Search NASA⌕ Search

SEARCH · Search NASA

Results for “FRMAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

89 records · Page 5

Summary Report for the Environmental Protection Agency MERL/FRMAC/RAP Mission Alignment Exercise held at the Savannah River Site on June 9-13 2014

From June 9th thru June 13th 2014, members of the Federal Radiological Monitoring and Assessment Center (FRMAC), the Environmental Protection Agency (EPA) and the Department of Energy Radiological Assistance Program (DOE RAP) Region-3 participated in a joint nuclear incident emergency response exercise at the Savannah River Site (SRS) near Aiken, South Carolina. The purpose of this exercise was to strengthen the interoperability relationship between the FRMAC, RAP, and the EPA Mobile Environmental Radiation Laboratory (MERL) stationed in Montgomery, Alabama. The exercise was designed to allowed members of the DOE RAP Region-3 team to collect soil, water, vegetation and air samples from SRS and submit them through an established FRMAC hotline. Once received and processed through the hotline, FRMAC delivered the samples to the EPA MERL for sample preparation and laboratory radiological analysis. Upon completion of laboratory analysis, data was reviewed and submitted back to FRMAC via an electronic data deliverable (EDD). As part of the exercise, an evaluation was conducted to identify gaps and potential improvements in each step of the processes. Additionally, noteworthy practices and potential future areas of interoperability between FRMAC and EPA were acknowledged. The exercise also provided a unique opportunity for FRMAC personnel to observe EPA sample receipt and sample preparation processes and to gain familiarity with the MERL laboratory instrumentation and radiation detection capabilities. The observations and lessons-learned from this exercise will be critical for developing a more efficient, integrated response for future interactions between the FRMAC and EPA assets.

54 ENVIRONMENTAL SCIENCES↗

Summary Report for the Environmental Protection Agency MERL/FRMAC Mission Alignment Exercise held at the Environmental Protection Agency Facility on June 24-26 2014

From June 24th thru June 26th 2014, members of the Federal Radiological Monitoring and Assessment Center (FRMAC), FRMAC Fly Away Laboratory, and the Environmental Protection Agency (EPA) participated in a joint nuclear incident emergency response/round robin exercise at the EPA facility in Las Vegas, Nevada. The purpose of this exercise was to strengthen the interoperability relationship between the FRMAC Fly Away Laboratory (FAL) and the EPA Mobile Environmental Radiation Laboratory (MERL) stationed in Las Vegas, Nevada. The exercise was designed to allow for immediate delivery of pre-staged, spiked samples to the EPA MERL and the FAL for sample preparation and radiological analysis. Upon completion of laboratory analysis, data was reviewed and submitted back to the FRMAC via an electronic data deliverable (EDD). In order to conduct a laboratory inter-comparison study, samples were then traded between the two laboratories and re-counted. As part of the exercise, an evaluation was conducted to identify gaps and potential areas for improvements for FRMAC, FAL and EPA operations. Additionally, noteworthy practices and potential future areas of interoperability opportunities between the FRMAC, FAL and EPA were acknowledged. The exercise also provided a unique opportunity for FRMAC personnel to observe EPA sample receipt and sample preparation processes and to gain familiarity with the MERL laboratory instrumentation and radiation detection capabilities. The areas for potential improvements and interoperability from this exercise will be critical for developing a more efficient, integrated response for future interactions between the FRMAC and EPA MERL assets.

54 ENVIRONMENTAL SCIENCES↗

Federal Radiological Monitoring and Assessment Center Monitoring Manual Volume 1, Operations

The Monitoring division is primarily responsible for the coordination and direction of: Aerial measurements to delineate the footprint of radioactive contaminants that have been released into the environment. Monitoring of radiation levels in the environment; Sampling to determine the extent of contaminant deposition in soil, water, air and on vegetation; Preliminary field analyses to quantify soil concentrations or depositions; and Environmental and personal dosimetry for FRMAC field personnel, during a Consequence Management Response Team (CMRT) and Federal Radiological Monitoring and Assessment Center (FRMAC) response. Monitoring and sampling techniques used during CM/FRMAC operations are specifically selected for use during radiological emergencies where large numbers of measurements and samples must be acquired, analyzed, and interpreted in the shortest amount of time possible. In addition, techniques and procedures are flexible so that they can be used during a variety of different scenarios; e.g., accidents involving releases from nuclear reactors, contamination by nuclear waste, nuclear weapon accidents, space vehicle reentries, or contamination from a radiological dispersal device. The Monitoring division also provides technicians to support specific Health and Safety Division activities including: The operation of the Hotline; FRMAC facility surveys; Assistance with Health and Safety at Check Points; and Assistance at population assembly areas which require support from the FRMAC. This volume covers deployment activities, initial FRMAC activities, development and implementation of the monitoring and assessment plan, the briefing of field teams, and the transfer of FRMAC to the EPA.

