Search NASA⌕ Search

SEARCH · Search NASA

Results for “Energy usage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Industrial Locomotive Inventory Analysis

Due to their captive and local operations, industrial locomotives present a unique potential to reduce energy consumption and associated costs through application of advanced locomotive technologies. However, until now, there has been no data source for the number, size (hp), usage, and energy consumption of these locomotives, which limits the ability to design and implement a research, development, and deployment strategy. This research addresses this gap by developing the first national inventory of locomotives in industrial use and provides a tool to explore the energy and emissions associated with this transportation segment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

3D printing of packaging inserts from biomass-fungi composites: Environmental sustainability analysis

In this study, a comprehensive Life cycle assessment (LCA) is conducted on molded packaging inserts from expanded polystyrene (EPS) foam, molded packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the low mix / high volume (LMHV) scenario and molded and machined packaging inserts from EPS foam, molded and machined packaging inserts from biomass-fungi composite, and 3D-printed packaging inserts from biomass-fungi composite under the high mix / low volume (HMLV) scenario. Six environmental impact categories—climate change, acidification, eutrophication, fossil resource scarcity, land use, and water consumption—are analyzed to evaluate the environmental trade-offs associated with each type of packaging inserts. Under the LMHV scenario, molded packaging inserts from biomass-fungi composite emerge as the best option due to their lower impact on climate change, acidification and water consumption compared to other types of packaging inserts. Conversely, molded packaging inserts from biomass-fungi composite face challenges in land use and eutrophication, primarily due to raw material production. LCA also reveals that 3D-printed packaging inserts from biomass-fungi composite are the most environmentally favorable option under the HMLV scenario, due to significantly lower contributions to climate change, eutrophication, and water consumption compared to other types of packaging inserts. Conversely, 3D-printed packaging inserts from biomass-fungi composite face challenges in acidification and land use, primarily due to raw material production. As part of the LCA, sensitivity analyses show that sourcing energy from 100% renewable sources substantially lowers climate change impacts across all packaging types, while varying transportation distances results in only minor changes, indicating the dominant role of upstream material and manufacturing processes. Additional sensitivity analysis is conducted under the HMLV scenario to assess the impact of material removal during machining on the environment. The amount of material removal is varied from 10 to 70% for the sensitivity analysis and it highlights that the amount of material removed during machining has no significant impact on climate change for packaging inserts from EPS foam. However, molded and machined packaging inserts from biomass-fungi composite show an increasing trend in climate change with higher amount of material removal, while 3D-printed packaging inserts from biomass-fungi composite exhibit a decreasing trend, driven by reduced raw material usage and energy consumption.

09 BIOMASS FUELS↗

LIB Design Module for Grid Energy System Application

We will employ a machine learning approach with intelligent data mining and database construction to analyze enormous data repositories for identifying and extracting geographic-dependent cell design specifications from publicly accessible grid-scale energy storage usage databases in an automated way at scale.

Liu, Dianying [Pacific Northwest National Laborato↗

Distributed Wind for Commercial Loads

Distributed wind can help meet on site energy and resilience needs for a wide variety of commercial loads .While it is a variable resource, it has predictable daily and annual production trends. The presence of on-site renewable generation can enhance resilience, supplying power for long periods of time without worrying about conserving fuel supply. The addition of properly sized storage or complementary solar resources can further reduce the challenges of intermittency and reduce the need for fuel-limited backup power during outage situations. This fact sheet explores further the energy and resilience requirements of commercial loads and how distributed wind may be a good match to meet their load needs.

