At least 91 records · Page 5

Creep in Photovoltaic Modules: Examining the Stability of Polymeric Materials and Components

Interest in renewable energy has motivated the implementation of new polymeric materials in photovoltaic modules. Some of these are non-cross-linked thermoplastics, in which there is a potential for new behaviors to occur, including phase transformation and visco-elastic flow. Differential scanning calorimetry and rheometry data were obtained and then combined with existing site-specifictime-temperature information in a theoretical analysis to estimate the displacement expected to occur during module service life. The analysis identified that, depending on the installation location, module configuration and/or mounting configuration, some of the thermoplastics are expected to undergo unacceptable physical displacement. While the examples here focus on encapsulation materials,the concerns apply equally to the frame, junction-box, and mounting-adhesive technologies.

14 SOLAR ENERGY↗

The {sup 136}Xe + {sup 198}Pt Reaction: a Detailed Re-examination

We extend previous measurements of the transfer product yields in the reaction of E-c.m. = 450 MeV Xe-136 with Pt-198 by measurements of the product yields using Gammasphere. By recording events occurring in beam bursts and in between beam bursts, we are able to extend the number of measured product yields from 78 to 171 nuclides. Our new data span a much wider range of Z and A than observed in previous work and when compared to theoretical predictions, these new measurements provide a more stringent and thorough test of models of multi-nucleon transfer (MNT) reactions.

Desai, V. V.↗

Data for "Examining Organic Acid Production Potential and Growth-Coupled Strategies in Issatchenkia orientalis Using Constraint-Based Modeling"

Growth-coupling product formation can facilitate strain stability by aligning industrial objectives with biological fitness. Organic acids make up many building block chemicals that can be produced from sugars obtainable from renewable biomass. Issatchenkia orientalis is a yeast strain tolerant to acidic conditions and is thus a promising host for industrial production of organic acids. Here, we use constraint-based methods to assess the potential of computationally designing growth-coupled production strains for I. orientalis that produce 22 different organic acids under aerobic or microaerobic conditions. We explore native and engineered pathways using glucose or xylose as the carbon substrates as proxy constituents of hydrolyzed biomass. We identified growth-coupled production strategies for 37 of the substrate-product pairs, with 15 pairs achieving production for any growth rate. We systematically assess the strain design solutions and categorize the underlying principles involved.

Bioproducts↗

Application of an Online-Coupled Regional Climate Model, WRF-CAM5, over East Asia for Examination of Ice Nucleation Schemes: Part I. Comprehensive Model Evaluation and Trend Analysis for 2006 and 2011

Online-coupled climate and chemistry models are necessary to realistically represent the interactions between climate variables and chemical species and accurately simulate aerosol direct and indirect effects on cloud, precipitation, and radiation. In this Part I of a two-part paper, simulations from the Weather Research and Forecasting model coupled with the physics package of Community Atmosphere Model (WRF-CAM5) are conducted with the default heterogeneous ice nucleation parameterization over East Asia for two full years: 2006 and 2011. A comprehensive model evaluation is performed using satellite and surface observations. The model shows an overall acceptable performance for major meteorological variables at the surface and in the boundary layer, as well as column variables (e.g., precipitation, cloud fraction, precipitating water vapor, downward longwave and shortwave radiation). Moderate to large biases exist for cloud condensation nuclei over oceanic areas, cloud variables (e.g., cloud droplet number concentration, cloud liquid and ice water paths, cloud optical depth, longwave and shortwave cloud forcing). These biases indicate a need to improve the model treatments for cloud processes, especially cloud droplets and ice nucleation, as well as to reduce uncertainty in the satellite retrievals. The model simulates well the column abundances of chemical species except for column SO 2 but relatively poor for surface concentrations of several species such as CO, NO 2 , SO 2 , PM2.5, and PM10. Several reasons could contribute to the underestimation of major chemical species in East Asia including underestimations of anthropogenic emissions and natural dust emissions, uncertainties in the spatial and vertical distributions of the anthropogenic emissions, as well as biases in meteorological, radiative, and cloud predictions. Despite moderate to large biases in the chemical predictions, the model performance is generally consistent with or even better than that reported for East Asia with only a few exceptions. The model generally reproduces the observed seasonal variations and the difference between 2006 and 2011 for most variables or chemical species. Overall, these results demonstrate promising skills of WRF-CAM5 for long-term simulations at a regional scale and suggest several areas of potential improvements.

