Search NASA⌕ Search

SEARCH · Search NASA

Results for “Enhanced Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comprehensive Non-Destructive Conservation Documentation of Lunar Samples Using High-Resolution Image-Based 3D Reconstructions and X-Ray CT Data

Established contemporary conservation methods within the fields of Natural and Cultural Heritage encourage an interdisciplinary approach to preservation of heritage material (both tangible and intangible) that holds "Outstanding Universal Value" for our global community. NASA's lunar samples were acquired from the moon for the primary purpose of intensive scientific investigation. These samples, however, also invoke cultural significance, as evidenced by the millions of people per year that visit lunar displays in museums and heritage centers around the world. Being both scientifically and culturally significant, the lunar samples require a unique conservation approach. Government mandate dictates that NASA's Astromaterials Acquisition and Curation Office develop and maintain protocols for "documentation, preservation, preparation and distribution of samples for research, education and public outreach" for both current and future collections of astromaterials. Documentation, considered the first stage within the conservation methodology, has evolved many new techniques since curation protocols for the lunar samples were first implemented, and the development of new documentation strategies for current and future astromaterials is beneficial to keeping curation protocols up to date. We have developed and tested a comprehensive non-destructive documentation technique using high-resolution image-based 3D reconstruction and X-ray CT (XCT) data in order to create interactive 3D models of lunar samples that would ultimately be served to both researchers and the public. These data enhance preliminary scientific investigations including targeted sample requests, and also provide a new visual platform for the public to experience and interact with the lunar samples. We intend to serve these data as they are acquired on NASA's Astromaterials Acquisistion and Curation website at http://curator.jsc.nasa.gov/. Providing 3D interior and exterior documentation of astromaterial samples addresses the increasing demands for accessability to data and contemporary techniques for documentation, which can be realized for both current collections as well as future sample return missions.

Blumenfeld, E. H.↗

Enhancement of X-ray performance with new GEC charged coupled devices (CCD)

Samples of two GEC charge coupled devices with enhanced X-ray performance have been tested. The P8607, fabricated with reduced linear dimensions, gives the lowest detector noise reported for Fe-55 with a CCD. The deep depletion device P8600-HR gives the best combination of energy resolution and quantum efficiency at 6 keV. The energy resolution vs quantum efficiency trade-off curve are discussed.

Schwartz, D. A.↗

Comparison of the Results of MISSE 6 Atomic Oxygen Erosion Yields of Layered Kapton H Films with Monte Carlo Computational Predictions

A space experiment flown as part of the Materials International Space Station Experiment 6B (MISSE 6B) was designed to compare the atomic oxygen erosion yield (Ey) of layers of Kapton H polyimide with no spacers between layers with that of layers of Kapton H with spacers between layers. The results were compared to a solid Kapton H (DuPont, Wilmington, DE) sample. Monte Carlo computational modeling was performed to optimize atomic oxygen interaction parameter values to match the results of both the MISSE 6B multilayer experiment and the undercut erosion profile from a crack defect in an aluminized Kapton H sample flown on the Long Duration Exposure Facility (LDEF). The Monte Carlo modeling produced credible agreement with space results of increased Ey for all samples with spacers as well as predicting the space-observed enhancement in erosion near the edges of samples due to scattering from the beveled edges of the sample holders.

Oxygen atoms↗

Isotopic composition of the anomalous low energy cosmic ray nitrogen and oxygen

The isotopic composition of the enhanced fluxes of cosmic ray nitrogen and oxygen observed below 30 MeV/nuc is of interest, whether the nuclei are a sample from some nearby galactic source region that is underabundant in carbon, or a sample of the neutral interstellar medium. Enhanced fluxes in the 6 to 12 MeV/nuc energy interval were measured over a two year period with the Caltech Electron/Isotope Spectrometer on IMP-7. The observed low-energy nitrogen and oxygen nuclei are predominantly N-14 and O-16, with upper limits (84% confidence level) of N-15/N below 0.26, O-17/0 below 0.13, and O-18/0 below 0.12 for other isotopes in the 6-12 MeV/nuc energy interval. The implications of these results for the origin of the enhanced nitrogen and oxygen fluxes are discussed.

