Search NASA⌕ Search

SEARCH · Search NASA

Results for “Extraction chromatography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Developing a Recovery Column for Mo-99 from Highly Concentrated Uranyl Nitrate Solutions

The feasibility of a highly concentrated uranyl nitrate target for 99 Mo production and recovery was investigated with respect to three separate resins. Two resins were inorganic-based – titania and zirconia – and the other was organic-based utilizing Aliquot® 336 extraction chromatography. Results show that pH has a significant effect on select fission products such as Zr whereas Mo is reasonably well retained between pH 0 and 2. Temperature also appreciably affected the retention of Mo. Using a normal-phase titania resin (Sachtapore®), the sorption of Mo was investigated by varying acid and uranium concentrations. The stability of the resin was also studied as a function of acid concentration. Results from the batch studies were then input into the in-house Versatile Reaction Separation (VERSE) code in order to design and optimize a recovery column for 99 Mo. The experimental and model results show that >99.9% of the 99 Mo can be recovered in the presence of saturated uranyl nitrate solutions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Recycling Isotopically Enriched Mo from the RadioGenix Waste Stream

NorthStar’s RadioGenix generator utilizes an aqueous biphasic extraction chromatography column to separate Tc from low-specific-activity 99 Mo. During this separation process, a fraction of the source Mo material can be found in the waste. This is not of concern when natural Mo targets are used. However, the introduction of isotopically enriched 98 Mo for neutron capture or 100 Mo for accelerator-based production requires recovery of this valuable enriched Mo material. The generator waste is absorbed and solidified in a superabsorbent hydrogel polymer. In this contribution, we report results from our small-scale experimental study on development of a separation process for recovery of molybdenum from the polymeric gel waste using common chemicals and simple chemical techniques. Our investigation confirms that the acidic deswelling of the alkaline hydrogel with concentrated hydrochloric acid converts the occluded molybdate to a neutral molybdenyl dichloride species that is freely released from the gel. Mo can then be concentrated on a commercial tri-n-butyl phosphate resin, eluted with ammonium hydroxide, and crystallized as ammonium heptamolybdate for conversion back to Mo metal. Typical Mo recoveries are 90-95%.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cyclotron production of 43Sc and 44gSc from enriched 42CaO, 43CaO, and 44CaO targets

Introduction: 43 Sc and 44g Sc are both positron-emitting radioisotopes of scandium with suitable half-lives and favorable positron energies for clinical positron emission tomography (PET) imaging. Irradiation of isotopically enriched calcium targets has higher cross sections compared to titanium targets and higher radionuclidic purity and cross sections than natural calcium targets for reaction routes possible on small cyclotrons capable of accelerating protons and deuterons. Methods: In this work, we investigate the following production routes via proton and deuteron bombardment on CaCO 3 and CaO target materials: 42 Ca(d,n) 43 Sc, 43 Ca(p,n) 43 Sc, 43 Ca(d,n) 44g Sc, 44 Ca(p,n) 44g Sc, and 44 Ca(p,2n) 43 Sc. Radiochemical isolation of the produced radioscandium was performed with extraction chromatography using branched DGA resin and apparent molar activity was measured with the chelator DOTA. The imaging performance of 43 Sc and 44g Sc was compared with 18 F, 68 Ga, and 64 Cu on two clinical PET/CT scanners. Discussion: The results of this work demonstrate that proton and deuteron bombardment of isotopically enriched CaO targets produce high yield and high radionuclidic purity 43 Sc and 44g Sc. Laboratory capabilities, circumstances, and budgets are likely to dictate which reaction route and radioisotope of scandium is chosen.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of protactinum, actinium, and other radionuclides from proton irradiated thorium target

