Search NASA⌕ Search

SEARCH · Search NASA

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

CarbonSafe II Project: Dryfork Station UW PRB 1 Well Core, Fluid, and Well Logs datasets

This dataset contains the raw data sets of thee UW PRB 1 well's geophysical well logs, core measurements and fluid analysis for the CarbonSafe II project at the Dryfork Station in Gillette, WY. Focus was placed on the Lakota, Hulett and Minnelusa Formations and their overlying seals. Also included are well logs from legacy wells from the surrounding area.

CarbonSafe 2↗

Bubbler Design Updates for Nuclear Safeguards Applications

The accurate monitoring of molten salt is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors and pyropocessing. To attain material accountancy in actinide bearing molten salts, fluid volume and density are needed. Previous work utilized a triple bubbler sensor to measure the fluid level and density in processing tanks. This triple bubbler system utilized three gas dip-tubes strategically positioned at different heights within the molten salt such that the molten salt level, density, and surface tension were determined simultaneously. This investigation explores the effectiveness of an updated bubbler design with larger internal diameters for the dip-tubes to reduce plugging. The findings of this study will provide valuable insights into a bubbler design and configuration for applications in nuclear safeguards. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting objectives in nuclear safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Bubbler Design Updates for Nuclear Safeguards Application

The accurate monitoring of molten salt is crucial for nuclear safeguards, particularly in the context of mixtures used in molten salt reactors and pyropocessing. To attain material accountancy in actinide bearing molten salts, fluid volume and density are needed. Previous work utilized a triple bubbler sensor to measure the fluid level and density in processing tanks. This triple bubbler system utilized three gas dip-tubes strategically positioned at different heights within the molten salt such that the molten salt level, density, and surface tension were determined simultaneously. This investigation explores the effectiveness of an updated bubbler design with larger internal diameters for the dip-tubes to reduce plugging. The findings of this study will provide valuable insights into a bubbler design and configuration for applications in nuclear safeguards. This will contribute to enhanced accountability and transparency in the monitoring of actinide bearing molten salts, promoting objectives in nuclear safeguards.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Multiphase fluid characterization system

A measurement system and method for permitting multiple independent measurements of several physical parameters of multiphase fluids flowing through pipes are described. Multiple acoustic transducers are placed in acoustic communication with or attached to the outside surface of a section of existing spool (metal pipe), typically less than 3 feet in length, for noninvasive measurements. Sound speed, sound attenuation, fluid density, fluid flow, container wall resonance characteristics, and Doppler measurements for gas volume fraction may be measured simultaneously by the system. Temperature measurements are made using a temperature sensor for oil-cut correction.

42 ENGINEERING↗

Note: Precision viscosity measurement using suspended microchannel resonators

We report the characterization of a suspended microchannel resonator (SMR) for viscosity measurements in a low viscosity regime (<10 mPa s) using two measurement schemes. First, the quality factor (Q-factor) of the SMR was characterized with glycerol-water mixtures. The measured Q-factor at 20 Degree-Sign C exhibits a bilinear behavior with the sensitivity of 1281 (mPa s){sup -1} for a lower (1-4 mPa s) and 355 (mPa s){sup -1} for a higher viscosity range (4-8 mPa s), respectively. The second scheme is the vibration amplitude monitoring of the SMR running in a closed loop feedback. When compared in terms of the measurement time, the amplitude-based measurement takes only 0.1 {approx} 1 ms while the Q-factor-based measurement takes {approx}30 s. However, the viscosity resolution of the Q-factor-based measurement is at least three times better than the amplitude-based measurement. By comparing the Q-factors of heavy water and 9.65 wt.% glycerol-water mixture that have very similar viscosities but different densities, we confirmed that the SMR can measure the dynamic viscosity without the density correction. The obtained results demonstrate that the SMR can measure the fluid viscosity with high precision and even real-time monitoring of the viscosity change is possible with the amplitude-based measurement scheme.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fundamental Drop Dynamics and Mass Transfer Experiments to Support Solvent Extraction Modeling Efforts