54 ENVIRONMENTAL SCIENCES↗

Physical examination during space flight

OBJECTIVE: To develop techniques for conducting a physical examination in microgravity and to describe and document the physiologic changes noted with use of a modified basic physical examination. DESIGN: On the basis of data gathered from physical examinations on KC-135 flights, three physical variables were assessed serially in astronauts during two shuttle missions (of 8- and 10-day duration, respectively). Preflight, in-flight, and postflight examinations were conducted by trained physician-astronauts or flight surgeons, who used this modified examination. MATERIAL AND METHODS: Five male and two female crewmembers participated in the "hands-on" physical examination of all physiologic systems except the genitourinary system. Level of edema, intensity of bowel sounds, and peripheral reflexes were assessed and graded. RESULTS: This investigation identified unique elements of a physical examination performed during space flight that will assist in the development of standard methods for conducting examinations of astronauts in weightlessness. In addition, demonstrable changes induced by microgravity were noted in most physiologic systems examined. CONCLUSION: The data support the hypothesis that the microgravity examination differs from that conducted on earth or in a 1g environment. In addition, alterations in the physiologic response can be detected with use of hands-on technique. These data are invaluable in the development of optimal medical care for humans in space.

STS Shuttle Project↗

American College of Radiology In-Training Examination for Residents in Radiation Oncology (2004-2007)

Purpose: To review the results of the recent American College of Radiology (ACR) in-training examinations in radiation oncology and to provide information regarding the examination changes in recent years. Methods and Materials: A retrospective review of the 2004 to 2007 ACR in-training examination was undertaken. Results: The number of residents taking the in-training examination increased from 2004 to 2007, compatible with the increase in the number of radiation oncology residents in the United States and Canada. The number of questions decreased from approximately 510 in 2004 and 2005, to 405 in 2006 and 360 in 2007, most of these changes were in the clinical oncology section. Although the in-training examination showed construct validity with resident performance improving with each year of additional clinical oncology training, it did so only until Level 3 for biology and physics. Several changes have been made to the examination process, including allowing residents to keep the examination booklet for self-study, posting of the answer key and rationales to questions on the ACR Website, and providing hard copies to residency training directors. In addition, all questions are now A type or multiple choice questions with one best answer, similar to the American Board of Radiology written examination for radiation oncology. Conclusion: Several efforts by the ACR have been made in recent years to make the examination an educational tool for radiation oncology residents and residency directors.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intracranial CT angiography obtained from a cerebral CT perfusion examination

CT perfusion (CTP) examinations of the brain are performed increasingly for the evaluation of cerebral blood flow in patients with stroke and vasospasm after subarachnoid hemorrhage. Of the same patient often also a CT angiography (CTA) examination is performed. This study investigates the possibility to obtain CTA images from the CTP examination, thereby possibly obviating the CTA examination. This would save the patient exposure to radiation, contrast, and time. Each CTP frame is a CTA image with a varying amount of contrast enhancement and with high noise. To improve the contrast-to-noise ratio (CNR) we combined all 3D images into one 3D image after registration to correct for patient motion between time frames. Image combination consists of weighted averaging in which the weighting factor of each frame is proportional to the arterial contrast. It can be shown that the arterial CNR is maximized in this procedure. An additional advantage of the use of the time series of CTP images is that automatic differentiation between arteries and veins is possible. This feature was used to mask veins in the resulting 3D images to enhance visibility of arteries in maximum intensity projection (MIP) images. With a Philips Brilliance 64 CT scanner (64x0.625 mm) CTP examinations of eight patients were performed on 80 mm of brain using the toggling table technique. The CTP examination consisted of a time series of 15 3D images (2x64x0.625 mm; 80 kV; 150 mAs each) with an interval of 4 s. The authors measured the CNR in images obtained with weighted averaging, images obtained with plain averaging, and images with maximal arterial enhancement. The authors also compared CNR and quality of the images with that of regular CTA examinations and examined the effectiveness of automatic vein masking in MIP images. The CNR of the weighted averaged images is, on the average, 1.73 times the CNR of an image at maximal arterial enhancement in the CTP series, where the use of plain averaging increases the CNR only with a factor of 1.49. The quality of the weighted averaged images approaches that of CTA images, although in the present study the image quality of CTA was not quite reached. The automatic masking of veins is effective and only small remnants of veins were sometimes present in the masked images. Weighted averaging makes it possible to create CTA images from a CTP examination with a CNR considerably higher than that of images with maximal arterial enhancement. The quality of the resulting images approaches that of CTA images and offers the additional advantages to automatically differentiate between arteries and veins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

