Aerosol Wind Profiler (AWP) Doppler Wind Lidar Airborne Observations During the NOAA Joint Venture 3-D Wind Measurement Demonstration and NASA Active-Passive Profiling Experiment (APEX)

The NASA Langley Research Center (LaRC) has recently completed development of the Aerosol Wind Profiler (AWP) airborne Doppler wind lidar (DWL) instrument. AWP was supported by the NASA Earth Science Technology Office and the Earth Science Division, a project that adapted the Wind-Space Pathfinder (Wind-SP) DWL transceiver onto a structure for flight aboard a variety of NASA research aircraft. AWP demonstrates many technologies required for a space DWL mission, including a coherent-detection, optical heterodyne laser transmitter with high pulse energy (up to ~55 mJ) and repetition rate (200 Hz), electronic control of the beam path allowing for multiple viewing angles (allowing vector wind measurements) with no moving parts, compact highly-stable and tunable reference lasers allowing for high-precision measurement of velocity at long ranges while mitigating the impact of satellite platform velocity, and many others. AWP represents NASA’s only currently operational airborne 3-D wind profiling sensor. NASA LaRC was selected by the NOAA Joint Venture (JV) program to conduct a suborbital 3-D Wind measurement campaign demonstrate how data from a coherent-detection DWL like AWP could serve NOAA’s weather analysis and forecasting needs. The NOAA JV program is designed to work with the private sector, academia and other federal agencies to explore the feasibility and capability of emerging technologies spacecraft and other mission-specific tools to meet NOAA’s mission requirements. AWP was initially demonstrated on the NASA DC-8 within this JV program in October 2023, piggybacking on the NASA EcoDemonstrator mission focused on in-situ sampling of jet aircraft emissions and contrail formation from Everett, Washington. The in-situ sampling resulted in very frequent and rapid aircraft attitude changes which unfortunately degraded AWP data quality. But, during times with level flight and AVAPS dropsonde operations, AWP demonstrated excellent precision (< 2 m/s RMS) with high vertical (< 100 meter) resolution and 2 km spacing between profiles. AWP will be flown again on the NASA LaRC Gulfstream-3 from mid-September to mid-October 2024 out of Hampton, VA to complete the NOAA JV 3-D wind demonstration. Additional AWP flights will occur in early November from southern California during the NASA Active-Passive Profiling Experiment (APEX), focused on underflights of the NASA ER-2 equipped with many atmospheric profiling sensors. This presentation will summarize AWP measurements collected during these two fall 2024 flight campaigns, and how the AWP data compares with AVAPS dropsonde, NOAA weather prediction model, and GOES atmospheric motion vector data.

Kristopher Bedka↗

Resolving femtosecond photoinduced energy flow: capture of nonadiabatic reaction pathway topography and wavepacket dynamics from photoexcitation through the conical intersection seam (Final Technical Report)

The dynamics that take place within just tens to hundreds of femtoseconds following the absorption of light by a molecule can play a critical role in how the absorbed energy is directed, allowing it to be used for a specific function or dissipated harmlessly. The form of chemical change that occurs rapidly in these molecules is called a “nonadiabatic electronic transition.” Such transitions are known to mediate energy flow in natural biological systems such as the ultraviolet photoprotection mechanism of DNA and the first step of the human vision response. Understanding how these mechanisms work precisely may help scientists achieve controlled manipulation of solar energy or optical control of a wide range of energy management functions in artificial systems. Experimental methods, however, have not yet allowed a precisely resolved and complete measurement of nonadiabatic electronic transitions. This constitutes a major obstacle to progress in the field. For progress to occur that would inform a wide body of research aiming to efficiently harness the energy of light for practical purposes, it is especially important to benchmark computational models of the molecules undergoing these rapid changes with experimental measurements, in order to learn which models are accurate. With Dept. of Energy funding, we have made strong progress towards establishing a new optical method for experimentally detecting the full nonadiabatic electronic transition. This requires having coordinated pulses of light covering the visible through the mid-infrared range of the electromagnetic spectrum that last only ten femtoseconds. We have developed a new, relatively simple approach for generating such pulses of laser light, and have incorporated them into a time-resolved spectrometer for measuring rapid changes in molecules. These tools can provide the greater precision and new types of data that are needed to benchmark computational models of molecular change and thus to make progress in the field. Our tools were tested on graphene, an excellent solid-state sample for verifying the capabilities and limitations of our instrumentation. The investment made in these tools by the Dept. of Energy Office of Science will allow new fundamental scientific understanding of energy dynamics in molecules in future studies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-Volume Precipitation Spectrometer (HVPS) Instrument Handbook