Protactinium, actinium, radium, radiolanthanides and other radionuclide fission products were separated and recovered from a proton-irradiated thorium target. The target was dissolved in concentrated HCl, which formed anionic complexes of protactinium but not with thorium, actinium, radium, or radiolanthanides. Protactinium was separated from soluble thorium by loading a concentrated HCl solution of the target onto a column of strongly basic anion exchanger resin and eluting with concentrated HCl. Actinium, radium and radiolanthanides elute with thorium. The protactinium that is retained on the column, along with other radionuclides, is eluted may subsequently treated to remove radionuclide impurities to afford a fraction of substantially pure protactinium. The eluate with the soluble thorium, actinium, radium and radiolanthanides may be subjected to treatment with citric acid to form anionic thorium, loaded onto a cationic exchanger resin, and eluted. Actinium, radium and radiolanthanides that are retained can be subjected to extraction chromatography to separate the actinium from the radium and from the radio lanthanides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Automated thermal extraction-desorption gas chromatography mass spectrometry: A multifunctional tool for comprehensive characterization of polymers and their degradation products

The TED-GC–MS analysis is a two-step method. A sample is first decomposed in a thermogravimetric analyzer (TGA) and the gaseous decomposition products are then trapped on a solid-phase adsorber. Subsequently, the solid-phase adsorber is analyzed with thermal desorption gas chromatography mass spectrometry (TDU-GC–MS). This method is ideally suited for the analysis of polymers and their degradation processes. A new entirely automated system is introduced which enables high sample throughput and reproducible automated fractioned collection of decomposition products. The fractionated collection together with low temperatures reduces the risk of contamination, improves instrumental stability and minimizes maintenance efforts. Through variation of the two main parameters (purge gas flow and heating rate) it is shown how the extraction process can be optimized. By measuring the decomposition products of polyethylene it is demonstrated that compounds with masses of up to 434 Da can be detected. This is achieved despite the low temperature (˜40 °C) of the solid-phase adsorber and the low thermal desorption temperature of 200 °C in the TDU unit. It is now shown that automated TED-GC–MS represents a new flexible multi-functional method for comprehensive polymer analyses. Comparable polymer characterization was previously only achievable through a combination of multiple independent analytical methods. This is demonstrated by three examples focused on practical challenges in materials analysis and identification: The first one is the analysis of wood plastic composites for which the decomposition processes of the polymer and the bio polymer (wood) could be clearly distinguished by fractionated collection using sequential adsorbers. Secondly, a fast quantitative application is shown by determining the weight concentrations of an unknown polyolefin blend through comparison with a reference material. Additionally, the determination of microplastic concentrations in environmental samples is becoming an increasingly important analytical necessity. It is demonstrated that with TED-GC–MS calibration curves showing good linearity for the most important precursors for microplastic, even complex matrix materials (suspended particulate matter) can be successfully analyzed.

36 MATERIALS SCIENCE↗

Regenerated silica gel as stationary phase on vacuum column chromatography to purify temulawak’s extracts

Commercial silica gel only used once by many researchers and affected high cost for purification process, also less support the green chemistry program. This research focused in regeneration silica gel that used purification of temulawak’s extracts (Curcuma xanthorrhiza Roxb) by vacuum column chromatography. Sample extracts (contains 10.1195±0.5971% of curcuminoids) was purified by vacuum column chromatography (pressure: 45 kPa, column: 100mm on length and 16mm on diameter). Ethanol 96% and acetone were compared as eluent. The amount of solvent and yield of curcuminoids used as indicator purification. The silica gel was regenerated with heating in 600°C for 8 hours The silica gels were analyzed by IR spectroscopy and X-ray diffraction. Furthermore, regenerated silica gel was used as the stationary phase in vacuum column chromatography under the same conditions with the previous purification. All the purification experiments were performed in three repetitions. Based on regression equation, y=0.132x+0.0011 (r{sup 2}=0.9997) the yield of curcuminoids on purified products using ethanol as the eluent was improved 4.26% (to 14.3724±0.5749%) and by acetone was improved 3,03% (to 13.1450 ±0.6318%). The IR spectrum of both silica gel showed the same vibration profile and also there were three crystallinity peaks missing on its X-ray diffraction. Regenerated silica gel has the same performance with new silica gel in purification of temulawak’s extract: by ethanol has increased 4.08% (14.1947±0.7415%) and 2.93% (13.0447±0.4822) by acetone. In addition, all purification products showed similar TLC profiles. Purification using regenerated silica gel as the adsorbent on vacuum column chromatography has exactly same potential with the new silica gel.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Process for radioisotope recovery and system for implementing same

