Search NASA⌕ Search

SEARCH · Search NASA

Results for “ENVIRONMENTAL TEMPERATURE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Fuel-Cell Power Source Based on Onboard Rocket Propellants

The use of onboard rocket propellants (dense liquids at room temperature) in place of conventional cryogenic fuel-cell reactants (hydrogen and oxygen) eliminates the mass penalties associated with cryocooling and boil-off. The high energy content and density of the rocket propellants will also require no additional chemical processing. For a 30-day mission on the Moon that requires a continuous 100 watts of power, the reactant mass and volume would be reduced by 15 and 50 percent, respectively, even without accounting for boiloff losses. The savings increase further with increasing transit times. A high-temperature, solid oxide, electrolyte-based fuel-cell configuration, that can rapidly combine rocket propellants - both monopropellant system with hydrazine and bi-propellant systems such as monomethyl hydrazine/ unsymmetrical dimethyl hydrazine (MMH/UDMH) and nitrogen tetroxide (NTO) to produce electrical energy - overcomes the severe drawbacks of earlier attempts in 1963-1967 of using fuel reforming and aqueous media. The electrical energy available from such a fuel cell operating at 60-percent efficiency is estimated to be 1,500 Wh/kg of reactants. The proposed use of zirconia-based oxide electrolyte at 800-1,000 C will permit continuous operation, very high power densities, and substantially increased efficiency of conversion over any of the earlier attempts. The solid oxide fuel cell is also tolerant to a wide range of environmental temperatures. Such a system is built for easy refueling for exploration missions and for the ability to turn on after several years of transit. Specific examples of future missions are in-situ landers on Europa and Titan that will face extreme radiation and temperature environments, flyby missions to Saturn, and landed missions on the Moon with 14 day/night cycles.

Ganapathi, Gani↗

Dry film lubricants

The Space Age has necessitated accelerated development of many technologies which have direct application to commercial, earthbound hardware. One striking example is dry film lubrication. The stimulus for the development of dry film lubricants was provided by the unsatisfactory condition created when commercial liquid lubricants were exposed to the multiple environs of space. In the search for a satisfactory solution to lubrication in space, dry films were investigated. The dry film lubrication concept has proven most desirable for space, and a natural fallout is the potential shown by such films for consumer item application. On the acceptance that the coefficient of friction of dry films is not equivalent to that of a liquid lubricant under ideal conditions, this paper discusses how the ideal condition for liquid lubrication is rarely achieved in practical applications. Comparisons are made between the performance of dry film and liquid lubricants as a function of temperature, environmental pressure, and life. Furthermore, consideration is given to the comparative costs of liquid versus dry film lubricants to show the practicality and desirability of dry film lubrication to consumer items. Although no data on the performance of consumer items lubricated with dry films are presented, the comparisons clearly establish the potential of dry film lubricants in a competitive consumer market.

SOLID LUBRICANT↗

Thermal-difference compensation for structural members

Aluminum-thermal difference link maintains constant length of strut despite environmental temperature changes. An extension spring decreases load on the compensator drive linkage when strut is in tension, when strut is in compression, a compression spring is used. Perforated titanium outer tube exposes link to external heat.

Belew, R. R.↗

Crew/cargo and logistics module definition

The logistics requirements for the space station cargo, the initial buildup, and the 90 day resupply are presented, along with the conceptual selection for the orbiter crew accommodations and the GSS logistics system. Various module configurations are outlined; structural/mechanical, environmental, temperature, voice communication, and data bus subsystems are also reviewed. Ground operations and module prelaunch and launch operations are discussed, as well as logistics system interfaces for space shuttles and stations.

Source record↗

An emergency survival suit

A thermally insulative inflatable garment designed specifically as a lightweight low storage volume emergency suit for subzero weather survival is reported. Testing confirms that the inflatable suit design satisfies the objectives for a subject standing at rest with environmental temperatures down to -450 F if the garment is inflated with Freon.

Curtis, D. L.↗

Fatigue design procedure for the American SST prototype

For supersonic airline operations, significantly higher environmental temperature is the primary new factor affecting structural service life. Methods for incorporating the influence of temperature in detailed fatigue analyses are shown along with current test indications. Thermal effects investigated include real-time compared with short-time testing, long-time temperature exposure, and stress-temperature cycle phasing. A method is presented which allows designers and stress analyzers to check fatigue resistance of structural design details. A communicative rating system is presented which defines the relative fatigue quality of the detail so that the analyst can define cyclic-load capability of the design detail by entering constant-life charts for varying detail quality. If necessary then, this system allows the designer to determine ways to improve the fatigue quality for better life or to determine the operating stresses which will provide the required service life.

