Search NASA⌕ Search

SEARCH · Search NASA

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Measurements and simulations of focused beam for orthovoltage therapy

Purpose: Megavoltage photon beams are typically used for therapy because of their skin-sparing effect. However, a focused low-energy x-ray beam would also be skin sparing, and would have a higher dose concentration at the focal spot. Such a beam can be produced with polycapillary optics. MCNP5 was used to model dose profiles for a scanned focused beam, using measured beam parameters. The potential of low energy focused x-ray beams for radiation therapy was assessed. Methods: A polycapillary optic was used to focus the x-ray beam from a tungsten source. The optic was characterized and measurements were performed at 50 kV. PMMA blocks of varying thicknesses were placed between optic and the focal spot to observe any variation in the focusing of the beam after passing through the tissue-equivalent material. The measured energy spectrum was used to model the focused beam in MCNP5. A source card (SDEF) in MCNP5 was used to simulate the converging x-ray beam. Dose calculations were performed inside a breast tissue phantom. Results: The measured focal spot size for the polycapillary optic was 0.2 mm with a depth of field of 5 mm. The measured focal spot remained unchanged through 40 mm of phantom thickness. The calculated depth dose curve inside the breast tissue showed a dose peak several centimeters below the skin with a sharp dose fall off around the focus. The percent dose falls below 10% within 5 mm of the focus. It was shown that rotating the optic during scanning would preserve the skin-sparing effect of the focused beam. Conclusions: Low energy focused x-ray beams could be used to irradiate tumors inside soft tissue within 5 cm of the surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The performance of magnetic lens for focusing VCN-SANS.

We have developed a prototype rotating-permanent magnet sextupole lens (named rot-PMSx) for more efficient experiments with neutron beams in time of flight (ToF) mode. This lens can modulate the focusing strength over range 1.5 x 10{sup 4} T/m{sup 2} {le} g' {le} 5.9 x 10{sup 4} T/m{sup 2}. Synchronization between the modulation and the beam pulse produces a focused beam without significant chromatic aberration. We anticipate that this lens could be utilized in focusing small angle neutron scattering (SANS) instruments for novel approach to high resolution SANS. We carried out experiments testing the principle of this lens at the very cold neutron (VCN) beamline (PF2) at Institut Laue-Langevin (ILL), France. The focused beam image size at the detector was kept constant at the same beam size as the source ({approx} 3 mm) over a wavelength range of 30 {angstrom} {le} {lambda} {le} 48 {angstrom} in focal length of {approx} 1.14 m. The flux gain was about 12 relative to a beam without focusing, and the depth of focus was quite large. These results show the good performance of this lens and the system. Thereupon we have demonstrated the performance of this test bed for high resolution focusing of VCN-SANS for a well-studied softmatter sample; a deuterium oxide solution of Pluronic F127, an (PEO){sub 100}(PPO){sub 65}(PEO){sub 100} tri-block copolymer in deuterium oxide. The results of the focusing experiment and the focusing VCN-SANS are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Laser beam induced nanoscale spot through nonlinear “thick” samples: A multi-layer thin lens self-focusing model

Self-focusing is a well-researched phenomenon. Nanoscale spots can be achieved through self-focusing, which is an alternative method for achieving high-density data storage, high-resolution light imaging, and maskless nanolithography. Several research groups have observed that self-focusing spots can be reduced to nanoscale levels via incident laser power manipulation. Self-focusing spots can be analyzed by solving the nonlinear Schrödinger equation and the finite difference time domain method. However, both procedures are complex and time-consuming. In the present work, a multi-layer thin-lens self-focusing model that considers diffraction effects and changes of refractive index along the radial and film thickness directions is proposed to analyze the self-focusing behavior and traveling process of light beams intuitively. The self-focusing behaviors of As{sub 2}S{sub 3} are simulated, and results show that a nanoscale self-focusing spot with a radius of about 0.12 μm can be formed at the bottom of nonlinear sample when the incident laser power exceeds 4.25 mW. Our findings are basically consistent with experimental reports and provide a good method for analyzing and understanding the self-focusing process. An appropriate application schematic design is also provided.