The high-volume precipitation spectrometer (HVPS) is a U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility instrument for measuring hydrometeors larger than 150 μm. It is an open-path instrument located on the outside of the aircraft, typically below the wing. A laser sheet throws a shadowgraph image of the hydrometeor (cloud droplets or ice crystals) in the sample volume on a photodiode array. As the hydrometeor moves through the sample volume, this optical array records the moving shape and a two-dimensional picture can be recorded. At an air speed of 100 m/s, the sample volume is 310 l/s. The recorded images can be analyzed for size distributions, number concentrations, and further cloud properties detailed below. Hydrometeors in the range of 0.3-19.2 mm can be fully recorded at a 150 μm resolution; larger particles can only be sized along the direction of flight.

54 ENVIRONMENTAL SCIENCES↗

Ex situ calibration of the scattered-light time-history diagnostic on the National Ignition Facility

The scattered-light time-history diagnostic (SLTD) suite measures time-resolved scattered light in three wavelength bands: stimulated Brillouin scattering (350–352 nm), stimulated Raman scattering (430–760 nm), and plasma emission at half the laser frequency (695–735 nm), at 15 locations around the National Ignition Facility (NIF) target chamber. The SLTD, along with the full-aperture backscatter station (FABS), collects scattered light from direct- and indirect-drive inertial confinement fusion experiments. The SLTD calibration was revisited after a discrepancy between FABS and SLTD measurements was observed on NIF polar direct-drive experiments. An integrated calibration of the SLTD was performed for the first time, and individual components were also calibrated for the wavelengths of 351, 527, and 532 nm. The optical transmission of the instrument was measured to be (1.12 ± 0.04) × 10 –7 and (1.96 ± 0.11) × 10 –7 for the wavelengths of 351 and 532 nm, respectively. The revised calibration at 351 nm brings the SLTD measured scattered energy in agreement with the FABS measured scattered energy after additionally accounting for the degradation of an optical element in FABS. Furthermore, this decreased the inferred absorption by 7% for a representative experiment. However, discrepancies remain between FABS and SLTD measurements in the SRS band (532 nm).

47 OTHER INSTRUMENTATION↗

Ytterbium laser system for studying parametric amplification of femtosecond pulses with a centre wavelength of ∼2 μm

A laser system is developed with an optical synchronisation of a femtosecond signal with a pump channel. The signal of a driving ytterbium fibre laser with a 60 MHz repetition rate of stretched femtosecond pulses is amplified in energy from several nanojoules to 0.4 mJ at a pulse repetition rate of 3 kHz in a wideband amplifier and then is compressed in time to 250 fs. The obtained radiation is used for generating femtosecond laser pulses with a centre wavelength of ∼2 μm, pulse energy of above 20 μJ, duration of several field oscillations, and phase stabilisation between the electromagnetic field and envelope. The other pulse of the driving fibre laser provides optical synchronisation and a minimal time delay and is directed to a regenerative Yb : YAG disk amplifier for amplification to an energy of 4 mJ at a pulse repetition rate of 3 kHz and duration of 20 ps. A multipass disk amplifier is developed for further increasing the energy of pump chirped pulses to an energy of 70 mJ at a pulse repetition rate of 10 Hz and duration of 400 ps for studying parametric amplification under sub-nanosecond pumping. (paper)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterizing electron-collecting CdTe for use in a 77 ns burst-rate imager