A method of recovering daughter isotopes from a radioisotope mixture. The method comprises providing a radioisotope mixture solution comprising at least one parent isotope. The at least one parent isotope is extracted into an organic phase, which comprises an extractant and a solvent. The organic phase is substantially continuously contacted with an aqueous phase to extract at least one daughter isotope into the aqueous phase. The aqueous phase is separated from the organic phase, such as by using an annular centrifugal contactor. The at least one daughter isotope is purified from the aqueous phase, such as by ion exchange chromatography or extraction chromatography. The at least one daughter isotope may include actinium-225, radium-225, bismuth-213, or mixtures thereof. A liquid-liquid extraction system for recovering at least one daughter isotope from a source material is also disclosed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Development of a standardized sequential extraction protocol for simultaneous extraction of multiple actinide elements

Sequential extraction is a useful technique for assessing the potential to leach actinides from soils; however, current literature lacks uniformity in experimental details, making direct comparison of results impossible. This work continued development toward a standardized five-step sequential extraction protocol by analyzing extraction behaviors of 232 Th, 238 U, 239,240 Pu and 241 Am from lake and ocean sediment reference materials. Results produced a standardized procedure after creating more defined reaction conditions to improve method repeatability. A NaOH fusion procedure is recommended following sequential leaching for the complete dissolution of insoluble species.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Aqueous Chloride Operations Overview: Plutonium and Americium Purification/Recovery

Acqueous Chloride mission is to recover plutonium and americium from pyrochemical residues (undesirable form for utilization and storage) and generate plutonium oxide and americium oxide. Plutonium oxide is recycled into Pu metal production flowsheet. It is suitable for storage. Americium oxide is a valuable product, sold through the DOE-OS isotope sales program.

61 RADIATION PROTECTION AND DOSIMETRY↗

Core-Shell Diamond as a Support for Solid-Phase Extraction and High-Performance Liquid Chromatography

We report the formation of core-shell diamond particles for solid phase extraction (SPE) and high performance liquid chromatography (HPLC) made by layer-by-layer (LbL) deposition. Their synthesis begins with the amine functionalization of microdiamond by its immersion in an aqueous solution of a primary amine-containing polymer (polyallylamine (PAAm)). The amine-terminated microdiamond is then immersed in an aqueous suspension of nanodiamond, which leads to adsorption of the nanodiamond. Alternating (self-limiting) immersions in the solutions of the amine-containing polymer and the suspension of nanodiamond are continued until the desired number of nanodiamond layers is formed around the microdiamond. Finally, the core-shell particles are cross-linked with 1,2,5,6-diepoxycyclooctane or reacted with 1,2-epoxyoctadecane. Layer-by-layer deposition of PAAm and nanodiamond is also studied on planar Si/SiO2 surfaces, which were characterized by SEM, Rutherford backscattering spectrometry (RBS) and nuclear reaction analysis (NRA). Core-shell particles are characterized by diffuse reflectance infrared Fourier transform spectroscopy (DRIFT), environmental scanning electron microscopy (ESEM), and Brunauer Emmett Teller (BET) surface area and pore size measurements. Larger (ca. 50 μm) core-shell diamond particles have much higher surface areas, and analyte loading capacities in SPE than nonporous solid diamond particles. Smaller (ca. 3 μm), normal and reversed phase, core-shell diamond particles have been used for HPLC, with 36,300 plates per meter for mesitylene in a separation of benzene and alkyl benzenes on a C18 adsorbent, and 54,800 plates per meter for diazinon in a similar separation of two pesticides.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Expanding Coverage of the Metabolome for Global Metabolite Profiling

