Search NASA⌕ Search

SEARCH · Search NASA

Results for “FINANCIAL MODEL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

North Dakota Refining Capacity Study

According to a 2008 report issued by the United States Geological Survey, North Dakota and Montana have an estimated 3.0 to 4.3 billion barrels of undiscovered, technically recoverable oil in an area known as the Bakken Formation. With the size and remoteness of the discovery, the question became 'can a business case be made for increasing refining capacity in North Dakota?' And, if so what is the impact to existing players in the region. To answer the question, a study committee comprised of leaders in the region's petroleum industry were brought together to define the scope of the study, hire a consulting firm and oversee the study. The study committee met frequently to provide input on the findings and modify the course of the study, as needed. The study concluded that the Petroleum Area Defense District II (PADD II) has an oversupply of gasoline. With that in mind, a niche market, naphtha, was identified. Naphtha is used as a diluent used for pipelining the bitumen (heavy crude) from Canada to crude markets. The study predicted there will continue to be an increase in the demand for naphtha through 2030. The study estimated the optimal configuration for the refinery at 34,000 barrels per day (BPD) producing 15,000 BPD of naphtha and a 52 percent refinery charge for jet and diesel yield. The financial modeling assumed the sponsor of a refinery would invest its own capital to pay for construction costs. With this assumption, the internal rate of return is 9.2 percent which is not sufficient to attract traditional investment given the risk factor of the project. With that in mind, those interested in pursuing this niche market will need to identify incentives to improve the rate of return.

02 PETROLEUM↗

Community Crowd-Funded Solar Finance

The award supported the demonstration and development of the Village Power Platform, which enables community organizations to more readily develop, finance and operate solar installations on local community organizations. The platform enables partial or complete local ownership of the solar installation. The award specifically supported key features including financial modeling tools, community communications tools, crowdfunding mechanisms, a mobile app, and other critical features.

14 SOLAR ENERGY↗

Facilitating Deployment of Community Solar PV systems on Rooftops and Vacant Land in Northeast IL - Final Report

The Cook County Community Solar project set out to unlock the potential of community solar in the Chicago region with lessons that could be applied nationally. One of the first steps was to prove out the potential market. This was done through an opportunity assessment which showed there is over 9,000 megawatts worth of site capacity available for community solar projects in Cook County – nearly enough to offset all of Cook County’s residential electricity use. The assessment also showed that almost 75% of Cook County households are not able to invest directly in solar photovoltaic systems due to a variety of issues from physical barriers such as shading, or condition of the roof, to financial barriers such as lack of roof ownership, or the up-front costs of installation. Because of these barriers, community solar is an essential part of making the benefits of renewable energy available to all of the residents of Cook County. In addition to the opportunity assessment the project team also worked with the over 200 individuals who participated in the stakeholder advisory group to develop a number of other products including: 1) an Economic & Policy Barriers Resolutions and Work Plan document which laid out best practices to address the policy barriers that existed at the time (May of 2016) 2) Value Proposition Report I and Report II which summarize the value of community solar to potential developers and subscribers, 3) The Community Solar Business Case Tool, which provides a flexible financial model that projects the costs and befits to the system developer and subscriber for a project, 4) Bill Crediting Analysis and the 5) Final Report. The Final Report contains 15 case studies which prove that community solar projects are economically feasible in Cook County with a variety of sites, solar designs, ownership and subscriber models.

14 SOLAR ENERGY↗

Commercial Property Assessed Clean Energy (CPACE) for Tax-Exempt and Public Entities (“CivicPACE”)