The Keck-PAD (pixel array detector) was developed at Cornell as a burst-rate imager capable of recording images from successive electron bunches (153 ns period) from the Advanced Photon Source (APS). Both Si and hole-collecting Schottky CdTe have been successfully bonded to this ASIC (application-specific integrated circuit) and used with this frame rate. The facility upgrades at the APS will lower the bunch period to 77 ns, which will require modifications to the Keck-PAD electronics to image properly at this reduced period. In addition, operation at high X-ray energies will require a different sensor material having a shorter charge collection time. For the target energy of 40 keV for this project, simulations have shown that electron-collecting CdTe should allow >90% charge collection within 35 ns. This collection time will be sufficient to sample the signal from one frame and prepare for the next. 750 µm-thick electron-collecting Schottky CdTe has been obtained from Acrorad and bonded to two different charge-integrating ASICs developed at Cornell, the Keck-PAD and the CU-APS-PAD. Carrier mobility has been investigated using the detector response to single X-ray bunches at the Cornell High Energy Synchrotron Source and to a pulsed optical laser. The tests indicate that the collection time will meet the requirements for 77 ns imaging.

36 MATERIALS SCIENCE↗

Laboratory Studies of the Photochemistry of Peroxynitric Acid

Observations of odd hydrogen radicals at high SZA in the lower stratosphere have demonstrated that our understanding of the HO(x) chemistry is incomplete [Wennberg et al., 1994a; Salawitch et al., 1994; Wennberg et al., 1999]. In particular, the concentrations of the HO(x) radicals are significantly larger than expected under weak photolytic conditions. Donaldson et al. [1997] have speculated that excitation of overtones of the OH stretching frequency in molecules such as HNO3 and HO2NO2 may be significant sources of HO(x) under these conditions. Although weak, vibrationally mediated photolysis may be important because it occurs in the near IR and visible and can provide energy in excess of the dissociation energy (D(o)): HONO2 + hv yields OH + NO (D(o) approx. 600 nm) and HOONO2 + hv yields OH + NO3 (D(o) approx. 735 nm) HOONO2 + hv yields HO2 + NO2 (D(o) approx. 1250 nm). In this project we developed instrumentation to characterize the photodissociation yields of hydroxyl containing compounds in the visible and near IR. This effort has involved coupling a tunable photolysis optical parametric oscillator (OPO) laser system with precise determination of the hydroxyl radical. The OPO system [Wu et al., 1997] was developed with support from the NSF Major Research Instrumentation Fund in a proposal entitled "Development of Novel, Compact Light Sources for Advanced Spectroscopy in Atmospheric Science and Materials Research" (Geoffrey A. Blake, P.I. California Institute of Technology).

Wennberg, Paul O.↗

YAG aerosol lidar

The Global Atmospheric Backscatter Experiment (GLOBE) Mission, using the NASA DC-8 aircraft platform, is designed to provide the magnitude and statistical distribution of atmospheric backscatter cross section at lidar operating wavelengths. This is a fundamental parameter required for the Doppler lidar proposed to be used on a spacecraft platform for global wind field measurements. The prime measurements will be made by a CO2 lidar instrument in the 9 to 10 micron range. These measurements will be complemented with the Goddard YAG Aerosol Lidar (YAL) data in two wavelengths, 0.532 and 1.06 micron, in the visible and near-infrared. The YAL, is being designed to utilize as much existing hardware, as feasible, to minimize cost and reduce implementation time. The laser, energy monitor, telescope and detector package will be mounted on an optical breadboard. The optical breadboard is mounted through isolation mounts between two low boy racks. The detector package will utilize a photomultiplier tube for the 0.532 micron channel and a silicon avalanche photo detector (APD) for the 1.06 micron channel.

Sullivan, R.↗

Optical Test Bench (SYSM 5620 Final Report)

The National Ignition Facility (NIF) is a research facility that focuses on High Energy Density Science and Inertial Confinement Fusion. In the NIF, 192 laser beams are directed into a miniscule Target Capsule to generate an implosion – this is called a NIF Shot. Many NIF Users conduct experiments using different Targets and laser inputs to generate reactions that are of interest to the scientific community. Those reactions are monitored using various Target Diagnostic instruments, including Shot Time Photography – which provides crucial images of the Target as the implosion occurs. A subset of these NIF Users is less interested in the reaction itself and more interested in subjecting materials or devices to the intense environment that these reactions can create. Using the Target as a source of x-rays, neutrons, or blast loading for particular materials has been significant to the shock physics community and to those who work in extreme design spaces. However, the Material and Radiation Effects team – that performs these experiments on behalf of the NIF Users – has not been able to make good use of the existing Shot Time Photography Diagnostics. The STP cameras are focused on the Targets rather than the MRE Customers’ materials, the current system is not oriented to have a good view of the MRE Customers’ materials, and the cameras are limited in their capabilities (black and white, poor resolution, etc.). As MRE experiments increase in quantity and importance to the scientific community, the desire for visual monitoring of the experiments to substantiate models and inform other data is also rising.