36 MATERIALS SCIENCE↗

Fuzzy control system for a remote focusing microscope

Space Station Crew Health Care System procedures require the use of an on-board microscope whose slide images will be transmitted for analysis by ground-based microbiologists. Focusing of microscope slides is low on the list of crew priorities, so NASA is investigating the option of telerobotic focusing controlled by the microbiologist on the ground, using continuous video feedback. However, even at Space Station distances, the transmission time lag may disrupt the focusing process, severely limiting the number of slides that can be analyzed within a given bandwidth allocation. Substantial time could be saved if on-board automation could pre-focus each slide before transmission. The authors demonstrate the feasibility of on-board automatic focusing using a fuzzy logic ruled-based system to bring the slide image into focus. The original prototype system was produced in under two months and at low cost. Slide images are captured by a video camera, then digitized by gray-scale value. A software function calculates an index of 'sharpness' based on gray-scale contrasts. The fuzzy logic rule-based system uses feedback to set the microscope's focusing control in an attempt to maximize sharpness. The systems as currently implemented performs satisfactorily in focusing a variety of slide types at magnification levels ranging from 10 to 1000x. Although feasibility has been demonstrated, the system's performance and usability could be improved substantially in four ways: by upgrading the quality and resolution of the video imaging system (including the use of full color); by empirically defining and calibrating the index of image sharpness; by letting the overall focusing strategy vary depending on user-specified parameters; and by fine-tuning the fuzzy rules, set definitions, and procedures used.

Weiss, Jonathan J.↗

Design of voice coil motor dynamic focusing unit for a laser scanner

Laser scanning systems have been used for material processing tasks such as welding, cutting, marking, and drilling. However, applications have been limited by the small range of motion and slow speed of the focusing unit, which carries the focusing optics. To overcome these limitations, a dynamic focusing system with a long travel range and high speed is needed. In this study, a dynamic focusing unit for a laser scanning system with a voice coil motor (VCM) mechanism is proposed to enable fast speed and a wide focusing range. The VCM has finer precision and higher speed than conventional step motors and a longer travel range than earlier lead zirconium titanate actuators. The system has a hollow configuration to provide a laser beam path. This also makes it compact and transmission-free and gives it low inertia. The VCM's magnetics are modeled using a permeance model. Its design parameters are determined by optimization using the Broyden–Fletcher–Goldfarb–Shanno method and a sequential quadratic programming algorithm. After the VCM is designed, the dynamic focusing unit is fabricated and assembled. The permeance model is verified by a magnetic finite element method simulation tool, Maxwell 2D and 3D, and by measurement data from a gauss meter. The performance is verified experimentally. The results show a resolution of 0.2 μm and travel range of 16 mm. These are better than those of conventional focusing systems; therefore, this focusing unit can be applied to laser scanning systems for good machining capability.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhanced focus steering abilities of multi-element therapeutic arrays operating in nonlinear regimes

Steering abilities of a typical HIFU therapeutic array operated in linear and nonlinear regimes were compared using numerical simulation with the 3D Westervelt equation. The array included 256 elements of 1.2 MHz frequency and 6.6 mm diameter distributed in a quasi-random pattern over a spherical shell with a 130 mm aperture and a focal length of 120 mm. In the case of linear focusing, thermal effects are proportional to the intensity level and the criterion for safe array operation is that the intensity in the grating lobes should be less than 10% of the intensity in the main focus. In the case of nonlinear focusing, the heating effect is no longer proportional to intensity; therefore the heat deposition rate was chosen as the relevant metric, using the same 10% threshold for the secondary lobe in comparison with the focal maximum. When steering the focus, the same linearly predicted intensity level at the main focus was maintained by increasing the array power. Numerical simulations of the acoustic field were performed for nonlinear propagation both in water and in tissue. It was shown that for shock-forming conditions in the main focus, the steering range of safe electronic focusing is larger than that for linear propagation conditions. Nonlinear sonication regimes therefore can be used to enlarge tissue volumes that can be sonicated using electronic steering of the focus of HIFU arrays.

