Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electrodes, Implanted”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Study directed at development of an implantable biotelemetry ion detector

A literature search was conducted to currently update known information in the field of ion-selective electrodes. The review attempts to identify present trends in cation and anions selective electrodes pertinent to the area of bioimplantable units. An electronic circuit was designed to provide the high impedance interface between the ion-selective sensors and signal-processing equipment. The resulting design emphasized the need for low power and miniaturization. Many of the circuits were constructed and used to evaluate the ion-selective electrodes. A cuvette capable of holding the ion-selective and the reference electrodes was designed and constructed. This equipment was used to evaluate commercially available ion-selective electrodes and the electrodes designed and constructed in the study. The results of the electrode tests are included.

Hanley, L. D.↗

Vestibulo-ocular and vestibulospinal function before and after cochlear implant surgery

Vestibular function in cochlear implant candidates varies from normal to total absence of function. In patients with intact vestibular function preoperatively, invasion of the otic capsule places residual vestibular function at risk. Speech-processing strategies that result in large amplitude electrical transients or strategies that employ high amplitude broad frequency carrier signals have the potential for disrupting vestibular function. Five patients were tested with and without electrical stimulation via cochlear electrodes. Two patients experienced subjective vestibular effects that were quickly resolved. No long-term vestibular effects were noted for the two types of second generation cochlear implants evaluated. Histopathological findings from another patient, who had electrically generated vestibular reflex responses to intramodiolar electrodes, indicated that responses elicited were a function of several variables including electrode location, stimulus intensity, stimulus amplitude, and stimulus frequency. Differential auditory, vestibulocolic, and vestibulospinal reflexes were demonstrated from the same electrode as a function of stimulus amplitude, frequency, and duration.

Case Reports↗

A study on sub-bandgap photoexcitation in nitrogen- and boron-doped diamond with interdigitated device structure

Diamond is an ultrawide-bandgap semiconductor suitable for high power devices that require high current carrying capacity, high blocking voltages, and smaller form factors. We investigated various diamond structures for extrinsic photoconductive semiconductor switches, including an insulating high-pressure high-temperature type Ib (highly nitrogen-doped) substrate, a chemical vapor deposited (CVD) type IIa (unintentionally doped) substrate, a CVD grown semiconducting boron-doped epilayer on a type IIa substrate, and boron-implanted type Ib and IIa substrates. Using these samples, we fabricated and characterized planar interdigitated photoconductive switches with 30 μm, electrode gaps. 532 and 1064 nm Nd:YAG laser pulses with energies up to 3.5 mJ/pulse were used to trigger the switches. Photoresponses were measured at bias voltages ranging from 10 to 100 V, corresponding to electric fields of 3.3–33 kV/cm. In this field range, the type Ib device exhibited the highest average on/off-state current ratio, on the order of 10 11 , when triggered with 0.8 mJ/pulse, 532 nm laser pulses. However, only the CVD grown boron-doped epilayer and boron implanted IIa devices showed decent sensitivity to 1064 nm.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Flip chip packaging of a MEMS neuro-prosthetic system

A joint research team from California Institute of Technology and Jet Propulsion Laboratory is developing a fully miniaturized, smart implantable neuro-prosthetic system, by combining integrated electronics with Micro Electro Mechanical Structure (MEMS) based electrode arrays. The packaging group of this project team has been tasked with designing and fabricating a package to interface electrically between a MEMS electrode array, capable of extracting signals from brain, and an electronic chip, capable of providing on chip conditioning/processing of extracted data, while delivering the output data to a detector located outside the body.

flip↗

Induction powered biological radiosonde

An induction powered implanted monitor for epidurally measuring intracranial pressure and telemetering the pressure information to a remote readout is disclosed. The monitor utilizes an inductance-capacitance (L-C) oscillator in which the C comprises a variable capacitance transducer, one electrode of which is a small stiff pressure responsive diaphragm. The oscillator is isolated from a transmitting tank circuit by a buffer circuit and all electric components in the implanted unit except an input and an output coil are shielded by a metal housing.