Doty, R. J.↗

Anti-motion-sickness therapy

Neither alterations in environmental temperature nor moderate intake of alcohol was found to alter susceptibility to motion sickness in subjects exposed to rotation in the Pensacola slow rotation room. Scopolamine with d-amphetamine was found to be the most effective preparation for the prevention of motion sickness under the experimental conditions of the studies reported here. Promethazine in combination with d-amphetamine was in the same range of effectiveness. Drug actions suggest that acetylcholine and norepinephrine may be involved in motion sickness.

Wood, C. D.↗

The prospects for life on Mars: A pre-Viking assessment

Mariner 9 provided a reinterpretation of several historical claims for Martian biology, and permitted an important further characterization of the environmental constraints on possible Martian organisms. Four classes of conceivable Martian organisms are identified, depending on the environmental temperature, T, and water activity, aw: Class 1, high T, high aw; Class 2, low T, high aw; Class 3, high T, low aw; and Class 4, low T, low aw. Organisms which extract their water requirements from hydrated minerals or from ice are considered possible on Mars, and the high ultraviolet flux and low oxygen partial pressure are considered to be negligible impediments to Martian biology. Large organisms are not only possible on Mars, they may be favored. The surface distribution of Martian organisms and future search strategies for life on Mars are discussed.

Sagan, C.↗

Animal exposure during burn tests

An animal exposure test system has been designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consists of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram and respiration. The ECG and respiration sensors are located in a belt placed around the torso of the subject, electrode wires forming an umbilical to a connector in the top of the compartment. A cable extends from the connector to the power supply and signal conditioning electronics. These are connected to a dual-beam oscilloscope for real time monitoring and a magnetic tape recorder having three or more channels. Endpoints observed are bradycardia, cardiac arrhythmias, changes in respiratory pattern, respiratory arrest and cardiac arrest. The ECG record also appears to be a good method of monitoring animal activity as indicated by an increase in EMG noise superimposed on the record during increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases.

Gaume, J. G.↗

The prospects for life on Mars - A pre-Viking assessment

The paper considers implications of the Mariner 9 findings for the investigation of Martian biology in the next decade, beginning with the Viking mission. Previous claims for observations of Martian biological activity are reviewed and refuted or reinterpreted. The question is raised of whether there are combinations of environmental temperature and water activity on Mars that are suitable for a conceivable Martian biology. Four possible classes of Martian organisms associated with temperature/water ecological niches in the external environment are proposed: organisms requiring high temperatures and high water activity, those inhabiting niches with low temperatures and high water activity, those inhabiting niches of high temperature and low water activity, and those which can survive under conditions of low temperature and low water activity. It is noted that organisms of the last two classes may extract water from minerals or from ice and may be of large dimensions. The possible surface distribution of Martian organisms is discussed along with future search strategies for life on Mars.

Sagan, C.↗

An unusual lightning flash at Kennedy Space Center

A lightning flash that struck the 150-meter weather tower at Kennedy Space Center was studied by several research groups using various techniques. The flash had unusually large peak currents and a stepped leader of relatively short duration. The charged regions neutralized by the three return strokes were located within a horizontal layer between heights of about 6 and 8 kilometers, where environmental temperatures were about -10 to -20 C. The charge source for the first return stroke coincided with a vertical shaft of precipitation inferred to have been graupel or hail. Charge sources for subsequent strokes were near the edge of the detectable precipitation echo. The overall channel length was about 10 kilometers. A vertically oriented intracloud discharge occurred after the three return strokes.

Uman, M. A.↗

The effect of NaCl/g/ on the oxidation of NiAl

NaCl is ingested into operating gas turbines. The effect of this salt on the high temperature surface stability properties of turbine hardware is not well understood. The involvement of gaseous NaCl in the high temperature oxidation of NiAl, a principal component in many high temperature environmental coatings, is herein examined. The results of this work indicate that gaseous NaCl present in an oxidizing atmosphere affects the formation of Al2O3 whiskers on a dense Al2O3 layer. Such whisker growth, attributed to vapor transport processes through an otherwise dense Al2O3 scale, increases the aluminum depletion of the NiAl substrate.

Smeggil, J. G.↗

Animal Exposure During Burn Tests

An animal exposure test system (AETS) was designed and fabricated for the purpose of collecting physiological and environmental (temperature) data from animal subjects exposed to combustion gases in large scale fire tests. The AETS consisted of an open wire mesh, two-compartment cage, one containing an exercise wheel for small rodents, and the other containing one rat instrumented externally for electrocardiogram (ECG) and respiration. Cage temperature is measured by a thermistor located in the upper portion of the rat compartment. Animal activity is monitored by the ECG and the records indicate an increase in EMG (electromyograph) noise super-imposed by the increased activity of the torso musculature. Examples of the recordings are presented and discussed as to their significance regarding toxicity of fire gases and specific events occurring during the test. The AETS was shown to be a useful tool in screening materials for the relative toxicity of their outgassing products during pyrolysis and combustion.

Gaume, J. G.↗