Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron Accelerators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Energetic electron acceleration observed by MMS in the vicinity of an X-line crossing

During the first months of observations, the Magnetospheric Multiscale Fly's Eye Energetic Particle Spectrometer instrument has observed several instances of electron acceleration up to >100 keV while in the vicinity of the dayside reconnection region. While particle acceleration associated with magnetic reconnection has been seen to occur up to these energies in the tail region, it had not yet been reported at the magnetopause. This study reports on observations of electron acceleration up to hundreds of keV that were recorded on 19 September 2015 around 1000 UT, in the midst of an X-line crossing. In the region surrounding the X-line, whistler-mode and broadband electrostatic waves were observed simultaneously with the appearance of highly energetic electrons which exhibited significant energization in the perpendicular direction. The mechanisms by which particles may be accelerated via reconnection-related processes are intrinsic to understanding particle dynamics among a wide range of spatial scales and plasma environments.

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical simulation study of positron production by intense laser-accelerated electrons

Positron production by ultra-intense laser-accelerated electrons has been studied with two-dimensional particle-in-cell and Monte Carlo simulations. The dependence of the positron yield on plasma density, plasma length, and converter thickness was investigated in detail with fixed parameters of a typical 100 TW laser system. The results show that with the optimal plasma and converter parameters a positron beam containing up to 1.9 × 10{sup 10} positrons can be generated, which has a small divergence angle (10°), a high temperature (67.2 MeV), and a short pulse duration (1.7 ps)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Improvements to laser wakefield accelerated electron beam stability, divergence, and energy spread using three-dimensional printed two-stage gas cell targets

High intensity, short pulse lasers can be used to accelerate electrons to ultra-relativistic energies via laser wakefield acceleration (LWFA) [T. Tajima and J. M. Dawson, Phys. Rev. Lett. 43, 267 (1979)]. Recently, it was shown that separating the injection and acceleration processes into two distinct stages could prove beneficial in obtaining stable, high energy electron beams [Gonsalves et al., Nat. Phys. 7, 862 (2011); Liu et al., Phys. Rev. Lett. 107, 035001 (2011); Pollock et al., Phys. Rev. Lett. 107, 045001 (2011)]. Here, we use a stereolithography based 3D printer to produce two-stage gas targets for LWFA experiments on the HERCULES laser system at the University of Michigan. We demonstrate substantial improvements to the divergence, pointing stability, and energy spread of a laser wakefield accelerated electron beam compared with a single-stage gas cell or gas jet target.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Collisionless Weibel shocks and electron acceleration in gamma-ray bursts

A study of collisionless external shocks in gamma-ray bursts is presented. The shock structure, electromagnetic field, and process of electron acceleration are assessed by performing a self-consistent 3D particle-in-cell simulation. In accordance with hydrodynamic shock systems, the shock consists of a reverse shock (RS) and forward shock separated by a contact discontinuity. The development and structure are controlled by the ion Weibel instability. The ion filaments are sources of strong transverse electromagnetic fields at both sides of the double shock structure over a length of 30–100 ion skin depths. Electrons are heated up to a maximum energy ϵ{sub ele}≈√(ϵ{sub b}), where ϵ is the energy normalized to the total incoming energy. Jet electrons are trapped in the RS transition region due to the presence of an ambipolar electric field and reflection by the strong transverse magnetic fields in the shocked region. In a process similar to shock surfing acceleration for ions, electrons experience drift motion and acceleration by ion filament transverse electric fields in the plane perpendicular to the shock propagation direction. Ultimately, accelerated jet electrons are convected back into the upstream.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron acceleration and emission in a field of a plane and converging dipole wave of relativistic amplitudes with the radiation reaction force taken into account

A comparative analysis is performed of the electron emission characteristics as the electrons move in laser fields with ultra-relativistic intensity and different configurations corresponding to a plane or tightly focused wave. For a plane travelling wave, analytical expressions are derived for the emission characteristics, and it is shown that the angular distribution of the radiation intensity changes qualitatively even when the wave intensity is much less than that in the case of the radiation-dominated regime. An important conclusion is drawn that the electrons in a travelling wave tend to synchronised motion under the radiation reaction force. The characteristic features of the motion of electrons are found in a converging dipole wave, associated with the curvature of the phase front and nonuniformity of the field distribution. The values of the maximum achievable longitudinal momenta of electrons accelerated to the centre, as well as their distribution function are determined. The existence of quasi-periodic trajectories near the focal region of the dipole wave is shown, and the characteristics of the emission of both accelerated and oscillating electrons are analysed. (extreme light fields and their applications)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laboratory measurements of the physics of auroral electron acceleration by Alfvén waves