In support of the Nuclear Energy Advanced Modeling Simulation Safeguards and Separations (NEAMS SafeSep) program, the Idaho National Laboratory (INL) worked in collaboration with Los Alamos National Laboratory (LANL) to further a modeling effort designed to predict mass transfer behavior for selected metal species between individual dispersed drops and a continuous phase in a two phase liquid-liquid extraction (LLE) system. The purpose of the model is to understand the fundamental processes of mass transfer that occur at the drop interface. This fundamental understanding can be extended to support modeling of larger LLE equipment such as mixer settlers, pulse columns, and centrifugal contactors. The work performed at the INL involved gathering the necessary experimental data to support the modeling effort. A custom experimental apparatus was designed and built for performing drop contact experiments to measure mass transfer coefficients as a function of contact time. A high speed digital camera was used in conjunction with the apparatus to measure size, shape, and velocity of the drops. In addition to drop data, the physical properties of the experimental fluids were measured to be used as input data for the model. Physical properties measurements included density, viscosity, surface tension and interfacial tension. Additionally, self diffusion coefficients for the selected metal species in each experimental solution were measured, and the distribution coefficient for the metal partitioning between phases was determined. At the completion of this work, the INL has determined the mass transfer coefficient and a velocity profile for drops rising by buoyancy through a continuous medium under a specific set of experimental conditions. Additionally, a complete set of experimentally determined fluid properties has been obtained. All data will be provided to LANL to support the modeling effort.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

An in-situ conductometric apparatus for physicochemical characterization of solutions and in-line monitoring of separation processes at elevated temperatures and pressures

Specific conductance and frequency-dependent resistance (impedance) data are widely utilized for understanding the physicochemical characteristics of aqueous and non-aqueous fluids and for evaluating the performance of chemical processes. However, the implementation of such an in-situ probe in high-temperature and high-pressure environments is not trivial. This work provides a description of both the hardware and software associated with implementing a parallel-type in-situ electrochemical sensor. The sensor can be used for in-line monitoring of thermal desalination processes and for impedance measurements in fluids at high temperature and pressure. Further, a comparison between the experimental measurements on the specific conductance in aqueous sodium chloride solutions and the conductance model demonstrate that the methodology yields reasonable agreement with both the model and literature data. A combination of hardware components, a software-based correction for experimental artifacts, and computational fluid dynamics (CFD) calculations used in this work provide a sound basis for implementing such in-situ electrochemical sensors to measure frequency-dependent resistance spectra.

47 OTHER INSTRUMENTATION↗

The Sulfur-Iodine Cycle: Process Analysis and Design Using Comprehensive Phase Equilibrium Measurements and Modeling

Of the 100+ thermochemical hydrogen cycles that have been proposed, the Sulfur-Iodine (S-I) Cycle is a primary target of international interest for the centralized production of hydrogen from nuclear power. However, the cycle involves complex and highly nonideal phase behavior at extreme conditions that is only beginning to be understood and modeled for process simulation. The consequence is that current designs and efficiency projections have large uncertainties, as they are based on incomplete data that must be extrapolated from property models. This situation prevents reliable assessment of the potential viability of the system and, even more, a basis for efficient process design. The goal of this NERI award (05-006) was to generate phase-equilibrium data, property models, and comprehensive process simulations so that an accurate evaluation of the S-I Cycle could be made. Our focus was on Section III of the Cycle, where the hydrogen is produced by decomposition of hydroiodic acid (HI) in the presence of water and iodine (I2) in a reactive distillation (RD) column. The results of this project were to be transferred to the nuclear hydrogen community in the form of reliable flowsheet models for the S-I process. Many of the project objectives were achieved. At Clemson University, a unique, tantalum-based, phase-equilibrium apparatus incorporating a view cell was designed and constructed for measuring fluid-phase equilibria for mixtures of iodine, HI, and water (known as HIx) at temperatures to 350 °C and pressures to 100 bar. Such measurements were of particular interest for developing a working understanding of the expected operation of the RD column in Section III. The view cell allowed for the IR observation and discernment of vapor-liquid (VL), liquid-liquid, and liquid-liquid-vapor (LLVE) equilibria for HIx systems. For the I2-H2O system, liquid-liquid equilibrium (LLE) was discovered to exist at temperatures up to 310-315 °C, in contrast to the models and predictions of earlier workers. For the I2-HI-H2O ternary, LLE and LLVE were all observed for the first time at temperatures of 160 and 200 °C. Three LLE tie-lines were measured at 160 °C, and preliminary indications are that the underlying phase behavior could result in further improvements in the performance of the S-I Cycle. Unfortunately, these new results were obtained too late in the project to be incorporated into the modeling and simulation work described below. At the University of Virginia, a uniquely complete and reliable model was developed for the thermodynamic properties of HIx, covering the range of conditions expected for the separation of product hydrogen and recycled iodine in the RD column located in Section III. The model was validated with all available property spectroscopy data. The results provide major advances over prior understanding of the chemical speciation involved. The model was implemented in process simulation studies of the S-I Cycle, which showed improvement in energy efficiency to 42%, as well as significantly smaller capital requirements due to lower pressure operation and much smaller equipment sizes. The result is that the S-I Cycle may be much more economically feasible than was previously thought. If both the experimental and modeling work described above were to be continued to ultimate process optimization, both the American public and the global community would benefit from this alternative energy source that does not produce carbon emissions.