U.S. Efforts in Support of Examinations at Fukushima Daiichi - November 2022 Meeting Notes and Information Request Status

Information obtained from Fukushima Daiichi Nuclear Power Station (Daiichi) is required to inform future Decontamination and Decommissioning (D&D) activities, improving the ability of the Tokyo Electric Power Company Holdings, Incorporated (TEPCO Holdings) to characterize potential hazards and to ensure the safety of workers involved with cleanup activities. This information also has important implications for the safety and operation of U.S. commercial nuclear power plants. This document summarizes results from the Fiscal Year 2023 (FY2023) U.S. effort to review Daiichi information and extract insights to enhance the safety of existing and future nuclear power plant designs. This U.S. effort, which was initiated in 2014 by the Department of Energy Office of Nuclear Energy, is completed by a group of experts in reactor safety and plant operations that identify examination needs and evaluate recent Daiichi examination data to address these needs. Fukushima-related information and associated discussions during these meetings benefit operating, new, and advanced reactors. Significant safety insights have been and are continuing to be obtained in several areas: system and component performance, radionuclide surveys and sampling, debris end-state location, combustible gas effects, and plant operations and maintenance. In addition to reducing uncertainties related to severe accident modeling progression, these insights have and continue to be used to update guidance for severe accident prevention, mitigation, and emergency planning. Furthermore, Daiichi-related activities, such as code modeling improvements and analysis, testing, and new technology deployment efforts, have the potential to offer additional benefits to the operating fleet and new LWR and non-LWR designs. U.S. evaluations of obtained examination information and input regarding future Daiichi examinations are of interest to several organizations within Japan. Since its inception, the U.S. has provided consensus input for high priority time-sequenced examination tasks and supporting research activities. In their Mid-to-Long-term Examination Plan for 1F investigations, TEPCO included all remaining U.S. consensus information requests and additional information requests they identified. TEPCO periodically provides reports on the status of these requests (reflecting D&D priorities, new insights from investigations, and new technologies that become available). Hence, U.S. experts agreed that it was appropriate for TEPCO to track and prioritize these information requests as D&D progresses. U.S. experts will continue to review and comment on the information obtained from examinations and, as needed, provide additional details and relevant background material to support future examinations. As documented in this report, several other items, such as additional details on information requests pertaining to ex-vessel examinations, relevant references from prior research, additional documents to provide insights regarding recent investigation findings, and reviews of recently released documents, were agreed to during the FY2023 meeting.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Postirradiation Examination of the ATF-1 Experiments - 2018 Status

