little equipment on board the spacecraft for monitoring the water quality, samples collected by the crew are transported to Earth on Shuttle or Soyuz vehicles, and analyzed exhaustively. As part of the test battery, anions and cations are measured by ion chromatography, and carboxylates and amines by capillary electrophoresis. Analytical data from Shuttle water samples collected before and after several missions, and Mir condensate and potable recovered water samples representing several recent missions are presented and discussed. Results show that Shuttle water is of distilled quality, and Mir recovered water contains various levels of minerals imparted during the recovery processes as designed. Organic ions are rarely detected in potable water samples, but were present in humidity condensate samples.

NASA Discipline Environmental Health↗

Role of gravity in preparative electrophoresis

The fundamental formulas of electrophoresis are derived microscopically and applied to the problem of isotachophoresis. A simple physical model of the isotachophoresis front is proposed. The front motion and structure are studied in the simplified case without convection, diffusion and non-electric external forces.

Bier, M.↗

Fraction collector for electrophoresis

Rotating-tube electrophoresis apparatus employs rotating jet of eluting buffer to reduce effects of convection during separation. Designed for separation of microorganisms and biological species, system combines gravity/gradient compensating of lumen with buffer flush at fraction outlet to increase separation efficiency.

Bier, M.↗

Electrophoresis experiment for space

The Apollo 16 electrophoresis experiment was analyzed, demonstrating that the separation of the two different-size monodisperse latexes did indeed take place, but that the separation was obscured by the pronounced electroosmotic flow of the liquid medium. The results of this experiment, however, were dramatic since it is impossible to carry out a similar separation on earth. It can be stated unequivocally from this experiment that any electrophoretic separation will be enhanced under microgravity conditions. The only question is the degree of this enhancement, which can be expected to vary from one experimental technique to another. The low-electroosmotic-mobility coating (Z6040-MC) developed under this program was found to be suitable for a free-fluid electrophoretic separation such as the experiment designed for the ASTP flight. The problem with this coating, however, is that its permanency is limited because of the slow desorption of the methylcellulose from the coated surface.

Vanderhoff, J. W.↗

Development of a slicing device for Apollo-Soyuz Test Project (ASTP) electrophoresis technology experiment MA-011

The electrophoresis of six columns was accomplished on the Apollo-Soyuz test Project. After separation, these columns were frozen in orbit and were returned for ground-based analyses. One major goal of the MA-011 experiment was the assessment of the separation achieved in orbit by slicing these frozen columns. The slicing of the frozen columns required a new device. The development of that device is described.

Nerren, B. H.↗

Analysis of results of ASTP experiment in electrophoresis

The Apollo-Soyuz Test Project (ASTP) included an electrophoretic separation experiment of biological cells. The nature separation results of aldehyde-fixed rabbit, human and horse red blood cells, which were taken in the form of photographs taken at three-minute intervals, are the subject of this report. The electrophoretic separation was successful in that fractionation according to mobility did occur and was found in the sliced samples. Photographic evidence indicates that the low electroosmotic methylcellulose coating was successful in reducing the electroosmosis to a near zero value. Also, the flight film shows that the bands migrated down the column as theory would predict, producing two bands of high cell concentration separated and surrounded by regions of lower cell concentration. However, most likely some clumping of cells occurred to cause the trailing band to be larger than expected from theory. Overall, the experiment was a success in demonstrating a static electrophoresis separation under microgravity conditions with a resolution not possible on earth.

Vanderhoff, J. W.↗

High-resolution, continuous-flow electrophoresis in microgravity

Approximate expressions which will allow estimation of performance enhancement in reduced gravity and will direct optimization of the various design parameters for a continuous flow electrophoresis system was devised. Other topics discussed include: (1) temperature and velocity distribution; (2) input power limitations in reduced gravity; and (3) effect of band distortion on resolution. A comparision of resolution for terrestrial and reduced gravity operations was also discussed.

Rhodes, P. H.↗

Separation of lymphocytes by electrophoresis under terrestrial conditions and at zero gravity

Electrophoretic mobility (EPM) of human peripheral lymphocytes were examined with the following objectives: To determine differences in EPM of lymphocytes under immuno-stimulated and immuno-suppressed states. To define the conditions necessary for the separation of lymphocyte sub-populations in normal and pathological conditions; To investigate immunological active, charged chemical groups on lymphocyte surfaces; and to investigate pathophysiological mechanisms of immune responsiveness, as reflected by alterations in EPM. To evaluate the potential of lymphocyte electrophoresis as: (1) a means of monitoring the immune status of kidney transplant recipients, (2) in predicting the outcome of kidney transplants, and (3) as a method for separation of lymphocyte sub-populations, the EPM was studied for unfractionated human peripheral lymphocytes and of populations enriched with T and "B" cells from normal adults, hemodialysis patients and kidney transplant recipients.

Rubin, A. L.↗

Fluid mechanics of continuous flow electrophoresis

The following aspects of continuous flow electrophoresis were studied: (1) flow and temperature fields; (2) hydrodynamic stability; (3) separation efficiency, and (4) characteristics of wide gap chambers (the SPAR apparatus). Simplified mathematical models were developed so as to furnish a basis for understanding the phenomena and comparison of different chambers and operating conditions. Studies of the hydrodynamic stability disclosed that a wide gap chamber may be particularly sensitive to axial temperature variations which could be due to uneven heating or cooling. The mathematical model of the separation process includes effects due to the axial velocity, electro-osmotic cross flow and electrophoretic migration, all including the effects of temperature dependent properties.

Saville, D. A.↗

Fluid mechanics of continuous flow electrophoresis

The reported investigation has the objective to provide a basis for understanding the hydrodynamic characteristics of the continuous flow electrophoresis chamber and their effects on the separation process. Particular emphasis is placed on the role buoyancy plays in establishing the basic flow and affecting its stability. The flow and temperature field is discussed, taking into account mathematical models for the structure of the temperature field, models for the structure of the axial velocity field, a two-dimensional constant thermal conductivity model, the axial velocity field, a two-dimensional constant transport properties model, and one-dimensional velocity fields. Questions of hydrodynamic stability are considered, giving attention to the stability of a fully developed flow with an axial temperature gradient.

Saville, D. A.↗