20 FOSSIL-FUELED POWER PLANTS↗

A Fast Dynamic Internal Predictive Power Scheduling Approach for Power Management in Microgrids: Preprint

This paper presents a Dynamic Internal Predictive Power Scheduling (DIPPS) approach for optimizing power management in microgrids, particularly focusing on external power exchanges among diverse prosumers. DIPPS utilizes a dynamic objective function with a time-varying binary parameter to control the timing of power transfers to the external grid, facilitated by efficient usage of energy storage for surplus renewable power. The microgrid power scheduling problem is modeled as a mixed-integer nonlinear programming (MINLP-PS) and subsequently transformed into a mixed-integer linear programming (MILPPS) optimization through McCormick's relaxation to reduce computational complexity. A predictive window window with 6 data points is solved at an average of 0.92s, a 97.6% improvement over the 38.27s required for the MINLP-PS formulation, implying the numerical feasibility of the DIPPS approach for real-time implementation. Finally, the approach is validated against a static objective using real-world load data across three case studies with different time-varying parameters, demonstrating the ability of DIPPS to optimize power exchanges and efficiently utilize distributed resources while shifting the external power transfers to specified time durations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

NLR HPC Facility Power Usage Effectiveness (PUE) Data

Timeseries of Energy Systems Integration Facility (ESIF) Data Center Power Usage Effectiveness (PUE) Data provided in Parquet and compressed CSV formats Power Metrics Timeseries Fields: ts: Timestamp cooling_kw: Cooling (kilowatts) - Captures the power used by fans and pipe trace heaters associated with outdoor cooling equipment. The dedicated tower filter pump power is also captured as cooling load. energy_reuse: Energy Reuse Effectiveness hvac_kw: Heating, ventilation, and air conditioning (kilowatts) - Captures fan walls, fan coils that support the data center electrical rooms, and the make-up air unit. it_power_kw: IT equipment (kilowatts) - Captures power used by the IT equipment on the data center floor. plug_and_light_kw: Lights and utility plugs (kilowatts) - Captures power associated with the data center and dedicated mechanical room. The crank-case heater for the emergency standby generator is also captured as light and plug load. pue: Power Usage Effectiveness pump_kw: Pumps (kilowatts) - Captures power from pumps that move water in the data center Energy Recover Water loop and the Tower Water loops, and also captures power used by the boost pumps that circulate water through the fan walls. Note: The tower filter pump runs constantly to filter water from the data center cooling tower system, so 2.67 kilowatts are attributed to this pump and that is not reflected in this data field. day: Day of month Outside Weather Station Timeseries Fields: ts: Timestamp outside_air_humidity: Outside air humidity - Relative humidity percent outside_air_temp: Outside air temperature - Degrees Fahrenheit day: Day of month More detail: High-Performance Computing Data Center Power Usage Effectiveness

97 MATHEMATICS AND COMPUTING↗

Investigation of Nonflammable Electrolytes for Behind-the-Meter Storage Batteries

Behind-the-Meter Storage (BTMS) is a battery-based, stationary energy storage system that is connected to the residential or industrial customer's side of the electrical grid utility service meter. BTMS systems enable consumers to (A) economically schedule charging and usage of stored energy, (B) store and use energy from on-site generation, especially from inconstant, renewable sources like solar and wind, and (C) avoid overloading the grid during peak hours via supplementation with stored energy. BTMS battery performance requirements and general priorities differentiate from other applications, like EVs, which has prompted the development of batteries with tailored electrode and electrolyte materials. These materials prioritize low cost, avoiding critical materials; longevity, achieving 8000 cycle and 20-year shelf lives; and importantly, high safety. Nonflammable electrolytes show promise to improve safety by mitigating thermal runaway, yet often come with sacrifices to battery performance. In this presentation (1) primary categories of nonflammable electrolytes will be discussed; (2) a rational design of experiment will be presented for efficient performance evaluation of several nonflammables electrolyte in BTMS-relevant battery chemistry, Li4Ti5O12- and LiNi0.90Mn0.10O2; and (3) preliminary results will be presented.

battery↗

Solar Panel Installation at Goucher College

As part of our multi-phased sustainability initiative, Goucher College is implementing a series of necessary changes to become a model “green” campus. This comprehensive approach includes implementing systems designed to reduce energy consumption, water usage, and waste production by 2030. The first phase of this holistic endeavor is to develop two independent solar projects. One will be on the Facility Management Services building (FMS) and the other will be on the Central Utility Plan (CUP). The anticipated duration of this project is expected to be 24 months. When completed, the new photovoltaic panels (PVPs) and resulting solar array system will help offset campus energy consumption. The projects will also help the College achieve its goal of working towards operating primarily on renewable energy. During initial review of the project, it was revealed replacing the roofs prior to installing new PVPs would not only provide a sound structural foundation for the projects, but the new roofing systems will also aid de-carbonization. The project’s scope is divided between two buildings. Building A: FMS is the first building and Building B: CUP is the second building.