The Advanced Fuels Campaign in collaboration with industry are working to develop enhanced accident tolerant fuels for light water reactors. The initial irradiations of these concepts were performed in the Idaho National Laboratory Advanced Test Reactor using simple drop-in style irradiations. These irradiations are collectively referred to as ATF 1. The postirradiation examination of ATF 1 has begun and some concepts have now completed initial examination. This report describes the results of examinations on ATF 1 irradiations designed to test the feasibility of enhancing UO 2 thermal conductivity with additives, ATF 1 irradiations of uranium silicide, and the current status of ATF 1 irradiations that are in process at the hot cell. Enhanced thermal conductivity uranium dioxide composites containing silicon carbide (UO 2 SiC) and diamond (UO 2 diamond) have been irradiated to low burnup. The conditions of this irradiation test and subsequent postirradiation examinations are discussed. These irradiations evaluate fuel microstructure and potential fuel cladding interaction under representative light water reactor power conditions. Both non destructive and destructive techniques have been used to evaluate fuel integrity, fission gas release, fission product distribution, burnup, fuel swelling and cladding strain. Examination of the UO 2 SiC pellets revealed enhanced cracking when compared to a UO 2 rodlet also irradiated under similar conditions. Additionally, instability of the SiC whiskers in the uranium dioxide matrix was observed in the pellet central region, where the local temperatures exceeded 1300 °C. The microstructure of the diamond added UO 2 was severely disrupted during irradiation, resulting in local migration of cesium along the fuel stack and increased fission gas release when compared with the expected release from the Vitanza curve at corresponding values of burnup and irradiation temperature. The postirradiation examination results cast doubt on the suitability of these additives to improve UO 2 fuel performance in a way that would lead to enhanced accident tolerance. Additionally, postirradiation examination data of U 3 Si 2 fuels at low burnup (i.e., < 20 GWd/tHM) for application in advanced Light Water Reactor (LWR) is presented. The U 3 Si 2 pellets show limited cracking in comparison to the expected behavior of UO 2 at same power level. In addition, gamma scanning data did not reveal migration of fission products. Minor homogeneous hardening along the pellet radius due to accumulation of fission products and radiation damage was measured by microindentation. The fission gas release and swelling remains very low. Formation of fission gas bubbles resolvable with optical microscopy occurs from the pellets center outward to approximately 60% of the fuel pellet radius. The overall data suggest a good performance of this accident tolerant fuel candidate at low burnup. Finally, the current status of postirradiation examination on other ATF 1 irradiations will be discussed. These irradiations include UO 2 clad in an FeCrAl alloy, an alternative uranium silicide compound U 3 Si 5 also clad in a FeCrAl alloy, and an interaction test between UO 2 and different FeCrAl alloys.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

On the use of Monte Carlo-derived dosimetric data in the estimation of patient dose from CT examinations

The purpose of this work was to investigate the applicability and appropriateness of Monte Carlo-derived normalized data to provide accurate estimations of patient dose from computed tomography (CT) exposures. Monte Carlo methodology and mathematical anthropomorphic phantoms were used to simulate standard patient CT examinations of the head, thorax, abdomen, and trunk performed on a multislice CT scanner. Phantoms were generated to simulate the average adult individual and two individuals with different body sizes. Normalized dose values for all radiosensitive organs and normalized effective dose values were calculated for standard axial and spiral CT examinations. Discrepancies in CT dosimetry using Monte Carlo-derived coefficients originating from the use of: (a) Conversion coefficients derived for axial CT exposures, (b) a mathematical anthropomorphic phantom of standard body size to derive conversion coefficients, and (c) data derived for a specific CT scanner to estimate patient dose from CT examinations performed on a different scanner, were separately evaluated. The percentage differences between the normalized organ dose values derived for contiguous axial scans and the corresponding values derived for spiral scans with pitch=1 and the same total scanning length were up to 10%, while the corresponding percentage differences in normalized effective dose values were less than 0.7% for all standard CT examinations. The normalized organ dose values for standard spiral CT examinations with pitch 0.5-1.5 were found to differ from the corresponding values derived for contiguous axial scans divided by the pitch, by less than 14% while the corresponding percentage differences in normalized effective dose values were less than 1% for all standard CT examinations. Normalized effective dose values for the standard contiguous axial CT examinations derived by Monte Carlo simulation were found to considerably decrease with increasing body size of the mathematical phantom used. When the body-mass index was increased from 23.0 to 32.7 kg/m{sup 2} discrepancies in patient effective dose were up to 34%. The error in estimating effective dose from a CT exposure performed on a specific CT scanner using Monte Carlo data derived for a different CT scanner was estimated to be up to 25%. A simple method was proposed and validated for the determination of scanner-specific normalized dosimetric data from data derived from Monte Carlo simulation of a specific scanner. In conclusion, computed tomography dose index (CTDI) to effective dose conversion coefficients derived by Monte Carlo simulation of axial CT scans may provide a good approximation of corresponding coefficients applicable in helical scans. However, the use of Monte Carlo conversion coefficients for the estimation of patient dose from a CT examination involves a remarkable inaccuracy when the body size of the mathematical anthropomorphic phantom used in Monte Carlo simulation differs from the body of the patient. Therefore, separate sets of Monte Carlo dosimetric CT data shall be generated for different patient body sizes. Besides calculation of different sets of Monte Carlo data for each commercially available scanner is not necessary, since scanner specific data may be derived with acceptable accuracy from the Monte Carlo data calculated for a specific scanner appropriately modified for the different CTDI{sub w}/CTDI{sub air} ratio.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Estimating pediatric entrance skin dose from digital radiography examination using DICOM metadata: A quality assurance tool