While the aurora has attracted attention for millennia, important questions remain unanswered. Foremost is how auroral electrons are accelerated before colliding with the ionosphere and producing auroral light. Powerful Alfvén waves are often found traveling Earthward above auroras with sufficient energy to generate auroras, but there has been no direct measurement of the processes by which Alfvén waves transfer their energy to auroral electrons. Here, we show laboratory measurements of the resonant transfer of energy from Alfvén waves to electrons under conditions relevant to the auroral zone. Experiments are performed by launching Alfvén waves and simultaneously recording the electron velocity distribution. Numerical simulations and analytical theory support that the measured energy transfer process produces accelerated electrons capable of reaching auroral energies. The experiments, theory, and simulations demonstrate a clear causal relationship between Alfvén waves and accelerated electrons that directly cause auroras.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Photocathode Research for Electron Accelerators

This dissertation presents studies of two different types of photocathodes used at electron accelerators: GaAs and K2CsSb. The spin polarization of photoelectrons extracted from GaAs photocathodes was evaluated using traditional one-photon absorption and two-photon absorption, to determine the validity of speculation that two-photon absorption would provide significantly higher polarization. To accomplish this study, a novel compact, retarding-field Mott polarimeter was designed, built and commissioned. The second type of photocathode, K2CsSb, was manufactured at Brookhaven National Laboratory and transported to Jefferson Lab in an ultrahigh vacuum "suitcase" and installed within a DC high voltage gun. Charge lifetime measurements were made using a K2CsSb photocathode and compared to those of GaAs under identical operating conditions. The surface morphology of the used K2CsSb was also studied. Many important atomic, nuclear and high energy physics experiments rely on using highly spin-polarized electron beams obtained via photoemission from GaAs photocathodes. Remarkably, even after 30 years of GaAs photogun operation, there are still some lingering questions associated with the beam polarization values being lower than expected. Bulk GaAs can theoretically provide 50% polarization but typically provides ~ 35%. Reduced polarization is attributed to a number of proposed depolarization mechanisms. Recently, it was proposed that two-photon absorption could be exploited to selectively populate the conduction band with electrons of just one spin state providing 100% polarization. These claims were refuted by others on theoretical grounds. In this thesis, for the first time, two-photon photoemission was demonstrated with beam delivered to a novel polarimeter constructed for this experiment. Polarization was found to be comparable to that obtained with conventional one-photon absorption, and to converge to the same value with a reduction in thickness of the active layer, thereby providing additional experimental insight to the polarized photoemission process an depolarization mechanisms in GaAs. Many proposed accelerators (light sources, energy recovery linacs and electron cooling machines) require extremely high average beam current (~ 100mA). The highest average current accelerator today, the FEL at JLab, can operate at up to 10mA and relies on photoemission from GaAs, even though spin polarization is not required. GaAs is an extremely delicate material, prone to failure and requiring ultrahigh vacuum conditions. In the early 1990s, the multi-alkali photocathode K2CsSb was used to demonstrate 32mA average current inside an RF gun with poor vacuum characteristics. This experiment lasted just minutes and was terminated shortly after the high current milestone was met. Based on this early work, many people believe K2CsSb represents a much better photocathode choice for unpolarized accelerator applications, providing high current for long periods of time and under less stringent operating conditions, but a detailed comparative study using the same apparatus has not been done. To address the high current reliability issue, two K2CsSb photocathodes were manufactured at Brookhaven National Lab and transported to Jefferson Lab via an ultrahigh vacuum transport chamber. They were installed within a 200kV DC high voltage photogun. Systematic charge lifetime measurements were performed using both photocathode materials under identical conditions. The performance of K2CsSb was shown to be highly dependent on extracted current. By combining this decay behavior with surface science measurements of the used photocathodes, it was shown that heat quickly disrupts the capability of the K2CsSb photocathode.

McCarter, James↗

WE-G-BRD-09: Novel MRI Compatible Electron Accelerator for MRI-Linac Radiotherapy