14 SOLAR ENERGY↗

Electrochemical Cycling of Liquid Organic Hydrogen Carriers as a Sustainable Approach for Hydrogen Storage and Transportation

Hydrogen (H 2 ), as a high-energy-density molecule, offers a clean solution to carry energy. However, the high diffusivity and low volumetric density of H 2 pose a challenge for long-term storage and transportation. Liquid organic hydrogen carriers (LOHCs) have been suggested as a strategic way to store and transport hydrogen in stable molecules. More so, electrochemical LOHC cycling renders an opportunity to utilize renewable energy for hydrogen storage and transportation toward the goal of eliminating carbon emissions. In this Perspective, examples of electrochemical reactions of organic molecules and their suitability for LOHC couples are examined. A comparative carbon footprint assessment of electrochemical LOHC cycling processes against thermochemical and hybrid LOHC cycling processes was performed. The electrochemical LOHC cycling process had the lowest relative carbon footprint only when highly concentrated LOHCs were used as the feed or when purification of the LOHC product was not required. The carbon footprint in electrochemical cycling of diluted LOHC was primarily contributed to by the LOHC distillation separation process. A sensitivity analysis showed the carbon footprint LOHC concentration dependence during the electrochemical cycling process. Moreover, the electrolyte composition significantly affects the carbon footprint during electrochemical LOHC cycling. Energy utilization, water usage, and toxicity for electrochemical LOHC cycling are discussed to provide an overview for better economic and environmental practices. There are significant opportunities in the electrochemical cycling of LOHCs if appropriate conditions such as high concentrations of reactant, reversible redox cycling ability, high Faradaic efficiencies, and catalyst stabilities are achieved.

25 ENERGY STORAGE↗

North America’s Potential for an Environmentally Sustainable Nickel, Manganese, and Cobalt Battery Value Chain

The Detroit Big Three General Motors (GMs), Ford, and Stellantis predict that electric vehicle (EV) sales will comprise 40–50% of the annual vehicle sales by 2030. Among the key components of LIBs, the LiNixMnyCo1−x−yO2 cathode, which comprises nickel, manganese, and cobalt (NMC) in various stoichiometric ratios, is widely used in EV batteries. This review reveals NMC cathodes from laboratory research. Furthermore, this study examines the environmental effect of NMC cathode production for EV batteries (including coating technologies), encompassing aspects such as energy consumption, water usage, and air emissions. Although gaps persist in NMC cathode environmental assessments (NMC111, NMC532, NMC622, and NMC811), limited life cycle assessments “(LCA)” have been conducted. Most available data originate from Asia (primarily China), accounting for 85% of the production of EV LIB cathode materials. The concept of battery passports for data collection on LIB components has been proposed to facilitate material traceability as a system for ensuring a sustainable supply chain for critical minerals. The automotive industry’s shift to electrification necessitates a sustainable supply chain from mine to vehicle end-of-life. As the critical mineral supply moves from Asia to North America, environmentally friendly industrial methods must be studied to provide this supply chain direction.

