Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Energy management - The delayed flap approach

Flight test evaluation of a Delayed Flap approach procedure intended to provide reductions in noise and fuel consumption is underway using the NASA CV-990 test aircraft. Approach is initiated at a high airspeed (240 kt) and in a drag configuration that allows for low thrust. The aircraft is flown along the conventional ILS glide slope. A Fast/Slow message display signals the pilot when to extend approach flaps, landing gear, and land flaps. Implementation of the procedure in commercial service may require the addition of a DME navigation aid co-located with the ILS glide slope transmitter. The Delayed Flap approach saves 250 lb of fuel over the Reduced Flap approach, with a 95 EPNdB noise contour only 43% as large.

Bull, J. S.↗

Advanced thermal energy management: A thermal test bed and heat pipe simulation

Work initiated on a common-module thermal test simulation was continued, and a second project on heat pipe simulation was begun. The test bed, constructed from surplus Skylab equipment, was modeled and solved for various thermal load and flow conditions. Low thermal load caused the radiator fluid, Coolanol 25, to thicken due to its temperature avoided by using a regenerator-heat-exchanger. Other possible solutions modeled include a radiator heater and shunting heat from the central thermal bus to the radiator. Also, module air temperature can become excessive with high avionics load. A second preoject concerning advanced heat pipe concepts was initiated. A program was written which calculates fluid physical properties, liquid and vapor pressure in the evaporator and condenser, fluid flow rates, and thermal flux. The program is directed to evaluating newer heat pipe wicks and geometries, especially water in an artery surrounded by six vapor channels. Effects of temperature, groove and slot dimensions, and wick properties are reported.

Barile, Ronald G.↗

What Can We Learn From Resilient Pilot Behaviors? The Case of Energy Management While Flying a Star

Recently, there has been increased interest in documenting flightcrew behaviors that contribute to safe operations. Instead of only capturing errors, new efforts are attempting to understand how pilots manage complexity and variability in the operational environment to ensure a safe mission. This approach highlights pilot responses to events and conditions that fall outside typical TEM threats; e.g., revised ATC clearances. This approach presents a two-sided coin: characterize flightcrew resilience /or/ generate insights regarding complexity in the operational environment that is not adequately managed by current flight deck interface designs, procedures, and training. To capture operational complexity, we have been analyzing flight path management tied to flying an RNAV STAR. Because ATC often requests revisions—e.g., descend late—and because RNAV STARs may not align with airplane performance limits, flightcrews need to monitor, anticipate threats to RNAV STAR compliance, and devise ways to accommodate unexpected challenges. In this paper, we identify general strategies that can support response adaptation and explore methods to facilitate training these strategies.

flight operations↗

Energy and Water Management

Energy efficiency isn't just a good idea; it's a necessity, both for cost reasons and to meet federal regulatory requirements. First, rising energy unit costs continue to erode NASA's mission budget. NASA spent roughly $156M on facility energy in FY 2007. Although that represents less than one per cent of NASA's overall annual budget, the upward trend in energy costs concerns the agency. While NASA reduced consumption 13%, energy unit costs have risen 63%. Energy cost increases counteract the effects of energy conservation, which results in NASA buying less yet spending more. The second factor is federal energy legislation. The National Energy Conservation Policy Act, as amended by the Energy Policy Act of 2005, Executive Order (EO) 13423 (January, 2007), and the Energy Independence and Security Act (December, 2007), mandates energy/water conservation goals for all federal agencies, including NASA. There are also reporting requirements associated with this legislation. The Energy/Water Management Task was created to support NASA Headquarters Environmental Management Division (HO EMD) in meeting these requirements. With assistance from TEERM, HQ EMD compiled and submitted the NASA Annual Report to the Department of Energy FY 2007. The report contains information on how NASA is meeting federally mandated energy and water management goals. TEERM monitored input for timeliness, errors, and conformity to the new energy/water reporting guidelines and helped compile the information into the final report. TEERM also assists NASA Energy/Water Management with proposal and award calls, updates to the energy/water management database, and facilitating communication within the energy/water management community. TEERM is also supporting NASA and the Interagency Working Group (IWG) on Hydrogen and Fuel Cells. Established shortly after the President announced the Hydrogen Fuel Initiative in 2003, this IWG serves as the mechanism for collaboration among the Federal agencies involved in hydrogen-related research, development, and demonstration. TEERM developed a matrix showing all Hydrogen and Fuel Cell activities from the various NASA centers to be included in the Group's extensive hydrogen research taxonomy of past, present, and future hydrogen activities of the Federal government.