42 ENGINEERING↗

Focus history of the Hubble Space Telescope: Launch to May 1993

Since the launch of the Hubble Space Telescope (HST) the secondary mirror of the telescope has been moved several times in order to collimate the telescope and also to define a position of best focus. In addition to these moves the focus position changes over time because of water desorption by the graphite epoxy in the metering truss. The authors report here the focus history of the telescope based on a knowledge of the mirror moves made and an analysis of desorption monitoring data obtained by the Faint Object Camera (FOC) in the F/96 mode and of the routine calibration data obtained by the Wide Field and Planetary Cameras. Focus values are extracted using two different methods. In the first method the distance between the center of the point spread function (PSF) and the shadows of the pads supporting the HST primary mirror are related to the focus error. In the second method an analytical formula for the PSF with variable aberration coefficients is fitted to the data. Focus positions derived from the two methods show good agreement. The data show that a desorption of about 83 microns has taken place since Aug. 16, 1990. The desorption has clearly not leveled off as expected from the trend of the earlier data. Long term variations of the secondary mirror position of approximately 3-15 microns from the 'best' focus position have been observed. Variations of the order of 2-5 microns over an orbital period have also been noted. Focus changes resulting from secondary mirror movements greater than approximately 5 microns changes the point spread function significantly and makes deconvolution and quantitative measurements difficult.

Hasan, H.↗

Computerized method and system for designing an aerodynamic focusing lens stack

A computerized method and system for designing an aerodynamic focusing lens stack, using input from a designer related to, for example, particle size range to be considered, characteristics of the gas to be flowed through the system, the upstream temperature and pressure at the top of a first focusing lens, the flow rate through the aerodynamic focusing lens stack equivalent at atmosphere pressure; and a Stokes number range. Based on the design parameters, the method and system determines the total number of focusing lenses and their respective orifice diameters required to focus the particle size range to be considered, by first calculating for the orifice diameter of the first focusing lens in the Stokes formula, and then using that value to determine, in iterative fashion, intermediate flow values which are themselves used to determine the orifice diameters of each succeeding focusing lens in the stack design, with the results being output to a designer. In addition, the Reynolds numbers associated with each focusing lens as well as exit nozzle size may also be determined to enhance the stack design.

47 OTHER INSTRUMENTATION↗

Enhanced relativistic self-focusing of Hermite-cosh-Gaussian laser beam in plasma under density transition

Enhanced and early relativistic self-focusing of Hermite-cosh-Gaussian (HChG) beam in the plasmas under density transition has been investigated theoretically using Wentzel-Kramers-Brillouin and paraxial ray approximation for mode indices m=0, 1, and 2. The variation of beam width parameter with normalized propagation distance for m=0, 1, and 2 is reported, and it is observed that strong self-focusing occurs as the HChG beam propagates deeper inside the nonlinear medium as spot size shrinks due to highly dense plasmas and the results are presented graphically. A comparative study between self-focusing of HChG beam in the presence and absence of plasmas density transition is reported. The dependency of beam width parameter on the normalized propagation distance for different values of decentered parameter “b” has also been presented graphically. For m=0 and 1, strong self-focusing is reported for b=1.8, and for m=2 and b=1.8, beam gets diffracted. The results obtained indicate the dependency of the self-focusing of the HChG beam on the selected values of decentered parameter. Moreover, proper selection of decentered parameter results strong self-focusing of HChG beam. Stronger self-focusing of laser beam is observed due to the presence of plasma density transition which might be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

An estimate of the error caused by the elongation of the wavelength in a focused beam in free-space electromagnetic parameters measurement

