Calculation of the kick maps generated by a hollow electron lens for studies of high-energy proton beam collimation.
Abstract Not Provided
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Experimental Hall D, with flagship experiment GlueX, was constructed as part of the 12 GeV CEBAF upgrade. A new magnetically extracted electron beam line was installed to support this hall. Bremsstrahlung photons from retractable radiators are delivered to the experiment through a series of collimators following a long drift to allow for beam convergence. Coherent Bremsstrahlung generated by interaction with a diamond radiator will achieve a nominal 40% linear polarization and photon energies between 8.5 and 9 GeV from 12.1 GeV electrons, which are then tagged or diverted to a medium power 60kW electron dump. The expected photon flux is 10 7 -10 8 Hz. This paper discusses the experimental line design, commissioning experience gained since first beam in spring 2014, and the present results of beam commissioning by the experiment.
A model for generation of upper hybrid waves in Jupiter's outer magnetosphere is presented. Energetic electrons accelerated on high-latitude auroral field lines at 1 R(J) altitudes are assumed to stream outwards to the distant magnetosphere. The large decrease in the local magnetic field strength results in a highly collimated, field-aligned electron beam due to conservation of the particle's magnetic moment. As the beam travels outward it passes through the plasma sheet boundary layer region located on the edges of the plasma sheet. Because of the large field-aligned anisotropy of the beam, the distribution is unstable to the excitation of the upper hybrid waves which amplify and then undergo mode conversion at the f(p) layer to generate the Jovian continuum radiation. A novel feature of the model is the beam-anisotropic heat flux instability which drives UH waves unstable without the need for any positive slope on the electron distribution function.
Generation of highly collimated ({theta}{sub div}{approx}10 mrad), quasi-monoenergetic electron beam with peak energy 12 MeV and charge {approx}50 pC has been experimentally demonstrated from self-guided laser wake-field acceleration (LWFA) in a plasma plume produced by laser ablation of solid nylon (C{sub 12}H{sub 22}N{sub 2}O{sub 2}){sub n} target. A 7 TW, 45 fs Ti:sapphire laser system was used for LWFA, and the plasma plume forming pulse was derived from the Nd:YAG pump laser of the same system. The results show that a reproducible, high quality electron beam could be produced from this scheme which is simple, low cost and has the capability for high repetition rate operation.
Electron-cyclotron maser (ECM) is one of the most important emission mechanisms in astrophysics and can be excited efficiently by lower-energy cutoffs of power-law electrons. These non-thermal electrons probably propagate as a directed collimated beam along ambient magnetic fields. This paper investigates the ECM, in which the effect of electron beams is emphasized. Results show the dependence of emission properties of the ECM on the beam feature. The maximum growth rate of the extraordinary mode (X2) rapidly decreases as the beam momentum increases, while the growth rate of the ordinary mode (O1) changes slightly. In particular, the ordinary mode can overcome the extraordinary mode and becomes the fastest growth mode once the beam momentum is large enough. This research presents an extension of the conventional studies on ECM driven by lower-energy cutoffs and may be helpful to understand better the emission process of solar type I radio bursts, which are dominated by the ordinary mode emission.
Laser-driven Compton backscattering (CBS) has been proposed as method for controlling the intensity of colliding bunches in the FCC-ee so as to avoid the flip-flop instability caused by intensity asymmetry in colliding bunches. Laser-based collimation has also been proposed as an indestructible collimator for high-intensity electron beams. We have initiated a laboratory-based test program of these concepts with the E344 experiment at FACET-II. In this paper, we describe simulations of laser–beam interactions at FACET-II and the relevant scaling for FCC-ee. We also describe the experimental setup and diagnostics that will be used to make the measurements at FACET-II.
Laser-driven Compton backscattering (CBS) has been proposed as method for controlling the intensity of colliding bunches in the FCC-ee so as to avoid the flip-flop instability caused by intensity asymmetry in colliding bunches. Laser-based collimation has also been proposed as an indestructible collimator for high-intensity electron beams. We have initiated a laboratory-based test program of these concepts with the E344 experiment at FACET-II. In this paper, we describe simulations of laser-beam interactions at FACET-II and the relevant scaling for FCC-ee. We also describe the experimental setup and diagnostics that will be used to make the measurements at FACET-II.