Valek, Susan E.↗

Electric load management and energy conservation

Electric load management and energy conservation relate heavily to the major problems facing power industry at present. The three basic modes of energy conservation are identified as demand reduction, increased efficiency and substitution for scarce fuels. Direct and indirect load management objectives are to reduce peak loads and have future growth in electricity requirements in such a manner to cause more of it to fall off the system's peak. In this paper, an overview of proposed and implemented load management options is presented. Research opportunities exist for the evaluation of socio-economic impacts of energy conservation and load management schemes specially on the electric power industry itself.

Kheir, N. A.↗

SPS Energy Conversion Power Management Workshop

Energy technology concerning photovoltaic conversion, solar thermal conversion systems, and electrical power distribution processing is discussed. The manufacturing processes involving solar cells and solar array production are summarized. Resource issues concerning gallium arsenides and silicon alternatives are reported. Collector structures for solar construction are described and estimates in their service life, failure rates, and capabilities are presented. Theories of advanced thermal power cycles are summarized. Power distribution system configurations and processing components are presented.

Source record↗

Electric power processing, distribution, management and energy storage

Power distribution subsystems are required for three elements of the SPS program: (1) orbiting satellite, (2) ground rectenna, and (3) Electric Orbiting Transfer Vehicle (EOTV). Power distribution subsystems receive electrical power from the energy conversion subsystem and provide the power busses rotary power transfer devices, switchgear, power processing, energy storage, and power management required to deliver control, high voltage plasma interactions, electric thruster interactions, and spacecraft charging of the SPS and the EOTV are also included as part of the power distribution subsystem design.

Giudici, R. J.↗

Hybrid-Electric Aero-Propulsion Controls Testbed Results

NASA is supporting the development of Electrified Aircraft Propulsion (EAP) technology due to its potential to reduce aircraft fuel burn, emissions, and noise as well as improving safety and performance. One focus of this research is the electrification of conventional turbomachinery propulsion systems, which offers ways to improve the performance and operability of turbine-engine powered aircraft through the addition of electro-mechanical systems. These hybrid-electric turbine engines provide additional actuation and energy management control opportunities for improving stability and transient response behavior. This paper summarizes the results of a Hardware-in-the-Loop (HIL) test performed at the NASA Electric Aircraft Testbed (NEAT) during the summer of 2022. The test demonstrates the feasibility and performance of an advanced energy management control strategy by integrating a simulated turbofan engine with scaled electro-mechanical hardware. A full-scale real-time reference model of a geared turbofan was run alongside a scaled electro-mechanical system representing the electrified turbofan components operating at a megawatt-scale power level. The model was interfaced with the hardware through a novel closed-loop control and scaling algorithm that emulated the dynamic speed and torque response of the turbofan shafts. The control strategy was implemented on the electrical machines connected to the emulated turbomachinery shafts. The results from the testbed are compared against simulations that predict the testbed and geared turbofan model operation. The energy management control strategy successfully changed the operating point of the engine model and improved its stability during throttle transients. These results also demonstrate the success of the novel closed loop control and scaling approach for emulating turbomachinery and elevate the Technology Readiness Level (TRL) of the energy management control strategy.

Aeronautics↗