A pair of spot-focusing horn lens antenna is the key component in a free-space measurement system. The electromagnetic constitutive parameters of a planar sample are determined using transmitted and reflected electromagnetic beams. These parameters are obtained from the measured scattering parameters by the microwave network analyzer, thickness of the sample, and wavelength of a focused beam on the sample. Free-space techniques introduced by most papers consider the focused wavelength as the free-space wavelength. But in fact, the incident wave projected by a lens into the sample approximates a Gaussian beam, thus, there has an elongation of the wavelength in the focused beam and this elongation should be taken into consideration in dielectric and magnetic measurement. In this paper, elongation of the wavelength has been analyzed and measured. Measurement results show that the focused wavelength in the vicinity of the focus has an elongation of 1%–5% relative to the free-space wavelength. Elongation's influence on the measurement result of the permittivity and permeability has been investigated. Numerical analyses show that the elongation of the focused wavelength can cause the increase of the measured value of the permeability relative to traditionally measured value, but for the permittivity, it is affected by several parameters and may increase or decrease relative to traditionally measured value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Two-dimensional spatiotemporal focusing of femtosecond pulses and its applications in microscopy

We demonstrate and theoretically analyze the two-dimensional spatiotemporal focusing of femtosecond pulses by utilizing a two-dimensional spectral disperser. Compared with spatiotemporal focusing with a diffraction grating, it can achieve widefield illumination with better sectioning ability for a multiphoton excitation process. By utilizing paraxial approximation, our analytical method improves the axial confinement ability and identifies that the free spectra range (FSR) of the two-dimensional spectral disperser affects the out-of-focus multiphoton excitation intensity due to the temporal self-imaging effect. Based on our numerical simulation, a FSR of 50 GHz is necessary to reduce the out-of-focus two-photon excitation by 2 orders of magnitude compared with that in a grating-based spatiotemporal focusing scheme for a 90-fs excitation laser pulse. We build a two-dimensional spatiotemporal focusing microscope using a virtually imaged phased array and achieve an axial resolution of 1.3 μm, which outperforms the resolution of conventional spatiotemporal focusing using a grating by a factor of 1.7, and demonstrate better image contrast inside a tissue-like phantom.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Wave-optical assessment of alignment tolerances in nano-focusing with ellipsoidal mirror

High-precision ellipsoidal mirrors, which can efficiently focus X-rays to the nanometer dimension with a mirror, have not been realized because of the difficulties in the fabrication process. The purpose of our study was to develop nano-focusing ellipsoidal mirrors in the hard X-ray region. We developed a wave-optical focusing simulator for investigating alignment tolerances in nano-focusing with a designed ellipsoidal mirror, which produce a diffraction-limited focus size of 30 × 35 nm{sup 2} in full width at half maximum at an X-ray energy of 7 keV. The simulator can calculate focusing intensity distributions around the focal point under conditions of misalignment. The wave-optical simulator enabled the calculation of interference intensity distributions, which cannot be predicted by the conventional ray-trace method. The alignment conditions with a focal length error of ≲ ±10 µm, incident angle error of ≲ ±0.5 µrad, and in-plane rotation angle error of ≲ ±0.25 µrad must be satisfied for nano-focusing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Tuning the DARHT Axis-II linear induction accelerator focusing

