Search NASA⌕ Search

SEARCH · Search NASA

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A two-year history of atomic frequency standards syntonization in the Deep Space Network

The frequency and timing system (FTS) of the Deep Space Network (DSN) consists of a collection of three sets of clocks driven by independent atomic oscillators. The synchronization of the output frequencies (syntonization) of these oscillators (reference frequency standards) is reported. There is an implied specification of a + or - 5.5 X 10 to the 12th power related to the DSN time synchronization specification of a + or - 100 microseconds. Both the syntonization within the three sets and the syntonization of the sets to the international standard (International Atomic Time) are considered.

Ward, S. C.↗

Mercury Atomic Frequency Standards for Space Based Navigation and Timekeeping

A low power Mercury Atomic Frequency Standard (MAFS) has been developed and demonstrated on the path towards future space clock applications. A self contained mercury ion breadboard clock: emulating flight clock interfaces, steering a USO local oscillator, and consuming approx 40 Watts has been operating at JPL for more than a year. This complete, modular ion clock instrument demonstrates that key GNSS size, weight, and power (SWaP) requirements can be achieved while still maintaining short and long term performance demonstrated in previous ground ion clocks. The MAFS breadboard serves as a flexible platform for optimizing further space clock development and guides engineering model design trades towards fabrication of an ion clock for space flight.

Global Positioning Systems (GPS)↗

Acousto-optic modulators for a controlled frequency shift of light beams in optical and microwave cold-atom frequency standards

A series of specialised acousto-optic modulators/frequency shifters based on paratellurite (TeO{sub 2}) single crystals is developed for systems of laser cooling and frequency stabilisation of laser sources in optical and microwave frequency standards based on cold strontium, rubidium and caesium atoms. The methods of calculation and optimisation of the main parameters of acousto-optic modulators are considered; their basic technical characteristics are experimentally investigated in the spectral range of optical radiation 460 – 900 nm and in the frequency shift range of 5 – 400 MHz. The modulators have a high diffraction efficiency, low power consumption and the ability to work with linearly and randomly polarised optical radiation. (frequency standards)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Environmental Tests Of Cesium Frequency Standards

Report describes environmental tests of cesium-beam frequency standards of United States Naval Observatory. Purpose of tests to determine effects of atmospheric temperature, relative humidity, and pressure on frequencies.

Sydnor, Richard L.↗

Laser induced asymmetry and inhomogeneous broadening of the microwave lineshape of a gas cell atomic frequency standard

The possibility of replacing the RF discharge lamp in a rubidium gas cell clock with a single mode laser diode is addressed. Since the short term stability of the rubidium frequency standard is limited by the shot noise of the photodetector, an increased signal-to-noise ratio due to more efficient laser diode optical pumping might improve the short term performance. Because the emission wavelength of the laser diode can be tuned, improved long term performance could be gained through the control of the light shift effect. However, due to the nature of the gas cell frequency standard, various physical phenomena are strongly coupled in their effect on the frequency output, and thus careful consideration must be given to any change in one parameter because of its interrelation with other parameters. Some investigations concerning the coupled effect of the optical and microwave fields in the rubidium atomic clock are reported. It is shown that this type of coupling is an important consideration for any attempt to incorporate a laser diode into a gas cell clock.

Camparo, J. C.↗

Potential of electric quadrupole transitions in radium isotopes for single-ion optical frequency standards

We explore the potential of the electric quadrupole transitions 7s {sup 2}S{sub 1/2}-6d {sup 2}D{sub 3/2}, 6d {sup 2}D{sub 5/2} in radium isotopes as single-ion optical frequency standards. The frequency shifts of the clock transitions due to external fields and the corresponding uncertainties are calculated. Several competitive {sup A}Ra{sup +} candidates, with A= 223-229, are identified. In particular, we show that the transition 7s {sup 2}S{sub 1/2} (F=2,m{sub F}=0)-6d {sup 2}D{sub 3/2} (F=0,m{sub F}=0) at 828 nm in {sup 223}Ra{sup +}, with no linear Zeeman and electric quadrupole shifts, stands out as a relatively simple case, which could be exploited as a compact, robust, and low-cost atomic clock operating at a fractional frequency uncertainty of 10{sup -17}. With more experimental effort, the {sup 223,225,226}Ra{sup +} clocks could be pushed to a projected performance reaching the 10{sup -18} level.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Influence of modulation frequency in rubidium cell frequency standards

The error signal which is used to control the frequency of the quartz crystal oscillator of a passive rubidium cell frequency standard is considered. The value of the slope of this signal, for an interrogation frequency close to the atomic transition frequency is calculated and measured for various phase (or frequency) modulation waveforms, and for several values of the modulation frequency. A theoretical analysis is made using a model which applies to a system in which the optical pumping rate, the relaxation rates and the RF field are homogeneous. Results are given for sine-wave phase modulation, square-wave frequency modulation and square-wave phase modulation. The influence of the modulation frequency on the slope of the error signal is specified. It is shown that the modulation frequency can be chosen as large as twice the non-saturated full-width at half-maximum without a drastic loss of the sensitivity to an offset of the interrogation frequency from center line, provided that the power saturation factor and the amplitude of modulation are properly adjusted.