Mass spectrometry-based metabolomics is the comprehensive study of naturally occurring small molecules collectively known as the metabolome. Given the vast structural diversity and chemical properties of endogenous metabolites, biological extraction and chromatography methods bias the number, property, and concentration of metabolites detected by mass spectrometry and creates a challenge for global untargeted studies. In this work, we used Escherichia coli bacterial cells to explore the influence of solvent polarity, temperature, and pH in extracting polar and nonpolar metabolites simultaneously. In addition, we explored chromatographic conditions involving different stationary and mobile phases that optimize the separation and ionization of endogenous metabolite extracts as well as a mixture of synthetic standards. Our results reveal that hot polar solvents are the most efficient in extracting both hydrophilic and hydrophobic metabolites simultaneously. In addition, ammonium fluoride in the mobile phase substantially improved ionization efficiency in negative electrospray ionization mode by an average increase in signal intensity of 5.7 and over a 2-fold increase in the total number of features detected. The improvement in sensitivity with ammonium fluoride resulted in 3.5 times as many metabolite hits in databases compared to ammonium acetate or formic acid enriched mobile phases and allowed for the identification of unique metabolites involved in fundamental cellular pathways.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chemical-Free Lithium Separation from High-Salinity Brines Using Model-Informed and Machine Learning-Optimized Multi-Column Zwitterionic Chromatography

Direct Lithium Extraction (DLE) technologies often struggle to produce high-purity lithium salts from high-salinity brines, as current approaches require chemical-based elution, regeneration, and precipitation steps, resulting in significant environmental footprints. A novel salt fractionation approach using carboxybetaine resin, known as zwitterionic chromatography (ZIC), has demonstrated that lithium ions can be separated from divalent cations under high-salinity conditions using only water as eluent, with no regeneration required. To enable continuous and scalable deployment of this approach, we developed a chemical-free Multi-column Zwitterionic Chromatography (MZC) process and its theoretical and process models. To predict and optimize this nontraditional separation system, we introduced a novel anti-Langmuir isotherm, and the isotherm parameters were estimated through a machine learning-driven optimization based on artificial neural network ensembles with numerical feasibility assessment. Using machine learning-driven optimization, the MZC process achieved 98.0% lithium recovery, 99.5 % Li/(Li + Mg + Ca) purity, a 31.3% productivity increase, and a 33% reduction in water use compared to batch operation. The proposed MZC process enables lithium separation at $0.6-1.2 kg-1 Li, with costs dominated by resin manufacturing, while offering lower separation costs and carbon footprint compared with conventional carbonation. Overall, these findings position the MZC process as an effective polishing step within scalable and sustainable lithium production pipelines.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of Protactinium Employing Sulfur-Based Extraction Chromatographic Resins

Protactinium-230 (t 1/2 = 17.4 d) is the parent isotope of 230 U (t 1/2 = 20.8 d), a radionuclide of interest for targeted alpha therapy (TAT). Column chromatographic methods have been developed to separate no-carrier-added 230 Pa from proton irradiated thorium targets and accompanying fission products. Results reported within this paper demonstrate the use of novel sulfur bearing chromatographic extraction resins for the selective separation of protactinium. The recovery yield of 230 Pa was 93 ± 4% employing a R 3 P=S type commercially available resin and 88 ± 4% employing a DGTA (diglycothioamide) containing custom synthesized extraction chromatographic resin. The radiochemical purity of the recovered 230 Pa was measured via high purity germanium γ-ray spectroscopy to be >99.5% with the remaining radioactive contaminant being 95 Nb due to its similar chemistry to protactinium. Finally, measured equilibrium distribution coefficients for protactinium, thorium, uranium, niobium, radium, and actinium on both the R 3 P=S type and the DGTA resin in hydrochloric acid media are reported, to the best of our knowledge, for the first time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