25 ENERGY STORAGE↗

Computationally efficient models for aqueous organic redox flow batteries

The rising usage of intermittent energy has garnered the need for large scale energy storage systems. Redox flow batteries (RFB) based energy storage system shows promising potential. Numerical simulations and machine learning approaches have been widely used to study RFB performance. The development of autonomous material discovery framework and digital twin of energy storage system usually needs to query cell performance through fast response models. In this study, two computationally efficient models are introduced: a physics-based analytical flow battery model (EZBattery), and a machine learning operator model (Deep Operator Network, denoted by DeepONet). Both models can provide cell performance near instantly, and prediction accuracy was systematically examined on an application of evaluating the performances of a 780 cm 2 aqueous organic redox flow battery (AORFB), using potential anolyte candidates in dihydroxyphenazine (DHP)-based family of organic materials. A validated computationally expansive 3-dimensional multi-physics finite element model by COMSOL was used as the ground truth and provided the training data set for the DeepONet. 1280 samples were generated with 10 properties to mimic the different possible anolyte candidates, and the cell performances were evaluated under 10 different combined operating conditions. The accuracy comparisons for the two computationally efficient models show that both models can provide comparable accuracy in predicting cell charging/discharging voltage curves. DeepONet can provide slightly higher overall accuracy than EZBattery with faster calculation speed, but highly relies on the training dataset. EZBattery does not need a training dataset and can provide interpretable physics-based explanations of the results, while being more flexible to adjust to adapt any different cell designs, flow battery architectures, and electrolyte materials.

Analytical model↗

Where to cool off: a geospatial framework for placement of cooling centers

Indoor cooling is essential to reduce heat stress and increase passive survivability during heatwaves. Although air conditioning (AC) is recommended for maintaining indoor thermal comfort, low- and medium-income households in the U.S. often do not own an AC and/or limit AC usage to reduce energy consumption and associated costs, thereby risking their health and safety. With the frequency and intensity of heatwaves increasing, cooling centers are considered an appropriate alternative to indoor cooling and a possible mitigation strategy to prevent adverse health impacts of heat exposure. However, these centers are limited in numbers and not always accessible. This requires (i) developing a geospatial framework using physical and social factors for optimal siting of cooling centers to meet future needs and (ii) ranking of existing and potential cooling centers (schools, libraries, religious institutions) based on their accessibility among vulnerable populations and proximity to healthcare facilities. We developed and deployed a geospatial framework based on the Multi-criteria Decision Analysis approach in five U.S. cities (Los Angeles (LA), Phoenix, Austin, Atlanta, Miami) to evaluate the effectiveness of the framework in ranking cooling centers based on accessibility and population coverage. The results revealed that (i) access to cooling centers varies across cities and 32.2–50.7% of centers are within walking distance of the most vulnerable populations, (ii) vulnerable populations exposed to Urban Heat Island (UHI) effects are more likely to experience energy burden, and (iii) about 21.2–49.4% of population with high energy burden have access to these centers. Considering that more cooling centers are needed to assist energy burdened households alleviate heat exposure impacts, the framework developed herein could be adapted to incorporate other factors (e.g. health impacts, policies) to assess site suitability of existing shelters, identify potential sites for new cooling centers, and geo-target communities where energy efficient emerging technologies could be deployed to reduce heat stress.

58 GEOSCIENCES↗

Avian Activity Classification Using Recurrent Networks to Fuse Videos with Metadata on Imbalanced Datasets

Activity classification plays a crucial role in various real-life scenarios involving both humans and animals. There is an increasing need for precise activity classification focused on avian-solar interactions, as the usage of solar energy facilities, such as photovoltaic array power stations, has been observed to impact bird species richness, behavior, and activity. However, there has been no work to develop an automated system to monitor and classify these avian-solar interactions. All current methods rely on human observers, which is time and human resources costly and subject to errors related to searcher efficiency. With the recent success of Deep Learning models in activity classification problems, this paper develops a recurrent neural network-based model to automatically classify six avian activities around solar energy facilities. Our proposed model integrates critical feature engineering metadata with video frame data, enabling improved learning and more accurate activity classification. Furthermore, we address the challenge of data imbalance during training and demonstrate the efficacy of our model in detecting and classifying different activities within video tracks. Additionally, we analyze the saliency/backpropagation map of the trained proposed model and validate its decision-making rationale.

