Biomedical monitoring during dynamic stress testing. III - Maximum exercise tolerance - Ergometer.
Maximum exercise tolerance in healthy aircrew members limited by cardiac output
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Maximum exercise tolerance in healthy aircrew members limited by cardiac output
Work conducted in FY23 identified that RELAP5-3D was capable of reproducing trends in HTTF data during experiment PG-27 but was incapable of reproducing measured values. The primary cause of this discrepancy between RELAP5-3D results and experimental data was hypothesized to be a distortion in power density that was introduced by the radial nodalization of the model. We further hypothesized that a new model would provide better results when compared to the experiments PG-27 and PG-29. Work this FY developed a new model that is better capable of capturing local heat generation rates and contains a representation of each 1/6 azimuthal sector of the core. We used this model to develop a new set of solutions to Exercises 1 and 2 of Problems 2 and 3 in the benchmark. In this report, we present the first comprehensive comparison of the results between the two models. We see that in Exercise 1A, which is common between problems 2 and 3, the results are similar, though the results from the new model show greater detail than those from the legacy model. In Problem 2 Exercise 1B and Problem 3 Exercise 1B, we see that heat removal is slower in the new model than the legacy model. Problem 3 Exercise 1C shows temperatures that are lower in most places in the new model than the legacy model, but the area with active heat generation has higher block temperatures in the new model than the legacy model. Problem 3 Exercise 1D further shows that long-term heat removal is lower in the new model. Problem 2 Exercise 1C demonstrated that the new model observes higher temperatures in the core regions than the legacy model, justifying the need to preserve the power density in HTTF. The validation of PG-27 and PG-29 also demonstrated the improved temperature agreement in the core regions, particularly with a calibrated model that implements an effective thermal conductivity for the core material. Overall, PG-27 models show reasonable to excellent agreement for steady-state temperatures and minimal to reasonable agreement for transients. PG-29 models showed minimal to insufficient agreement with the data.
The Interim Resistance Exercise Device (iRED), developed for the International Space Station (ISS), was evaluated using human subjects for a Man-In-The-Loop Test (MILT). Thirty-two human subjects exercised using the iRED in a test that was conducted over a 63-working-day period. The subjects performed the same exercises will be used on board ISS, and the iRED operating constraints that are to be used on ISS were followed. In addition, eight of the subjects were astronauts who volunteered to be in the evaluation in order to become familiar with the iRED and provide a critique of the device. The MILT was scheduled to last for 57,000 exercise repetitions on the iRED. This number of repetitions was agreed to as a number typical of that expected during a 3-person, 17-week ISS Increment. One of the canisters of the iRED failed at the 49,683- repetition mark (87.1% of targeted goal). The remaining canister was operated using the plan for operations if one canister fails during flight (contingency operations). This canister remained functional past the 57,000-repetition mark. This report details the results of the iRED MILT, and lists specific recommendations regarding both operation of the iRED and future resistance exercise device development.
To test the hypothesis that drink composition is more important than osmolality (osm) for maintaining and increasing plasma vol. (PV, hypervolemia) at rest and exercise (21.8C Tdb, 50% rh), 6 men (22-39 vr) underwent six treatments while sitting for 90 min (0.39 l/min) followed by 70 min of sitting ergometer exercise (2.08 l/min, 70%vO2 peak). Resting, intermittent drinking (10 ml/kg, 768 ml) beverages were: P1 (20 mEq Na+, 365 mosmol/kg), P2 (40 mEq Na+. 791 mosm), P2G (40 mEq Na+, 80 ml glycerol, 1.392 mosm). AA (157 mEq Na+, 253 mosm), and 01 and 02 (nothing). The exercise drink (10 ml/kg, 768 ml) was P1 for all experiments, except 02 (nothing). Resting % delta PV (Hb-Hct) increased (P<0.05) by 3-6% only with P2 and AA, respectively, Exercise % delta PV was + 1 to + 3% (NS) with AA, -6% to 0% (KS) with P1, P2. P2G, and 01,and 8% to -5% (P<0.05) with 02- Thus, AA with 157 mEq Na+ and the lowest osmolality maintained PV at rest and exercise, while the other beverages with low Na+ and higher osmolality (365 to 1.382 mosm) did not.