This report summarizes the work of the CivicPACE team to open the market for property assessed clean energy financing for the nonprofit, tax exempt sector. Property Assessed Clean Energy (PACE) finances property improvements that are paid back through a line item on the property owner’s tax bill. Most states restrict such improvements to renewable energy and energy efficiency, although they may include water conservation and disaster related improvements such as hurricane or earthquake preparedness. When such projects are developed for commercial properties, it is referred to as commercial PACE or CPACE. When CPACE applies to tax exempt or nonprofit organizations, we refer to it as CivicPACE. CivicPACE also represents the name of this program. The purpose of the CivicPACE project was to help nonprofit tax-exempt organizations such as affordable housing, faith-based institutions, and schools gain greater access to financing for solar energy deployment through PACE. As such, the lessons learned and best practices from the CivicPACE team work is intended for state and municipal program designers, PACE administrators, solar installers, and nonprofit organizations. CPACE is experiencing rapid growth. Cumulative CPACE financing grew from 8.2 million in 2010 to 111 million in 2014 to 588 million in 2017. Renewable energy, mostly solar, represents about a quarter of the financing; the nonprofit sector represents about 10% of total financing. The Project Team was formed in early 2015 when solar financing options were limited for nonprofits (NPOs). Traditional bank financing was difficult for nonprofit organizations to secure since they are often viewed as a credit risk. Despite the growth of CPACE, few tax-exempt organizations were using the financing mechanism at the start of 2015. Nonetheless, CPACE financing appeared to have tremendous potential for solar development for tax-exempt organizations such as schools, churches, and multifamily affordable housing, because it addresses many of the traditional nonprofit financing roadblocks, such as credit risk. Given the benefits and the rapid growth of CPACE, the opportunity to expand CPACE financing for solar development on tax-exempt buildings was timely. The Project team was comprised of The Solar Foundation (TSF), Urban Ingenuity (UI), and Clean Energy Solutions, Inc. (CESI). The Solar Foundation was the Principal Investigator and overall team lead. The Solar Foundation is an independent 501(c)(3) nonprofit organization whose mission is to accelerate adoption of the world’s most abundant energy source. PACE financing specialist Urban Ingenuity was the lead for the team for the pilot projects. Clean Energy Solutions (CESI) was the lead on the market analysis, financial modeling, and HUD regulatory issues for PACE financed solar development on affordable housing. The CivicPACE team focused on four key activities to help open the market for CPACE financing of solar development for nonprofit entities: research, pilot projects, technical assistance, and information dissemination.

14 SOLAR ENERGY↗

Innovative Gasification to Produce Fischer-Tropsch Jet and Diesel Fuel

The primary objective of this project and the U.S. DOE’s integrated biorefinery (“IBR”) program was to demonstrate conversion of biomass and waste-derived feedstocks into military spec liquid fuels. Frontline’s proposed integrated process was to incorporate several novel technologies and innovative applications of existing technologies that would serve both to increase plant efficiency and also to lower the cost of the produced biofuels. The project was intended to demonstrate Frontline Bioenergy’s technologies for gasification and synthesis gas clean-up configuration to produce a syngas stream suitable for a proven Fischer-Tropsch (“F-T”) unit that would produce F-T intermediate products. These F-T intermediate products were to be upgraded to military spec diesel and jet fuel, including F76, JP5, and JP8. Specifically, these technologies consisted of: 1. Frontline’s PMFreeGas® ultra low particulate matter (PM) hot gas filtration technology 2. Application of Frontline’s TarFreeGas® ultra low-tar gasification technology 3. Frontline’s novel approach to syngas conditioning The proposed gasifier system was to operate at 10 tpd capacity while the F-T plant was capable of approximately one barrel per day. Although the gasifier output would have been roughly ten times the F-T plant’s required input, the 10 tpd capacity was chosen to enable scaling to commercial capacity. Project partners included i) SGC Energia, owner of the F-T technology and owner of the proposed demonstration site in Pasadena, Texas; ii) Stanley Consultants, a reputable engineering company that provided detailed electrical engineering services; and iii) Delphi Engineering & Construction LLC, a consulting company that provided project management advisory services. The integrated plant was never constructed due to lack of cost share funds. However, the commercialization plan and associated financial model suggested such a plant could be economically viable when the price of oil exceeds $70 per barrel. The price of feedstock plays a significant role in the profitability of the plant for a given value of oil. An integrated biorefinery capable of producing liquid transportation fuels and other chemical feedstocks would benefit the public by providing a sustainable pathway to convert domestically available feedstocks into fuels that might otherwise be imported from countries or regions of the world that are typically hostile to the United States.

