Search NASA⌕ Search

SEARCH · Search NASA

Results for “EVAPORATION RATE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Application of thermal model for pan evaporation to the hydrology of a defined medium, the sponge

A technique is presented which estimates pan evaporation from the commonly observed values of daily maximum and minimum air temperatures. These two variables are transformed to saturation vapor pressure equivalents which are used in a simple linear regression model. The model provides reasonably accurate estimates of pan evaporation rates over a large geographic area. The derived evaporation algorithm is combined with precipitation to obtain a simple moisture variable. A hypothetical medium with a capacity of 8 inches of water is initialized at 4 inches. The medium behaves like a sponge: it absorbs all incident precipitation, with runoff or drainage occurring only after it is saturated. Water is lost from this simple system through evaporation just as from a Class A pan, but at a rate proportional to its degree of saturation. The contents of the sponge is a moisture index calculated from only the maximum and minium temperatures and precipitation.

Trenchard, M. H.↗

Suggestions on the Vapor Pressure Determination of Molten Salts

The knowledge of the thermophysical properties of coolant and fuel in molten salts nuclear reactors (MSRs), such as thermal stability and vapor pressure, are of remarkable interest, particularly for simulating safe reactor operations. Molten salt reactorsMSRs use molten salt mixtures as the primary coolant and/or fuel and are expected to operate up to 800 °C. With the revival of interest in deploying MSRs, complete thermophysical and thermochemical characterization of these materials is of interest to industry, regulators, and researchers. Vapor pressure data for molten salts are scarce in the literature, both for pure salts but especially for eutectic mixtures. This report describes the effusion method, which consist of measuring the rate of escape of vapor molecules through a small orifice for the determination of the vapor pressure of compounds and may be useful on compounds such as molten salts. Thermogravimetric analysis records the mass loss as a function of time and temperature. There are two equations that can be used to relate the mass loss rate with the vapor pressure: (1) the Knudsen equation and (2) the Langmuir equation. To apply these equations, the system needs to reach a pseudo (or near) equilibrium condition. Therefore, the experimental conditions must be such that allow the condensed and the vapor/gas phases to be in equilibrium. In order to accomplish equilibrium like conditions, the sample must be in an almost-sealed cell except for a small orifice, from where the vapor escapes. In the Knudsen method vacuum is applied to eliminate the effect that the presence of other gas molecules could have on the evaporation rate of the sample. However, Langmuir alleged that in certain conditions, such as at low temperatures and/or when the vapor pressure is low, the rate of evaporation of a substance is independent of the presence of vapor around it. For that reason, some researchers, when measuring the mass loss of a substance with a predictable low vapor pressure, do not apply vacuum when using the Langmuir equation. However, they use a standard substance to parameterize the experimental setup. The use of one equation or the other will depend on the characteristics of the sample and the availability of an appropriate standard. Some important aspects related to the nature of the samples and vapor pressure measurements are described for future consideration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Interfacial Solar Evaporation by a 3D Graphene Oxide Stalk for Highly Concentrated Brine Treatment

In this study, we demonstrate a 3-dimensional graphene oxide (3D GO) stalk that operates near the capillary wicking limit to achieve an evaporation flux of 34.7 kg m -2 h -1 under 1 sun conditions (1 kW/m 2 ). This flux represents nearly a 100 times enhancement over a conventional solar evaporation pond. Interfacial solar evaporation traditionally uses 2D evaporators to vaporize water using sunlight, but their low evaporative water flux limits their practical applicability for desalination. Some recent studies using 3D evaporators demonstrate potential for more efficient water transfer, but the flux improvement has been marginal because of a low evaporation area index (EAI), which is defined as the ratio of the total evaporative surface area to the projected ground area. By using a 3D GO stalk with an ultrahigh EAI of 70, we achieved nearly a 20-fold enhancement over a 2D GO evaporator. The 3D GO stalk also exhibited additional advantages including omnidirectional sunlight utilization, a high evaporation flux under dark conditions from more efficient utilization of ambient heating, a dramatic increase of the evaporation rate by introducing wind, and scaling resistance in evaporating brines with a salt content of up to 17.5 wt %. This performance makes the 3D GO stalk well suited for the development of a low-cost, reduced footprint technology for zero liquid discharge in brine management applications.