To test the hypothesis that drink composition is more important than drink osmolality (Osm) for maintaining and increasing plasma volume (PV) at rest and during exercise, six men (22-39 yr, 76.84 +/- 16.19 kg, 2.99 +/- 0.45 L/min VO2 peak) each underwent six treatments while sitting for 90 min (VO2 = 0.39 L/min) and then performed upright ergometer exercise for 70 min (VO2 = 2.08 +/- 0.33 1/min, 70% +/- 7% VO2 peak). Drink formulations (10 ml/kg body weight, X = 768 ml) for the sitting period were: P1 (55 mEq Na(+), 365 mOsm/kg H2O), P2 (97.1 mEq Na(+), 791 mOsm/kg), P2G (113 mEqNa(+), 80 ml glycerol, 1,382 mOsm/kg, HyperAde (HA) (164 mEq Na(+), 253 mOsm/kg), and 01 and 02 (no drinking). The exercise drink (10 ml/kg, 768 ml) was P1 for all treatments except 02. Plasma volume at rest increased (p less than 0.05) by 4.7% with P1 and by 7.9% with HA. Percent change in PV during exercise was +1% to +3%0(NS) with HA; -6% to 0% (NS) with P1, P2, P2G, and 01; and -8% to -5% (p less than 0.05) with 02. HyperAde, with the lowest osmolality (253 mOsm/kg), maintained PV at rest and during exercise, whereas the other drinks with lower Na(+) and higher osmolality (365 to 1,382 mOsm/kg) did not. But Performance 1 also increased PV at rest. Thus, drink composition may be more important than drink osmolality for increasing plasma volume at rest and for maintaining it during exercise.
To test the influence of physical activity on the diving reflex, 10 normal men held their breath with their faces immersed in 15 C water during rest, bicycle exercise, and sustained isometric handgrip contraction. At all conditions, a slight but statistically significant elevation of blood pressure and a marked decrease in heart rate occurred during each dive. During moderate bicycle exercise heart rate fell more rapidly than at rest and the final level of bradycardia approached that achieved at rest, despite the fact that predive heart rates were much higher during exercise. When diving occurred in combination with isometric exercise, bradycardia was less severe than during resting dives and final heart rates could be represented as the sum of the expected responses to each intervention alone. In all conditions apnea without face immersion caused bradycardia that was less severe than during wet dives.
Preservation of locomotor capacity by earth equivalent, exercise in space is the crucial component of inflight exercise. At this time the treadmill appears to be the only way possible to do this. Work is underway on appropriate hardware but this and a proposed protocol to reduce exercise time must be tested. Such exercise will preserve muscle, bone Ca(++) and cardiovascular-respiratory capacity. In addition, reasonable upper body exercise can be supplied by a new force generator/measurement system-optional exercise might include a rowing machine and bicycle ergometer. A subject centered monitoring-evaluation program will allow real time adjustments as required. Absolute protection for any astronaut will not be possible and those with hypertrophied capacities such as marathoners or weight lifters will suffer significant loss. However, the program described should return the crew to earth with adequate capacity of typical activity on earth including immediate ambulation and minimal recovery time and without permanent change. An understanding of the practical mechanics and biomechanics involved is essential to a solution of the problem.
In black-box testing, the tester creates a set of tests to exercise a system under test without regard to the internal structure of the system. Generally, no objective metric is used to measure the adequacy of black-box tests. In recent work, we have proposed three requirements coverage metrics, allowing testers to objectively measure the adequacy of a black-box test suite with respect to a set of requirements formalized as Linear Temporal Logic (LTL) properties. In this report, we evaluate the effectiveness of these coverage metrics with respect to fault finding. Specifically, we conduct an empirical study to investigate two questions: (1) do test suites satisfying a requirements coverage metric provide better fault finding than randomly generated test suites of approximately the same size?, and (2) do test suites satisfying a more rigorous requirements coverage metric provide better fault finding than test suites satisfying a less rigorous requirements coverage metric? Our results indicate (1) only one coverage metric proposed -- Unique First Cause (UFC) coverage -- is sufficiently rigorous to ensure test suites satisfying the metric outperform randomly generated test suites of similar size and (2) that test suites satisfying more rigorous coverage metrics provide better fault finding than test suites satisfying less rigorous coverage metrics.
