New Whole-House Solutions Case Study: Exterior Rigid Foam Insulation at the Edge of a Slab Foundation, Fresno, California

Exterior rigid foam insulation at the edge of the slab foundation was a unique feature for this low-load, unoccupied test house in a hot-dry climate and may be more appropriate for climates with higher heating loads. U.S. Department of Energy Building America research team IBACOS worked with National Housing Quality Award winner Wathen-Castanos Hybrid Homes, Inc., to assess the performance of this feature in a single-family detached ranch house with three bedrooms and two full bathrooms constructed on a slab-on-grade foundation in Fresno, California. One challenge during installation of the system was the attachment of the butyl flashing to the open framing. To solve this constructability issue, the team added a nailer to the base of the wall to properly attach and lap the flashing. In this strategy, R-7.5, 1.5-in.-thick extruded polystyrene was installed on the exterior of the slab for a modeled savings of 4,500 Btu/h on the heating load.

Building America↗

Technology Solutions Case Study: Monitoring of Double Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts

Double stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. In this project, Building Science Corporation monitored moisture conditions in double-stud walls from 2011 through 2014 at a new production house located in Devens, Massachusetts. The builder, Transformations, Inc., has been using double-stud walls insulated with 12 in. of open cell polyurethane spray foam (ocSPF); however, the company has been considering a change to netted and blown cellulose insulation for cost reasons. Cellulose is a common choice for double-stud walls because of its lower cost (in most markets). However, cellulose is an air-permeable insulation, unlike spray foams, which increases interior moisture risks. The team compared three double-stud assemblies: 12 in. of ocSPF, 12 in. of cellulose, and 5-½ in. of ocSPF at the exterior of a double-stud wall (to approximate conventional 2 × 6 wall construction and insulation levels, acting as a control wall). These assemblies were repeated on the north and south orientations, for a total of six assemblies.

BSC↗

Effect of insulator surface conditioning on the pinch dynamics and x-ray production of a Ne-filled dense plasma focus

The dense plasma focus (DPF) can be an intense source of x rays, wherein the insulator sleeve strongly dictates the electrical breakdown, which subsequently affects the formation of a plasma sheath and a collapse phase. Experiments on a 25 kJ DPF (operated at 4.4 kJ) are carried out to demonstrate the influence of insulator surface morphology on the pinch structure, dynamics, and x-ray yield using a Ne fill. Two borosilicate insulators are directly compared, one with a smooth finish and the other machined with four circumferential grooves traversing the perimeter of the exterior insulator surface. Comparisons are made through same-shot imaging diagnostics of the evolving plasma sheath during breakdown, rundown, and at the pinch in addition to the time-resolved measurements of emitted x rays via filtered photodiodes. The presence of structures on the insulator sleeve reduces x-ray production across all fill pressures by a factor of 2.8 ± 2.4 on average and reduces the highest x ray producing shots by a factor of 5. ± 1.8. Observations of sheath asymmetry and inhomogeneity at lift-off are observed and correlated with subsequent observations of off-axis radial collapse. Taken together, this suggests that local variations in the insulator surface decrease the spatial uniformity of the sheath, leading to an azimuthally asymmetric focus, reduced electron densities, and, ultimately, degraded x-ray production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exterior Rigid Foam Insulation at the Edge of a Slab Foundation, Fresno, California (Fact Sheet)

Exterior rigid foam insulation at the edge of the slab foundation was a unique feature for this low-load, unoccupied test house in a hot-dry climate and may be more appropriate for climates with higher heating loads. U.S. Department of Energy Building America research team IBACOS worked with National Housing Quality Award winner Wathen-Castanos Hybrid Homes, Inc., to assess the performance of this feature in a single-family detached ranch house with three bedrooms and two full bathrooms constructed on a slab-on-grade foundation in Fresno, California. One challenge during installation of the system was the attachment of the butyl flashing to the open framing. To solve this constructability issue, the team added a nailer to the base of the wall to properly attach and lap the flashing. In this strategy, R-7.5, 1.5-in.-thick extruded polystyrene was installed on the exterior of the slab for a modeled savings of 4,500 Btu/h on the heating load.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination and Assessment of Optimum Internal Thermal Insulation for Masonry Walls in Historic Multifamily Buildings

