Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREON”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Comparison of flight measurements with predictions from aeroelastic models in the NASA Langley Transonic Dynamics Tunnel

The NASA Langley Transonic Dynamics Tunnel, which has a variable density, Freon-12 (or air) test medium, was designed to study the dynamics and aeroelastic problems of aerospace vehicles. During the operation of this facility there have been various opportunities to compare wind tunnel and flight test results. Some of these opportunities arise from routine flight checks of the prototype, others from carefully designed comparative wind tunnel and flight experiments. A collection of data obtained from various published and unpublished sources is presented. The topics covered are: gust and buffet response, control surface effectiveness, flutter, and active control of aeroelastic effects. Some benefits and shortcomings of Freon-12 as a test medium are also discussed. Although areas of uncertainty are evident and there is a continuing need for improvements in model simulation and testing techniques, the results presented herein indicate that predictions from aeroelastic model tests are, in general, substantiated by full-scale flight tests.

Reed, W. H., III↗

Deployable Heat Pipe Radiator

A 1.2- by 1.8-m variable conductance heat pipe radiator was designed, built, and tested. The radiator has deployment capability and can passively control Freon-21 fluid loop temperatures under varying loads and environments. It consists of six grooved variable conductance heat pipes attached to a 0.032-in. aluminum panel. Heat is supplied to the radiator via a fluid header or a single-fluid flexible heat pipe header. The heat pipe header is an artery design that has a flexible section capable of bending up to 90 degrees. Radiator loads as high as 850 watts were successfully tested. Over a load variation of 200 watts, the outlet temperature of the Freon-21 fluid varied by 7 F. An alternate control system was also investigated which used a variable conductance heat pipe header attached to the heat pipe radiator panel.

Edelstein, F.↗

Flat plate electrohydrodynamic heat pipe experiments

Performance capabilities of electrohydrodynamic (EHD) flat heat pipes were investigated using Freon 113 and Freon 11 as working fluids. All of the pipes employed straight rod electrodes to form axial liquid flow channels and tranverse grooves for capillary surface wetting. Results show: (1) the EHD pipe will prime under load, (2) voltage controlled conductance can be achieved by varying the active area of the evaporator, and (3) the average evaporator conductances measured in these experiments were consistent with those obtained in other experiments with heat pipes of similar surface geometry using the same or similar working fluids.

Loehrke, R. I.↗

Development of thermal stratification and destratification scaling concepts. Volume 2: Stratification

Temperature and pressure data obtained from the saturated Freon 113 PCA closed-tank stratification tests are presented. The data presented in tabular form are the test conditions, sensible heat values, and Freon 113 PCA liquid and ullage (vapor) properties. Also included, are graphical representations of the liquid bulk temperature and pressure histories, and dimensionless liquid-ullage delta-temperature profiles. Modified Grashof numbers and Fourier number-history data are also presented graphically.

Lovrich, T. N.↗

Comparisons of flight measurements with predictions from aeroelastic models in the NASA Langley Transonic Dynamics Tunnel

The NASA Langley Transonic Dynamics Tunnel, which has a variable density Freon-12 (or air) test medium, was designed for the study of dynamics and aeroelastic problems of aerospace vehicles. During the 15 years of operation of this facility there have been various opportunities to compare wind tunnel and flight test results. Some of these opportunities arise from routine flight checks of the prototype, others from carefully designed comparative wind tunnel and flight experiments. Data obtained from various sources is presented. The topics covered are: gust and buffet response, control surface effectiveness, flutter, and active control of aeroelastic effects. Some benefits and shortcomings of Freon-12 as a test medium are also discussed. Although areas of uncertainly are evident and there is a continuing need for improvements in model simulation and testing techniques, the results indicate that predictions from aeroelastic model tests are, in general, substantiated by full scale flight tests.

Reed, W. H., III↗

Correlation with flight of some aeroelastic model studies in the NASA Langley transonic dynamics tunnel

The NASA Langley transonic dynamics tunnel, which has a variable density Freon-12 (or air) test medium, was designed specifically for the study of dynamics and aeroelastic problems of aerospace vehicles. During the 15 years of operation of this facility, there have been various opportunities to compare wind tunnel and flight test results. Some of these opportunities arise from routine flight checks of the prototypes; others, from carefully designed comparative wind-tunnel and flight experiments. Such data obtained from various published and unpublished sources are presented. The topics covered are: gust and buffet response, control surface effectiveness, flutter, and active control of aeroelastic effects. Some benefits and shortcomings of Freon-12 as a test medium are also discussed. Although areas of uncertainty are evident and there is a continuing need for improvements in model simulation and testing techniques, the results presented indicate that predictions from aeroelastic model tests are, in general, substantiated by full scale flight tests.