Mewaldt, R. A.↗

Investigation of spectral analysis techniques for randomly sampled velocimetry data

It is well known that velocimetry (LV) generates individual realization velocity data that are randomly or unevenly sampled in time. Spectral analysis of such data to obtain the turbulence spectra, and hence turbulence scales information, requires special techniques. The 'slotting' technique of Mayo et al, also described by Roberts and Ajmani, and the 'Direct Transform' method of Gaster and Roberts are well known in the LV community. The slotting technique is faster than the direct transform method in computation. There are practical limitations, however, as to how a high frequency and accurate estimate can be made for a given mean sampling rate. These high frequency estimates are important in obtaining the microscale information of turbulence structure. It was found from previous studies that reliable spectral estimates can be made up to about the mean sampling frequency (mean data rate) or less. If the data were evenly samples, the frequency range would be half the sampling frequency (i.e. up to Nyquist frequency); otherwise, aliasing problem would occur. The mean data rate and the sample size (total number of points) basically limit the frequency range. Also, there are large variabilities or errors associated with the high frequency estimates from randomly sampled signals. Roberts and Ajmani proposed certain pre-filtering techniques to reduce these variabilities, but at the cost of low frequency estimates. The prefiltering acts as a high-pass filter. Further, Shapiro and Silverman showed theoretically that, for Poisson sampled signals, it is possible to obtain alias-free spectral estimates far beyond the mean sampling frequency. But the question is, how far? During his tenure under 1993 NASA-ASEE Summer Faculty Fellowship Program, the author investigated from his studies on the spectral analysis techniques for randomly sampled signals that the spectral estimates can be enhanced or improved up to about 4-5 times the mean sampling frequency by using a suitable prefiltering technique. But, this increased bandwidth comes at the cost of the lower frequency estimates. The studies further showed that large data sets of the order of 100,000 points, or more, high data rates, and Poisson sampling are very crucial for obtaining reliable spectral estimates from randomly sampled data, such as LV data. Some of the results of the current study are presented.

Sree, Dave↗

Rugged, Portable, Real-Time Optical Gaseous Analyzer for Hydrogen Fluoride

Hydrogen fluoride (HF) is a primary evolved combustion product of fluorinated and perfluorinated hydrocarbons. HF is produced during combustion by the presence of impurities and hydrogen- containing polymers including polyimides. This effect is especially dangerous in closed occupied volumes like spacecraft and submarines. In these systems, combinations of perfluorinated hydrocarbons and polyimides are used for insulating wiring. HF is both highly toxic and short-lived in closed environments due to its reactivity. The high reactivity also makes HF sampling problematic. An infrared optical sensor can detect promptly evolving HF with minimal sampling requirements, while providing both high sensitivity and high specificity. A rugged optical path length enhancement architecture enables both high HF sensitivity and rapid environmental sampling with minimal gaseous contact with the low-reactivity sensor surfaces. The inert optical sample cell, combined with infrared semiconductor lasers, is joined with an analog and digital electronic control architecture that allows for ruggedness and compactness. The combination provides both portability and battery operation on a simple camcorder battery for up to eight hours. Optical detection of gaseous HF is confounded by the need for rapid sampling with minimal contact between the sensor and the environmental sample. A sensor is required that must simultaneously provide the required sub-parts-permillion detection limits, but with the high specificity and selectivity expected of optical absorption techniques. It should also be rugged and compact for compatibility with operation onboard spacecraft and submarines. A new optical cell has been developed for which environmental sampling is accomplished by simply traversing the few mm-thick cell walls into an open volume where the measurement is made. A small, low-power fan or vacuum pump may be used to push or pull the gaseous sample into the sample volume for a response time of a few seconds. The optical cell simultaneously provides for an enhanced optical interaction path length between the environmental sample and the infrared laser. Further, the optical cell itself is comprised of inert materials that render it immune to attack by HF. In some cases, the sensor may be configured so that the optoelectronic devices themselves are protected and isolated from HF by the optical cell. The optical sample cell is combined with custom-developed analog and digital control electronics that provide rugged, compact operation on a platform that can run on a camcorder battery. The sensor is inert with respect to acidic gases like HF, while providing the required sensitivity, selectivity, and response time. Certain types of combustion events evolve copious amounts of HF, very little of other gases typically associated with combustion (e.g., carbon monoxide), and very low levels of aerosols and particulates (which confound traditional smoke detectors). The new sensor platform could warn occupants early enough to take the necessary countermeasures.

