Search NASA⌕ Search

SEARCH · Search NASA

Results for “Equivalent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Estimation of Errors Associated With Use of Linear-Quadratic Formalism for Evaluation of Biologic Equivalence Between Single and Hypofractionated Radiation Doses: An In Vitro Study

Purpose: To investigate the reliability of the linear-quadratic (LQ) formalism and the magnitude of errors associated with its use in assessing biologic equivalence between single, high radiation doses and hypofractionated radiation doses. Methods and Materials: V79 and EMT6 single cells received single doses of 2-12 Gy or two or three fractions of 4 or 5 Gy, each at 4-h intervals. Single and fractionated doses to actually reduce the cell survival to the same level were determined by a colony assay. The {alpha}/{beta} ratio was obtained from the cell survival curves. Using the {alpha}/{beta} ratio and the LQ formalism, equivalent single doses for the hypofractionated doses were calculated. They were then compared with the actually determined equivalent single doses for the hypofractionated doses. The V79 spheroids received single doses of 5-26 Gy or two to five fractions of 5-12 Gy at 2 or 4-h interval, and then were assayed for cell survival. Next, equivalent single doses for the hypofractionated doses were determined, as were done for the single cells. Results: The {alpha}/{beta} ratio was 5.1 Gy for the V79 single cells and 0.36 Gy for EMT6. In V79, the equivalent single doses for the hypofractionated doses calculated using the LQ formalism were 12-19% lower than the actually measured biologically equivalent single doses. In the EMT6 cells, this trend was also seen, but the differences were not significant. In the V79 spheroids, the calculated doses were 18-30% lower than the measured doses. Conclusion: Conversion of hypofractionated radiation doses to single doses using the LQ formalism could underestimate the effect of hypofractionated radiation by {<=}30%.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Measured Neutron Spectra and Dose Equivalents From a Mevion Single-Room, Passively Scattered Proton System Used for Craniospinal Irradiation

Purpose: To measure, in the setting of typical passively scattered proton craniospinal irradiation (CSI) treatment, the secondary neutron spectra, and use these spectra to calculate dose equivalents for both internal and external neutrons delivered via a Mevion single-room compact proton system. Methods and Materials: Secondary neutron spectra were measured using extended-range Bonner spheres for whole brain, upper spine, and lower spine proton fields. The detector used can discriminate neutrons over the entire range of the energy spectrum encountered in proton therapy. To separately assess internally and externally generated neutrons, each of the fields was delivered with and without a phantom. Average neutron energy, total neutron fluence, and ambient dose equivalent [H* (10)] were calculated for each spectrum. Neutron dose equivalents as a function of depth were estimated by applying published neutron depth–dose data to in-air H* (10) values. Results: For CSI fields, neutron spectra were similar, with a high-energy direct neutron peak, an evaporation peak, a thermal peak, and an intermediate continuum between the evaporation and thermal peaks. Neutrons in the evaporation peak made the largest contribution to dose equivalent. Internal neutrons had a very low to negligible contribution to dose equivalent compared with external neutrons, largely attributed to the measurement location being far outside the primary proton beam. Average energies ranged from 8.6 to 14.5 MeV, whereas fluences ranged from 6.91 × 10{sup 6} to 1.04 × 10{sup 7} n/cm{sup 2}/Gy, and H* (10) ranged from 2.27 to 3.92 mSv/Gy. Conclusions: For CSI treatments delivered with a Mevion single-gantry proton therapy system, we found measured neutron dose was consistent with dose equivalents reported for CSI with other proton beamlines.

07 ISOTOPE AND RADIATION SOURCES↗

Evaluation of the Simplified Assessment Peak Equivalent Stress Design Limit Probability of Failure

The ASME Boiler and Pressure Vessel Code Section III Division 5 Subsection HH Subpart A (HHA) outlines requirements and qualification methods for graphite core components in high temperature reactor environments. One such structural qualification method is the Simplified Assessment outlined in HHA-3220, which represents a comparison of service level specific equivalent stresses to allowable stress values derived from target probability of failures (POFs). The target POF is based on the structural reliability class (SRC) for the components and service condition of interest, and is used to establish design limits for combined membrane and peak equivalent stresses. Combined membrane stress limits are derived from two parameter Weibull distribution fits of the graphite grade specific tensile strength data and the target POF. The combined membrane stress limits are then scaled based on the ratio of flexural strength to tensile strength (referred hereinafter as Rtf) to establish the corresponding peak equivalent stress limits. It is desired that the target POF is at least maintained for both combined membrane and peak equivalent design limits, especially with the use of Rtf. The assessment presented herein examines tensile and flexural data for medium and fine grade graphites relative to the calculated combined membrane and peak equivalent stress limits per HHA-3220 and illustrates the simplified assessment method results in anticipated, or at least conservative, peak equivalent design stress limits.