09 BIOMASS FUELS↗

Disaggregating Future Retail Electricity Rate Growth [Slides]

Recent Berkeley Lab research found that modest retail rate increases over the past 10 years were mostly driven by large increases in capital expenditures (CapEx) that were offset in part by substantial wholesale price reductions. Decision-makers are increasingly concerned about the potential future rate impacts of a number of policies and industry trends that support rapid decarbonization, electrification, and grid modernization. Using historical FERC Form 1 data and the existing literature on policies and industry trends that are likely to affect utility-incurred costs and retail sales, Berkeley Lab researchers developed ranges of forecasted growth rates for cost-related rate drivers (i.e., fuel and purchased power; transmission, distribution, generation, and other categories of both non-fuel operations & maintenance and CapEx) and non-cost related rate drivers (i.e., retail sales, peak demand, and customers). These were then used as inputs to a pro-forma utility financial model (FINDER) that estimated the growth in retail electric rates between 2020 and 2030 for a prototypical vertically-integrated investor-owned utility in the United States. The analysis produced the following results: 1. Assuming average growth rates in all rate drivers, future retail rate growth is driven by sizable increases in all CapEx costs, where fuel and purchased power costs are replaced by generation CapEx as the largest rate component between 2020 and 2030. 2. Growth in sales/peak demand/customers, generation CapEx costs, and fuel and purchased power (FPP) costs, in isolation, produce the most uncertainty in rate growth. Specifically, a 1% increase in the compound annual growth rate (CAGR) of retail sales, coincident peak demand (CP), and customers (Sales-CP-Cust) results in a 0.88-0.93% decrease in the CAGR of rates, in isolation. However, a 1% increase in the CAGR of generation CapEx budgets results in a 0.07-0.14% increase in the CAGR of rates, while a 1% increase in the CAGR of FPP costs causes a 0.10-0.14% increase in the CAGR of rates, all else being equal. 3. Taking into account the correlation and variability of the growth in all rate drivers jointly, generation CapEx is expected to be both the largest and most uncertain rate component by 2030 (20-25% share of the retail rate). Transmission and distribution CapEx, along with fuel and purchased power costs are each expected to comprise between 12% and 17% of retail rates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Availability and Performance Loss Factors for U.S. PV Fleet Systems

In the PV Fleet Performance Data Initiative, we partner with photovoltaic (PV) fleet owners to collect time-series PV production data and publish aggregated, anonymized results. This report is an update of our previous publications, specifically a FY 2021 performance index publication and a FY 2022 fleet degradation analysis. In this analysis, we have increased our data participants and system totals by around 10% to 8.5 GW and 24,000 separate inverter data channels. Four major analysis topics are considered in this report: Performance Index (PI) trends, PV system availability, soiling losses, and PV system degradation. Performance Index and inverter availability are assessed on a larger set of data from our FY 2021 report: 1,128 systems compared with 200 systems from before. The increased number of systems is due to an improved data quality methodology, as well as introducing new systems to the analysis. Overall results are similar to previously published values - overall inverter availability is low in the first six months of system performance before reaching steady-state by the end of the first year. Excluding this six-month startup period, system-level aggregated data shows a median (P50) system availability of 0.99 and a lower 10th percentile (P90) value of 0.95 (Figure ES-1). A dependence on system size is also demonstrated, with worse inverter availability results for larger PV systems. Causes of this effect are under investigation, but may be impacted by inverter size, which also show lower availability for larger inverter sizes. This report also investigates PI, correcting for degradation, soiling, snow, and availability. Following these corrections, the median system PI over its entire lifetime is 0.95. PI values reported here are approximately 3% lower than what we presented in our previous FY 2021 report. Soiling loss is assessed in a comprehensive way for the first time in this report. Results are presented using the COmbined Degradation and Soiling (CODS) method, as implemented in RdTools (v3.0.0a4). Soiling values are presented for 255 systems, which indicated irradiance-weighted soiling loss greater than 1%. The values have been published in an updated NREL soiling map at nrel.gov/pv/soiling.html. Finally, we investigated system degradation using three different data analysis techniques: conventional RdTools (year-on-year (YOY)), CODS, and Performance Loss Rate (PLR) analysis. Overall degradation results are consistent with our previous publications. Rerunning conventional RdTools on our updated fleet shows that some data partners have systematically fallen below the median system degradation rate (change over time) of -0.75 %/year. A comparison with PLR analysis, which looks at change in annual PI over time, shows that median system degradation is consistent with -0.5% to -0.75% per year change. However, at the P90 value, system degradation is substantially faster. These two results are consistent and indicate that resulting degradation statistics depend to a great degree on the population of PV systems making up the analysis cohort and whether soiling impacts the systems. The use of CODS for degradation analysis provides a different method for degradation assessment, which explicitly excludes the impact of recoverable soiling on degradation analysis. Excluding soiling effects yields an annual system degradation around -0.5% per year on average. This indicates that a portion of system performance loss may be attributed to periodic soiling that is not fully recovered. This report provides PV system owners/operators with background and methods to analyze PV system performance, give guidance for expected cohort performance, and performance loss values for use in pro-forma financial models, which guide new-build system design and bankability reports.