3D evaporator↗

A model of carbon production in a cometary coma

A model of the cometary ionosphere is developed in order to account for the large population of metastable C(D-1) atoms detected via the ultraviolet spectrum of Comet West (1976 VI). Dissociative recombination of CO(plus) ions and electrons is shown to be the dominant source of carbon atoms rather than photodissociation of CO so that the derived carbon production rate is only a lower limit to the evaporation rate of the carbon bearing mother molecule.

Feldman, P. D.↗

Loss and Isotopic Fractionation of Alkali Elements during Diffusion-Limited Evaporation from Molten Silicate: Theory and Experiments

Moderately volatile elements (MVEs) are variably depleted in planetary bodies, reflecting the imprints of nebular and planetary processes. Among MVEs, Na, K, and Rb are excellent tracers for unraveling the history of MVE depletion in planetary bodies because they have similar geochemical behaviors but can be chemically fractionated by evaporation and condensation processes. Furthermore, K and Rb are amenable to high-precision isotopic analyses, which can help constrain the conditions of evaporation and condensation. To quantitatively understand why Na, K, and Rb are depleted in planetary bodies, we have carried out vacuum evaporation experiments from basaltic melt at 1200 and 1400 °C to study their evaporation kinetics and isotopic fractionations. We chose this composition because it is relevant to evaporation from small differentiated planetesimals. The Rb isotopic compositions of the evaporation residues were measured by multicollector inductively coupled plasma mass spectrometry (MC-ICPMS), and the K isotopic compositions were measured along profiles across the residues by secondary ion mass spectrometry (SIMS). In the 1400 °C run products, we found that the concentrations of both K and Rb in the run products decreased from core to rim, which was accompanied by a heavy K isotope enrichment near the surface. This indicates that, in this run, evaporation was limited by diffusion. To use those data quantitatively, we derive analytical equations that describe the evaporation rate and isotopic fractionation associated with diffusion-limited evaporation from a sphere, slab, and cylinder in transient and quasi-steady state regimes. This model is used to tease out the roles that diffusive transport in the melt and evaporation at the melt/gas interface play in setting the elemental depletion and isotopic composition of the residue. Under our experimental conditions, volatility decreases in the order of Na, Rb, and K. Using our experimental results in a thermodynamic model, we have estimated the product γΓ of activity coefficients × evaporation coefficients of Na, Rb, and K. The measured isotopic compositions of the residues are well explained using Rayleigh distillations, whereby the relative volatilities of K and Rb isotopes are given by the square root of their masses. We use our results and previously published data to predict how K and Rb could have been lost as a function of temperature, melt composition, oxygen fugacity, and saturation degree relevant to Vesta’s building blocks. We find that the K and Rb depletions, K/Rb elemental fractionation, and δ 41 K and δ 87 Rb isotopic fractionations of Vesta (as sampled by howardite-eucrite-diogenite (HED) meteorites) are best explained by evaporation of submillimeter size objects for 0.1-10 years at moderate temperatures (~1050 °C) in a medium ~98.8% saturated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

HCMM hydrological analysis in Utah

Progress in analysis of Heat Capacity Mapping Mission (HCMM) infrared and visible observations of the hydrology of Utah Lake is reported. Correlation between HCMM intensities converted to temperature and ground truth temperatures was investigated, and a conversion offset value determined. Ground truth surface temperatures minus HCMM temperatures were plotted against several hydrological parameters. Relationships among visible data, thermal data, and algae concentrations were considered, and summer concentrations of predominant algae species determined. Investigations on the effects of varying algae concentrations on evaporation rates are reported. Efforts to develop a model for evaporation estimation are reported. The relationship between air and water surface temperatures was studied and the temperature distribution in different segments of the lake investigated. Indications of the existence of thermal springs are reported. Correlation of HCMM surface temperature data and depth to groundwater were investigated.

