Search NASA⌕ Search

SEARCH · Search NASA

Results for “Electron spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

2025 ASMS Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS

Title (20 words): Investigation of the Collision-Induced Dissociation Mechanism of Protonated TODGA with IRIS Introduction (120 words): One of the challenges facing wide-spread adoption of nuclear power is the development of efficient separation processes for used nuclear fuel. The molecules in separation processes are subjected to an extreme environment due to the high radiation fields from the used fuel and highly acidic media used for fuel dissolution, which results in significant molecular degradation, leading to reduced process efficiency. These degradation products must be identified and studied so mitigation strategies can be developed to maintain process efficiency. However, complex systems can have many degradation products, complicating identification. Untargeted analysis tools could be used to understand radiation chemistry in complex systems. However, this would necessitate improved understanding of the gas-phase fragmentation mechanisms of fuel cycle molecules like tetraoctyldiglycolamide (TODGA). Methods (120 words): The gas-phase fragmentation of protonated TODGA was investigated using collision-induced dissociation (CID), resonance ejection, and infrared ion spectroscopy (IRIS). CID and resonance ejection experiments were conducted using a Bruker Daltonics (Bremen, Gemany) SolariX XR fourier transform ion cyclotron resonance (FT-ICR) mass spectrometer. IRIS spectra of protonated TODGA and its two CID fragmentation products were measured using a modified Bruker amaZon Speed ETD 3D quadrupole ion trap mass spectrometer coupled to the Free Electron Lasers for Infrared eXperiments (FELIX) free electron laser. Measured spectra were compared with density functional theory (DFT) calculations using the Gaussian 16, Revision C.02 software package with the ?B97X-D functional and def2-TZVPP basis sets. Candidate structures were generated using the CREST 3.0 conformational sampling software tool. Preliminary Data (300 words): Collision-induced dissociation of protonated TODGA ([C36H73N2O3]+, m/z=581.562) results two fragment ions, one at m/z=340.285 assigned as [C20H38NO3]+ and the other at m/z=312.290, assigned as [C19H38NO2]+. Based on the assigned formula and the structure of protonated TODGA, the fragment at m/z=340.285 is likely formed from elimination of neutral dioctylamine. Comparison of the IRIS spectrum of m/z=340.285 with DFT predictions suggests it contains a ring structure, and is assigned as N-octyl-N-(6-oxo-1,4-dioxan-2-ylidene)octan-1-aminium. Based on this structure and the structure of protonated TODGA, we hypothesize this fragment formed from elimination of neutral dioctylamine followed by a ring closure mechanism. Comparison of the IRIS spectrum of the fragment at m/z=312.290 with DFT predictions also indicated the presence of a ring structure, assigned as N-(1,3-dioxolan-4-ylidene)-N-octyloctan-1-aminium. This product could be formed from elimination of carbon monoxide from the ring of m/z=340.285 as a sequential fragmentation or formed directly from protonated TODGA via elimination of neutral N,N-dioctylformamide followed by a ring closure. Resonance ejection experiments where m/z=340 was continuously ejected from the IRC cell showed no decrease in intensity of m/z=312.290 across several collision energies, suggesting that the later, direct formation mechanism, dominates. The location of the ionizing proton in protonated TODGA is important for modeling the fragmentation mechanisms. DFT calculations suggested that the position of bands involving the coupled vibrations of the amide C—N and C=O bonds in TODGA are the most sensitive to proton location. Evaluation of the IRIS spectrum of protonated TODGA suggests that the ionizing proton is located between the two amid oxygens. This protonation location was calculated to lie approximately 30 kJ/mol lower in energy than the next lowest energy location, with the proton located solely on one of the amide oxygens. Novel aspect (20 words): Infrared ion spectroscopy combined with resonance ejection experiments and density functional theory to probe the collision-induced dissociation mechanism of tetraoctyldiglycolamide.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Magnetically collimated relativistic charge-neutral electron–positron beams from high-power lasers

In this work, we report the observation of charge-neutral MeV electron-positron beams from magnetically collimated laser-driven pair-production experiments. Relativistic pairs of electrons were generated from laser-solid interactions in an external 13-T mirror field. The pairs were subsequently confined, deflected or collimated depending on the particle energy and field strength, and measured by a magnetic particle spectrometer. Equal quantities of positrons and electrons were measured in the collimated beams with an energy around 13 MeV along the magnetic mirror axis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Reconstruction of beam parameters and betatron radiation spectra measured with a Compton spectrometer