Using Geant4, a complex simulation code of the interaction between laser photons and relativistic electrons was developed. We implemented physically constrained electron beam emittance and spacial distribution parameters and we also considered a Gaussian laser beam. The code was tested against experimental data produced at the γ-ray beam line GACKO (Gamma Collaboration Hutch of Konan University) of the synchrotron radiation facility NewSUBARU. Here we will discuss the implications of transverse missallignments of the collimation system relative to the electron beam axis.
Argonne's Advanced Photon Source is planning a major upgrade that will increase the storage ring current from the present 100 mA to 200 mA and decrease the beam lifetime due to high charge-per-bunch and substantially smaller transverse beam size. Collimators in the horizontal plane around the storage ring will be used to control beam losses. These collimators will also serve as whole beam dumps in cases where the stored beam must be dumped for machine protection. Another feature of the Upgrade is swap-out injection, in which a stored electron bunch will be extracted to a dedicated swap-out dump when its charge falls to about 90% of the initial value and immediately replaced with a new bunch. Since particle losses will be concentrated in these collimators and beam dumps, there is the potential for high dose rates around these locations and for activation of nearby accelerator components. This paper contains a brief summary of the APS Upgrade, discusses electron losses in the storage ring, and presents calculations of dose rates and induced activity around the collimators and beam dumps. (authors)
The transport of picosecond laser generated fast electrons in a nanowire array is studied with two-dimensional particle-in-cell simulations. Our simulations show that a fast electron beam is initially guided and collimated by strong magnetic filaments in the array. Subsequently, after the decomposition of the structure of nanowire array due to plasma expansion, the beam is still collimated by the resistive magnetic field. An analytical model is established to give a criterion for long-term beam collimation in a nanowire array; it indicates that the nanowire cell should be wide enough to keep the beam collimated in picosecond scale.
Transversal emittance measurements of intense low-energy beams involve use of collimators. As most of the beam is stopped by a collimator, a question arises whether the special conditions in the vicinity of the collimator influence emittance measurement. In particular, the secondary electrons emitted from the slit surface may affect the measurement of the beam phase distribution. We have observed significant modification in the measured phase space distribution of a 5–6 mA DC proton beam at the Soreq Applied Research Accelerator Facility low-energy transport after application of a weak magnetic field in the plane of the slit collimator. The periphery region of the phase distribution was mostly affected. The overall effect on the emittance value was as large as 20%.
Electron and X-ray beams originating from compact laser-wakefield accelerators have very small source sizes that are typically on the micrometre scale. Therefore, the beam divergences are relatively high, which makes it difficult to preserve their high quality during transport to applications. To improve on this, tremendous efforts have been invested in controlling the divergence of the electron beams, but no mechanism for generating collimated X-ray beams has yet been demonstrated experimentally. Here we propose and realize a scheme where electron bunches undergoing focusing in a dense, passive plasma lens can emit X-ray pulses with divergences approaching the incoherent limit. Furthermore, compared with conventional betatron emission, the divergence of this so-called plasma lens radiation is reduced by more than an order of magnitude in solid angle, while maintaining a similar number of emitted photons per electron. This X-ray source offers the possibility of producing brilliant and collimated few-femtosecond X-ray pulses for ultra-fast science, in particular for studies based on X-ray diffraction and absorption spectroscopy.
Purpose: We have experimentally characterized and simulated the dosimetric properties and spatial fidelity of a novel X-ray array source and collimation system called SPHINX that has the potential to generate complex intensity modulated X-ray beams by varying the electron beam intensity only, and without any moving parts like in multi-leaf collimators. Methods: We investigated the spatial fidelity and the X-ray performances of a SPHINX prototype in tungsten, using a Cyber Knife and the experimental high-energy electron beam line at XTA at SLAC National Laboratory. Dose distributions were recorded with gafchromic films, placed at the distal end of SPHINX and at several depths in a solid water phantom. The geometry of SPHINX and of the experimental set-ups was also modeled in Monte Carlo (MC) simulations with the FLUKA code, used to reproduce the experimental results and, after validation, to predict and optimize the performance and design of the SPHINX. Results: The results indicate significant particle leakage through the channels during a single-channel irradiation for high incident energies, followed by a rapid decrease for energies of clinical interest. When the collimator channels are used as target, the photon production increases, however at expense of the beam size that is also enlarged. The illumination of all channels simultaneously shows a fairly even transmission of the beam. Conclusion: With the measurements we have verified the MC models and the uniformity of beam transmission through SPHINX, and we have evaluated the importance of particle leakage through adjacent channels. These results can be used to optimize SPHINX design through the validated MC simulations. Funding: Weston Havens Foundation, Office of the Dean of Medical School and Office of the Provost (Stanford University). Loo, Maxim, Borchard, Tantawi are co-founders of TibaRay Inc. Loo and Tantawi are TibaRay Inc. board members. Loo and Maxim received grants from Varian Medical Systems and RaySearch Laboratory.