42 ENGINEERING↗

Imaging grain microstructure in a model ceramic energy material with optically generated coherent acoustic phonons

Characterization of microstructure, chemistry and function of advanced energy materials remains a challenge for instrumentation science with tremendous opportunity for new discoveries. This active area of research is starting to make considerable strides with examples ranging from methodologies that employ bright X-rays, electron microscopy and optical spectroscopy. However, further development of instruments, capable of multimodal measurements, is necessary to fully reveal complex microstructure evolution in realistic environments and dynamical systems that are far from equilibrium. In this regard, laser-based instruments have a unique advantage as multiple measurement methodologies are easily combined into a single instrument using standard optics. A new pump-probe method that uses optically generated acoustic phonons is expanding standard optical characterization by providing depth resolved information. Here we report on a noteworthy extension of this pump-probe method to image grain microstructure in ceria. Rich information regarding the orientation of individual crystallites is obtained by monitoring acoustic phonon velocities and noting how the polarization of the probe beam influences the detected signal amplitude. When paired with other optical microscopies, this methodology will provide new perspectives for optical characterization of ceramic materials.

36 MATERIALS SCIENCE↗

The Geoscience Laser Altimeter System (GLAS) for the ICESAT Mission

The Laser In space Technology Experiment, Shuttle Laser Altimeter and the Mars Observer Laser Altimeter have demonstrated accurate measurements of atmospheric backscatter and Surface heights from space. The recent MOLA measurements of the Mars surface have 40 cm vertical resolution and have reduced the global uncertainty in Mars topography from a few km to about 5 m. The Geoscience Laser Altimeter System (GLAS) is a next generation lidar for Earth orbit being developed as part of NASA's Icesat Mission. The GLAS design combines a 10 cm precision surface lidar with a sensitive dual wavelength cloud and aerosol lidar. GLAS will precisely measure the heights of the Earth's polar ice sheets, establish a grid of accurate height profiles of the Earth's land topography, and profile the vertical backscatter of clouds and aerosols on a global scale. GLAS is being developed to fly on a small dedicated spacecraft in a polar orbit with a 590 630 km altitude at inclination of 94 degrees. GLAS is scheduled to launch in the summer 2001 and to operate continuously for a minimum of 3 years with a goal of 5 years. The primary mission for GLAS is to measure the seasonal and annual changes in the heights of the Greenland and Antarctic ice sheets. GLAS will continuously measure the vertical distance from orbit to the Earth's surface with 1064 nm pulses from a ND:YAG laser at a 40 Hz rate. Each 5 nsec wide laser pulse is used to produce a single range measurement, and the laser spots have 66 m diameter and about 170 m center-center spacings. When over land GLAS will profile the heights of the topography and vegetation. The GLAS receiver uses a 1 m diameter telescope and a Si APD detector. The detector signal is sampled by an all digital receiver which records each surface echo waveform with I nsec resolution and a stored echo record lengths of either 200, 400, or 600 samples. Analysis of the echo waveforms within the instrument permits discrimination between cloud and surface echoes. Ground based echo analysis permits precise ranging, determining the roughness or slopes of the surface as well as the vertical distributions of vegetation illuminated by the laser. Accurate knowledge of the laser beam's pointing angle is needed to prevent height biases when over sloped surfaces. For surfaces with 2 deg. slopes, knowledge of pointing angle of the beam's centroid to about 8 urad is needed to achieve 10 cm height accuracy. GLAS uses a stellar reference system (SRS) to determine the pointing angle of each laser firing relative to inertial space. The SRS uses a high precision star camera oriented toward local zenith and a gyroscope to determine the inertial orientation of the SRS optical bench. The far field pattern of each laser is measured pulse relative to the star camera with a laser reference system (LRS). Optically measuring each laser far field pattern relative to the orientation of the star camera and gyroscope permits the precise pointing angle of each laser pulse to be determined. GLAS will also determine the vertical distributions of clouds and aerosols by measuring the vertical profile of laser energy backscattered by the atmosphere at both 1064 and 532 nm. The 1064 nm measurements use the Si APD detector and profile the height and vertical structure of thicker clouds. The measurements at 532 nm use new highly sensitive photon counting, detectors, and measure the height distributions of very thin Clouds and aerosol layers. With averaging these can be used to determine the height of the planetary boundary layer. The instrument design and expected performance will be discussed.