The photon flux resulting from high-energy electron beam interactions with high-field systems, such as those found in the upcoming FACET-II experiments at the SLAC National Accelerator Laboratory, yields deep insight into the electron beam’s underlying dynamics during the interaction. However, extracting this information is an intricate process. To demonstrate how to approach this challenge using modern methods, this paper utilizes simulated data that models plasma wakefield acceleration-derived betatron radiation in experiments to determine reliable methods of reconstructing key beam and beam-plasma interaction properties. For betatron radiation measurements, translating the observed 200⁢ keV to 30⁢ MeV photon double-differential energy-angle spectra obtained from an advanced Compton spectrometer requires testing multiple methods to optimize the pipeline from its response to incident electron beam information. The paper compares maximum likelihood estimation and machine learning to refine the translation of photon spectra into precise electron beam metrics, such as spot size, energy, and emittance, enhancing the understanding of beam behavior within these dense, high-field environments. We also introduce machine learning and the expected maximization algorithm to reconstruct the primary photon spectrum, employing a multilayer neural network for regression analysis of the energy and angle spectra. With appropriate modifications, the advanced methods reproduce relevant incident beam parameters with high accuracy, even for beam sizes in the <10 μ⁢m range. This capacity is critical to understanding intense beam propagation and its optimization in plasma.

Beam code development & simulation techniques↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

Construction and Commissioning of Gas Electron Multiplier (GEM) Detectors in Advanced Assembly Design for Low-Energy Applications at High Rates and Analysis of GEM Data From the Muse Experiment at PSI

The search beyond the Standard Model explores dark matter and a potential fifth force. DarkLight@ARIEL investigates the dark photon as a mediator between ordinary and dark matter. The experiment aims to measure the process e?Ta ? e?TaX ? e?Ta(e?e+), by detecting a charged lepton pair in the final state. The spectrometers will be instrumented with Gas Electron Multiplier (GEM) detectors with minimal material budget for tracking. A novel GEM construction technique is employed for fabricating 25 cm x 40 cm GEM detectors, where all layers are mechanically stretched and assembled within a double frame. The dissertation outlines physics motivation, methods, experimental setup, and the role of GEM detectors in DarkLight. A comprehensive discussion on GEM detectors, focusing on the "NS2" technique, including design, parts, assembly, testing, and performance evaluation will be discussed. The proton has garnered attention due to discrepancies in measuring its charge radius using muonic hydrogen and electron-based methods. The 2010 muonic hydrogen measurement of the proton charge radius Rp = 0.84184(67) fm, showed a significant 7? discrepancy compared to the previously known value of Rp = 0.8775(51) fm, giving rise to the proton radius puzzle. Through simultaneous measurements of e ? p and ? ? p elastic scattering, MUSE facilitates a precise and direct comparison of the proton radius. The physics background of the proton radius puzzle, measurement techniques, the approach adopted by the MUSE experiment, its significance and the experimental setup will be discussed. Furthermore, the role of GEM detectors, along with an in-depth analysis of their data and efficiency will be discussed and evaluated.

Mohammed Prem Nazeer, Sahara↗

Incoherent Thomson scattering system for PHAse space MApping (PHASMA) experiment

A new incoherent Thomson scattering system measures the evolution of electron velocity distribution functions perpendicular and parallel to the ambient magnetic field during kinking of a single flux rope and merging of two flux ropes through magnetic reconnection. The Thom-son scattering system provides sub-millimeter spatial resolution, sufficient to diagnose the several millimeters sized magnetic reconnection electron diffusion region in the PHAse Space MAppgin experiment. Due to the relatively modest plasma density ~ 10 19 m -3 and electron tem-perature ~1 eV, stray light suppression is critical for these measurements. Two volume Bragg gratings are used in series as a notch filter with a spectral bandwidth <0.1 nm in the collection branch. A CCD with a Gen III intensifier with peak quantum efficiency >47% is used as the detector in a 1.3 m spectrometer. Preliminary results of gun plasma electron temperature will be reported and compared with measurements obtained from a triple Langmuir probe.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A High-Magnetic-Field Polarized 3He Target for JLab's CLAS12 Spectrometer

We are developing a polarized 3He target for use in high luminosity electron scattering experiments within the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping (MEOP) of 3He with cryogenic, double-cell target methods as used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic field environments. We have begun polarizing sealed 3He cells at fields up to 5 T at Jefferson Lab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target. A key focus of our research is the determination of polarization relaxation under the irradiation of an ionizing particle beam within high magnetic fields.