14 SOLAR ENERGY↗

Regulators’ Financial Toolbox: Leveraging Software as a Service, Cloud Computing, and Artificial Intelligence in Electric Utilities

The rapid evolution of Software as a Service (SaaS), cloud computing, and artificial intelligence (AI) is transforming the electric utility industry, reshaping operations, customer engagement, and financial models. This webinar introduced how utilities can deploy advanced software solutions and AI-driven analytics to improve grid efficiency, optimize asset management, and accurately forecast demand.

Bartlett, Phillip↗

Hualapai Tribal Utility Development Project

The first phase of the Hualapai Tribal Utility Development Project (Project) studied the feasibility of establishing a tribally operated utility to provide electric service to tribal customers at Grand Canyon West (see objective 1 below). The project was successful in completing the analysis of the energy production from the solar power systems at Grand Canyon West and developing a financial model, based on rates to be charged to Grand Canyon West customers connected to the solar systems, that would provide sufficient revenue for a Tribal Utility Authority to operate and maintain those systems. The objective to establish a central power grid over which the TUA would have authority and responsibility had to be modified because the construction schedule of GCW facilities, specifically the new air terminal, did not match up with the construction schedule for the solar power system. Therefore, two distributed systems were constructed instead of one central system with a high voltage distribution network. The Hualapai Tribal Council has not taken the action necessary to establish the Tribal Utility Authority that could be responsible for the electric service at GCW. The creation of a Tribal Utility Authority (TUA) was the subject of the second objective of the project. The second phase of the project examined the feasibility and strategy for establishing a tribal utility to serve the remainder of the Hualapai Reservation and the feasibility of including wind energy from a tribal wind generator in the energy resource portfolio of the tribal utility (see objective 2 below). It is currently unknown when the Tribal Council will consider the implementation of the results of the study. Objective 1 - Develop the basic organizational structure and operational strategy for a tribally controlled utility to operate at the Tribe’s tourism enterprise district, Grand Canyon West. Coordinate the development of the Tribal Utility structure with the development of the Grand Canyon West Power Project construction of the power infrastructure at Grand Canyon West. Develop the maintenance and operations capacity necessary to support utility operations. Develop rates for customers on the Grand Canyon West “mini-grid” sufficient for the tribal utility to be self-sustaining. Establish an implementation strategy for tribal utility service at Grand Canyon West Objective 2 - Develop a strategy for tribal utility takeover of electric service on the Reservation. Perform a cost analysis of Reservation electrical service. Develop an implementation strategy for tribal takeover of Reservation electrical service. Examine options and costs associated with integration of the Tribe’s wind resources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Photovoltaics (PV) as an Eligible Measure in Residential PACE Programs: Benefits and Challenges (Fact Sheet)

Property Assessed Clean Energy (PACE) financing is one of several new financial models broadening access to clean energy by addressing the barrier of initial capital cost. The majority of the PACE programs in the market today include PV as an eligible measure. PV appeals to homeowners as a way to reduce utility bills, self-generate sustainable power, increase energy independence and demonstrate acommitment to the environment. If substantial state incentives for PV exist, PV projects can be economic under PACE, especially when partnered with good net metering policies. At the same time, PV is expensive relative to other eligible measures with a return on investment horizon that might exceed program targets. This fact sheet reviews the benefits and potential challenges of including PV inPACE programs.