Purpose: MRI guided radiotherapy is a rapidly growing field; however current linacs are not designed to operate in MRI fringe fields. As such, current MRI- Linac systems require magnetic shielding, impairing MR image quality and system flexibility. Here, we present a bespoke electron accelerator concept with robust operation in in-line magnetic fields. Methods: For in-line MRI-Linac systems, electron gun performance is the major constraint on accelerator performance. To overcome this, we propose placing a cathode directly within the first accelerating cavity. Such a configuration is used extensively in high energy particle physics, but not previously for radiotherapy. Benchmarked computational modelling (CST, Darmstadt, Germany) was employed to design and assess a 5.5 cell side coupled accelerator with a temperature limited thermionic cathode in the first accelerating cell. This simulation was coupled to magnetic fields from a 1T MRI model to assess robustness in magnetic fields for Source to Isocenter Distance between 1 and 2 meters. Performance was compared to a conventional electron gun based system in the same magnetic field. Results: A temperature limited cathode (work function 1.8eV, temperature 1245K, emission constant 60A/K/cm{sup 2}) will emit a mean current density of 24mA/mm{sup 2} (Richardson’s Law). We modeled a circular cathode with radius 2mm and mean current 300mA. Capture efficiency of the device was 43%, resulting in target current of 130 mA. The electron beam had a FWHM of 0.2mm, and mean energy of 5.9MeV (interquartile spread of 0.1MeV). Such an electron beam is suitable for radiotherapy, comparing favourably to conventional systems. This model was robust to operation the MRI fringe field, with a maximum current loss of 6% compared to 85% for the conventional system. Conclusion: The bespoke electron accelerator is robust to operation in in-line magnetic fields. This will enable MRI-Linacs with no accelerator magnetic shielding, and minimise painstaking optimisation of the MRI fringe field. This work was supported by US (NIH) and Australian (NHMRC & Cancer Institute NSW) government research funding. In addition, I would like to thank cancer institute NSW and the Ingham Institute for scholarship support.

60 APPLIED LIFE SCIENCES↗

Neutron source in the MCNPX shielding calculating for electron accelerator driven facility

Argonne National Laboratory (ANL) of USA and Kharkov Inst. of Physics and Technology (KIPT) of Ukraine have been collaborating on the design development of an experimental neutron source facility. It is an accelerator driven system (ADS) utilizing a subcritical assembly driven by electron accelerator. The facility will be utilized for performing basic and applied nuclear researches, producing medical isotopes, and training young nuclear specialists. Monte Carlo code MCNPX has been utilized as a design tool due to its capability to transport electrons, photons, and neutrons at high energies. However the facility shielding calculations with MCNPX need enormous computational resources and the small neutron yield per electron makes sampling difficulty for the Monte Carlo calculations. A method, based on generating and utilizing neutron source file, was proposed and tested. This method reduces significantly the required computer resources and improves the statistics of the calculated neutron dose outside the shield boundary. However the statistical errors introduced by generating the neutron source were not directly represented in the results, questioning the validity of this methodology, because an insufficiently sampled neutron source can cause error on the calculated neutron dose. This paper presents a procedure for the validation of the generated neutron source file. The impact of neutron source statistic on the neutron dose is examined by calculating the neutron dose as a function of the number of electron particles used for generating the neutron source files. When the value of the calculated neutron dose converges, it means the neutron source has scored sufficient records and statistic does not have apparent impact on the calculated neutron dose. In this way, the validity of neutron source and the shield analyses could be verified. (authors)

43 PARTICLE ACCELERATORS↗

Electron Acceleration during Macroscale Magnetic Reconnection

Here, the first self-consistent simulations of electron acceleration during magnetic reconnection in a macroscale system are presented. Consistent with solar flare observations, the spectra of energetic electrons take the form of power laws that extend more than two decades in energy. The drive mechanism for these nonthermal electrons is Fermi reflection in growing and merging magnetic flux ropes. A strong guide field suppresses the production of nonthermal electrons by weakening the Fermi drive mechanism. For a weak guide field the total energy content of nonthermal electrons dominates that of the hot thermal electrons even though their number density remains small. Our results are benchmarked with the hard x-ray, radio, and extreme ultraviolet observations of the X8.2-class solar flare on September 10, 2017.

79 ASTRONOMY AND ASTROPHYSICS↗

Demonstration of passive plasma lensing of a laser wakefield accelerated electron bunch

We report on the first demonstration of passive all-optical plasma lensing using a two-stage setup. An intense femtosecond laser accelerates electrons in a laser wakefield accelerator (LWFA) to 100 MeV over millimeter length scales. By adding a second gas target behind the initial LWFA stage we introduce a robust and independently tunable plasma lens. We observe a density dependent reduction of the LWFA electron beam divergence from an initial value of 2.3 mrad, down to 1.4 mrad (rms), when the plasma lens is in operation. Such a plasma lens provides a simple and compact approach for divergence reduction well matched to the mm-scale length of the LWFA accelerator. The focusing forces are provided solely by the plasma and driven by the bunch itself only, making this a highly useful and conceptually new approach to electron beam focusing. Possible applications of this lens are not limited to laser plasma accelerators. Since no active driver is needed the passive plasma lens is also suited for high repetition rate focusing of electron bunches. As a result, its understanding is also required for modeling the evolution of the driving particle bunch in particle driven wake field acceleration.