Pilgrim, Jeffrey↗

New directions for nanoscale thermoelectric materials research

Many of the recent advances in enhancing the thermoelectric figure of merit are linked to nanoscale phenomena with both bulk samples containing nanoscale constituents and nanoscale materials exhibiting enhanced thermoelectric performance in their own right. Prior theoretical and experimental proof of principle studies on isolated quantum well and quantum wire samples have now evolved into studies on bulk samples containing nanostructured constituents. In this review, nanostructural composites are shown to exhibit nanostructures and properties that show promise for thermoelectric applications. A review of some of the results obtained to date are presented.

thermoelectric materials↗

Atomic Force Microscope Mediated Chromatography

The atomic force microscope (AFM) is used to inject a sample, provide shear-driven liquid flow over a functionalized substrate, and detect separated components. This is demonstrated using lipophilic dyes and normal phase chromatography. A significant reduction in both size and separation time scales is achieved with a 25-micron-length column scale, and one-second separation times. The approach has general applications to trace chemical and microfluidic analysis. The AFM is now a common tool for ultra-microscopy and nanotechnology. It has also been demonstrated to provide a number of microfluidic functions necessary for miniaturized chromatography. These include injection of sub-femtoliter samples, fluidic switching, and sheardriven pumping. The AFM probe tip can be used to selectively remove surface layers for subsequent microchemical analysis using infrared and tip-enhanced Raman spectroscopy. With its ability to image individual atoms, the AFM is a remarkably sensitive detector that can be used to detect separated components. These diverse functional components of microfluidic manipulation have been combined in this work to demonstrate AFM mediated chromatography. AFM mediated chromatography uses channel-less, shear-driven pumping. This is demonstrated with a thin, aluminum oxide substrate and a non-polar solvent system to separate a mixture of lipophilic dyes. In conventional chromatographic terms, this is analogous to thin-layer chromatography using normal phase alumina substrate with sheardriven pumping provided by the AFM tip-cantilever mechanism. The AFM detection of separated components is accomplished by exploiting the variation in the localized friction of the separated components. The AFM tip-cantilever provides the mechanism for producing shear-induced flows and rapid pumping. Shear-driven chromatography (SDC) is a relatively new concept that overcomes the speed and miniaturization limitations of conventional liquid chromatography. SDC is based on a sliding plate system, consisting of two flat surfaces, one of which has a recessed channel. A fluid flow is produced by axially sliding one plate past another, where the fluid has mechanical shear forces imposed at each point along the channel length. The shear-induced flow rates are very reproducible, and do not have pressure or voltage gradient limitations. SDC opens up a new range of enhanced separation kinetics by permitting the sample confinement with submicron dimensions. Small, highly confined liquid is advantageous for chromatographic separation because the separation rate is known to scale according to the square of the confined sample diameter. In addition, because shear-driven flows are not limited by fluid velocity, shear-driven liquid chromatography may provide up to 100,000 plate efficiency.

Anderson, Mark S.↗

IRAS observations of an optically selected sample of interacting galaxies

IRAS observations of a large, morphologically selected sample of strongly interacting disk-type galaxies have demonstrated that galaxy-galaxy collisions can lead to enhanced infrared emission, but not in all cases. Infrared luminosities of the interacting galaxies span a large range, but are about a factor of 2 higher, on average, than those of isolated disk galaxies. The data suggest the existence of a cutoff in blue luminosity, below which no galaxies show markedly enhanced infrared emission. Only the most strongly interacting systems in the sample show extreme values of infrared excess, suggesting that deep, interpenetrating collisions are necessary to drive infrared emission to extreme levels. Comparisons with optical indicators of star formation show that infrared excess and color temperatures correlate with the level of star-formation activity in the interacting galaxies. All interacting galaxies in our sample that exhibit an infrared excess and have higher than normal color temperatures also have optical indicators of high levels of star formation. It is not necessary to invoke processes other than star formation to account for the enhanced infrared luminosity in this sample of interacting galaxies.

Bushouse, Howard A.↗

Ammonia 15N/14N Isotope Ratio in the Jovian Atmosphere

Data from the Galileo Probe Mass Spectrometer has been used to derive the N-15/N-14 isotope ratio in ammonia at Jupiter. Although the mass spectral interference from the water contribution to 18 amu makes an accurate derivation of the (N-15)H3/(N-14)H3 ratio difficult from measurements of the singly ionized signals at 18 and 17 amu, this interference is not present in the doubly charged 8.5 and 9.0 amu signals from (N-14)H3++ and (N-15)H3++ respectively. Although the count rate from the 9 amu signal is low during the direct sampling of the atmosphere, the ammonia signal was considerably enhanced during the first enrichment cell (EC1) experiment that measured gas sampled between 0.8 and 2.8 bar. Count rates at 9 amu in the EC1 experiment reach 60/second and measure ammonia sampled from 0.88 to 2.8 bar. In the EC1 measurements the 8.5 amu signal is not measured directly, but can be calculated from the ammonia contribution to 17 amu and the ratio of NH3 ions of a double to single charged observed during a high resolution mass scan taken near the end of the descent. The high resolution scan gives this ratio from ammonia sampled much deeper in the atmosphere. These results are described and compared with Infrared Space Observatory-Short Wavelength Spectrometer (ISO-SWS) observations that give this ratio at 400 mbar.