Purpose: To develop an automated methodology to estimate patient examination dose in digital radiography (DR) imaging using DICOM metadata as a quality assurance (QA) tool. Methods: Patient examination and demographical information were gathered from metadata analysis of DICOM header data. The x-ray system radiation output (i.e., air KERMA) was characterized for all filter combinations used for patient examinations. Average patient thicknesses were measured for head, chest, abdomen, knees, and hands using volumetric images from CT. Backscatter factors (BSFs) were calculated from examination kVp. Patient entrance skin air KERMA (ESAK) was calculated by (1) looking up examination technique factors taken from DICOM header metadata (i.e., kVp and mA s) to derive an air KERMA (k{sub air}) value based on an x-ray characteristic radiation output curve; (2) scaling k{sub air} with a BSF value; and (3) correcting k{sub air} for patient thickness. Finally, patient entrance skin dose (ESD) was calculated by multiplying a mass–energy attenuation coefficient ratio by ESAK. Patient ESD calculations were computed for common DR examinations at our institution: dual view chest, anteroposterior (AP) abdomen, lateral (LAT) skull, dual view knee, and bone age (left hand only) examinations. Results: ESD was calculated for a total of 3794 patients; mean age was 11 ± 8 yr (range: 2 months to 55 yr). The mean ESD range was 0.19–0.42 mGy for dual view chest, 0.28–1.2 mGy for AP abdomen, 0.18–0.65 mGy for LAT view skull, 0.15–0.63 mGy for dual view knee, and 0.10–0.12 mGy for bone age (left hand) examinations. Conclusions: A methodology combining DICOM header metadata and basic x-ray tube characterization curves was demonstrated. In a regulatory era where patient dose reporting has become increasingly in demand, this methodology will allow a knowledgeable user the means to establish an automatable dose reporting program for DR and perform patient dose related QA testing for digital x-ray imaging.

60 APPLIED LIFE SCIENCES↗

NDE Reliability Issues for the Examination of CASS Components

The relatively low cost and corrosion resistance of cast austenitic stainless steel (CASS) materials resulted in their extensive use for piping systems in nuclear power plants (NPPs). However, CASS component welds are among the most challenging volumetric examinations required to be performed for detection of potential service degradation. Effective and reliable inspection methods for CASS materials are essential to achieving the objectives of defense-in-depth. A complicating issue is the presence of thermal aging embrittlement, a known degradation mechanism that occurs in CASS NPP materials. Further, while not as yet reported in CASS, many unforeseen instances of cracking in safety-related piping system welds have been experienced in other austenitic materials. Currently, a performance-based method to qualify NDE in CASS is not available. Pacific Northwest National Laboratory (PNNL) has performed nondestructive examination (NDE) research under the sponsorship of the U.S. Nuclear Regulatory Commission (NRC) for over four decades. A primary objective of the research has been to assess the effectiveness and reliability of conventional and advanced NDE methods for the inspection of light-water reactor components. One of the tasks being performed within this framework is to evaluate state-of-the-art technical approaches for examining safety-related nuclear reactor components that pose significant challenges to traditional NDE methods. A specific area of research in this regard is the volumetric examination of coarse-grained weldments and base materials. This report summarizes, compiles, and assesses relevant investigations performed by PNNL and other domestic and international organizations for welds adjacent to CASS components to provide a comprehensive evaluation on this subject. The primary objectives of the report are to assess the overall feasibility for advanced NDE methods to reliably and effectively examine field CASS piping components and to determine if techniques similar to those described in existing standards could be applied to develop performance demonstration requirements for CASS piping components. This report discusses improving the reliability of CASS examinations through the use of advanced low-frequency phased-array techniques, coupled with other “best practice” examination parameters, and makes recommendations for consideration by NRC Staff regarding the development of effective performance-based qualifications for CASS weldments. In addition to the PNNL research documented here, over 230 historical and more recent publications have been reviewed in the development of this document. The report is expected to be a useful resource for engineers and scientists involved in NDE of CASS for purposes of inservice inspection on existing plants during current and extended periods of operation. Finally, researchers and NDE practitioners conducting future investigations to advance the state-of-the-art should find the information contained in this report to be beneficial.