Maxwell, James↗

Absolute calibration of the continuum x-ray spectrometer (ConSpec) at the National Ignition Facility

We illustrate the absolute calibration of the continuum x-ray spectrometer (ConSpec), designed to measure the hot-spot electron temperature of inertial confinement fusion (ICF) implosions at the National Ignition Facility (NIF). The spectrometer measures emission from photon energies of 20 to 30 keV where opacity effects in ICF implosions at the NIF are negligible and provides spatial resolution to separate the hot-spot emission from other x-ray sources, such as the gold emission from the hohlraum wall. Using a combination of x-ray ray tracing and calibration data taken using a well characterized x-ray source, we measure the dispersion, spatial resolution, and absolute sensitivity of the instrument. Finally, we present an example spectrum measured at the NIF and demonstrate the ability to measure the hot-spot electron temperature with uncertainty under 10%.

47 OTHER INSTRUMENTATION↗

Experimental Investigation and Monte Carlo Simulation of Quasielastic Electron Scattering From Helium-3 Clusters in Helium-4

Experiment E04-018 was conducted in Hall A of the Jefferson National Laboratory (JLab) from November 2006 through July 2007. The experiment used the two superconducting, high-resolution magnetic spectrometers of Hall A to detect scattered electrons and recoil nuclei. One goal of this experiment was to provide accurate data on the elastic charge form factor of 4He to high momentum transfers (up to Q2 = 77 fm?2). The purpose of this thesis is to analyze and simulate a very unique and unexpected class of data from this experiment. The work performed involved the analysis of electron scattering data with the 4He target of the JLab E04-018 experiment and Monte Carlo simulation studies of elastic and quasielastic electron scattering from the 4He and 3He few-body nuclear systems. The results of this experiment and the simulations provide insights into the existence of A = 3 clustering in 4He, and possibly in heavier nuclei.

Alahmade, Walaa↗

Single-pixel reconstructive mid-infrared micro-spectrometer

Miniaturized spectrometers in the mid-infrared (MIR) are critical in developing next-generation portable electronics for advanced sensing and analysis. The bulky gratings or detector/filter arrays in conventional micro-spectrometers set a physical limitation to their miniaturization. In this work, we demonstrate a single-pixel MIR micro-spectrometer that reconstructs the sample transmission spectrum by a spectrally dispersed light source instead of spatially grated light beams. The spectrally tunable MIR light source is realized based on the thermal emissivity engineered via the metal-insulator phase transition of vanadium dioxide (VO 2 ). We validate the performance by showing that the transmission spectrum of a magnesium fluoride (MgF 2 ) sample can be computationally reconstructed from sensor responses at varied light source temperatures. With potentially minimum footprint due to the array-free design, our work opens the possibility where compact MIR spectrometers are integrated into portable electronic systems for versatile applications.

47 OTHER INSTRUMENTATION↗

Spectator Proton Detection and Reconstruction in Deep Inelastic D(E,EPS) Scattering

A Radial Time Projection Chamber (RTPC) was designed and installed in Jefferson Lab's Hall B as part of the BONuS12 (Barely Off-shell Nucleon Structure) experiment. The goal of BONuS12 is to accurately measure the structure function of the neutron by scattering 11 GeV electrons and detecting them with the CLAS12 spectrometer. Deuterium gas was used as an effective neutron target, and the new RTPC was used to detect low momentum spectator protons. Protons follow a curved path in the 5 Tesla solenoid that is part of CLAS12, ionizing the He-CO2 gas in an annular drift region surrounding the target. These ionization electrons are radially drifted outwards, amplified using cylindrical GEM (Gaseous Electron Multiplication) foils and recorded using readout pads located along the entire outer face of the cylindrical detector. The particle track reconstruction software discussed in detail in this thesis uses the signals from these pads to build tracks, which are reconstructed into the drift region using the arrival times of the signals and the positions of the pads. The proton momentum is measured from the track?s curvature and thus used to extract information about the struck neutron. This thesis introduces the theory of spectator tagging as an effective strategy for measuring neutron structure, by minimizing nuclear effects in the absence of a free neutron target. Along with discussing the many detectors that make up the CLAS12 spectrometer, the RTPC will be covered in detail, along with the tracking software designed to interpret the electronic signals to rebuild the low-momentum particle tracks, and fit them to extract the relevant kinematics. The results of the software, and preliminary analysis will be shown in the final chapter, as well as the discussion of possible improvements which could be made to the tracking software.