Flash radiography of large hydrodynamic experiments driven by high explosives is a well-known diagnostic technique in use at many laboratories, and the Dual-Axis Radiography for Hydrodynamic Testing (DARHT) facility at Los Alamos produces flash radiographs of large hydrodynamic experiments. Two linear induction accelerators (LIAs) make the bremsstrahlung radiographic source spots for orthogonal views of each test. The 2-kA, 20-MeV Axis-I LIA creates a single 60-ns radiography pulse. The 1.7-kA, 16.5-MeV Axis-II LIA creates up to four radiography pulses by kicking them out of a longer pulse that has a 1.6-μs flattop. The Axis-II injector, LIA, kicker, and downstream transport (DST) to the bremsstrahlung converter are described. Adjusting the magnetic focusing and steering elements to optimize the electron-beam transport through an LIA is often called 'tuning.' As in all high-current LIAs, the focusing field is designed to be as close to that of the ideal continuous solenoid as physically possible. In ideal continuous solenoidal transport a smoothly varying beam size can easily be found for which radial forces balance, and the beam is said to be 'matched' to the focusing field. A 'mismatched' beam exhibits unwanted oscillations in size, which are a source of free energy that contributes to emittance growth. This is undesirable, because in the absence of beam-target effects, the radiographic spot size is proportional to the emittance. Tuning the Axis-II LIA is done in two steps. First, the solenoidal focusing elements are set to values designed to provide a matched beam with little or no envelope oscillations, and little or no beam-breakup (BBU) instability growth. Then, steering elements are adjusted to minimize the motion of the centroid of a well-centered beam at the LIA exit. This article only describes the design of the tune for the focusing solenoids. The DARHT Axis-II LIA was required to be re-tuned after installing an accelerator cell to replace a failed solenoid in March of 2012. We took advantage of this opportunity to improve the design of the focusing tune with better models of the remaining partially failed solenoids, better estimates of beam initial conditions, and better values for pulsed-power voltages. As with all previous tunes for Axis-II, this one incorporates measures to mitigate beam-breakup (BBU) instability, image displacement instability (IDI), corkscrew (sweep), and emittance growth. Section II covers the general approach to of design of focusing solenoid tunes for the DARHT Axis-2 LIA. Section III explains the specific requirements and simulations needed to design the tune for the injector, which includes the thermionic electron source, diode, and six induction cells. Section IV explains the requirements and simulations for tuning the main accelerator, which consists of 68 induction cells. Finally, Section V explores sensitivity of the tune to deviations of parameters from nominal, random variations, and uncertainties in values. Four appendices list solenoid settings for this new tune, discuss comparisons of different simulation codes, show halo formation in mismatched beams, and present a brief discussion of the beam envelope equation, which is the heart of the method used to design LIA solenoid tunes.

43 PARTICLE ACCELERATORS↗

Flying focus: Spatial and temporal control of intensity for laser-based applications

An advanced focusing scheme, called a "flying focus," uses a chromatic focusing system combined with a broadband laser pulse with its colors arranged in time to propagate a high intensity focus over a distance that can be much greater than its Rayleigh length, while decoupling the speed at which the peak intensity propagates from its group velocity. The flying focus generates a short effective pulse duration with a small diameter focal spot that co- or counter-propagates along the optical axis at any velocity. Experiments validating the concept measured subluminal (–0.09c) to superluminal (39c) focal spot velocities with a nearly constant peak intensity over 4.5 mm. Experiments that increased the peak intensity above the ionization threshold for gas demonstrated ionization waves propagating at the velocity of the flying focus. Here these ionization waves of any velocity overcome several laser-plasma propagation issues, including ionization-induced refraction. The flying focus presents opportunities to overcome current fundamental limitations in laser-plasma amplifilers, laser wakefield accelerators, photon accelerators, and high-order frequency conversion.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Intense gamma-ray source based on focused electron beams from a laser wakefield accelerator

Laser wakefield accelerators generate ultrashort electron bunches with the capability to produce γ-rays. Here, we produce focused laser wakefield acceleration electron beams using three quadrupole magnets. Electron beams are then focused into a 3 mm lead converter to generate intense, focused bremsstrahlung γ beams. Experimental results demonstrate the generation and propagation of focused γ beams to a best focus spot size of 2.3 ± 0.1 × 2.7 ± 0.2 mm 2 using a copper stack calorimeter. Monte Carlo simulations conducted using GEANT4 are in good agreement with experimental results and enable detailed examination of γ-ray generation. Simulations indicate that the focused γ beams contained 2.6 × 10 9 photons in the range of 100 keV to 33 MeV with an average energy of 6.4 MeV. A γ-ray intensity of 7 × 10 10 W/cm 2 was estimated from simulations. In conclusion, the generation of focused bremsstrahlung γ-ray sources can have important applications in medical imaging applications and laboratory astrophysics experiments.