36 - MATERIALS SCIENCE↗

Radiographic stool quantification: an equivalence study of 484 symptomatic and asymptomatic subjects

Purpose: To determine if symptomatic patients referred for radiographic stool quantification have equivalent stool burden to asymptomatic patients. Method: This was an IRB-approved HIPAA-compliant retrospective equivalence cohort study. An a priori equivalence power calculation was performed. Consecutive abdominal radiographs performed in adult outpatients with bloating, constipation, diarrhea, or abdominal pain to assess “fecal loading” [n = 242 (fecal cohort)] were compared to those performed in asymptomatic adult outpatients to assess “renal stones” [n = 242 (renal cohort)]. Radiographs were randomized and reviewed by two blinded independent abdominal radiologists. Exclusion criteria, designed to avoid unblinding, included urinary tract calculi ≥ 0.5 cm, multiple urinary tract calculi, and ureteral stent(s). Readers scored all radiographs (n = 484) for stool burden using validated Leech criteria [scale: 0 (none) to 15 (extreme diffuse)]. Mean Leech scores and 95% confidence intervals were calculated. Multivariable generalized linear modeling was performed to adjust for baseline medication use, age, and gender. The adjusted parameter estimate was used to test for equivalence in the mean difference between cohorts using Schuirmann’s method of two one-sided t-tests. Inter-reader agreement was assessed with intraclass correlation coefficients. Results: Overall mean Leech scores for fecal [6.9 (95% CI 6.7, 7.2)] and renal [7.3 (95% CI 7.1, 7.5)] cohorts were equivalent within a margin of 0.75 (adjusted mean difference: − 0.4 [90% CI − 0.7, − 0.04]; p value = 0.02). Inter-reader agreement was good [ICC: 0.62 (95% CI 0.56, 0.68)]. Conclusion: Radiographic stool quantification produces equivalent results in symptomatic and asymptomatic adults and is of uncertain value.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relating flow resistance to equivalent roughness

Describing flow resistance using the physical properties of an underlying surface is a recalcitrant problem in overland flow models. If discharge measurements are available, an equivalent roughness (e.g., Manning’s n) can be calibrated to represent the effects of surface properties within the domain with a single numerical value. Alternatively, the flow resistance can be estimated from discharge and velocity measured at a point, typically a runoff plot outlet. However, such experimental estimates are often inconsistent with the equivalent roughness determined from calibration to discharge, even if both derive from the same dataset. For example, if Manning’s equation is used to parameterize flow resistance, the Manning’s n obtained by calibrating a model to discharge differs from the value of n calculated from measured flow and velocity at the hillslope outlet. Here, this discrepancy is resolved by deriving a correction factor relating experimentally-determined flow resistance to the equivalent roughness. The derived correction factor is tested for four commonly-used resistance formulations using 129 rainfall simulator experiments. The correction factor is necessary to reproduce measured velocities, and yields minor improvements in discharge prediction. Plain Language Summary: Accurate runoff prediction is needed for land and water management in dryland regions, where sporadic and limited rainfall necessitate efficient water use and drought mitigation strategies. The skill of runoff models is known to be hindered by out ability to estimate flow resistance, which is the quantity that describes how energy is lost from flowing water to the underlying surface. Typically, models represent flow resistance with an equivalent roughness, e.g., Manning’s n, that is adjusted until the model can reproduce available discharge observations at watershed scale. However, the flow resistance measured in plot-scale experiments (1–10 m) often exceeds equivalent roughness coefficients by a factor of 10. This means that the direct use of plot-scale experimental data to parameterize runoff models could cause errors in discharge and runoff velocity predictions. Here, we resolve these differences by deriving an analytic correction factor that relates flow resistance to the equivalent roughness required for models to reproduce experimental velocity and discharge data. This correction factor is tested using rainfall simulator data from 129 experiments performed in the US Southwest covering a wide range of precipitation intensities, soil textures and vegetation types. Use of the correction factor substantially improves model prediction of flow velocity, which is needed for reproducing the timing of flood events and the estimation of erosion.