74 ATOMIC AND MOLECULAR PHYSICS↗

H.V. support structure of 3MVDC generator and its protection from HV discharges in vacuum and SF6 gas for DC electron accelerator

Accelerator and Pulse Power Division of BARC has developed a DC electron accelerator for cross linking of polymers, medical sterilisation, preservation of food. The demonstration of stack-gas cleanup for green power generation has been demonstrated successfully. The support structure of the 3MVDC voltage generator is made of Perspex for high dielectric strength, easy availability of raw material, excellent radiation resistance and long term dimensional stability. This paper describes the salient design features of the High voltage support structure in brief. (author)

43 PARTICLE ACCELERATORS↗

Generation of quasi-monochromatic beams of accelerated electrons during interaction of weak-contrast intense femtosecond laser radiation with a metal-foil edge

The formation of monoenergetic beams of accelerated electrons by focusing femtosecond laser radiation with an intensity of 2 Multiplication-Sign 10{sup 17} W cm{sup -2} onto an edge of aluminium foil has been experimentally demonstrated. The electrons had energy distributions peaking in the range from 0.2 to 0.8 MeV and an energy spread less than 20 %. The acceleration mechanism related to the generation of a plasma wave as a result of self-modulation instability of the laser pulse in the subcritical plasma formed the prepulse of the laser system (arriving 10 ns before the main pulse) is considered. Onedimensional PIC simulation of the interaction between the laser radiation and plasma with a concentration of 5 Multiplication-Sign 10{sup 19} cm{sup -3} showed that effective excitation of a plasma wave, as well as the trapping and acceleration of the electron beam with an energy on the order of 1 MeV, may occur in the presence of inhomogeneities in the density at the plasma boundary and in the temporal shape of the beam. (extreme light fields and their applications)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Electron acceleration by laser wakefield and x-ray emission at moderate intensity and density in long plasmas

The dynamics of electron acceleration by laser wakefield and the associated x-rays emission in long plasmas are numerically investigated for parameters close to the threshold of laser self-focusing. The plasma length is set by the use of dielectric capillary tubes that confine the gas and the laser energy. Electrons self-injection and acceleration to the 170 MeVs are obtained for densities as low as 5 x 10{sup 18} cm{sup -3} and a moderate input intensity (0.77 x 10{sup 18} W/cm{sup 2}). The associated x-ray emission at the exit of the capillary tube is shown to be an accurate diagnostic of the electrons self-injection and acceleration process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study on the parameters of the scanning system for the 300 keV electron accelerator

This paper describes the method to identify the magnetic coil parameters of the scanning system. This locally designed low energy electron accelerator with the present energy of 140 keV will be upgraded to 300 keV. In this accelerator, scanning system is required to deflect the energetic electron beam across a titanium foil in vertical and horizontal direction. The excitation current of the magnetic coil is determined by the energy of the electron beam. Therefore, the magnetic coil parameters must be identified to ensure the matching of the beam energy and excitation coil current. As the result, the essential parameters of the effective lengths for X-axis and Y-axis have been found as 0.1198 m and 0.1134 m and the required excitation coil currents which is dependenton the electron beam energies have be identified.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-C-BRC-07: Parametrized GPU Accelerated Electron Monte Carlo Second Check

Purpose: I am presenting a parameterized 3D GPU accelerated electron Monte Carlo second check program. Method: I wrote the 3D grid dose calculation algorithm in CUDA and utilized an NVIDIA GeForce GTX 780 Ti to run all of the calculations. The electron path beyond the distal end of the cone is governed by four parameters: the amplitude of scattering (AMP), the mean and width of a Gaussian energy distribution (E and α), and the percentage of photons. In my code, I adjusted all parameters until the calculated PDD and profile fit the measured 10×10 open beam data within 1%/1mm. I then wrote a user interface for reading the DICOM treatment plan and images in Python. In order to verify the algorithm, I calculated 3D dose distributions on a variety of phantoms and geometries, and compared them with the Eclipse eMC calculations. I also calculated several patient specific dose distributions, including a nose and an ear. Finally, I compared my algorithm’s computation times to Eclipse’s. Results: The calculated MU for all of the investigated geometries agree with the TPS within the TG-114 action level of 5%. The MU for the nose was < 0.5 % different while the MU for the ear at 105 SSD was ∼2 %. Calculation times for a 12MeV 10×10 open beam ranged from 1 second for a 2.5 mm grid resolution with ∼15 million particles to 33 seconds on a 1 mm grid with ∼460 million particles. Eclipse calculation runtimes distributed over 10 FAS workers were 9 seconds to 15 minutes respectively. Conclusion: The GPU accelerated second check allows quick MU verification while accounting for patient specific geometry and heterogeneity.

60 APPLIED LIFE SCIENCES↗

Expected Dose Rates from 1 MeV Electron Accelerator

The purpose of this study was to simulate UCLA’s 1 MeV electron accelerator and calculate the expected dose rates at various locations inside of the lab and outside of the building to see if they fall into safe levels.

61 RADIATION PROTECTION AND DOSIMETRY↗