08 HYDROGEN↗

Scalable En Echelon Shear‐Fracture Aperture‐Roughness Mechanism: Theory, Validation, and Implications

Abstract Shear fractures can facilitate fluid conductivity through rock. Aperture and roughness are controlling characteristics for a fracture's fluid conductivity. Inspired by en echelon fractures, we develop a shear “fracturelet” model that predicts anisotropic aperture with respect to the direction of shearing, rougher (nonplanar) rather than smoother (planar) fractures, and the bounds of this roughness for a coalesced fracture. This tendency for rougher fracture creation is validated by in situ X‐ray images and fluid conductivity measurements from triaxial direct shear experiments on anhydrite and shale. These experiments were conducted at confining stresses from 4 to 30 MPa and shear displacement magnitudes from 0 to 2 mm on initially intact rock specimens. Hydraulic, dilatational, and local fracture apertures were measured in the experiments. Apertures exhibited strong anisotropy with more conductive flow paths forming perpendicular to the direction of shearing. Local and dilatational aperture were found to be positively correlated with increasing shear displacement but hydraulic aperture was found to vary significantly, always having values smaller than the other aperture measures at factors ranging from 0.6 to 0.0. An implication of these results is that shear fractures have a mechanism for simultaneously exhibiting very low fluid conductivity and high fluid storage volume.

Frash, Luke P.↗

Mixing in thermally stratified nonlinear spin-up with uniform boundary fluxes

Studies of stratified spin-up experiments in enclosed cylinders have reported the presence of small pockets of well-mixed fluids but quantitative measurements of the mixedness of the fluid has been lacking. Previous numerical simulations have not addressed these measurements. Here we present numerical simulations that explain how the combined effect of spin-up and thermal boundary conditions enhances or hinders mixing of a fluid in a cylinder. The energy of the system is characterized by splitting the potential energy into diabatic and adiabatic components, and measurements of efficiency of mixing are based on both, the ratio of dissipation of available potential energy to forcing and variance of temperature. The numerical simulations of the Navier–Stokes equations for the problem with different sets of thermal boundary conditions at the horizontal walls helped shed some light on the physical mechanisms of mixing, for which a clear explanation was absent.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Speculation on measurements of the viscosity of shocked fluid water

Different reports of the viscosities of shocked water, relying on measurements of ionic drift speeds in dilute aqueous solution, of propagation of corrugations impressed on the shock front, and of the acceleration of entrained cylinders, disagree by six orders of magnitude across overlapping ranges of shock pressure. Measurements made at static pressures have proven that viscosities vary little along the Hugoniot, verifying the results from ionic drift speed. Why the other two proceedures yield such different results has been a matter of speculation. Here, I show reason to believe that the trajectories of the entrained cylinders were in a region of drag in which viscosities of 0.001 Pa-s and 1 Pa-s were experimentally indistinguishable, resulting in much larger supposed viscosities than warranted by the data. It follows that damping of corrugations are best explained as due to dissipative processes distinct from the shear viscosity of the equilibrated fluid.

36 MATERIALS SCIENCE↗

Design and implementation of a shearing apparatus for the experimental study of shear displacement in rocks

Fluid flow in the subsurface is not well understood in the context of “impermeable” geologic media. This is especially true of formations that have undergone significant stress fluctuations due to injection or withdrawal of fluids that alters the localized pressure regime. When the pressure regime is altered, these formations, which are often already fractured, move via shear to reduce the imbalance in the stress state. While this process is known to happen, the evolution of these fractures and their effects on fluid transport are still relatively unknown. Numerous simulation and several experimental studies have been performed that characterize the relationship between shearing and permeability in fractures; while many of these studies utilize measurements of fluid flow or the starting and ending geometries of the fracture to characterize shear, they do not characterize the intermediate stages during shear. We present an experimental apparatus based on slight modifications to a commonly available Hassler core holder that allows for shearing of rocks, while measuring the hydraulic and mechanical changes to geomaterials during intermediate steps. The core holder modification employs the use of semi-circular end caps and structural supports for the confining membrane that allow for free movement of the sheared material while preventing membrane collapse. By integrating this modified core holder with a computed tomography scanner, we show a new methodology for understanding the interdependent behavior between fracture structure and flow properties during intermediate steps in shearing. Here, we include a case study of this device function which is shown here through shearing of a fractured shale core and simultaneous observation of the mechanical changes and evolution of the hydraulic properties during shearing.