Source record↗

Crystallization of proteins by dynamic control of supersaturation

The growth of protein crystals is known to be the limiting factor in the determination of the three-dimensional structures of most proteins. It is expected that the kinetics of supersaturation, which is directly related to solvent evaporation, will affect protein crystal growth and nucleation and accordingly determine the quality, number, size, and morphology of the crystals. With a technique that controls the evaporation of solvent from a protein solution with N2(g) it is possible to determine the effect of different evaporation profiles on hen egg white lysozyme crystals. Hen egg white lysozyme was chosen as the model protein because it crystallizes easily and has solubility data available for most salt, pH, and temperature ranges. Commercially available lysozyme was further purified by a number of methods. Crystals grown with the purified lysozyme and with the unpurified lysozyme in citrate buffer were different shapes but were found to be of the same symmetry space group by precession photos. Differences were seen in the lysozyme crystals grown using different evaporation rates. At three of the four initial conditions for lysozyme crystal growth, longer evaporation times yielded better crystals. The evaporation times required to see a change in the appearance of the crystals was much longer than expected. The number of rates studied so far represent only a small fraction of the ones now available with the gas evaporation device. The technique also provides for control of both solution pH and temperature which are related to the solubilities of proteins.

Wilson, Lori June↗

Water cycle and its management for plant habitats at reduced pressures

Experimental and mathematical models were developed for describing and testing temperature and humidity parameters for plant production in bioregenerative life support systems. A factor was included for analyzing systems operating at low (10-101.3 kPa) pressure to reduce gas leakage and structural mass (e.g., inflatable greenhouses for space application). The expected close relationship between temperature and relative humidity was observed, along with the importance of heat exchanger coil temperature and air circulation rate. The presence of plants in closed habitats results in increased water flux through the system. Changes in pressure affect gas diffusion rates and surface boundary layers, and change convective transfer capabilities and water evaporation rates. A consistent observation from studies with plants at reduced pressures is increased evapotranspiration rates, even at constant vapor pressure deficits. This suggests that plant water status is a critical factor for managing low-pressure production systems. The approach suggested should help space mission planners design artificial environments in closed habitats.

NASA Center KSC↗

Absolute Density Calibration Cell for Laser Induced Fluorescence Erosion Rate Measurements

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser-induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. This work examines the suitability of the density cell as an absolute calibration source for LIF measurements, and the intrinsic error was evaluated.

Domonkos, Matthew T.↗

LIF Density Measurement Calibration Using a Reference Cell

Flight qualification of ion thrusters typically requires testing on the order of 10,000 hours. Extensive knowledge of wear mechanisms and rates is necessary to establish design confidence prior to long duration tests. Consequently, real-time erosion rate measurements offer the potential both to reduce development costs and to enhance knowledge of the dependency of component wear on operating conditions. Several previous studies have used laser induced fluorescence (LIF) to measure real-time, in situ erosion rates of ion thruster accelerator grids. Those studies provided only relative measurements of the erosion rate. In the present investigation, a molybdenum tube was resistively heated such that the evaporation rate yielded densities within the tube on the order of those expected from accelerator grid erosion. A pulsed UV laser was used to pump the ground state molybdenum at 345.64nm, and the non-resonant fluorescence at 550-nm was collected using a bandpass filter and a photomultiplier tube or intensified CCD array. The sensitivity of the fluorescence was evaluated to determine the limitations of the calibration technique. The suitability of the diagnostic calibration technique was assessed for application to ion engine erosion rate measurements.