Avian activity classification; bidirectional LSTM;↗

High Pressure DME-Driven Fractional Crystallizations

Rare Earth Elements (REEs), include the 15 lanthanides plus yttrium and scandium and are crucial for various technologies and applications. Their low concentrations in the earth's crust require alternative sources. This study explores antisolvent fractional crystallization (FC) using dimethyl ether (DME) under high pressures to extract REEs from secondary sources such as mining waste, coal byproducts, and e-waste. DME's properties, including its solubility in water, small molecular size, and high vapor pressure, make it an effective antisolvent that can be easily recovered and reused. The method involves pressurizing DME to 1000-2000 psi in a reaction chamber with the test solution, followed by sample collection and analysis using ICP-MS and ICP-OES. This approach aims to address the limitations of current extraction methods, such as high energy consumption, chemical usage, and waste production, offering a potentially more efficient and sustainable solution for REE extraction.

37 - INORGANIC, ORGANIC, PHYSICAL AND ANALYTICAL C↗

Event-Based Energy Impact Tracking and Forecasting with Limited Measurements for Rooftop Units

Packaged air conditioning units and heat pumps, also known as rooftop units (RTUs), are responsible for almost 133 billion kWh of electricity usage annually on site for space cooling U.S. commercial buildings. In addition, the use of heat pumps is a trend we expect to accelerate as buildings transition from fossil fuel-based heating to electricity as a key step for decarbonizing the U.S. commercial buildings sector. However, the operation conditions and energy use of RTUs and heat pumps are usually not well monitored as they are not commonly integrated with building automation systems and lack exposed sensing and control points. To fill this gap, this paper proposes a framework for tracking and forecasting energy impacts resulting from degradation of performance and improved performance for unit servicing using limited data. The proposed framework makes use of a constrained dataset, specifically measurements of the outdoor air temperature and the power demand of individual RTUs, to track and forecast changes in energy use associated with changes in performance over various temporal horizons ranging from days to weeks. Following the detection of an RTU fault, performance degradation, or performance improvement, the framework employs a prediction model to assess the cumulative energy impact. We demonstrate the effectiveness of the method with field-collected data for servicing and degradation examples and compare the predicting accuracy of Gradient Boosting Decision Tree (GBDT) Regression models to Support Vector Regression and Linear Regression models. The results show that GBDT achieved the best accuracy for time-series validation datasets for the servicing and degradation cases, and the prediction model was able to track the cumulative energy impacts of events. The proposed framework can inform building owners of the cumulative change in energy usage of RTUs associated with performance degradation, performance improvement, or a fault.

packaged air conditioners, packaged heat pumps, ro↗

EVs@Scale Next-Gen Profiles - Fleet Utilization 2024

As part of the U.S. Department of Energy’s EVs@Scale initiative, the Next-Gen Profiles (NGP) project provides a comprehensive, data-driven analysis of electric vehicle (EV) and electric vehicle supply equipment (EVSE) operations across real-world fleet deployments. This paper presents findings from the NGP’s Fleet Utilization study, which investigates operational behavior and asset usage across seventeen EV fleets and two EVSE fleets, encompassing a wide range of vehicle types and use cases. Data collected from diverse sources—varying in format and temporal resolution—are first reformatted into a unified structure. From this harmonized dataset, a suite of rigorously defined performance metrics is calculated at an hourly cadence, enabling consistent cross-comparison of charging, routing, and other key operational behaviors. Amid rapidly increasing EV adoption and growing demands for energy-efficient fleet operations, the analysis reveals clear utilization trends—including diurnal and weekly activity cycles, differences in short versus long charging session dependencies, and route-specific energy usage patterns. These findings highlight the need for tailored infrastructure strategies and the deployment of advanced energy management systems, such as Distributed Energy Resource Management Systems (DERMS) and Site Energy Management Systems (SEMS), which can optimize charging schedules and mitigate peak loads. By leveraging anonymized, harmonized datasets and standardized metrics, this study offers critical insights into fleet behavior and performance, providing a foundation to improve operational efficiency, reduce costs, and enable the scalable deployment of electrified transportation.

Wells, Landon↗