Abshire, James B.↗

Broadband sum-frequency generation of spectrally incoherent pulses

We study and demonstrate the nonlinear frequency conversion of broadband optical pulses from 1053 nm to 351 nm using sum-frequency generation with a narrowband pulse at 526.5 nm. The combination of angular dispersion and noncollinearity cancels out the wave-vector mismatch and its frequency derivative, yielding an order-of-magnitude increase in spectral acceptance compared to conventional tripling. This scheme can support the nonlinear frequency conversion of broadband spectrally incoherent nanosecond pulses generated by high-energy lasers and optical parametric amplifiers to mitigate laser−plasma instabilities occurring during interaction with a target. The experimental results obtained with KDP crystals are in excellent agreement with modeling, demonstrating the generation of spectrally incoherent pulses with a bandwidth larger than 10 THz at 351 nm.

47 OTHER INSTRUMENTATION↗

Spectral and temporal shaping of spectrally incoherent pulses in the infrared and ultraviolet

Laser–plasma instabilities (LPIs) hinder the interaction of high-energy laser pulses with targets. Simulations show that broadband spectrally incoherent pulses can mitigate these instabilities. Optimizing laser operation and target interaction requires controlling the properties of these optical pulses. We demonstrate closed-loop control of the spectral density and pulse shape of nanosecond spectrally incoherent pulses after optical parametric amplification in the infrared (∼1053 nm) and sum–frequency generation to the ultraviolet (∼351 nm) using spectral and temporal modulation in the fiber front end. The high versatility of the demonstrated approaches can support the generation of high-energy, spectrally incoherent pulses by future laser facilities for improved LPI mitigation.

47 OTHER INSTRUMENTATION↗

Entropy-mode-driven gas optics

We propose a class of gaseous diffractive optical elements created by imprinting an entropy mode in a gas. Previous approaches to gaseous diffractive optics have relied on the simultaneous excitation of a standing acoustic wave and an entropy mode to produce one-dimensional periodic structures. However, the presence of acoustic oscillations in the gas imposes stringent constraints on some of the operational parameters of these optical elements, such as their lifetime and diffraction angle. Here, in this work, we introduce an approach that eliminates the acoustic mode, relying solely on the entropy mode. This enables control of the lifetime and temporal profile of gaseous optical elements, and also allows the creation of arbitrary structures with greater contrast, including nonperiodic patterns such as chirped gratings or lenses. This approach should allow operation over a wider parameter space, including larger diffraction angles and compatibility with laser pulse durations ranging from femtoseconds to microseconds.

Optics and optical instruments↗

Linewidth narrowing in self-injection-locked on-chip lasers

Abstract Stable laser emission with narrow linewidth is of critical importance in many applications, including coherent communications, LIDAR, and remote sensing. In this work, the physics underlying spectral narrowing of self-injection-locked on-chip lasers to Hz-level lasing linewidth is investigated using a composite-cavity structure. Heterogeneously integrated III–V/SiN lasers operating with quantum-dot and quantum-well active regions are analyzed with a focus on the effects of carrier quantum confinement. The intrinsic differences are associated with gain saturation and carrier-induced refractive index, which are directly connected with 0- and 2-dimensional carrier densities of states. Results from parametric studies are presented for tradeoffs involved with tailoring the linewidth, output power, and injection current for different device configurations. Though both quantum-well and quantum-dot devices show similar linewidth-narrowing capabilities, the former emits at a higher optical power in the self-injection-locked state, while the latter is more energy-efficient. Lastly, a multi-objective optimization analysis is provided to optimize the operation and design parameters. For the quantum-well laser, minimizing the number of quantum-well layers is found to decrease the threshold current without significantly reducing the output power. For the quantum-dot laser, increasing the quantum-dot layers or density in each layer increases the output power without significantly increasing the threshold current. These findings serve to guide more detailed parametric studies to produce timely results for engineering design.