Fryer, T. B.↗

Electrochemical patterning of amorphous carbon on diamond

The ability to pattern ion-implantation damaged or other nondiamond carbon on a diamond substrate is useful for fabricating a variety of devices. We accomplished such patterning by an unmasked implantation into a diamond substrate followed by photolithography and a selective electrochemical etch. The use of a high resistivity medium coupled with applied biases over 50 V permitted etching without requiring contact between the substrate and an electrode. Many electrolytes gave etches that exhibit high selectivity for nondiamond carbon over both diamond and dielectrics such as photoresist. Optical, electrical, and Raman spectroscopic measurements elucidate the effects of the etch on the implanted diamond surface.

Marchywka, Mike↗

Single-Layer, Multicolor Electroluminescent Phosphors

Etching eliminated in producing phosphor layers for displays. New process enables production of single-layer, two-color phosphor layer without etching. Method of construction, beginning with glass substrate with electrode and insulator layers, involves deposition of green phosphor masking with metal mask or photoresist; diffusion or ion implantation of manganese through mask to produce red phosphor and removal of mask.

Robertson, James B.↗

Nanotechnologv Enabled Biological and Chemical Sensors

Nanotechnology is an enabling technology that will impact almost all economic sectors: one of the most important and with great potential is the health/medical sector. - Nanomaterials for drug delivery - Early warning sensors - Implantable devices - Artificial parts with improved characteristics Carbon nanotubes and nanofibers show promise for use in sensor development, electrodes and other biomedical applications.

Koehne, Jessica↗

High-Density, Actively Multiplexed µECoG Array on Reinforced Silicone Substrate

Simultaneous interrogation of electrical signals from wide areas of the brain is vital for neuroscience research and can aid in understanding the mechanisms of brain function and treatments for neurological disorders. There emerges a demand for development of devices with highly conformal interfaces that can span large cortical regions, have sufficient spatial resolution, and chronic recording capability while keeping a small implantation footprint. In this work, we have designed 61 channel and 48 channel high-density, cortical, micro-electrocorticographic electrode arrays with 400 µm pitch on an ultra-soft but durable substrate. We have also developed a custom multiplexing integrated circuit (IC), methods for packaging the IC in a water-tight liquid crystal polymer casing, and a micro-bonding method for attaching the electronics package to the electrode array. With the integrated multiplexer, the number of external wire connections can be reduced to 16 wires, thereby diminishing the invasive footprint of the device. Both the electrode array and IC were tested in vivo in a rat model to demonstrate the ability to sense finely-localized electrophysiological signals.

Rachinskiy, Iakov↗

Implantable Heart Aid

Medrad utilized NASA's Apollo technology to develop a new device called the AID implantable automatic pulse generator which monitors the heart continuously, recognizes the onset of ventricular fibrillation and delivers a corrective electrical shock. AID pulse generator is, in effect, a miniaturized version of the defibrillator used by emergency squads and hospitals to restore rhythmic heartbeat after fibrillation, but has the unique advantage of being permanently available to the patient at risk. Once implanted, it needs no specially trained personnel or additional equipment. AID system consists of a microcomputer, a power source and two electrodes which sense heart activity.

Source record↗

Implantable neuromodulation system for closed-loop stimulation and recording simultaneously at multiple brain sets

The present disclosure relates to a modular system for deep brain stimulation (DBS) and electrocorticography (ECoG). The system may have an implantable neuromodulator for generating electrical stimulation signals adapted to be applied to a desired region of a brain via an attached electrode array. An aggregator module may be used for collecting and aggregating electrical signals and transmitting the electrical signals to the neuromodulator. A control module may be used which is in communication with the aggregator module for controlling generation of the electrical signals and transmitting the electrical signals to the aggregator.

Pannu, Satinderpall S.↗

Alkaline Capacitors Based on Nitride Nanoparticles

High-energy-density alkaline electrochemical capacitors based on electrodes made of transition-metal nitride nanoparticles are undergoing development. Transition- metal nitrides (in particular, Fe3N and TiN) offer a desirable combination of high electrical conductivity and electrochemical stability in aqueous alkaline electrolytes like KOH. The high energy densities of these capacitors are attributable mainly to their high capacitance densities, which, in turn, are attributable mainly to the large specific surface areas of the electrode nanoparticles. Capacitors of this type could be useful as energy-storage components in such diverse equipment as digital communication systems, implanted medical devices, computers, portable consumer electronic devices, and electric vehicles.

