Particle-In-Cell Simulations of High Current Density Electron Beams in the Scorpius Linear Induction Accelerator
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Scorpius is a multipulse linear induction accelerator (LIA) under development for flash radiography. Because it has substantially more cells than present LIAs, higher magnetic focusing fields are needed to suppress beam breakup (BBU). Therefore, it is more susceptible to corkscrew motion of the beam, which also depends on beam energy spread and focusing magnet misalignments. For energy spread and alignment tolerances expected for Scorpius, a magnetic tune designed to suppress BBU is shown to produce corkscrew motion within the range that can be controlled through the use of steering dipoles on existing LIAs. Finally, a gap-voltage modulation scheme is shown to almost completely eliminate chromatic effects such as corkscrew.
Not Available
The development and enhancement of the Electron-Ion Collider (EIC) are founded on extensive research and development efforts aimed at achieving rigorous performance goals. This document outlines the crucial research and development (R&D) efforts that underpin the various systems and components of the EIC, including the polarized electron source and linear accelerator (linac) systems. Achieving the collider’s operational benchmarks relies on meticulously enhancing these components to optimize performance.
Beam position monitors (BPMs) provide timeresolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). The data from some types of BPMs can be influenced by magnetic field diffusion into the surrounding metal. We derive an estimate of the correction factor from first principles, and show how it is applied in practice to nearly eliminate the effect from the data.
To date, linear accelerators (linacs) as electron sources used to produce ionizing radiation for industrial purposes have been limited to less than 100 kW. When the electron beam is used directly, this is sufficient for most potential applications. However, when the electron beam is used for the production of photons (x-rays) which are then to be used in an application, this is not sufficient to compete with other sources of photons (gamma rays from cobalt-60). This paper will discuss acompact superconducting RF (CSRF) accelerator system that relies on emerging technologies that will be able to produce electron beam powers into the 100s of kW with efficiencies much better than present linacs. The focus is to produce x-ray beams for medical device sterilization to provide alternatives for the present use of cobalt-60 for this purpose.
Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements. Although accurate BPM measurements of beam current require correction of magnetic field diffusion, accurate measurement of beam position requires no correction. In this note, we present experimental validation of current and position results from a prototype detector employing finite conductivity sensing areas, based on experiments on the DARHT-II LIA.
Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. From first principles, we have derived the perturbation to BPM measurements due to this effect. The theoretical framework was used to design an algorithm for signal correction that does not require knowledge of the time history of the magnetic flux being measured. Corrected signals based on that process compared favorably with the know reference signals in a laboratory calibration test sequence.
Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). A frequently used BPM detector is the B-dot loop, which generates a signal from the EMF generated by the time varying magnetic flux through the loop. We have developed a second generation BPM that avoids previously observed diffusion effects in earlier stainless steel through the use of exceptionally high conductivity copper alloy for its construction.
Plasma-based acceleration of electrons has produced high-energy beams at high accelerating gradients with a narrow energy spread and high efficiency both in experiments and simulations. Furthermore, it is now being considered as a complementary approach to the use of radiofrequency cavities in next-generation lepton accelerators. However, compared with electrons, plasma-based positron acceleration is at the present time much less advanced. Although high-gradient positron acceleration in a plasma has been achieved, we are one to three orders of magnitude away from delivering the high-quality positron beams needed for a future high-energy linear collider. Here we review the status of plasma-based acceleration of electrons and positrons and discuss the prospects for substantial progress towards developing the positron arm of a plasma-based electron–positron linear collider in the next decade.
Beam position monitors (BPMs) provide time-resolved measurements of the current and centroid position of high-current electron beams in linear induction accelerators (LIAs). One of the types of detectors used in BPMs is the B-dot loop, which generates a signal from the EMF due to the time varying magnetic flux through the loop. If some of the boundaries of the loop are composed of thick metal walls with finite conductivity, the resulting signal must be corrected for the magnetic field diffusion into the metal. The theoretically predicted flux due to diffusion is in remarkable agreement with experimental measurements
Generation and amplification of magnetic fields in plasmas is a long-standing topic that is of great interest to both plasma and space physics. The electron Weibel instability is a well-known mechanism responsible for self-generating magnetic fields in plasmas with temperature anisotropy and has been extensively investigated in both theory and simulations, yet experimental verification of this instability has been challenging. Recently, we demonstrated a new experimental platform that enables controlled initialization of highly nonthermal and/or anisotropic plasma electron velocity distributions via optical-field ionization. Using an external electron probe bunch from a linear accelerator, the onset, saturation, and decay of the self-generated magnetic fields due to electron Weibel instability were measured for the first time to our knowledge. In this paper, we will first present experimental results on time-resolved measurements of the Weibel magnetic fields in non-relativistic plasmas produced by Ti:Sapphire laser pulses (0.8 μm) and then discuss the feasibility of extending the study to a quasi-relativistic regime by using intense CO 2 (e.g., 9.2 μm) lasers to produce much hotter plasmas.