14 SOLAR ENERGY↗

Bifacial PV System Performance: Separating Fact from Fiction

The performance of bifacial PV systems depends greatly on the installed conditions. Previous simulations and results have shown very high bifacial gain improvement, but this may not be the case for all conditions, particularly for large-scale systems with self-shading, lower-cost PV modules (PERC) which might have lower bifaciality coefficient, and field deployments over natural ground cover. But not to worry! Financial models indicate that even with these lower performance conditions, and with bifacial gain of 4%-9%, bifacial modules can still provide improved LCOE.

14 SOLAR ENERGY↗

Understanding Bifacial Photovoltaic's Potential

The performance of bifacial PV systems depends greatly on the installed conditions. Previous simulations and results have shown very high bifacial gain improvement, but this may not be the case for all conditions, particularly for large-scale systems with self-shading, lower-cost PV modules (PERC) which might have lower bifaciality coefficient, and field deployments over natural ground cover. But not to worry! Financial models indicate that even with these lower performance conditions, and with bifacial gain of 4%-7%, bifacial modules can still provide improved LCOE.

bifacial↗

Transforming on-grid renewable energy markets. A review of UNDP-GEF support for feed-in tariffs and related price and market-access instruments

As a Global Environment Facility (GEF) founding implementing agency, UNDP has worked on over 230 GEF-supported clean energy projects in close to 100 developing countries since 1992. About 100 of these projects in 80 countries have focused on renewable energy, supported by approximately US $ 293 million in GEF funds and leveraging US $1.48 billion in associated co-financing from national governments, international organizations, the private sector and non-governmental organizations. As part of UNDP efforts to codify and share lessons learnt from these initiatives, this report addresses how scarce public resources can be used to catalyze larger private financial flows for renewable energy. It provides an overview of UNDP-GEF’s extensive work supporting development of national renewable energy policies such as feed-in tariffs. In these activities UNDP-GEF assists developing countries to assess key risks and barriers to technology diffusion and then to identify a mix of policy and financial de-risking measures to remove these barriers and drive investment. This approach is illustrated through three case studies in Uruguay, Mauritius and Kazakhstan. This report is complemented by a companion publication presenting an innovative UNDP financial modeling tool to assist policymakers in appraising different public instruments to promote clean energy.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

A model to determine financial indicators for organic solar cells

Organic solar cells are an emerging photovoltaic technology that is inexpensive and easy to manufacture, despite low efficiency and stability. A model, named TEEOS (Technical and Economic Evaluator for Organic Solar), is presented that evaluates organic solar cells for various solar energy applications in different geographic locations, in terms of two financial indicators, payback period and net present value (NPV). TEEOS uses SMARTS2 software to estimate broadband (280-4000 nm) spectral irradiance data and with the use of a cloud modification factor, predicts hourly irradiation in the absence of actual broadband irradiance data, which is scarce for most urban locations. By using the avoided cost of electricity, annual savings are calculated which produce the financial indicators. It is hoped that these financial indicators can help guide certain technical decisions regarding the direction of research for organic solar cells, for example, increasing efficiency or increasing the absorptive wavelength range. A sample calculation using solar hats is shown to be uneconomical, but a good example of large-scale organic PV production. (author)

14 SOLAR ENERGY↗

Cascading Failures in Interdependent Networks with Multiple Supply-Demand Links and Functionality Thresholds

Various social, financial, biological and technological systems can be modeled by interdependent networks. It has been assumed that in order to remain functional, nodes in one network must receive the support from nodes belonging to different networks. So far these models have been limited to the case in which the failure propagates across networks only if the nodes lose all their supply nodes. In this paper we develop a more realistic model for two interdependent networks in which each node has its own supply threshold, i.e., they need the support of a minimum number of supply nodes to remain functional. In addition, we analyze different conditions of internal node failure due to disconnection from nodes within its own network. We show that several local internal failure conditions lead to similar nontrivial results. When there are no internal failures the model is equivalent to a bipartite system, which can be useful to model a financial market. We explore the rich behaviors of these models that include discontinuous and continuous phase transitions. Using the generating functions formalism, we analytically solve all the models in the limit of infinitely large networks and find an excellent agreement with the stochastic simulations.

97 MATHEMATICS AND COMPUTING↗