Payette, David↗

Measurements of the Neutron Magnetic Form Factor and the Two-Photon Exchange Contribution to the Electron-Neutron Elastic Scattering Cross Section

The Super BigBite Spectrometer (SBS) program in Experimental Hall A of Jefferson Lab is a series of high-precision, large ?2 , electromagnetic form factor experiments. GMn and nTPE were the first two experiments of the SBS program and ran from Oc?tober 2021 through February 2022. Both experiments detect neutron-tagged ?(?, ???) and proton-tagged ?(?, ???) quasi-elastic electrons scattering from a deuterium tar?get. The GMn experiment is a measurement of the magnetic form factor of the neutron, ?? ?, via the ratio method over a ?2 range of 3.5 to 13.5 (GeV/c)2 . The nTPE experiment ran in-parallel with the GMn experiment and shared an overlap?ping kinematic point with GMn. nTPE extends the GMn experiment to assess the differences between Rosenbluth Slop and the single-photon exchange approximation. The nTPE experiment had two kinematic settings corresponding to different electron scatting angles at a fixed ?2 of 4.5 (GeV/c)? . Comparisons of nucleon form factor ratio measurements acquired through polarization transfer and LT separation reveal discrepancies as ?2 increases. Two-photon exchange is strongly favored as the reason for this discrepancy. ?? ? has been extracted at two kinematic settings corresponding to ?2 values of 3.0 and 4.5 (GeV/c)2 . Additionally, I will present an assessment of the differences between Rosenbluth Separation and single-photon exchange measure?ments.

Boyd III, John Alan↗

EXCLUSIVE NEUTRAL PION ELECTROPRODUCTION CROSS SECTION MEASUREMENTSWITHANEUTRALPARTICLE SPECTROMETER

Deep Virtual Compton Scattering (DVCS), the exclusive electron-proton scattering process ep ¿e'p'¿, provides access to generalized parton distributions (GPDs), which correlate information about the longitudinal momentum and transverse spatial structure of quarks inside the nucleon. Experiment E12-13-010 in Hall C at Jefferson Lab was designed to take high-precision measurements of the DVCS cross section over an extended kinematic range using the newly commissioned Neutral Particle Spectrometer (NPS). The NPS features a high-resolution electromagnetic calorimeter and a streaming data acquisition system optimized for operation at high luminosities. This thesis presents the detector and analysis work carried out to support the NPS DVCS program. In particular, it focuses on the hardware design, calibration, and performance of the calorimeter. A development of a waveform reconstruction analysis of the calorimeter signals enabled improved extraction of pulse amplitudes and times. The waveform analysis was also extended to operate in a multithreaded environment, substantially reducing processing time for large datasets. Analysis of exclusive neutral pion electroproduction events in the calorimeter gives a strong validation of the calorimeter’s performance and resolution. Together these developments establish a foundation for future analyses and extraction of the DVCS cross section and its use in constraining the GPDs.

Kerver, Mitchell [Old Dominion Univ., Norfolk, VA ↗

A High-Magnetic-Field Polarized 3He Target for Jefferson Lab’s CLAS12 Spectrometer

We are developing a polarized 3He target concept for use in high luminosity electron scattering experiments in the high magnetic field environment of Jefferson Lab's CLAS12 spectrometer. By combining recent advancements in metastability exchange optical pumping of 3He with cryogenic, double-cell target methods such as those used for the MIT-Bates 88-02 experiment, a target with polarization and gas density comparable to traditional, low-field polarized 3He targets can be reached within high magnetic fields. We have established a new 3He pumping system at JLab, and are preparing for our first tests exploring polarization performance versus magnetic field and gas pressure in a single cell before we move to the construction of a full, cryogenic, double-cell prototype target.

Maxwell, James↗

A Flat Analyzer Polycapillary Spectrometer for X-ray Absorption Spectroscopy of Dilute Transition Metals at X-ray-Free Electron Lasers

X-ray absorption spectroscopy (XAS) coupled with highly intense pulses from an X-ray-free electron laser (XFEL) can be used to track ultrafast chemical dynamics. Nonetheless, measurements for dilute samples (≤1 mM) have been exceptionally challenging, as scattering background signals dominate over the sample’s X-ray fluorescence. We show that femtosecond time-resolved XAS measurements of sub-millimolar transition metal solutions are now possible at the Linac Coherent Light Source (LCLS) using a high-throughput polycapillary XAS spectrometer, designed, developed, and commissioned at LCLS and the Stanford Synchrotron Radiation Lightsource (SSRL). The instrument integrates three polycapillary optics that collect and collimate X-ray fluorescence emitted from the interaction point with a high solid angle. X-ray collimated fluorescence is then selectively diffracted by coupled graphite analyzer crystals. As a result, the contribution of scattered photons is suppressed. Experiments at the Pt L 3 -edge on 0.1 mM aqueous K 2 PtCl 6 (delivered via a 100 μm liquid jet) were successfully performed in the laser pump X-ray probe configuration at the LCLS XCS and XPP instruments. We report the transient spectra of hexachloroplatinate within the first 10 ps after a 266 nm photoexcitation. We observed a short-lived reduced intermediate (≈2 ps). The polycapillary X-ray spectrometer at LCLS now enables the efficient study of the dynamics of ultradilute transition metals in solution. This capability opens the door to investigating plasmonic systems, photocatalysts, enzymes, and other scarce and dilute samples.