36 MATERIALS SCIENCE↗

Hot Cell Examination of Weapons-Grade MOX Fuel

The U.S. Department of Energy has decided to dispose of a portion of the nation s surplus weapons-grade plutonium by reconstituting it into mixed oxide (MOX) fuel and irradiating it in commercial power reactors. Four lead assemblies were manufactured with weapons-grade MOX and irradiated to a maximum fuel rod burnup of 47.3 MWd/kg. As part of the fuel qualification process, five fuel rods with varying burnups and plutonium contents were selected from one of the assemblies and shipped to Oak Ridge National Laboratory for hot cell examination. This is the first hot cell examination of weapons-grade MOX fuel. The rods have been examined nondestructively with the ADEPT apparatus and are currently being destructively examined. Examinations completed to date include length measurements, visual examination, gamma scanning, profilometry, eddy-current testing, gas measurement and analysis, and optical metallography. Representative results of these examinations are reviewed and found to be consistent with predictions and with prior experience with reactor-grade MOX fuel. The results will be used to support licensing of weapons-grade MOX for batch use in commercial power reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Summary of FUTURIX-FTA Non-destructive Examination

A summary of results from the non-destructive examination of the FUTURIX-FTA irradiation are presented. This irradiation was conducted under true fast spectrum conditions in the Phenix reactor. Baseline non-destructive examinations of these tests have been completed at this time. Results from visual examination, neutron radiography, gamma spectrometry, and dimensional inspection have been collected. The data collected from this irradiation will be compared to sister irradiations performed in pseudo-fast spectrum conditions at the INL Advanced Test Reactor helping to confirm fuel performance behavior observed in Advanced Test Reactor irradiations is representative of fast reactor conditions. All indications from the non-destructive examinations performed on the FUTURIX-FTA elements indicate a successful irradiation with fuel performance in line with expectations. The intact state of the nitride fuel is especially notable as these pellets were fragile after fabrication, but they appear to have survived the irradiation and extensive shipping well. These rodlets will undergo further examination to include gamma tomography to investigate the radial fission product distribution, fission gas release analysis, optical metallography, microhardness testing, and chemical burnup analysis. If possible, cross sections from optical metallography may also be examined by more advanced techniques such as scanning electron microscopy and transmission electron microscopy of specific sites through the use of focused ion beam lift outs. The results of all these examinations will be compared with the results from the AFC-1B, AFC-I1D, AFC-IF, AFC-1G, AFC-1H and AFC-LAE irradiations. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Long-Term Study of Radiation Therapy in T1-2 Node-Negative Breast Cancer Patients in Relation to the Number of Axillary Nodes Examined