Electrons from linear accelerator directed in collimated beam at normal incidence upon thick targets of various materials, obtaining energy spectra of retrofugal electrons
We present a nano-scale photoelectron source, optimized for ultrashort pulse durations and well-suited for time-resolved diffraction and advanced laser acceleration experiments. A tungsten tip of several-ten-nanometers diameter mounted in a suppressor-extractor electrode configuration allows the generation of 30 keV electron pulses with an estimated pulse duration of 9 fs (standard deviation; 21 fs full width at half maximum) at the gun exit. We infer the pulse duration from particle tracking simulations, which are in excellent agreement with experimental measurements of the electron-optical properties of the source in the spatial domain. We also demonstrate femtosecond-laser triggered operation of the apparatus. The temporal broadening of the pulse upon propagation to a diffraction sample can be greatly reduced by collimating the beam. Besides the short electron pulse duration, a tip-based source is expected to feature a large transverse coherence and a nanometric emittance.
Purpose We have designed a novel TumoTrak™ x-ray system that delivers 19 distinct kV views with the linac gantry stationary. It images MV treatment beam above and below the patient with a kV tomosysthesis slice image from the therapy beam’s-eye-view. Results will be high quality images without MLC shadowing for notable improvements relative to conventional fluoroscopic MV imaging and fluoroscopic kV imaging. Methods A complete design has a kV electron beam multisource X-ray tube that fits around the MV treatment beam path, with little interference with normal radiotherapy and unblocked by the multi-leaf-collimator. To simulate digital tomosynthesis, we used cone-beam CT projection data from a lung SBRT patient. These data were acquired at 125 kVp and 11 fps (0.4 mAs per projection). We chose 19 projections evenly spaced over 27° around one of the treatment angles (240°). Digital tomosynthesis reconstruction of a slice through the tumor was performed using iterative reconstruction. The visibility of the lesion was assessed for the reconstructed digital tomosynthesis (DTS), using fluoroscopy MV images acquired during radiation therapy, and a kV single projection image acquired at the same angle as the treatment field (240°). Results The fluoroscopic DTS images provide the best tumor contrast, surpassing the conventional radiographic and the in-treatment MV portal images. The electron beam multisource X-ray tube design has been completed and the tube is being fabricated. The estimated time to cycle through all 19 projections is 700 ms, enabling high frame-rate imaging. While the initial proposed use case is for image guided and gated treatment delivery, the enhanced imaging will also deliver superior radiographic images for patient setup. Conclusion The proposed device will deliver high quality planar images from the beam’s-eye-view without MLC obstruction. The prototype has been designed and is being assembled with first imaging scheduled for May 2015. L. Partain, J. Kwon, D. Boyd: NIH/SBIR R43CA192489-01. J. Rottmann, G. Zentai, R. Berbeco: NIH/NCI 1R01CA188446-01. R. Berbeco: E. Research Grant, Varian Medical Systems.