Measurement of microvolt-level T wave alternans (TWA) during routine exercise stress testing now is possible as a result of sophisticated noise reduction techniques and analytic methods that have become commercially available. Even though this technology is new, the available data suggest that microvolt TWA is a potent predictor of arrhythmia risk in diverse disease states. As this technology becomes more widely available, physicians will be called upon to interpret microvolt TWA tracings. This review seeks to establish uniform standards for the clinical interpretation of microvolt TWA tracings.
INTRODUCTION: Plasma volume, heart rate (HR) variability, and stimulus-response relationships for baroreflex control of forearm vascular resistance (FVR) and HR were studied in eight healthy men after and without performing a bout of maximal exercise to test the hypotheses that acute expansion of plasma volume is associated with 1) reduction in baroreflex-mediated HR response, and 2) altered operational range for central venous pressure (CVP). METHODS: The relationship between stimulus (DeltaCVP) and vasoconstrictive reflex response (DeltaFVR) during unloading of cardiopulmonary baroreceptors was assessed with lower-body negative pressure (LBNP, 0, -5, -10, -15, -20 mm Hg). The relationship between stimulus (Deltamean arterial pressure (MAP)) and cardiac reflex response (DeltaHR) during loading of arterial baroreceptors was assessed with steady-state infusion of phenylephrine (PE) designed to increase MAP by 15 mm Hg alone and during application of LBNP (PE+LBNP) and neck pressure (PE+LBNP+NP). Measurements of vascular volume and autonomic baroreflex responses were conducted on two different test days, each separated by at least 1 wk. On one day, baroreflex response was tested 24 h after graded cycle exercise to volitional exhaustion. On another day, measurement of baroreflex response was repeated with no exercise (control). The order of exercise and control treatments was counterbalanced. RESULTS: Baseline CVP was elevated (P = 0.04) from a control value of 10.5 +/- 0.4 to 12.3 +/- 0.4 mm Hg 24 h after exercise. Average DeltaFVR/DeltaCVP during LBNP was not different (P = 0.942) between the exercise (-1.35 +/- 0.32 pru x mm Hg-1) and control (-1.32 +/- 0.36 pru x mm Hg-1) conditions. However, maximal exercise caused a shift along the reflex response relationship to a higher CVP and lower FVR. HR baroreflex response (DeltaHR/DeltaMAP) to PE+LBNP+NP was lower (P = 0.015) after maximal exercise (-0.43 +/- 0.15 beats x min-1 x mm Hg-1) compared with the control condition (-0.83 +/- 0.14 beats x min-1 x mm Hg-1). CONCLUSION: Expansion of vascular volume after acute exercise is associated with altered operational range for CVP and reduced HR response to arterial baroreceptor stimulation.
Muscle acidosis has been implicated as a major determinant of reflex sympathetic activation during exercise. To test this hypothesis we studied sympathetic exercise responses in metabolic myopathies in which muscle acidosis is impaired or augmented during exercise. As an index of reflex sympathetic activation to muscle, microneurographic measurements of muscle sympathetic nerve activity (MSNA) were obtained from the peroneal nerve. MSNA was measured during static handgrip exercise at 30% of maximal voluntary contraction force to exhaustion in patients in whom exercise-induced muscle acidosis is absent (seven myophosphorylase deficient patients; MD [McArdle's disease], and one patient with muscle phosphofructokinase deficiency [PFKD]), augmented (one patient with mitochondrial myopathy [MM]), or normal (five healthy controls). Muscle pH was monitored by 31P-magnetic resonance spectroscopy during handgrip exercise in the five control subjects, four MD patients, and the MM and PFKD patients. With handgrip to exhaustion, the increase in MSNA over baseline (bursts per minute [bpm] and total activity [%]) was not impaired in patients with MD (17+/-2 bpm, 124+/-42%) or PFKD (65 bpm, 307%), and was not enhanced in the MM patient (24 bpm, 131%) compared with controls (17+/-4 bpm, 115+/-17%). Post-handgrip ischemia studied in one McArdle patient, caused sustained elevation of MSNA above basal suggesting a chemoreflex activation of MSNA. Handgrip exercise elicited an enhanced drop in muscle pH of 0.51 U in the MM patient compared with the decrease in controls of 0.13+/-0.02 U. In contrast, muscle pH increased with exercise in MD by 0.12+/-0.05 U and in PFKD by 0.01 U. In conclusion, patients with glycogenolytic, glycolytic, and oxidative phosphorylation defects show normal muscle sympathetic nerve responses to static exercise. These findings indicate that muscle acidosis is not a prerequisite for sympathetic activation in exercise.