Domonkos, Matthew T.↗

Laser heating and evaporation of a single droplet

The laser technology is being abundantly studied for controlled energy deposition for a range of applications in aerodynamic flow control, material processing, ignition, and combustion. The absorption of laser radiation by liquid droplets affects further propagation of laser in the atmosphere and causes bleaching of suspended droplets while the ignition and combustion characteristics in combustors are influenced by the evaporation rate of the sprayed fuel. In this work, we present a multi-dimensional mathematical model built on OpenFOAM for laser heating and evaporation of a single droplet in the diffusion dominated regime taking into account absorption of the laser radiation, evaporation process and vapor flow dynamics. The developed solver is validated against available experimental and numerical data for the ethanol and water droplet heating and evaporation. For continuous heating the peak temperature is established by the balance of cooling, evaporation and heating and results in high temperature for larger droplets. It has been shown that for heating by a single laser pulse the maximum temperature of droplets depends only on the peak intensity of the laser radiation. Furthermore, for the peak irradiance close to the transition to the boiling regime, temporal dynamics of the droplet temperature is independent of the droplet size. With proper normalization of time, the dynamics of the droplet shrinkage and cooling is shown to be independent of droplet sizes and peak laser intensities. The influence of cooling and evaporation processes on droplet heating was found to be controlled by the pulse repetition rate for repeated pulse operation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sources of Sahel precipitation for simulated drought and rainy seasons

The sources of sub-Saharan precipitation are studied using diagnostic procedures integrated into the code of the GISS climate model. Water vapor evaporating from defined source regions is 'tagged', allowing the determination of the relative contributions of each evaporative source to the simulated July rainfall in the Sahel. Two June-July simulations are studied to compare the moisture sources, moisture convergence patterns and the spatial variations of precipitation for rainy and drought conditions. Results for this case study indicate that patterns of moisture convergence and divergence over northern Africa had a stronger influence on model rainfall over the sub-Sahara than did evaporation rates over the adjacent oceans or moisture advection from ocean to continent. While local continental evaporation contributed significant amounts of water to Sahelian precipitation in the'rainy' simulation, moisture from the Indian Ocean did not precipitate over the Sahel in either case.

Druyan, Leonard M.↗

ASTM E 1559 method for measuring material outgassing/deposition kinetics has applications to aerospace, electronics, and semiconductor industries

The American Society for Testing and Materials has published a new standard test method for characterizing time and temperature-dependence of material outgassing kinetics and the deposition kinetics of outgassed species on surfaces at various temperatures. This new ASTM standard, E 1559(1), uses the quartz crystal microbalance (QCM) collection measurement approach. The test method was originally developed under a program sponsored by the United States Air Force Materials Laboratory (AFML) to create a standard test method for obtaining outgassing and deposition kinetics data for spacecraft materials. Standardization by ASTM recognizes that the method has applications beyond aerospace. In particular, the method will provide data of use to the electronics, semiconductor, and high vacuum industries. In ASTM E 1559 the material sample is held in vacuum in a temperature-controlled effusion cell, while its outgassing flux impinges on several QCM's which view the orifice of the effusion cell. Sample isothermal total mass loss (TML) is measured as a function of time from the mass collected on one of the QCM's which is cooled by liquid nitrogen, and the view factor from this QCM to the cell. The amount of outgassed volatile condensable material (VCM) on surfaces at higher temperatures is measured as a function of time during the isothermal outgassing test by controlling the temperatures of the remaining QCM's to selected values. The VCM on surfaces at temperatures in between those of the collector QCM's is determined at the end of the isothermal test by heating the QCM's at a controlled rate and measuring the mass loss from the end of the QCM's as a function of time and temperature. This reevaporation of the deposit collected on the QCM's is referred to as QCM thermogravimetric analysis. Isothermal outgassing and deposition rates can be determined by differentiating the isothermal TML and VCM data, respectively, while the evaporation rates of the species can be obtained as a function of temperature by differentiating the QCM thermogravimetric analysis data.

Garrett, J. W.↗