54 ENVIRONMENTAL SCIENCES↗

Effects of equivalence ratio variations on turbulent flame speed in lean methane/air mixtures under lean-burn natural gas engine operating conditions

Direct numerical simulations of turbulent premixed air flames were carried out using an inflow-outflow configuration to study the effects of equivalence ratio on the turbulent flame speed in lean mixtures. The inflow velocity was dynamically adjusted at a run-time to stabilize the flame brush location within the computational domain. Linear forcing was applied to maintain the turbulent intensities at desired levels. Numerous equivalence ratios near the lean limit were selected for the same turbulence properties and the normalized turbulent flame speed was shown to be a function of the equivalence ratio. Simulations were performed for over 80 eddy turnover times with the turbulent flame speed obtained by averaging the inflow velocity. Results revealed that the equivalence ratio does not have an explicit effect on the normalized turbulent flame speed over the lean limit. Analysis of flame surface area showed that the surface wrinkling produced by eddies of varying scales was not influenced by the change in equivalence ratios when the Karlovitz and Damkohler numbers are fixed. Lastly based on the flame surface statistics flame surface normal is preferentially parallel to the most compressive strain rate direction for all equivalence ratios.

03 NATURAL GAS↗

The emergence of valency in colloidal crystals through electron equivalents

Colloidal crystal engineering of complex, low-symmetry architectures is challenging when isotropic building blocks are assembled. In this study we describe an approach to generating such structures based upon programmable atom equivalents (nanoparticles functionalized with many DNA strands) and mobile electron equivalents (small particles functionalized with a low number of DNA strands complementary to the programmable atom equivalents). Under appropriate conditions, the spatial distribution of the electron equivalents breaks the symmetry of isotropic programmable atom equivalents, akin to the anisotropic distribution of valence electrons or coordination sites around a metal atom, leading to a set of well-defined coordination geometries and access to three new low-symmetry crystalline phases. All three phases represent the first examples of colloidal crystals, with two of them having elemental analogues (body-centred tetragonal and high-pressure gallium), while the third (triple double-gyroid structure) has no known natural equivalent. This approach enables the creation of complex, low-symmetry colloidal crystals that might find use in various technologies.

36 MATERIALS SCIENCE↗

H I Lyman-alpha equivalent widths of stellar populations

We have compiled a library of stellar Lyman-alpha (Lyα) equivalent widths in O and B stars using the model atmosphere codes CMFGEN and TLUSTY, respectively. The equivalent widths range from about 0 to 30 Å in absorption for early-O to mid-B stars. The purpose of this library is for the prediction of the underlying stellar Lyα absorption in stellar populations of star-forming galaxies with nebular Lyα emission. We implemented the grid of individual equivalent widths into the Starburst99 population synthesis code to generate synthetic Lyα equivalent widths for representative star formation histories. A starburst observed after 10 Myr will produce a stellar Lyα line with an equivalent width of ∼ – 10 ± 4 Å in absorption for a Salpeter initial mass function. The lower value (deeper absorption) results from an instantaneous burst, and the higher value (shallower line) from continuous star formation. Depending on the escape fraction of nebular Lyα photons, the effect of stellar Lyα on the total profile ranges from negligible to dominant. If the nebular escape fraction is 10%, the stellar absorption and nebular emission equivalent widths become comparable for continuous star formation at ages of 10-20 Myr.

79 ASTRONOMY AND ASTROPHYSICS↗

Lift Equivalence and Cancellation for Airfoil Surge–Pitch–Plunge Oscillations

A NACA 0018 airfoil in freestream velocity is oscillated in longitudinal, transverse, and angle-of-attack directions with respect to the freestream velocity, known as surge, plunge, and pitch. The lift-based equivalence method introduces phase shifts between these three motions to construct in-phase sinusoidal components for maximum lift, waveform construction. Lift cancellation is also determined with the exact negative pitch and plunge motion amplitudes found from the equivalence method to achieve out-of-phase wave destruction. Lift cancellation occurs when a combination of these motions is sought to obtain a constant lift magnitude throughout the oscillation cycle. To achieve both equivalence and cancellation of lift, a prescribed pure pitch amplitude through the Theodorsen theory equates the corresponding equivalent plunge amplitude and pitch–plunge phase shift. These Theodorsen, linear superposition findings of pitch–plunge are leveraged toward the Greenberg theory to determine a closed-form, surge–pitch–plunge solution through the addition of a surge–plunge phase shift and optimal surge amplitude for lift cancellation. The lift cancellation surge–pitch–plunge amplitudes define the equivalence amplitude investigated here and theoretically limit the experiment to combinations of the first lift harmonic of the Greenberg theory. The analytical results are then compared with experimental lift force measurements and dye visualization. Finally, the normalized lift differences due to unsteady wake and boundary-layer behavior are examined to explore the extents of the Greenberg theory for these cases of lift-based equivalence and cancellation.