Aldissi, Matt↗

Ion beam accelerator system

A system is described that combines geometrical and electrostatic focusing to provide high ion extraction efficiency and good focusing of an accelerated ion beam. The apparatus includes a pair of curved extraction grids with multiple pairs of aligned holes positioned to direct a group of beamlets along converging paths. The extraction grids are closely spaced and maintained at a moderate potential to efficiently extract beamlets of ions and allow them to combine into a single beam. An accelerator electrode device downstream from the extraction grids is at a much lower potential than the grids to accelerate the combined beam. The application of the system to ion implantation is mentioned.

Aston, G.↗

Performance and properties of arsenic passivated lithium-titanium disulfide cells

In order to inhibit chemical degradation associated with the lithium-electrolyte interaction in ambient temperature lithium cells, an attempt was made to synthetically passivate the anode via ion implantation of arsenic. Solvent reduction is reduced although salt reaction with lithium is still present. The performance of the Li-TiS2 cell differs from those with standard electrodes, but further work is necessary to clarify the efficacy of this mode of passivation.

Yen, S. P. S.↗

Space Derived Health Aids (AID, Heart Monitor)

CPI's spinoff from miniaturized pace circuitry is the new heart-assist device, the AID implantable automatic pulse generator. AID pulse generator monitors the heart continuously, recognizes onset of fibrillation, then administers a corrective electrical shock. A mini- computer, a power source, and two electrodes which sense heart activity are included in the unit. An associated system was also developed. It includes an external recorder to be worn by AID patients and a physician's console to display the data stored by the recorder. System provides a record of fibrillation occurrences and the ensuing defibrillation.

Source record↗

Scalable Nano-Scaffold SOFC Anode Architecture Enabling Direct Hydrocarbon Utilization

This project is based on WVU’s pending patents, technology and aims to design and modify the internal surfaces of the Ni/YSZ anode from currently commercially viable Solid Oxide Fuel Cells (SOFCs) using the additive manufacturing process of Atomic Layer Deposition (ALD). The surface architecture/scaffold added onto the internal surface of the anode possesses an engineered nanostructure but it features only commonly-used oxide conductors and electro-catalyst materials. The surface layer possesses a minimum thickness of ~2-40 nm and is solely designed to control the surface reforming reactions and to increase catalytic activity. Three-dimensional (3D) nano scaffold architectures with the noble metal nano-catalyst, low-cost bimetallic catalytic alloys, and nano-scale ionic conducting oxide fully compatible with the state-of-the-art Ni/YSZ anode, were applied to the internal surface of the entire porous SOFC anode using ALD. In the present work, the surface scaffold architecture is essentially multi-functional at the nano-scale, facilitated by the multiple heterostructured interfaces. It will significantly enhance the power density and cell durability for direct hydrocarbon utilization by (1) increasing the number of electrochemical reaction sites to enhance the hydrogen/hydrocarbon oxidation reactions; (2) reducing carbon formation; (3) mitigating the coarsening of backbone Ni phase and the oxidation attack of Ni from oxidants (e.g., H2O, CO2); and (4) promoting the internal reforming capabilities, especially for natural gas applications. ALD is employed to generate stable anode surface architectures that are uniform, precisely controllable at the atomic scale, and accurately repeatable for processing. The engineered anode surface nano-scaffold architecture was cataloged and analyzed using High-resolution Transmission Electron Microscopy (TEM), and cell power/durability performance assessed via comprehensive electrochemical performance testing with commercial specimens and relevant environments using hydrocarbon fuels. To the best of our knowledge, this project is the First Report on ALD of Ni/YSZ. The actual achievement of this Project includes (1). Successful demonstration of 7 types of ALD layers on Ni/YSZ anode, including Co, Ni, Mn, Pt, Ru, ZrOx and multi-functional nano-composite. (1). Conformal coating and subsequently spontaneously pinning the discrete nano-catalyst, including the precious metal nano-catalyst and the Ni and Co catalysts, on the YSZ surface upon the electrochemical operation in the reduced atmosphere. Those nano-catalysts on the ionic-conducting YSZ provided excellent sites for promoting internal reforming; (2). Demonstrated ALD coating increased both catalytic activity and conductivity of Ni/YSZ. Conformal coating provided dopants and introduced additional electrical conducting pathways on the YSZ ionic conductor. The doped surface layer of YSZ with mixed conductivity thus further introduces the active triple phase boundaries adjacent to the ALD-coated nano-catalysts such as Pt, Co, and Ni that are pinned on the YSZ surface. The nano-composite ALD coating on Ni/YSZ anode has significantly increased cell durability; and (3). ALD coating of Ni/YSZ anode increased the power density of the entire cell by 300%. For a long time, the SOFC performance, such as the power density, was deemed hindered by the cathode. The sluggish oxygen reduction reaction (ORR) in the cathode was deemed as hindering the power density of the SOFCs. For the anode-supported commercial SOFCs, the cell performance is considered to be limited by the cathode's performance. For the first time in the field of SOFC, this project has demonstrated that (1). the performance of commercial SOFCs can be further increased by the ALD coating on Ni/YSZ anode backbone. (2). ALD coating on Ni/YSZ fuel electrodes results in the enhancement of power density, and increased reliability, robustness, and endurance of SOFCs, for their application using both hydrogen and hydrocarbon fuels over the entire operating temperature range of 650-800ºC for the inherently functional commercial cells. (3). ALD coating provides alternative approaches of exsolutions for introducing the stable catalyst onto the internal surface of the Ni/YSZ electrode. ALD coating could be much more versatile than exsolution in employing the catalysts with various chemistries onto the various backbones. (4). Due to the negligible amount of ALD materials coated onto the internal surface of the porous cathode of the as-fabricated cells, a peak power density increase up to 300 % induced by ALD coating was simultaneously achieved in terms of both power density and specific power. (5). The ALD coating developed through this project was applied to both the SOFC and Solid Oxide Electrolysis Cells (SOEC). SOEC’s face a similar but more demanding need to improve the fuel electrode's performance. It opens further research directions for electrocatalytic surface nanoionics with a wide range of chemistry. It will revolutionize our ability to render the formation of a nanostructured electrode that has been constantly pursued yet barely achieved for practical SOFC/SOEC applications. The research is also immediately transformative since both the preliminary data and the proposed work are on the direct implantation of nanoionics into the state-of-the-art inherently functional SOCs. It represents an immediate impact on the commercial sectors in SOC technology since the applied ALD processing is computer-controlled ALD coating using the commercial ALD systems, and it is scalable to both the single cells and SOC stacks.