LCLS↗

Improved determination of the 𝛽−‾‾𝜈𝑒 angular correlation coefficient 𝑎 in free neutron decay with the 𝑎⁢SPECT spectrometer

We report on a precise measurement of the electron-antineutrino angular correlation (𝑎 coefficient) in free neutron beta decay from the 𝑎⁢SPECT experiment. The 𝑎 coefficient is inferred from the recoil energy spectrum of the protons which are detected in 4⁢𝜋 by the 𝑎⁢SPECT spectrometer using magnetic adiabatic collimation with an electrostatic filter. Data are presented from a 100-day run at the Institut Laue Langevin in 2013. The sources of systematic errors are considered and included in the final result. We obtain 𝑎=−0.10430⁢(84) which is the most precise measurement of the neutron 𝑎 coefficient to date. From this, the ratio of axial vector to vector coupling constants is derived giving |𝜆|=1.2677⁢(28).

Beck, Marcus↗

Portable diagnostic package for Thomson scattering and optical emission spectroscopy on Princeton field-reversed configuration 2 (PFRC 2)

An Advanced Research Projects Agency-Energy funded diagnostic system has been deployed to the Princeton field-reversed configuration 2 (PFRC-2) device, located at Princeton Plasma Physics Laboratory. The Portable Diagnostic Package (PDP), designed at Oak Ridge National Laboratory, allows for the measurement of Thomson Scattering (TS) for electron density and temperature and Optical Emission Spectroscopy (OES) for ion temperature, impurity density, and ion velocity. A tunable spectrometer on the PDP with three gratings provides the flexibility to measure low (1 eV) and high (1000 eV) electron temperature ranges from TS. Additionally, using a second spectrometer, the OES diagnostic can survey light emission from various ion excitation levels for wide wavelength ranges. The electron density (<2 × 10 19 m –3 ) of plasmas generated in PFRC-2 has been below the PDP TS discrimination threshold, which has made TS signal detection challenging against a high-background of laser stray light. The laser stray light was iteratively reduced by making modifications to the entrance and exit geometry on PFRC-2. Rayleigh scattering experiments on PFRC have yielded the TS discrimination sensitivity to be >1 × 10 20 m –3 for the PDP. A recently implemented narrow-band notch spectral filter that masks the second harmonic 532 nm Nd:YAG laser wavelength has increased the system’s TS light discrimination sensitivity 65 times compared to the instance when the notch filter was not implemented. The hardware implementation including design changes to the flight tubes and Brewster windows will be discussed, along with results from Rayleigh and rotational Raman scattering sensitivity analyses, which were used to establish a quantitative figure of merit on the system performance. Further, the Raman scattering calibration with the notch filter has improved the PDP electron density threshold to 1 ± 0.5 × 10 18 m –3 .

47 OTHER INSTRUMENTATION↗

X-ray Absorption Spectroscopy of Dilute Metalloenzymes at X-ray Free-Electron Lasers in a Shot-by-Shot Mode

X-ray absorption spectroscopy (XAS) of 3d transition metals provides important electronic structure information for many fields. However, X-ray-induced radiation damage under physiological temperature has prevented using this method to study dilute aqueous systems, such as metalloenzymes, as the catalytic reaction proceeds. Here we present a new approach to enable operando XAS of dilute biological samples and demonstrate its feasibility with K-edge XAS spectra from the Mn cluster in photosystem II and the Fe–S centers in photosystem I. This approach combines highly efficient sample delivery strategies and a robust signal normalization method with high-transmission Bragg diffraction-based spectrometers at X-ray free-electron lasers (XFELs) in a damage-free, shot-by-shot mode. These photon-out spectrometers have been optimized for discriminating the metal Mn/Fe Kα fluorescence signals from the overwhelming scattering background present on currently available detectors for XFELs that lack suitable energy discrimination. We quantify the enhanced performance metrics of the spectrometer and discuss its potential applications for acquiring time-resolved XAS spectra of biological samples during their reactions at XFELs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