42 ENGINEERING↗

Emergence of Relations and the Essence of Learning: A Review of Sidman's Equivalence Relations and Behavior: A Research Story

Sidman addresses two very important questions in Equivalence Relations and Behavior: A Research Story: What are the bases of behavioral competence? And how do units of learning become related? The book recounts the story of how an understanding of emergent relations and competencies was achieved through studies in his teaching-research program with mentally retarded subjects. Although children normally accrue vast networks of relations between stimuli and events, those with mental retardation typically do not. Consequently, by learning how to establish those networks, Sidman and his students contribute richly both to the cultivation of competencies by their subjects and, more generally, to an understanding of real-world human behavior. The basic equivalence paradigm affords the subject feedback and reinforcement for very specific choices during training, but the test is not for those choices! Rather, tests for equivalence look for new choices, ones seemingly quite foreign to the training regimen. The tests for equivalence relations entail presentations of stimuli that were the options for conditional choice during reinforced training. In tests of equivalence, correct choices are novel; hence, they have never been reinforced during training. The study of equivalence relations can encourage the emergence of new perspectives that are more symbiotic than competitive. In full acknowledgment of the important role and contributions made by those who identify themselves as experimental analysts of behavior, it is timely that rapprochements be worked toward, as indeed they are, to meld that perspective with others of our time. Both our research methods and our expectations about the nature of the learning process and the abilities of our subjects can delimit what they might learn and what we, in turn, learn about their learning. The text will be of great value for instruction at the upper-division and graduate levels. Its impact will be substantial, for it defines an important advance in our efforts to understand the richness of behavior in both humans and nonhuman animals. Although not presented to that end, the book might also serve to bridge communications with other groups of animal researchers whose interests lie more in a comparative or ethological framework.

Rumbaugh, Duane M.↗

Response of a tissue equivalent proportional counter to neutrons

The absorbed dose as a function of lineal energy was measured at the CERN-EC Reference-field Facility (CERF) using a 512-channel tissue equivalent proportional counter (TEPC), and neutron dose equivalent response evaluated. Although there are some differences, the measured dose equivalent is in agreement with that measured by the 16-channel HANDI tissue equivalent counter. Comparison of TEPC measurements with those made by a silicon solid-state detector for low linear energy transfer particles produced by the same beam, is presented. The measurements show that about 4% of dose equivalent is delivered by particles heavier than protons generated in the conducting tissue equivalent plastic. c2002 Elsevier Science Ltd. All rights reserved.

NASA Center JSC↗

Application of Adjoint Methodology to Supersonic Aircraft Design Using Reversed Equivalent Areas

This paper presents an approach to shape an aircraft to equivalent area based objectives using the discrete adjoint approach. Equivalent areas can be obtained either using reversed augmented Burgers equation or direct conversion of off-body pressures into equivalent area. Formal coupling with CFD allows computation of sensitivities of equivalent area objectives with respect to aircraft shape parameters. The exactness of the adjoint sensitivities is verified against derivatives obtained using the complex step approach. This methodology has the benefit of using designer-friendly equivalent areas in the shape design of low-boom aircraft. Shape optimization results with equivalent area cost functionals are discussed and further refined using ground loudness based objectives.

Rallabhandi, Sriram K.↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Effects of fuel type and equivalence ratios on the flickering of triple flames

An experimental study has been conducted in axisymmetric, co-flowing triple flames with different equivalence ratios of the inner and outer reactant streams (2<{phi}{sub in}<3 and 0{<=}{phi}{sub out}<0.7). Different fuel combinations, like propane/propane, propane/methane or methane/methane in the inner and outer streams respectively, have been used in the experiments. The structures of the triple flames have been compared for the different fuel combinations and equivalence ratios. The conditions under which triple flames exhibit oscillation have been identified. During the oscillation, the non-premixed flame and the outer lean premixed flame flicker strongly, while the inner rich premixed flame remains more or less stable. The flickering frequency has been evaluated through image processing and fast Fourier transform (FFT) of the average pixel intensity of the image frames. It is observed that, for all the fuel combinations, the frequency decreases with the increase in the outer equivalence ratio, while it is relatively invariant with the change in the inner equivalence ratio. However, an increase in the inner equivalence ratio affects the structure of the flame by increasing the heights of the inner premixed flame and non-premixed flame and also enlarges the yellow soot-laden zone at the tip of the inner flame. A scaling analysis of the oscillating flames has been performed based on the measured parameters, which show a variation of Strouhal number (St) with Richardson number (Ri) as St {proportional_to} Ri{sup 0.5}. The fuel type is found to have no influence on this correlation. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Out-of-Field Dose Equivalents Delivered by Passively Scattered Therapeutic Proton Beams for Clinically Relevant Field Configurations