BACKGROUND: Exercise intolerance in heart failure (HF) may be due to inadequate vasodilation, augmented vasoconstriction, and/or altered muscle metabolic responses that lead to fatigue. METHODS AND RESULTS: Vascular and metabolic responses to rhythmic forearm exercise were tested in 9 HF patients and 9 control subjects (CTL) during 2 protocols designed to examine the effect of HF on the time course of oxygen delivery versus uptake (protocol 1) and on vasoconstriction during exercise with 50 mm Hg pressure about the forearm to evoke a metaboreflex (protocol 2). In protocol 1, venous lactate and H+ were greater at 4 minutes of exercise in HF versus CTL (P<0.05) despite similar blood flow and oxygen uptake responses. In protocol 2, mean arterial pressure increased similarly in each group during ischemic exercise. In CTL, forearm blood flow and vascular conductance were similar at the end of ischemic and ambient exercise. In HF, forearm blood flow and vascular conductance were reduced during ischemic exercise compared with the ambient trial. CONCLUSIONS: Intrinsic differences in skeletal muscle metabolism, not vasodilatory dynamics, must account for the augmented glycolytic metabolic responses to moderate-intensity exercise in class II and III HF. The inability to increase forearm vascular conductance during ischemic handgrip exercise, despite a normal pressor response, suggests that enhanced vasoconstriction of strenuously exercising skeletal muscle contributes to exertional fatigue in HF.
The National Aeronautics and Space Administration supported the development of a new vacuum-desorbed regenerative carbon dioxide and humidity control technology for use in short duration human spacecraft. The technology was baselined for use in the Orion Crew Exploration Vehicle s Environmental Control and Life Support System (ECLSS). Termed the Carbon Dioxide And Moisture Removal Amine Swing-bed (CAMRAS), the unit was developed by Hamilton Sundstrand and has undergone extensive testing at Johnson Space Center. The tests were performed to evaluate performance characteristics under range of operating conditions and human loads expected in future spacecraft applications, as part of maturation to increase its readiness for flight. Early tests, conducted at nominal atmospheric pressure, used human metabolic simulators to generate loads, with later tests making us of human test subjects. During these tests many different test cases were performed, involving from 1 to 6 test subjects, with different activity profiles (sleep, nominal and exercise). These tests were conducted within the airlock portion of a human rated test chamber sized to simulate the Orion cabin free air volume. More recently, a test was completed that integrated the CAMRAS with a simulated suit loop using prototype umbilicals and was conducted at reduced atmospheric pressure and elevated oxygen levels. This paper will describe the facilities and procedures used to conduct these and future tests, and provide a summary of findings.
Due to the loss of gravitational loading, astronauts have a tendency to lose bone mineral density in their lumbar spine and lower extremities on orbit. NASA requires astronauts to perform exercises during space flight to help reduce the amount of demineralization. To test these exercises on earth, 17 week bed rest studies are conducted that consist of specific diet and exercise regimes. Developing a finite element model of these exercises will help to quantify the stress distribution imposed by of each of these exercises. To help develop this model, MRI images are acquired from individuals participating in the bed rest studies. The MRIs can be used to create a subject specific model of each individual for testing. The MRIs are processed in the Magnetic Resonance Imaging Data Transfer System program to develop a three-dimensional finite element model of the femur for evaluation. Modifications were made to the MRIDTS that simplified the model creation process. These modifications made it possible to construct two separate models of different portions of a bone simultaneously and then later connect them manually. This helped alleviate the warping problem associated with the drastic changes in geometry found in some body parts, such as the joints. The code was also modified to incorporate material properties of various bone components into the model. Interior meshing was also incorporated into the program to allow for both the cortical shell and the entire bone to be modeled. A prototype model of the right femur of an adult female is being constructed and tested to determine the feasibility of finite element analysis as a tool for evaluating exercise effectiveness. The model is being run through the ANSYS finite element program on the Alabama Super Computer Network. After the model is validated, models of bedrest subjects can be generated to investigate exercise countermeasures.