58 GEOSCIENCES↗

Method of absorbance correction in a spectroscopic heating value sensor

A method and apparatus for absorbance correction in a spectroscopic heating value sensor in which a reference light intensity measurement is made on a non-absorbing reference fluid, a light intensity measurement is made on a sample fluid, and a measured light absorbance of the sample fluid is determined. A corrective light intensity measurement at a non-absorbing wavelength of the sample fluid is made on the sample fluid from which an absorbance correction factor is determined. The absorbance correction factor is then applied to the measured light absorbance of the sample fluid to arrive at a true or accurate absorbance for the sample fluid.

47 OTHER INSTRUMENTATION↗

Porous Colloidal Nanoparticles as Injectable Multimodal Contrast Agents for Enhanced Geophysical Sensing

Injecting fluids into underground geologic structures is crucial for the development of long-term strategies for managing captured carbon and facilitating sustainable energy extraction operations. Here, we have previously reported that the injection of metal–organic frameworks (MOFs) into the subsurface can enhance seismic monitoring tools to track fluids and map complex structures, reduce risk, and verify containment in carbon storage reservoirs because of their absorption capacity of low-frequency seismic waves. Here, we demonstrate that water-based Cr/Zn/Zr MOF colloidal suspensions (nanofluids) are multimodal geophysical contrast agents that enhance near-wellbore logging tools. Based on experimental fluid-only measurements, MIL-101(Cr), ZIF-8, and UiO-66 nanofluids have distinct complex conductivity and/or low-field nuclear magnetic resonance (NMR) signatures that are relevant to field-deployed technologies, implying the potential to enhance near-wellbore monitoring of CO 2 injection and associated processes with downhole logging tools. Small- and wide-angle X-ray scattering characterization of ~0.5 wt % MIL-101(Cr) suspensions confirmed phase stability and provided insight into the fractal nature of colloidal nanoparticles. Finally, low-field (2 MHz) NMR measurements of MIL-101(Cr) nanofluid injection into a prototypical Berea sandstone demonstrate how paramagnetic high-surface area MOFs may dominate the relaxation times of hydrogen-bearing fluids in porous geologic matrices, enhancing the mapping of near-surface and near-wellbore transport pathways and advancing sustainable subsurface energy technologies.

NMR↗

Influence of Viscous and Capillary Forces on Immiscible Fluid Displacement: Pore-Scale Experimental Study in a Water-Wet Micromodel Demonstrating Viscous and Capillary Fingering

Unstable immiscible fluid displacement in porous media affects geological carbon sequestration, enhanced oil recovery, and groundwater contamination by nonaqueous phase liquids. Characterization of immiscible displacement processes at the pore-scale is important to better understand macroscopic processes at the continuum-scale. A series of displacement experiments was conducted to investigate the impacts of viscous and capillary forces on displacement stability and fluid saturation distributions in a homogeneous water-wet pore network micromodel with precisely-microfabricated pore structures. Displacements were studied using seven wetting-nonwetting fluid pairs with viscosity ratios M (viscosity of the advancing nonwetting fluid divided by the viscosity of the displaced wetting fluid) ranging four orders of magnitude from logM = -1.95 to 1.88. The micromodel was initially saturated with either polyethylene glycol 200 (PEG200) or water as a wetting fluid, which was then displaced by a nonwetting alkane fluid under different flow rates. Capillary numbers (Ca) ranged over four orders of magnitude for the reported experiments, from logCa = -5.88 to -1.02. Fluorescent microscopy was used to visualize displacement and measure nonwetting fluid saturation distributions. These experiments extend the classical work by Lenormand et al. by using water-wet micromodels, high-precision fabrication, and enhanced image analysis of the saturation distributions. In the micromodel experiments initially saturated with PEG200, a viscous wetting fluid, unstable displacement occurred by viscous fingering over the whole range of imposed capillary numbers. For the experiments initially saturated with water, unstable displacement occurred by capillary fingering at low capillary numbers. When the viscous forces were increased by increasing the injection rate, crossover into stable displacement was observed for the fluid pairs with M > 0. For unstable displacement experiments applying the same capillary number for the various fluid pairs, nonwetting fluid saturations were higher when capillary fingering was the dominant fingering process compared to viscous fingering. Our saturation distributions are consistent with other published experimental work and confirm the numerical results obtained by Lenormand et al.