47 OTHER INSTRUMENTATION↗

Production of high fluence laser beams using ion wave plasma optics

Optical components for laser beams with high peak and averaged powers are being developed worldwide using stimulated plasma scattering that occurs when plasmas interact with intense, coherent light. After decades of pursuit of pulse compressors, mirrors, and other plasma based components that can be created by stimulated scattering from electron density perturbations forming on ultra-short time scales (e.g., via Stimulated Raman Scattering), more recent work has produced optical components on longer time scales allowing ion motion as well [via Stimulated Brillouin Scattering (SBS)]. In the most recent work, ion wave plasma optics have had success in producing pulses of focusable coherent light with high energy and fluence by operating on ns time scales and now promise to enable numerous applications. Experiments have further shown that in some parameter regimes, even simple plasma response models can describe the output of such optics with sufficient accuracy that they can be used as engineering tools to design plasma optics for future applications, as is already being done to control power deposition in fusion targets. In addition, the development of more sophisticated models promises to enable still higher performance from SBS driven plasma optical components under a wider range of conditions. The present status and most promising directions for future development of ion wave plasma optic techniques are discussed here.

47 OTHER INSTRUMENTATION↗

Collective optical Thomson scattering in pulsed-power driven high energy density physics experiments (invited)

Optical collective Thomson scattering is used to diagnose magnetized high energy density physics experiments at the Magpie pulsed-power generator at Imperial College London. The system uses an amplified pulse from the 2nd harmonic of a Nd:YAG laser (3 J, 8 ns, 532 nm) to probe a wide diversity of hightemperature plasma objects; with densities in the range of 10 17 -10 19 cm -3 and temperatures between 10 eV and a few keV. The scattered light is collected from 100 μm-scale volumes within the plasmas, which are imaged onto optical fiber arrays. Multiple collection systems observe these volumes from different directions, providing simultaneous probing with different scattering K-vectors (and different associated α-parameters, typically in the range 0.5 – 3) allowing independent measurements of separate velocity components of the bulk plasma flow. The fiber arrays are coupled to an imaging spectrometer with a gated ICCD. The spectrometer is configured to view the ion-acoustic waves (IAWs) of the collective Thomson scattered spectrum. Fits to the spectra with the theoretical spectral density function S(K,ω) yield measurements of the local plasma temperatures and velocities. Fitting is constrained by independent measurements of the electron density from laser interferometry, and the corresponding spectra for different scattering vectors. Furthermore, this TS diagnostic has been successfully implemented on a wide range of experiments, revealing temperature and flow velocity transitions across magnetized shocks, inside rotating plasma jets and imploding wire arrays, as well as providing direct measurements of drift velocities inside a magnetic reconnection current sheet.

47 OTHER INSTRUMENTATION↗

Population inversion X-ray laser oscillator

Oscillators are at the heart of optical lasers, providing stable, transform-limited pulses. Until now, laser oscillators have been available only in the infrared to visible and near-ultraviolet (UV) spectral region. In this paper, we present a study of an oscillator operating in the 5- to 12-keV photon-energy range. We show that, using the Kα 1 line of transition metal compounds as the gain medium, an X-ray free-electron laser as a periodic pump, and a Bragg crystal optical cavity, it is possible to build X-ray oscillators producing intense, fully coherent, transform-limited pulses. As an example, we consider the case of a copper nitrate gain medium generating ~ 5 × 10 10 photons per pulse with 37-fs pulse length and 48-meV spectral resolution at 8-keV photon energy. Our theoretical study and simulation of this system show that, because of the very large gain per pass, the oscillator saturates and reaches full coherence in four to six optical-cavity transits. We discuss the feasibility and design of the X-ray optical cavity and other parts of the oscillator needed for its realization, opening the way to extend X-ray–based research beyond current capabilities.