Audoin, C.↗

A miniature tactical Rb frequency standard

Work on an innovative design for miniature rubidium frequency standards has reached the pre-production demonstration stage at Litton Guidance and Control Systems. Pre-production units were built and tested under contract to the Rome Air Development Center of the U.S. Air Force Systems Command. The units, which are designed for use in tactical military applications, feature fast warm-up, low power consumption, and vibration insensitivity. The output stability under vibration is maintained without the need for external shock-mounts. The design objectives and test results are discussed.

Kwon, T. M.↗

Indium Single-Ion Frequency Standard

A single laser-cooled indium ion is a promising candidate for an ultimate resolution optical time or frequency standard. It can be shown that single ions from group IIIA of the periodic table (indium, thallium, etc.) can have extremely small systematic errors. In addition to being free from Doppler, transit-time and collisional shifts, these ions are also quite insensitive to perturbations from ambient magnetic and electric fields (mainly due to the use of a J=0-0 transition for spectroscopy). Of all group IIIA ions, indium seems to be the most practical, since it is heavy enough to have a tolerable intercombination cooling transition rate and (unlike thallium) has transitions which are easily accessible with frequency multiplied continuous-wave lasers. A single indium ion standard has a potential inaccuracy of one part in 10(exp 18) for integration times of 10(exp 6) seconds. We have made substantial progress during the grant period in constructing a frequency standard based upon a single indium ion. At the beginning of the grant period, single indium ions were being successfully trapped, but the lasers and optical systems were inadequate to achieve the desired goal. We have considerably improved the stability of the dye laser used to cool the ions and locked it to a molecular resonance line, making it possible to observe stable cooling-line fluorescence from a single indium ion for reasonable periods of time, as required by the demands of precision spectroscopy. We have substantially improved the single-ion fluorescence signal with significant benefits for the detection efficiency of forbidden transitions using the 'shelving' technique. Finally, we have constructed a compact, efficient UV 'clock' laser and observed 'clock' transitions in single indium ions using this laser system. We will elaborate on these accomplishments.

Nagourney, Warren↗

Investigations of laser pumped gas cell atomic frequency standard

The performance characteristics of a rubidium gas cell atomic frequency standard might be improved by replacing the standard rubidium discharge lamp with a single mode laser diode. Aspects of the laser pumped gas cell atomic clock studied include effects due to laser intensity, laser detuning, and the choice of the particular atomic absorption line. Results indicate that the performance of the gas cell clock may be improved by judicious choice of the operating parameters of the laser diode. The laser diode also proved to be a valuable tool in investigating the operation of the conventional gas cell clock. Results concerning linewidths, the light shift effect and the effect of isotopic spin exchange in the conventional gas cell clock are reported.

Volk, C. H.↗

Providing hydrogen maser timing stability to orbiting VLBI radio telescope observations by post-measurement compensation of linked frequency standard imperfections

Orbiting VLBI (OVLBI) astronomical observations are based upon measurements acquired simultaneously from ground-based and earth-orbiting radio telescopes. By the mid-1990s, two orbiting VLBI observatories, Russia's Radioastron and Japan's VSOP, will augment the worldwide VLBI network, providing baselines to earth radio telescopes as large as 80,000 km. The challenge for OVLBI is to effectuate space to ground radio telescope data cross-correlation (the observation) to a level of integrity currently achieved between ground radio telescopes. VLBI radio telescopes require ultrastable frequency and timing references in order that long term observations may be made without serious cross-correlation loss due to frequency source drift and phase noise. For this reason, such instruments make use of hydrogen maser frequency standards. Unfortunately, space-qualified hydrogen maser oscillators are currently not available for use on OVLBI satellites. Thus, the necessary long-term stability needed by the orbiting radio telescope may only be obtained by microwave uplinking a ground-based hydrogen maser derived frequency to the satellite. Although the idea of uplinking the frequency standard intrinsically seems simple, there are many 'contaminations' which degrade both the long and short term stability of the transmitted reference. Factors which corrupt frequency and timing accuracy include additive radio and electronic circuit thermal noise, slow or systematic phase migration due to changes of electronic circuit temporal operating conditions (especially temperature), ionosphere and troposphere induced scintillations, residual Doppler-incited components, and microwave signal multipath propagation. What is important, though, is to realize that ultimate stability does not have to be achieved in real-time. Instead, information needed to produce a high degree of coherence in the subsequent cross-correlation operation may be derived from a two-way coherent radio link, recorded and later introduced as compensations adjunct to the VLBI correlation process. Accordingly, this paper examines the technique for stable frequency/time transfer within the OVLBI system, together with a critique of the types of link degradation components which must be compensated, and the figures of merit known as coherence factors.