Purpose: The optimal number of axillary nodes to be resected is controversial. This large series investigated the effect of surgery with or without adjuvant radiotherapy among node-negative breast cancer patients in relation to the number of nodes examined. Methods and Materials: Node-negative patients from the Saskatchewan registry of 1981-1995 were studied. Because nodal status may be more reliable with more number of nodes examined, we analyzed T1-2 age < 90 patients with < 10 nodes examined treated with surgery alone (Group A{sub S}, n = 509) vs. surgery and adjuvant radiotherapy (Group A{sub S}+R, n = 342); and T1-2 age < 90 patients with {>=} 10 nodes examined treated with surgery alone (Group B{sub S}, n = 902) vs. surgery and adjuvant radiotherapy (Group B{sub S}+R, n = 596). Results: For the two radiotherapy groups, patients with < 10 nodes (Group A{sub S}+R) vs. {>=} 10 nodes (Group B{sub S}+R), there was no difference in overall survival (p = 0.14). In the two nonradiotherapy groups (A{sub S} and B{sub S}), there is a statistically significant decrease in overall survival for patients with < 10 nodes removed (p < 0.001, log-rank test). The optimal number of axillary nodes examined could be 8 nodes with adjuvant radiotherapy (p = 0.05, logrank test) and 12 nodes without adjuvant radiotherapy (p = 0.02, log-rank test). Conclusions: The poorer prognosis of a lesser number of nodes resected was overcome partly by the use of radiotherapy, raising the possibility of micrometastases in lymph nodes not removed. The optimal number of axillary nodes examined could be 8 nodes with adjuvant radiotherapy and 12 nodes without adjuvant radiotherapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Strategy to safely enable X-ray computed tomography examination of highly radioactive tristructural isotropic nuclear fuel

Nondestructive post-irradiation examination of nuclear fuels and materials is useful in collecting data to inform commercial licensing of new nuclear concepts. This work details the planning, shielding design, and workflow of an X-ray computed tomography examination of an irradiated AGR-5/6/7 fuel compact with a dose rate of 1318 R/hr on contact from both β and ɤ-ray radiation with 120 R/hr of the dose rate coming exclusively from ɤ-rays. Post-irradiation examination of highly radioactive samples can help reduce the timeframe from conceptualization of novel nuclear concepts to their commercial implementation as not only is less time spent waiting for experiments to decay away to acceptable levels for examinations, but data from these experiments can more quickly inform model efforts and subsequent experiments. While this work represents the hottest radiological sample that has been openly transported and examined at Idaho National Laboratory’s Irradiated Materials Characterization Laboratory to date, it is anticipated that this work and its lessons learned will facilitate future examinations of similar or even more radioactive specimens.

42 - ENGINEERING↗

SU-E-P-57: Radiation Doses Assessment to Paediatric Patients for Some Digital Diagnostic Radiology Examination in Emergency Department in Qatar

Purpose: The aim of this study was to evaluate radiation doses to pediatric patients undergoing standard radiographic examinations using Direct Digital Radiography (DDR) in Paediatric emergency center of Hamad General Hospital (HGH) in state of Qatar and compared with regional and international Dose Reference Levels (DRLs). Methods: Entrance Skin Dose (ESD) was measured for 2739 patients for two common X-ray examinations namely: Chest AP/PA, Abdomen. Exposure factors such as kV, mAs and Focal to Skin Distance (FSD) were recorded for each patient. Tube Output was measured for a range of selected kV values. ESD for each individual patient was calculated using the tube output and the technical exposure factors for each examination. The ESD values were compared with the some international Dose Reference Levels (DRL) for all types of examinations. Results: The most performed procedure during the time of this study was chest PA/PA (85%). The mean ESD values obtained from AP chest, PA chest and AP abdomen ranged 91–120, 80–84 and 209 – 659 µGy per radiograph for different age’s groups respectively. Two protocols have been used for chest AP and PA using different radiological parameters, and the different of ESD values for chest PA and were 41% for 1 years old child, 57% for 5 years old for chest AP. Conclusion: The mean ESD were compared with those found in literature and were found to be comparable. The radiation dose can be reduced more for Chest AP and PA examination by optimization of each investigation and hence more studies are required for this task. The results presented will serve as a baseline data needed for deriving local reference doses for pediatric X-ray examinations in this local department and hence it can be applied in the whole Qatar.

60 APPLIED LIFE SCIENCES↗