74 ATOMIC AND MOLECULAR PHYSICS↗

Rheological investigation of effect of high temperature on geothermal drilling fluids additives and lost circulation materials

High temperatures (HT) and the corrosive environment make the design of a geothermal drilling fluid a highly complex task. The presence of HT exacerbates the problems due to thermal degradation. Geothermal aquifers usually combine high-temperature and complex chemistry, making them highly corrosive. Although geothermal drilling fluids are exposed to thermal degradation, research of the effect on mud rheological properties in temperatures near or above 149°C (300°F) is limited. In this study, a High Pressure-High Temperature (HPHT) rheology setup was used to measure drilling fluids' properties up to 204.4°C (400°F). Rheological behavior of viscosity, density, lost circulation, and alkalinity control additives were analyzed at HT. It was found experimentally that Bentonite alone is thermally stable at HT. In contrast, Caustic Soda showed a tendency to gelate at temperatures above 93.3°C (200°F), adversely affecting mud rheology. Alkalinity control materials to replace Caustic Soda were evaluated. Among them, Lime presented the best thermal stability at 204.4°C with a range of variation of 0.0024 Pa.s (2.4 cP) on apparent viscosity after three consecutive tests. Besides, it was tested 11 different lost circulation materials (LCM) for understanding their rheological behavior at HT. Further, it was found that HT has less impact on fine granular materials rheological behavior with an average increase of 17.7% compared with the baseline. In contrast, flaky, fibrous, and coarse granular materials presented a more apparent impact in WBM rheology with a deviation of 166% compared with the baseline.

15 GEOTHERMAL ENERGY↗

Optical tweezer measurements of asymptotic nonlinearities in complex fluids

This article presents micro-medium-amplitude oscillatory shear (μMAOS), a method to measure the frequency-dependent micromechanical properties of soft materials in the asymptotically nonlinear regime using optical tweezers. For this work, we have developed a theoretical framework to extract these nonlinear mechanical properties of the material from experimental measurements and also proposed a physical interpretation of the third-order nonlinearities measured in single-tone oscillatory tests. We validate the method using a well-characterized surfactant solution of wormlike micelles, and subsequently employ this technique to demonstrate that the cytoplasm of a living cell undergoes strain softening and shear thinning when locally subjected to weakly nonlinear oscillatory deformations.

59 BASIC BIOLOGICAL SCIENCES↗

Report of Separate Effects Testing for Modeling of Metallic Fuel Casting Process

In order to give guidance regarding the best investment of time and effort in experimental determination of parameters defining the casting process, a Flow-3D model of the casting process was used to investigate the most influential parameters regarding void fraction of the solidified rods and solidification speed for fluid flow parameters, liquid heat transfer parameters, and solid heat transfer parameters. Table 1 summarizes the most significant variables for each of the situations studied. A primary, secondary, and tertiary effect is provided for fluid flow parameters (impacts void fraction) and liquid heat transfer parameters (impacts solidification). In Table 1, the wetting angle represents the angle between the liquid and mold surface as pictured in Figure 1. The viscosity is the dynamic viscosity of the liquid and the surface tension is the property of the surface of a liquid that allows it to resist an external force. When only considering solid heat transfer properties, the variations from case to case were very small. Details on this conclusion are provided in the section considering solid heat transfer properties. The primary recommendation of the study is to measure the fluid flow parameters, specifically the wetting angle, surface tension, and dynamic viscosity, in order of importance, as well as the heat transfer parameters latent heat and specific heat of the liquid alloy. The wetting angle and surface tension can be measured simultaneously using the sessile drop method. It is unclear whether there is a temperature dependency in these properties. Thus measurements for all three parameters are requested at 1340, 1420, and 1500 degrees Celsius, which correspond to the minimum, middle, and maximum temperatures of the liquid alloy during the process. In addition, the heat transfer coefficient between the mold and liquid metal, the latent heat of transformation, and the specific heat of the liquid metal all have strong influences on solidification. These parameters should be measured to achieve better simulation fidelity. Information on all the mentioned parameters is virtually nonexistent. Presently, all the parameters within the casting model are estimates based on pure U, or another alloy such as U-Ni.

36 MATERIALS SCIENCE↗