Exercise response tests were conducted preflight and postflight on Apollo missions 7 to 11. The primary objective of these tests was to detect any changes in the cardiopulmonary response to exercise that were associated with the space flight environment and that could have limited lunar surface activities. A heart-rate-controlled bicycle ergometer was used to produce three heart rate stress levels: 120 beats per minute for 6 minutes; 140 beats per minute for 3 minutes and 160 beats per minute per 3 minutes. Work load, blood pressure and respiratory gas exchange were measured during each stress level. Significant decreases were observed immediately postflight in the following dependent variables at a heart rate of 160 beats per minute: work load, oxygen consumption, systolic blood pressure, and diastolic blood pressure. No changes occurred in work efficiency at 100 watts or the ventilatory equivalent for oxygen at 2.0 liters per minute.
The Advanced Resistive Exercise Device (ARED) was developed for use on the International Space Station as a countermeasure against muscle atrophy and decreased strength. This investigation examined the reliability of one-repetition maximum (1RM) strength testing using ARED and traditional free weight (FW) exercise. Methods: Six males (180.8 +/- 4.3 cm, 83.6 +/- 6.4 kg, 36 +/- 8 y, mean +/- SD) who had not engaged in resistive exercise for at least six months volunteered to participate in this project. Subjects completed four 1RM testing sessions each for FW and ARED (eight total sessions) using a balanced, randomized, crossover design. All testing using one device was completed before progressing to the other. During each session, 1RM was measured for the squat, heel raise, and deadlift exercises. Generalizability (G) and intraclass correlation coefficients (ICC) were calculated for each exercise on each device and were used to predict the number of sessions needed to obtain a reliable 1RM measurement (G . 0.90). Interclass reliability coefficients and Pearson's correlation coefficients (R) also were calculated for the highest 1RM value (1RM9sub peak)) obtained for each exercise on each device to quantify 1RM relationships between devices.
These results clearly demonstrate that dynamic leg exercise against the footward force produced by LBNP substantially improves tolerance to LBNP, and that even cyclic ankle flexion without load bearing also increases tolerance. This exercise-induced increase of tolerance was actually an underestimate, because subjects who completed the tolerance test while exercising could have continued for longer periods. Exercise probably increases LBNP tolerance by multiple mechanisms. Tolerance was increased in part by skeletal muscle pumping venous blood from the legs. Rosenhamer and Linnarsson and Rosenhamer also deduced this for subjects cycling during centrifugation, although no measurements of leg volume were made in those studies: they found that male subjects cycling at 98 W could endure 3 Gz centrifugation longer than when they remained relaxed during centrifugation. Skeletal muscle pumping helps maintain cardiac filling pressure by opposing gravity-, centrifugation-, or LBNP-induced accumulation of blood and extravascular fluid in the legs.
Preflight, inflight, and postflight exercise response tests were conducted on the astronauts of the second Skylab mission as part of an evaluation of physiological adaptation to long-term weightlessness. The flight phase of this mission was 59 days in duration. An exercise protocol was designed around a bicycle ergometer which was used to apply work loads approximating 25, 50, and 75% of each crewman's measured maximum aerobic capacity. Respiratory gas exchange, heart rate, and blood pressure were measured during all tests; cardiac output was measured at selected times during preflight and postflight tests. Data obtained both at rest and during exercise in flight showed no consistent changes which would indicate a degraded physical work capacity. In fact, heart rate during exercise actually decreased for all crewmen in flight. This response indicated improved physical fitness in flight relative to preflight. The postflight period of readaptation to 1 G was characterized by a marked tachycardia, during which time stroke volume was decreased. This response returned to normal within 5-day postflight.