The electron accelerator based Mo-99 production technique requires the use of Rhodotrons to generate 38 MeV, 6.32 mA pulsed electron beams. The introduction of the pulsed beam structure has introduced fatigue concerns in the vacuum-helium windows that did not exist previously for electron beam production via linear accelerators. Previous analysis has shown that temperature fluctuations of approximately 100°C above and below the steady state operating temperature of ~500°C will occur within the windows. A water cooled window will eliminate this concern by reducing the primary mechanical stress due to the 300-psig helium pressure load as well as the secondary thermally induced stress. Although a water cooled window was considered years ago, the complexities of adding an additional water line was unattractive until now. A double wall, water cooled window has been designed and analyzed for this reason. The water cooled window design is shown to decrease the helium-side window temperature to as low as 125°C, while the vacuum-side window is maintained at 161°C at a water flow rate of 3.2 GPM. These low steady state temperatures reduce the thermal stress of the helium-side window significantly. Also, the primary mechanical stress has been reduced by roughly 50% due to the reduced pressure gradient across the helium-side window (150-psig water and 300-psig helium). Considering a Mo-99 production loss of roughly 1%, the water cooled window is a drastic improvement over the previous helium cooled designs and should be greatly considered for future upgrades and redesign.
Electron beam quality is paramount for X-ray pulse production in free-electron-lasers (FELs). State-of-the-art linear accelerators (linacs) can deliver multi-GeV electron beams with sufficient quality for hard X-ray-FELs, albeit requiring km-scale setups, whereas plasma-based accelerators can produce multi-GeV electron beams on metre-scale distances, and begin to reach beam qualities sufficient for EUV FELs. Here we show, that electron beams from plasma photocathodes many orders of magnitude brighter than state-of-the-art can be generated in plasma wakefield accelerators (PWFAs), and then extracted, captured, transported and injected into undulators without significant quality loss. These ultrabright, sub-femtosecond electron beams can drive hard X-FELs near the cold beam limit to generate coherent X-ray pulses of attosecond-Angstrom class, reaching saturation after only 10 metres of undulator. This plasma-X-FEL opens pathways for advanced photon science capabilities, such as unperturbed observation of electronic motion inside atoms at their natural time and length scale, and towards higher photon energies.
Understanding how plasmas thermalize when density gradients are steep remains a fundamental challenge in plasma physics, with direct implications for fusion experiments and astrophysical phenomena. Standard hydrodynamic models break down in these regimes, and kinetic theories make predictions that have never been directly tested. Here, we present the first detailed phase-space measurements of a strongly coupled plasma as it evolves from sharp density gradients to thermal equilibrium. Using laser-induced fluorescence imaging of an ultracold calcium plasma, we track the complete ion distribution function f(x,v,t). We discover that commonly used kinetic models (Bhatnagar–Gross–Krook and Lenard–Bernstein) overpredict thermalization rates, even while correctly capturing the initial counterstreaming plasma formation. Our measurements reveal that the initial ion acceleration response scales linearly with electron temperature, and that the simulations underpredict the initial ion response. In our geometry we demonstrate the formation of well-controlled counterpropagating plasma beams. This experimental platform enables precision tests of kinetic theories and opens new possibilities for studying plasma stopping power and flow-induced instabilities in strongly coupled systems.
The temporal evolution of the magnetic field associated with electron thermal Weibel instability in optical-field ionized plasmas is measured using ultrashort (1.8 ps), relativistic (45 MeV) electron bunches from a linear accelerator. The self-generated magnetic fields are found to self-organize into a quasistatic structure consistent with a helicoid topology within a few picoseconds and such a structure lasts for tens of picoseconds in underdense plasmas. Here, the measured growth rate agrees well with that predicted by the kinetic theory of plasmas taking into account collisions. Magnetic trapping is identified as the dominant saturation mechanism.
An X-ray Free Electron Laser (FEL) prefers using an electron beam with low emittance, small energy spread, and a high core current to generate coherent radiation through an undulator. In order to attain such a high brightness beam, the linear accelerator beam dynamics design generally involves separate photoinjector optimization and linac optimization. In this paper, we propose a new beam dynamics design strategy based on global optimization with fast start-to-end simulations from the photocathode to the end of the accelerator. The new start-to-end model significantly reduces the simulation time and makes the global optimization practical. The global optimization method avoids the need to choose a single solution based on bunch length at the injector exit for the linac optimization and helps find the solution with unfavorable bunch length at the injector exit but better phase space distribution that can result in better final electron beam phase space distribution at the entrance of the undulator. Here, using the start-to-end global optimization, we showed in an application example, with a 100 pC beam that good transverse emittance and over kilo-Ampere final core current can be attained using a photoinjector that consists of a VHF gun and boosting RF cavities.
In this work, we design and demonstrate a compact electron source that combines an integrated silicon nanotip photoemitter with a compact silicon-based electrostatic lens. The lens simultaneously accelerates electrons to 30 keV and focuses the resulting beam to a 0.4 μm (RMS) beam diameter with 62 pm-rad normalized emittance at a distance of 20 mm from the cathode. The compact nature of this lens provides a compelling source for dielectric laser accelerator (DLA) beamlines, ultrafast electron diffraction, or ultrafast electron microscopy. Driven by a 220 fs, 1960 nm pulsed laser beam, electron currents up to 28 electrons/pulse at 100 kHz are demonstrated. The electron bunch length is 540 ± 50 fs for photocurrents of <1 electron/pulse, increasing to 700 ± 80 fs for 28 electrons/pulse, as measured by cross correlation with a 220 fs pulsed laser beam. The maximum 5D peak brightness is measured to be 6.8 × 10 13 A/(m 2 rad 2 ) at 28 electrons/pulse. These results represent a significant step toward developing practical benchtop-sized linear accelerators based on DLA technology or compact ultrafast electron microscopy and diffraction applications.