36 MATERIALS SCIENCE↗

Diagnosis and Treatment of Neurological Disorders by Millimeter-Wave Stimulation

Increasingly, millimeter waves are being employed for telecomm, radar, and imaging applications. To date in the U.S, however, very few investigations on the impact of this radiation on biological systems at the cellular level have been undertaken. In the beginning, to examine the impact of millimeter waves on cellular processes, researchers discovered that cell membrane depolarization may be triggered by low levels of integrated power at these high frequencies. Such a situation could be used to advantage in the direct stimulation of neuronal cells for applications in neuroprosthetics and diagnosing or treating neurological disorders. An experimental system was set up to directly monitor cell response on exposure to continuous-wave, fixed-frequency, millimeter-wave radiation at low and modest power levels (0.1 to 100 safe exposure standards) between 50 and 100 GHz. Two immortalized cell lines derived from lung and neuronal tissue were transfected with green fluorescent protein (GFP) that locates on the inside of the cell membrane lipid bi-layer. Oxonol dye was added to the cell medium. When membrane depolarization occurs, the oxonal bound to the outer wall of the lipid bi-layer can penetrate close to the inner wall where the GFP resides. Under fluorescent excitation (488 nm), the normally green GFP (520 nm) optical signal quenches and gives rise to a red output when the oxonol comes close enough to the GFP to excite a fluorescence resonance energy transfer (FRET) with an output at 620 nm. The presence of a strong FRET signature upon exposures of 30 seconds to 2 minutes at 5-10 milliwatts per square centimeter RF power at 50 GHz, followed by a return to the normal 520-nm GFP signal after a few minutes indicating repolarization of the membrane, indicates that low levels of RF energy may be able to trigger non-destructive membrane depolarization without direct cell contact. Such a mechanism could be used to stimulate neuronal cells in the cortex without the need for invasive electrodes as millimeter waves penetrate skin and bone on the order of 15 mm in depth. Although 50 GHz could not readily penetrate from the outer skull to the center of the cortex, implants on the outer skull or even on the scalp could reach the outer layer of the cerebral cortex where substantial benefit could be realized from such non-contact type excitation.

Siegel, Peter H.↗