Mahaffy, P.R.↗

Method for Processing Lunar Regolith Using Microwaves

A paper describes a method of using microwave heating experiments on lunar simulants to determine the mechanism that causes lunar regolith to be such an excellent microwave absorber. The experiments initially compared the effects of sharp particle edges to round particle edges on the heating curves. For most compositions, sharp particle edged samples were more effective in being heated by microwaves than round particle edged materials. However, the experiments also showed an unexpected effect for both types of particles. Upon heating the sample surface above 400 C, the sample experienced some sort of internal structure change that caused it to heat much more efficiently. This enhancement may be associated with the unique microwave volumetric heating that can produce a large temperature gradient within the sample leading to melting of some components at the center of the sample. This new effect that may also be happening in lunar regolith samples is probably the cause of the previously observed enhanced heating of a sample of lunar regolith. Properly designed microwave applicators could heat and solidify the lunar regolith to form roads and building blocks for structures needed on the Moon

Barmatz, Martin B.↗

Volatile products from the interaction of KCl(g) with Cr2O3 and LaCrO3 in oxidizing environments

Cooled target collection techniques and high pressure mass spectrometric sampling were used to measure the relative rates of oxidative vaporization and to identify the volatile products emanating from samples of chromia and Mg-doped lanthanum chromite. The materials were exposed to partial pressures of KCl with and without H2O in one atmosphere of slowly flowing oxygen at elevated temperatures. Chromia and fresh samples of lanthanum chromite exhibited enhanced rates of oxidative vaporization upon exposure to these reactants. Mass spectrometric identification showed that the enhancements resulted from the heterogeneous formation of complex molecules of the type KCl sub 1,2,3 CrO3 and KOH sub l,2 CrO3. Lanthanum chromite that had undergone prolonged oxidative vaporization exhibited no enhanced oxidation upon exposure to the reactants.

Kohl, F. J.↗

Environmental data display

Methods for using a combination of computer-generated color graphics and image processing techniques to display a large data base of environment information are described. The data source can be either field data or mathematical models, reduced to summary statistics that characterize the data field as a whole. Sharp gradients are plotted into contour plots, which can also feature shades, degree of brightness, and saturation levels for fine-tuning the image. The basic concepts of digital image processing are reviewed, including location of the pixels, intensity mapping operations, pseudocolor enhancements, neighborhood averaging, and smoothing. Sample applications are presented in terms of emissions and air quality distributions over the south coast air basin of southern California.

Hussey, K. J.↗

Macromolecular assemblies in reduced gravity environments

The assembly of protein macro molecules into structures commonly produced within biological systems was achieved using in vitro techniques carried out in nominal as well as reduced gravity environments. Appropriate hardware was designed and fabricated to support such studies. Experimental protocols were matched to the available reduced gravity test opportunities. In evaluations of tubulin, fibrin and collagen assembly products the influence of differing gravity test conditions are apparent. Product homogeneity and organization were characteristic enhancements documented in reduced gravity samples. These differences can be related to the fluid flow conditions that exist during in vitro product formation. Reduced gravity environments may provide a robust opportunity for directing the products formed in a variety of bioprocessing applications.

Moos, Philip J.↗

Solar particle abundances at energies of greater than 1 MeV per nucleon and the role of interplanetary shocks

The abundances of elements in large solar energetic-particle events in the energy range of 2-12 MeV per nucleon are examined. It is confirmed that the abundances relative to mean values vary approximately monotonically as a function of mass, except for He-4; some events show a gradual depletion of heavy ions, whereas a small number displays a gradual increase. A further organization of abundance data is shown, which depends on the longitude of the source region. Enhancements in Fe/C and other heavy elements relative to C occur when source regions are near west 60 deg; the enhancements are attributed to the sampling of a flare-heated material. Depletions of these elements are found to be greatest for source regions near central meridian; they are matched by a steepening of the spectrum and can be understood in terms of diffusive shock acceleration.