Reed, W. H., III↗

Spacecraft disinfectant/cleansing agent development

The sanitation agent container, which was selected in a trade off study, employs two chambers, a rigid outer container and an inner flexible bladder. The bladder contains the sanitation agent formulation and its release is controlled by a manually operated valve. The outer container holds a high pressure vapor. There is no void in the bladder which makes the package operation independent of orientation and therefore usable in zero gravity. Foam is developed by a low boiling point fluid or dissolved in the product. When the product is dispensed at atmospheric presure, the evolved gas or vapor whips up a goam in the valve. The sanitation agents were initially formulated with freons which produces an excellent foam. However freon is incompatible with the life support system and was replaced with carbon dioxide dissolved at high pressure. The CO2 system may limit high temperature exposure to prevent leakage or package distortion. The sanitation agents have been shown to be effective in cleaning soils from personnel and material.

Abbate, M.↗

Tabulation and summary of thermodynamic effects data for developed cavitation on ogive-nosed bodies

Thermodynamic effects data for developed cavitation on zero and quarter caliber ogives in Freon 113 and water are tabulated and summarized. These data include temperature depression (delta T), flow coefficient (C sub Q), and various geometrical characteristics of the cavity. For the delta T tests, the free-stream temperature varied from 35 C to 95 C in Freon 113 and from 60 C to 125 C in water for a velocity range of 19.5 m/sec to 36.6 m/sec. Two correlations of the delta T data by the entrainment method are presented. These correlations involve different combinations of the Nusselt, Reynolds, Froude, Weber, and Peclet numbers and dimensionless cavity length.

Holl, J. W.↗

Generalized environmental control and life support system computer program (G1894), phase 3

The work performed during Phase 3 of the Generalized Environmental Control Life Support System (ECLSS) Computer Program is reported. Phase 3 of this program covered the period from December 1977 to September 1978. The computerized simulation of the Shuttle Orbiter ECLSS was upgraded in the following areas: (1) the payload loop of the Shuttle simulation was completely recoded and checked out; (2) the Shuttle simulation water and freon loop initialization logic was simplified to permit easier program input for the user; (3) the computerized simulation was modified to accept the WASP subroutine, which is a subroutine to evaluate thermal properties of water and freon; (4) the 1108 operating system was upgraded by LEC; (5) the Shuttle simulation was modified to permit failure cases which simulate zero component flow values; and (6) the Shuttle SEPS version was modified and secure files were setup on the 1108 and 1110 systems to permit simulation runs to be made from remote terminals.

Mcenulty, R. E.↗

Validation of scramjet exhaust simulation technique at Mach 6

Current design philosophy for hydrogen-fueled, scramjet-powered hypersonic aircraft results in configurations with strong couplings between the engine plume and vehicle aerodynamics. The experimental verification of the scramjet exhaust simulation is described. The scramjet exhaust was reproduced for the Mach 6 flight condition by the detonation tube simulator. The exhaust flow pressure profiles, and to a large extent the heat transfer rate profiles, were then duplicated by cool gas mixtures of Argon and Freon 13B1 or Freon 12. The results of these experiments indicate that a cool gas simulation of the hot scramjet exhaust is a viable simulation technique except for phenomena which are dependent on the wall temperature relative to flow temperature.

Hopkins, H. B.↗

Correlations of thermodynamic effects for developed cavitation

The net positive suction head (NPSH) requirements for a pump are determined by the combined effects of cavitation, fluid properties, pump geometry, and pump operating point. An important part of this determination is the temperature depression (Delta T). Correlations are presented of the temperature depression for various degrees of developed cavitation on venturis and ogives. These correlations, based on a semi-empirical entrainment theory, express Delta T in terms of the dimensionless numbers of Nusselt, Reynolds, Froude, Weber, and Peclet, and dimensionless cavity length (L/D). The Delta T data were obtained in Freon 114, hydrogen and nitrogen for the venturis and in Freon 113 and water for the ogives.

Billet, M. L.↗

Shuttle orbiter flash evaporator operational flight test performance

The Flash evaporator System (FES is part of the Shuttle Orbiter Active Thermal Control Subsystem. The FES provides total heat rejection for the vehicle Freon Coolant Loops during ascent and entry and supplementary heat rejection during orbital mission phases. This paper reviews the performance of the FES during the first two Shuttle orbital missions (STS-1 and STS-2). A comparison of actual mission performance against design requirements is presented. Mission profiles (including Freon inlet temperature and feedwater pressure transients), control temperature, and heat load variations are evaluated. Anomalies that occurred during STS-2 are discussed along with the procedures conducted, both in-flight and post-flight, to isolate the causes. Finally, the causes of the anomalies and resulting corrective action taken for STS-3 and subsequent flights are presented.

Nason, J. R.↗

Partial Analysis of Insta-Foam

Insta-Foam, used as a thermal insulator for the non-critical area of the external tank during the prelaunch phase to minimize icing, is a two-component system. Component A has polyisocyanates, blowing agents, and stabilizers; Component B has the polyols, catalysts, blowing agents, stabilizers and fire retardant. The blowing agents are Freon 11 and Freon 12, the stabilizers are silicone surfactants, the catalysts are tertiary amines, and the fire retardant is tri-(beta-chloro-isopropyl) phosphate (PCF). High performance liquid chromatography (HPLC) was quantitatively identified polyols and PFC.