A large portion of existing building stock is comprised of load-bearing masonry buildings, particularly in the Midwest and on the East Coast, though such buildings are distributed across the US. Most of them have uninsulated walls or suffer from insufficient thermal insulation materials. These buildings are inseparable parts of the cultural, social, and economic characteristics of their cities. Due to heritage and preservation concerns, zoning, and space restrictions, they cannot be retrofitted with exterior insulation. Interior insulation must therefore be considered as an alternative. Lack of insulation directly results in energy waste as well as heat loss and gain. Furthermore, it adversely affects heating, ventilation, and air conditioning (HVAC) loads, equipment sizing, indoor air quality, and thermal comfort for residents. The objective of this study is to simulate and evaluate the effects of various internal thermal insulation materials and strategies on mass masonry load-bearing walls in multifamily buildings with attention to various variables and parameters. It not only addresses the energy performance and cost savings associated with an interior insulation retrofit, but also outlines other variables and parameters that are factors in the selection of optimum insulation material, including installations costs, payback periods, useful internal space loss, and options for the depth of the interior insulation retrofit. In conclusion, the audience for this paper is diverse: homeowners, contractors and remodelers, architects and designers, engineers, housing and preservation authorities, and more can benefit from understanding the results outlined in this study.

42 ENGINEERING↗

Measure Guideline: Three High Performance Mineral Fiber Insulation Board Retrofit Solutions

This Measure Guideline describes a high performance enclosure retrofit package that uses mineral fiber insulation board. The Measure Guideline describes retrofit assembly and details for wood frame roof and walls and for cast concrete foundations. This Measure Guideline is intended to serve contractors and designers seeking guidance for non-foam exterior insulation retrofit.

&#8203↗

Monitoring of Double Stud Wall Moisture Conditions in the Northeast

Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double stud walls have a higher risk of interior-sourced condensation moisture damage, when compared with high-R approaches using exterior insulating sheathing.; Moisture conditions in double stud walls were monitored in Zone 5A (Massachusetts); three double stud assemblies were compared.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Monitoring of Double Stud Wall Moisture Conditions in the Northeast, Devens, Massachusetts (Fact Sheet)

Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double stud walls have a higher risk of interior-sourced condensation moisture damage, when compared with high-R approaches using exterior insulating sheathing. Moisture conditions in double stud walls were monitored in Zone 5A (Massachusetts); three double stud assemblies were compared.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Monitoring of Double-Stud Wall Moisture Conditions in the Northeast

Double-stud walls insulated with cellulose or low-density spray foam can have R-values of 40 or higher. However, double-stud walls have a higher risk of interior-sourced condensation moisture damage when compared with high-R approaches using exterior insulating sheathing. Moisture conditions in double-stud walls were monitored in Zone 5A (Massachusetts); three double-stud assemblies were compared.

42 ENGINEERING↗

Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes

This guide provides information and recommendations to the following groups: insulation contractors; general contractors; builders; home remodelers; mechanical contractors; and homeowners, as a guide to the work that needs to be done. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues. And durability issues are more important than saving energy. Not all techniques can apply to all houses. Special conditions will require special action. Some builders or homeowners will wish to do more than the important but basic retrofit strategies outlined by this guide. The following are best practice and product recommendations from the interviewed contractors and homebuilders who collectively have a vast amount of experience. Three significant items were discussed with the group which are required to make taped insulating sheathing a simple, long term, and durable drainage plane: 1. Horizontal joints should be limited or eliminated wherever possible; 2. Where a horizontal joint exists use superior materials; 3. Frequent installation inspection and regular trade training are required to maintain proper installation. Section 5 of this measure guideline contains the detailed construction procedure for the three recommended methods to effectively seal the joints in exterior insulating sheathing to create a simple, long term, and durable drainage plane.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building America Case Study: Measure Guideline: Guidance on Taped Insulating Sheathing Drainage Planes (Fact Sheet)

This guide provides information and recommendations to the following groups: Insulation contractors, General contractors, Builders, Home remodelers, Mechanical contractors, and Homeowners as a guide to the work that needs to be done. The order of work completed during home construction and retrofit improvements is important. Health and safety issues must be addressed first and are more important than durability issues. And durability issues are more important than saving energy. Not all techniques can apply to all houses. Special conditions will require special action. Some builders or homeowners will wish to do more than the important but basic retrofit strategies outlined by this guide. The following are best practice and product recommendations from the interviewed contractors and home builders who collectively have a vast amount of experience. Three significant items were discussed with the group which are required to make taped insulating sheathing a simple, long term, and durable drainage plane: 4. Horizontal joints should be limited or eliminated wherever possible 5. Where a horizontal joint exists use superior materials 6. Frequent installation inspection and regular trade training are required to maintain proper installation Section 5 of this measure guideline contains the detailed construction procedure for the three recommended methods to effectively seal the joints in exterior insulating sheathing to create a simple, long term, and durable drainage plane.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-R Walls for New Construction Structural Performance: Wind Pressure Testing