Two-dimensional (2D) materials have extraordinary characteristics that offer promising new approaches for science and technology. Electrons in graphene can move ballistically through a sheet, even though it is only a single atom thick. And transition metal dichalcogenide materials can be cleaved into 2D flakes of all types – metals, semiconductors, insulators, magnetic materials, and superconductors. To benefit from these discoveries, the science needs to be understood to transform 2D materials into useful new devices and systems. The evolution in time of atomic scale graphene structures has been studied in time with a transmission electron microscope (TEM), and ballistic transport of electrons in graphene was been imaged using a cooled scanning probe microscope (SPM), as well as electron motion in MoS 2 . Graphene is only one atom thick but is extremely strong, creating the opportunity to fabricate atomic scale structures in the lateral direction. Using an atomic resolution TEM, a suspended sheet of graphene can be shaped by a Si impurity atom on its surface that acts like a chisel to open up apertures, one atom at a time. The electrons in the TEM provide both the chiseling energy and the ability to image the results. Electrons and holes in graphene form a new type of electronic system with conical conduction and valence bands that meet at the Dirac point, with no energy gap. For moderate densities, the carriers form a Fermi liquid with ballistic transport over micron-scale distances. Using a cooled SPM the cyclotron orbit of electrons in graphene has been imaged. In the magnetic focusing regime, electrons leaving a point contact circle around and leave from a second point contact when the cyclotron diameter is equal to the contact spacing. The paths of electrons are focused - they enter at different angles but converge again at the exiting contact. When the SPM tip knocks an electron out of its orbit, an imaging signal is created. The ballistic motion of carriers in graphene opens the way for ballistic devices that manipulate beams of electrons and holes. Our collaborator Gil-Ho Lee, in Philip Kim's group, created a collimating contact by placing zig-zag absorbers on either side of entering electrons. Our cooled SPM was used to image the electron beam and determine its 9-degree halfwidth. By changing the gate voltage, a collimated beam of holes was also created, opening the way for colliding beam experiments. Coherent beams of carriers are desirable for quantum information processing. Via Andreev reflection, superconducting contacts can covert Cooper pairs in a superconductor to an ingoing and outgoing electrons and holes. Using our cooled SPM, Andreev reflection was imaged from a superconducting contact on a graphene device. Magnetic focusing was used to create an incoming beam of electrons and an outgoing beam of holes, detected by a third point contact. The images show a clear transition from normal reflection above the superconducting transition temperature to Andreev reflection as the device is cooled. Transition metal dichalcogenides offer a wide array of materials that can be exfoliated into ultrathin 2D sheets. A cooled SPM can be used to detect quantum dots as well as to image electron flow. The tip charge capacitively couples to electrons on the dot, acting as a gate to tune the dot conductance. Coulomb blockade peaks appear as a bullseye pattern in an SPM image as the tip is raster scanned above the dot. This approach was used to detect quantum dots in a MoS 2 channel as the carrier density was reduced and electrons pooled in low energy points. Through our DOE supported research, cooled SPM imaging has proven to be a very useful tool to uncover the motion of electrons and holes in the new quantum materials graphene and MoS 2 .
Purpose: To present local control, complications, and cosmetic outcomes of intraoperative radiation therapy (IORT) for early breast cancer, as well as technical aspects related to the use of a nondedicated linear accelerator. Methods and Materials: This prospective trial began in May of 2004. Eligibility criteria were biopsy-proven breast-infiltrating ductal carcinoma, age >40 years, tumor <3 cm, and cN0. Exclusion criteria were in situ or lobular types, multicentricity, skin invasion, any contraindication for surgery and/or radiation therapy, sentinel lymph node involvement, metastasis, or another malignancy. Patients underwent classic quadrantectomy with intraoperative sentinel lymph node and margins evaluation. If both free, the patient was transferred from operative suite to linear accelerator room, and IORT was delivered (21 Gy). Primary endpoint: local recurrence (LR); secondary endpoints: toxicities and aesthetics. Quality assurance involved using a customized shield for chest wall protection, applying procedures to minimize infection caused by patient transportation, and using portal films to check collimator-shield alignment. Results: A total of 152 patients were included, with at least 1 year follow-up. Median age (range) was 58.3 (40-85.4) years, and median follow-up time was 50.7 (12-110.5) months. The likelihood of 5-year local recurrence was 3.7%. There were 3 deaths, 2 of which were cancer related. The Kaplan-Meier 5-year actuarial estimates of overall, disease-free, and local recurrence-free survivals were 97.8%, 92.5%, and 96.3%, respectively. The overall incidences of acute and late toxicities were 12.5% and 29.6%, respectively. Excellent, good, fair, and bad cosmetic results were observed in 76.9%, 15.8%, 4.3%, and 2.8% of patients, respectively. Most treatments were performed with a 5-cm collimator, and in 39.8% of the patients the electron-beam energy used was ≥12 MeV. All patients underwent portal film evaluation, and the shielding was repositioned in 39.9% of cases. No infection or anesthesia complications were observed. Conclusions: Local control with IORT was adequate, with low complication rates and good cosmetic outcomes. More than one-third of patients benefited from the “image-guidance” approach, and almost 40% benefited from the option of higher electron beam energies.