Chou, L. W.↗

Use of two-phase flow heat transfer method in spacecraft thermal system

In space applications, weight, volume and power are critical parameters. Presently liquid freon is used in the radiator planels of the Space Shuttle to dissipate heat. This requires a large amount of freon, large power for pumps, large volume and weight. Use of two-phase flow method to transfer heat can reduce them significantly. A modified commercial vapor compression refrigerator/freezer was sucessfully flown in STS-4 to study the effect of zero-gravity on the system. The duty cycle was about 5 percent higher in flight as compared to that on earth due to low flow velocity in condenser. The vapor Reynolds number at exit was about 4000 as compared to about 12,000. Efforts are underway to design a refrigerator/freezer using an oil-free compressor for Spacelab Mission 4 scheduled to fly in January 1986. A thermal system can be designed for spacecraft using the two-phase flow to transfer heat economically.

Hye, A.↗

Measurements and predictions of the structure of evaporating sprays

In the present experimental and theoretical study of turbulent, evaporating sprays, round, Freon-11 sprays produced by an air-atomizing injector that is directed vertically downward in still air were subjected to structure measurements for mean and fluctuating gas velocities, total Freon-11 concentration, drop size and velocity contributions, mean gas temperature, and liquid flux distributions. An evaluation was then conducted of three spray models: (1) locally homogeneous flow, (2) deterministic separated flow, and (3) stochastic separated flow. The first two of these were found to perform poorly; the stochastic model yielded the best agreement between predictions and measurements.

Solomon, A. S. P.↗

Aeroelastic model helicopter rotor testing in the Langley TDT

Wind-tunnel testing of a properly scaled aeroelastic model helicopter rotor is considered a necessary phase in the design development of new or existing rotor systems. For this reason, extensive testing of aeroelastically scaled model rotors is done in the Transonic Dynamics Tunnel (TDT) located at the NASA Langley Research Center. A unique capability of this facility, which enables proper dynamic scaling, is the use of Freon as a test medium. A description of the TDT and a discussion of the benefits of using Freon as a test medium are presented. A description of the model test bed used, the Aeroelastic Rotor Experimental System (ARES), is also provided and examples of recent rotor tests are cited to illustrate the advantages and capabilities of aeroelastic model rotor testing in the TDT. The importance of proper dynamic scaling in identifying and solving rotorcraft aeroelastic problems, and the importance of aeroelastic testing of model rotor systems in the design of advanced rotor systems are demonstrated.

Mantay, W. R.↗

SSME Long-life Bearings

Hybrid hydrostatic/ball bearings for LH2 and LO2 service in turbopumps were studied as a means of improving speed and life capabilities. Four hybrid bearing configurations were designed with emphasis on achieving maximum stiffness and damping. Parallel load bearings were tested at steady-state and transient conditions with LH2 (externally fed) and LN2 (internally fed). The hydrostatic elements were tested with Freon 113 for empirical determination of dynamic characteristics. Tests using an eccentric journal for loading showed the externally and internally fed hydrostatic bearings to have significant separated coefficients of direct stiffness and damping. For the internally fed bearing, the strongly speed-dependent cross-coupling stiffness arising from fluid swirl, along with significant cross-coupling damping, resulted in low net effective stiffness and damping. The test method used can produce separated coefficients with a sufficiently elliptic journal orbit; otherwise, only net effective coefficients combining direct and cross-coupling terms can be determined. Testing with nonsynchronous excitation is recommended to avoid this restriction. Investigation of hard materials, including ceramics, is recommended as a means of eliminating the need for the rolling bearing for startup and shutdown support. The testing was performed in 1984 (LH2), 1985 (LN2) and 1985-86 (Freon).

Butner, M. F.↗

Aeroelastic model helicopter rotor testing in the Langley TDT

Wind-tunel testing of a properly scaled aeroelastic model helicopter rotor is considered a necessary phase in the design development of new or existing rotor systems. For this reason, extensive testing of aeroelastically scaled model rotors is done in the Transonic Dynamics Tunnel (TDT) located at the NASA Langley Research Center. A unique capability of this facility, which enables proper dynamic scaling, is the use of Freon as a test medium. A description of the TDT and a discussion of the benefits of using Freon as a test medium are presented. A description of the model test bed used, the Aeroelastic Rotor Experimental System (ARES), is also provided and examples of recent rotor tests are cited to illustrate the advantages and capabilities of aeroelastic model rotor testing in the TDT. The importance of proper dynamic scaling in identifying and solving rotorcraft aeroelastic problems, and the importance of aeroelastic testing of model rotor systems in the design of advanced rotor systems are demonstrated.

Mantay, W. R.↗