This technical report is focused primarily on laboratory testing that evaluates wind pressure performance characteristics for wall systems constructed with exterior insulating sheathing. This research and test activity will help to facilitate the ongoing use of non-structural sheathing options and provide a more in-depth understanding of how wall system layers perform in response to high windperturbations normal to the surface.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High-R Walls for New Construction Structural Performance: Wind Pressure Testing

This technical report is focused primarily on laboratory testing that evaluates wind pressure performance characteristics for wall systems constructed with exterior insulating sheathing. This research and test activity will help to facilitate the ongoing use of non-structural sheathing options and provide a more in-depth understanding of how wall system layers perform in response to high wind perturbations normal to the surface.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and Moisture Impact of EIFS Walls in the USA

ABSTRACT This paper summarizes a family of computer simulations that have been performed to assess the hygrothermal performance of exterior insulation finish systems and discusses the validation of the model prior to its use. This research deals with evaluation of the performance of a number of selected wall systems in all 8 IECC USA climate zones. The research produced a range of performances that are representative of generic EIFS wall systems, and not for a specific manufactured product. A comparison was performed between three different EIFS walls and a brick wall system.

Desjarlais, Andre Omer↗

Efficient Solutions for New Homes Case Study: Savannah Gardens

The Savannah Housing Department is leading sustainable and affordable housing development in Georgia. It partnered with Southface Energy Institute, a member of the U.S. Department of Energy’s Partnership for Home Innovation Building America research team, to seek cost-effective solutions for increasing the energy efficiency of the Savannah Housing Department’s standard single-family home plans in the Savannah Gardens Community. Based on engineering, cost, and constructability analyses, the combined research team chose to pilot two technologies to evaluate efficiency and comfort impacts for homeowners: a heat-pump water heater in an encapsulated attic and an insulated exterior wall sheathing.

building america↗

Stand-Off Furring in Deep Energy Retrofits: Syracuse, New York (Fact Sheet)

IBACOS, in collaboration with GreenHomes America, was contracted by the New York State Energy Research and Development Authority to research exterior wall insulation solutions. This research investigated cost-effective deep energy retrofit (DER) solutions for improving the building shell exterior while achieving a cost-reduction goal, including reduced labor costs to reach a 50/50 split between material and labor. The strategies included exterior wall insulation plus energy upgrades as needed in the attic, mechanical and ventilation systems, and basement band joist, walls, and floors. The work can be integrated with other home improvements such as siding or window replacement. This strategy minimizes physical connections to existing wall studs, encapsulates existing siding materials (including lead paint) with spray foam, and creates a vented rain screen assembly to promote drying. GreenHomes America applied construction details created by IBACOS to a test home. 2x4 framing members were attached to the wall at band joists and top plates using 'L' clips, with spray foam insulating the wall after framing was installed. Windows were installed simultaneously with the framing, including extension jambs. The use of clips in specific areas provided the best strength potential, and 'picture framing' the spray foam held the 2x4s in place. Short-term testing was performed at this house, with monitoring equipment installed for long-term testing. Testing measurements will be provided in a later report, as well as utility impact (before and after), costs (labor and materials), construction time, standard specifications, and analysis for the exterior wall insulation strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture and Structural Analysis for High Performance Hybrid Wall Assemblies

This report describes the work conducted by the Building Science Corporation (BSC) Building America Research Team's 'Energy Efficient Housing Research Partnerships' project. Based on past experience in the Building America program, they have found that combinations of materials and approaches—in other words, systems—usually provide optimum performance. No single manufacturer typically provides all of the components for an assembly, nor has the specific understanding of all the individual components necessary for optimum performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

New York State Energy Research and Development Authority Exterior Building Solutions To Insulation

TO4 8.2.2: Space Cond. for Deep Energy Retrofits The purpose of this project for the New York State Energy Research and Development Authority (NYSERDA) is to find new or improved strategies for exterior building solutions in regard to insulation that will provide extensive energy-savings benefits for homeowners. Deep energy retrofits (DER) is one of the solutions. In the past, DERs have been expensive and hard for the average homeowner to budget. The DER solutions that IBACOS and GreenHomes America (GHA) are proposing will be market friendly, affordable, and easily repeatable. The insulation strategies that will be used on nine test homes include the following: - Rigid foam insulation - Four homes will have approximate center-of-wall R-values of R-28, including furring strips for siding, with additional systems approach work to supply the complete integrated DER solution. - Spray foam insulation - Four homes will have approximate center-of-wall R-values of R-30, with additional systems approach work to supply the complete integrated DER solution. - HPwES upgrade - One home will include criteria from the Home Performance with ENERGY STAR (HPwES) program, including dense pack walls and window upgrades for this retrofit strategy. In addition to the insulation, the strategies will include treatment where needed in the attic, mechanical systems, ventilation and basement band joist, walls, and floors.