Springett, James C.↗

Cycle Time Reduction in Trapped Mercury Ion Atomic Frequency Standards

The use of the mercury ion isotope (201)Hg(+) was examined for an atomic clock. Taking advantage of the faster optical pumping time in (201)Hg(+) reduces both the state preparation and the state readout times, thereby decreasing the overall cycle time of the clock and reducing the impact of medium-term LO noise on the performance of the frequency standard. The spectral overlap between the plasma discharge lamp used for (201)Hg(+) state preparation and readout is much larger than that of the lamp used for the more conventional (199)Hg(+). There has been little study of (201)Hg(+) for clock applications (in fact, all trapped ion clock work in mercury has been with (199)Hg(+); however, recently the optical pumping time in (201)Hg(+) has been measured and found to be 0.45 second, or about three times faster than in (199)Hg(+) due largely to the better spectral overlap. This can be used to reduce the overall clock cycle time by over 2 seconds, or up to a factor of 2 improvement. The use of the (201)Hg(+) for an atomic clock is totally new. Most attempts to reduce the impact of LO noise have focused on reducing the interrogation time. In the trapped ion frequency standards built so far at JPL, the optical pumping time is already at its minimum so that no enhancement can be had by shortening it. However, by using (201)Hg(+), this is no longer the case. Furthermore, integrity monitoring, the mechanism that determines whether the clock is functioning normally, cannot happen faster than the clock cycle time. Therefore, a shorter cycle time will enable quicker detection of failure modes and recovery from them.

Burt, Eric A.↗

Improved Linear-Ion-Trap Frequency Standard

Improved design concept for linear-ion-trap (LIT) frequency-standard apparatus proposed. Apparatus contains lengthened linear ion trap, and ions processed alternately in two regions: ions prepared in upper region of trap, then transported to lower region for exposure to microwave radiation, then returned to upper region for optical interrogation. Improved design intended to increase long-term frequency stability of apparatus while reducing size, mass, and cost.

Prestage, John D.↗

Stray-field-induced quadrupole shift and absolute frequency of the 688-THz {sup 171}Yb{sup +} single-ion optical frequency standard

We report experimental investigations of a single-ion optical frequency standard based on {sup 171}Yb{sup +}. The ion is confined in a cylindrically symmetric radiofrequency Paul trap. The reference transition is the {sup 2}S{sub 1/2}(F=0)-{sup 2}D{sub 3/2}(F{sup '}=2) electric quadrupole transition at 688 THz. Using a differential measurement scheme, we determine the shift of the reference transition frequency that occurs due to the interaction of the electric quadrupole moment of the {sup 2}D{sub 3/2} state with the gradient of the electrostatic stray field in the trap. We determine an upper limit for the instability of the quadrupole shift over times between 100 s to 20 h. We also observe the variations in the shift and in the applied stray-field compensation voltages that result from loading a new ion into the trap and during a subsequent storage period of 74 days. This information is utilized to measure the absolute frequency of the reference transition with an uncertainty that is a factor of 3 smaller than that of the previous measurement. Using a fiber laser based optical frequency comb generator and the cesium fountain clock CSF1 of PTB (Physikalisch-Technische Bundesanstalt), the frequency at 300 K temperature is determined as 688 358 979 309 306.62{+-}0.73 Hz.

74 ATOMIC AND MOLECULAR PHYSICS↗

Elimination of the light shift in rubidium gas cell frequency standards using pulsed optical pumping

Changes in the intensity of the light source in an optically pumped, rubidium, gas cell frequency standard can produce corresponding frequency shifts, with possible adverse effects on the long-term frequency stability. A pulsed optical pumping apparatus was constructed with the intent of investigating the frequency stability in the absence of light shifts. Contrary to original expectations, a small residual frequency shift due to changes in light intensity was experimentally observed. Evidence is given which indicates that this is not a true light-shift effect. Preliminary measurements of the frequency stability of this apparatus, with this small residual pseudo light shift present, are presented. It is shown that this pseudo light shift can be eliminated by using a more homogeneous C-field. This is consistent with the idea that the pseudo light shift is due to inhomogeneity in the physics package (position-shift effect).

English, T. C.↗

Dual-Ion-Trap Frequency Standards With Overlapping Cycles

Proposed scheme for enhancing performances of atomic frequency-standard apparatuses calls for two or more ion traps per apparatus interrogated in alternation by radio-frequency pulses. Provides nearly constant feedback gain, thereby providing nearly constant corrections for fluctuations in frequency of local oscillator. Degradation of performance by fluctuations in local oscillators reduced.

Dick, G. John↗