Purpose: Microdosimetric measurements were performed at Massachusetts General Hospital, Boston, MA, to assess the dose equivalent external to passively delivered proton fields for various clinical treatment scenarios. Methods and Materials: Treatment fields evaluated included a prostate cancer field, cranial and spinal medulloblastoma fields, ocular melanoma field, and a field for an intracranial stereotactic treatment. Measurements were completed with patient-specific configurations of clinically relevant treatment settings using a silicon-on-insulator microdosimeter placed on the surface of and at various depths within a homogeneous Lucite phantom. The dose equivalent and average quality factor were assessed as a function of both lateral displacement from the treatment field edge and distance downstream of the beam's distal edge. Results: Dose-equivalent value range was 8.3-0.3 mSv/Gy (2.5-60-cm lateral displacement) for a typical prostate cancer field, 10.8-0.58 mSv/Gy (2.5-40-cm lateral displacement) for the cranial medulloblastoma field, 2.5-0.58 mSv/Gy (5-20-cm lateral displacement) for the spinal medulloblastoma field, and 0.5-0.08 mSv/Gy (2.5-10-cm lateral displacement) for the ocular melanoma field. Measurements of external field dose equivalent for the stereotactic field case showed differences as high as 50% depending on the modality of beam collimation. Average quality factors derived from this work ranged from 2-7, with the value dependent on the position within the phantom in relation to the primary beam. Conclusions: This work provides a valuable and clinically relevant comparison of the external field dose equivalents for various passively scattered proton treatment fields.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the Combined Effect of Radiation Therapy and Hyperthermia in Terms of Equivalent Dose Distributions

Purpose: To develop a method to quantify the therapeutic effect of radiosensitization by hyperthermia; to this end, a numerical method was proposed to convert radiation therapy dose distributions with hyperthermia to equivalent dose distributions without hyperthermia. Methods and Materials: Clinical intensity modulated radiation therapy plans were created for 15 prostate cancer cases. To simulate a clinically relevant heterogeneous temperature distribution, hyperthermia treatment planning was performed for heating with the AMC-8 system. The temperature-dependent parameters α (Gy{sup −1}) and β (Gy{sup −2}) of the linear–quadratic model for prostate cancer were estimated from the literature. No thermal enhancement was assumed for normal tissue. The intensity modulated radiation therapy plans and temperature distributions were exported to our in-house-developed radiation therapy treatment planning system, APlan, and equivalent dose distributions without hyperthermia were calculated voxel by voxel using the linear–quadratic model. Results: The planned average tumor temperatures T90, T50, and T10 in the planning target volume were 40.5°C, 41.6°C, and 42.4°C, respectively. The planned minimum, mean, and maximum radiation therapy doses were 62.9 Gy, 76.0 Gy, and 81.0 Gy, respectively. Adding hyperthermia yielded an equivalent dose distribution with an extended 95% isodose level. The equivalent minimum, mean, and maximum doses reflecting the radiosensitization by hyperthermia were 70.3 Gy, 86.3 Gy, and 93.6 Gy, respectively, for a linear increase of α with temperature. This can be considered similar to a dose escalation with a substantial increase in tumor control probability for high-risk prostate carcinoma. Conclusion: A model to quantify the effect of combined radiation therapy and hyperthermia in terms of equivalent dose distributions was presented. This model is particularly instructive to estimate the potential effects of interaction from different treatment modalities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MEMS 3-DoF gyroscope design, modeling and simulation through equivalent circuit lumped parameter model

Pre-fabrication, behavioural and performance analysis with computer aided design (CAD) tools is a common and fabrication cost effective practice. In light of this we present a simulation methodology for a dual-mass oscillator based 3 Degree of Freedom (3-DoF) MEMS gyroscope. 3-DoF Gyroscope is modeled through lumped parameter models using equivalent circuit elements. These equivalent circuits consist of elementary components which are counterpart of their respective mechanical components, used to design and fabricate 3-DoF MEMS gyroscope. Complete designing of equivalent circuit model, mathematical modeling and simulation are being presented in this paper. Behaviors of the equivalent lumped models derived for the proposed device design are simulated in MEMSPRO T-SPICE software. Simulations are carried out with the design specifications following design rules of the MetalMUMPS fabrication process. Drive mass resonant frequencies simulated by this technique are 1.59 kHz and 2.05 kHz respectively, which are close to the resonant frequencies found by the analytical formulation of the gyroscope. The lumped equivalent circuit modeling technique proved to be a time efficient modeling technique for the analysis of complex MEMS devices like 3-DoF gyroscopes. The technique proves to be an alternative approach to the complex and time consuming couple field analysis Finite Element Analysis (FEA) previously used.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