43 PARTICLE ACCELERATORS↗

Radiation by a laser-driven flying-focus electron wave packet

An exact solution of the Dirac equation in the presence of an arbitrary electromagnetic plane wave is found, which corresponds to a focused electron wave packet, with the focus of the wave packet moving at the speed of light in the opposite direction of the average momentum of the electron wave packet (unless the plane wave is so intense to reflect the electron). The photon spectrum emitted by such an electron wave packet in the presence of a linearly polarized plane wave is studied both analytically and numerically. The spectrum is also compared with the one emitted by a single-momentum, plane-wave electron in the case of the electron being initially counterpropagating (on average for the flying-focus case) with the plane wave and within the locally constant field approximation. It is found that if the electron flying-focus wave packet is focused beyond a Compton wavelength, the angular distribution of the emitted radiation along the magnetic field of the electromagnetic plane wave is broader than for an electron with definite momentum. Corresponding the maximum value of the photon yield on the transverse plane is smaller in the flying-focus electron case. This could represent an experimental signature of a laser-driven flying-focus electron wave packet.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SU-D-304-02: Magnetically Focused Proton Irradiation of Small Field Targets

Purpose: To investigate the use of magnetic focusing for small field proton irradiations. It is hypothesized that magnetic focusing will provide significant dose distribution benefits over standard collimated beams for fields less than 10 mm diameter. Methods: Magnets consisting of 24 segments of radiation hard samarium-cobalt adhered into hollow cylinders were designed and manufactured. Two focusing magnets were placed on a positioning track on our Gantry 1 treatment table. Proton beams with energies of 127 and 157 MeV, 15 and 30 mm modulation, and 8 mm initial diameters were delivered to a water tank using single-stage scattering. Depth dose distributions were measured using a PTW PR60020 diode detector and transverse profiles were measured with Gafchromic EBT3 film. Monte Carlo simulations were also performed - both for comparison with experimental data and to further explore the potential of magnetic focusing in silica. For example, beam spot areas (based on the 90% dose contour) were matched at Bragg depth between simulated 100 MeV collimated beams and simulated beams focused by two 400 T/m gradient magnets. Results: Preliminary experimental results show 23% higher peak to entrance dose ratios and flatter spread out Bragg peak plateaus for 8 mm focused beams compared with uncollimated beams. Monte Carlo simulations showed 21% larger peak to entrance ratios and a ∼9 fold more efficient dose to target delivery compared to spot-sized matched collimated beams. Our latest results will be presented. Conclusion: Our results suggest that rare earth focusing magnet assemblies could reduce skin dose and beam number while delivering dose to nominally spherical radiosurgery targets over a much shorter time compared to unfocused beams. Immediate clinical applications include those associated with proton radiosurgery and functional radiosurgery of the brain and spine, however expanded treatment sites can be also envisaged.

60 APPLIED LIFE SCIENCES↗

Changes in the dark focus of accommodation associated with simulator sickness

The relationship between the dark focus of accommodation and simulator sickness, a form of motion sickness, was examined in three experiments. In Experiment 1, dark focus was measured in 18 college students in a laboratory setting before and after they viewed a projected motion scene depicting low altitude helicopter flight. In Experiments 2 and 3, dark focus was measured in pilots (N = 16 and 23, respectively) before and after they 'flew' in moving-base helicopter flight simulators with optical infinity CRT visual systems. The results showed that individuals who experienced simulator sickness had either an inward (myopic) change in dark focus (Experiments 1 and 3) or attenuated outward shifts in dark focus (Experiment 2) relative to participants who did not get sick. These results are consonant with the hypothesis that parasympathetic activity, which may be associated with simulator sickness, should result in changes in dark focus that are in a myopic direction. Night vision goggles, virtual environments, extended periods in microgravity, and heads-up displays all produce related visual symptomatology. Changes in dark focus may occur in these conditions, as well, and should be measured.

Fowlkes, Jennifer E.↗