Cane, H. V.↗

Distances to diffuse interstellar clouds from IRAS measurements and observations of optical absorption lines

Distances to diffuse interstellar clouds were determined from the amount of ultraviolet radiation that penetrates into the cloud and that arises from a nearby B star. The environment around 67 Ophiuchi, 20 Aquilae, kappa Aquilae, and 9 Cephei were studied. The intensities at 60 and 100 micron, as measured by IRAS, were used to derive dust temperatures for the clouds. Enhanced dust temperatures would indicate an influence of the star's radiation field on a cloud. Observation of molecular absorption were compared to the results of simplified chemical models in order to search for enhanced photodissociation that is caused by the star. Enhanced dust temperatures were observed for clouds in the vicinities of 20 Aql, kappa Agl, and 9 Cep. The range of the star's influence was found to be typically 1-5 pc. On the other hand, chemical analyses of the molecular data, which pertain to foreground gas, did not reveal the presence of enhanced dissociative flux from the sample of stars. Thus, upper limits were derived for the distances from the sun to the foreground material.

Federman, S. R.↗

Mechanisms for the Crystallization of ZBLAN

A number of research teams have observed that glass forming melts that are solidified in low-g exhibit enhanced glass formation. This project will examine one of these glasses, the heavy metal fluoride glass ZBLAN. A four year ground based research program has been approved to examine the crystallization of ZBLAN glasses with the purpose of testing a theory for the crystallization of ZBLAN glass. The theory could explain the general observations of enhanced glass formation of other glasses melted and solidified in low-g. Fluid flow in 1-g results from buoyancy forces and surface tension driven convection. This fluid flow can introduce shear in undercooled liquids in 1-g. In low-g it is known that fluid flows are greatly reduced so that the shear rate in fluids in low-g are extremely low. It is believed that fluids may have some weak structure in the absence of flow. Even very small shear rates could cause this structure to collapse in response to the shear. A general result would be shear thinning of the fluid. The hypothesis of this research is that: Shear thinning in undercooled liquids increases the rate of nucleation and crystallization of glass forming melts. Shear of the melt can be reduced in low-g enhancing undercooling and glass formation. Samples will be melted and quenched in 1-g under quiescent conditions at a number of controlled cooling rates to determine times and temperatures of crystallization and heated at controlled heating rates to determine kinetic crystallization parameters. Experiments will also be performed on the materials while under controlled vibration conditions and compared with the quiescent experiments in order to evaluate the effect of shear in the liquid on crystallization kinetics. After the experimental parameters are well known, experiments will be repeated under low-g (and 2-g) conditions on the KC-135 aircraft during low-g parabolic maneuvers. The results will determine the effects of shear on crystallization. Our experimental setups will be designed with low-g experiments in mind and will be tested as breadboard low-g experiments. It is very likely that the thermal analysis instrumentation can be adapted to be run in the microgravity glovebox facilities. Critical space experiments may result to test the theory at longer low-g time experiments in space.

Ethridge, Edwin C.↗

Hydrocarbon-Fueled Rocket Plume Measurement Using Polarized UV Raman Spectroscopy

The influence of pressure upon the signal strength and polarization properties of UV Raman signals has been investigated experimentally up to pressures of 165 psia (11 atm). No significant influence of pressure upon the Raman scattering cross section or depolarization ratio of the N2 Raman signal was found. The Raman scattering signal varied linearly with pressure for the 300 K N2 samples examined, thus showing no enhancement of cross section with increasing pressure. However at the highest pressures associated with rocket engine combustion, there could be an increase in the Raman scattering cross section, based upon others' previous work at higher pressures than those examined in this work. The influence of pressure upon thick fused silica windows, used in the NASA Modular Combustion Test Article, was also investigated. No change in the transmission characteristics of the windows occurred as the pressure difference across the windows increased from 0 psig up to 150 psig. A calibration was performed on the UV Raman system at Vanderbilt University, which is similar to the one at the NASA-Marshall Test Stand 115. The results of this calibration are described in the form of temperature-dependent functions, f(T)'s, that account for the increase in Raman scattering cross section with an increase in temperature and also account for the reduction in collected Raman signal if wavelength integration does not occur across the entire wavelength range of the Raman signal. These functions generally vary only by approximately 10% across their respective temperature ranges, except for the case Of CO2, where there is a factor of three difference in its f(T) from 300 K to 2500 K. However this trend for CO2 is consistent with the experimental work of others, and is expected based on the low characteristic vibrational temperature Of CO2. A time-averaged temperature measurement technique has been developed, using the same equipment as for the work mentioned above, that is based upon high-spectral resolution UV Raman scattering. This technique can provide temperature measurements for flows where pressure cannot be measured.

Wehrmeyer, Joseph A.↗