61 RADIATION PROTECTION AND DOSIMETRY↗

Software Requirements for a Consequence Management Sample Data Simulator for Training and Drills

This document describes the requirements for a software tool that will enable FRMAC to simulate large sets of sample result data that is based realistically on simulated radionuclide deposition grids from NARAC. The user of this tool would be scientists involved in exercise and drill planning or part of the simulation cell of an exercise controller team. A key requirement is that this tool must be able to be run with a reasonable amount of training and job aids by any person within the Assessment, Laboratory Analysis, or Monitoring and Sampling divisions of the FRMAC to support any level of exercise from the small IPX to the national level full scale exercise. This tool should be relatively lean and stand-alone so that the user can run it in the field with limited IT resources. This document will describe the desired architecture, design characteristics, order of operations, and algorithms that can be given to a software development team to assist them in project scoping, costing, and eventually, development.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radioisotope Thermoelectric Generator Accident Pre-Assessed Scenario

This scenario was drafted for inclusion in a revision of Federal Radiological Monitoring and Assessment Center (FRMAC) Assessment Manual, Volume 2 - Pre-Assessed Default Scenarios. The contents of this scenario were reviewed and approved by the FRMAC Assessment Working Group in March 2020. The scenario is being issued separately from the full volume ahead of the Mars 2020 launch. The full volume will be published in the future once all scenarios are complete.

61 RADIATION PROTECTION AND DOSIMETRY↗

Consequence Management Cobalt Magnet 2022 Laboratory Analysis: After Action Report

On May 16-20, 2022, federal mission partners (e.g., DOE Consequence Management, CDC, FDA, FBI, DHS) as well as integrated state, local, tribal, and territorial governments took part in Cobalt Magnet 22 (CM22), a large-scale, week-long radiological incident exercise in Austin, Texas, that linked several important national assets (National Search Program, Radiological Assistance Program, and Consequence Management [CM] personnel) into a single response effort. The exercise had nine (9) overarching Objectives and an additional 162 associated Critical Tasks for all the participating organizations. In total, 13 National Core Capabilities spanning 5 Mission Areas were represented in the final exercise. This exercise enabled a full range of capabilities to be fielded together and examine the operational connection between major assets, discover any resource shortages associated with conducting multiple mission areas simultaneously or in close succession, and identify any challenges related to leadership. This report summarizes nearly 100 successes and observations provided from players and controllers supporting the LA Division, Fly Away Laboratory (FAL) and Gamma Spectroscopist operations. The observations were categorized to align with the FRMAC programmatic functional areas to consider for future improvements: Logistics, CBRN Responder, Laboratory Analysis, Sampling and Monitoring, Health and Safety, Gamma Spectroscopist Operations, Fly Away Laboratory, and the FRMAC Interdivision Interoperability Group (FIIG).

54 ENVIRONMENTAL SCIENCES↗

Evaluation of COTS Rad Detection Apps

Mobile applications are currently under distribution to smart phones utilizing the built-in charge coupled-device (CCD) camera as a radiation detector. The CCD detector has a very low but measurable gamma interaction cross section so the mechanism is feasible, especially for higher dose rate environments. Given that in a large release of radioactive material these ‘crowd sourced’ measurements will be put forth for consideration, a testing and evaluation of the accuracy and uncertainty of the Apps is a critical endeavor. Not only is the accuracy of the reported measurement of concern to the immediate user’s safety, a quantitative uncertainty is required for a government response such as the Federal Radiological Monitoring and Assessment Center (FRMAC) to accept the values for consideration in the determination of regions exceeding protective action guidelines. Already, prompted by the Fukushima nuclear material releases, several repositories of this crowd-sourced data have been created (http://japan.failedrobot.com, http://www.stubbytour.com/nuc/index_en.asp, and http://www.rdtn.org) although the question remains as to the reliability of measurements incorporated into these repositories. In cases of conflict between the real-time published crowd-sourced data and governmental protective actions prepared literature should be on-hand documenting why the difference, if any, exists. Four applications for iOS devices were obtained along with hardware to benchmark their performance. Gamma/X-Ray Detector by Stephan Hotto, Geiger Camera by Senscare, and RadioactivityCounter App by Hotray LTD are all the applications available for distribution within the US that utilize the CCD camera sensor for detection of radiation levels. The CellRad app under development by Idaho National Laboratory for the Android platform was evaluated. In addition, iRad Geiger with the associated hardware accessory was also benchmarked. Radiation fields were generated in a Cs-137 JL Shepherd Model 89 shielded calibration range. The accuracy of the exposure rate within the box calibrator is +/- 5% of the system settings and NIST traceable. This is the same calibration unit utilized for calibration of US DOE exposure rate meters. Measurements were performed from 0.2 to 40,000 mR/hr. Included in the following sections are discussions on each of the evaluated applications and their performance in reporting radiation field measurements. Unfortunately the applications do not provide a readily identifiable quality of the measurement in order to produce error bars or even out of range conditions. In general all the CCD based applications had issues detecting consistent measurements in radiation fields less than 5 mR/hr. This is most likely attributable to the electronic noise level on the CCD’s becoming comparable to the signal level due to the ionizing radiation photons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Error Analysis of CM Data Products Sources of Uncertainty

This goal of this project is to address the current inability to assess the overall error and uncertainty of data products developed and distributed by DOE’s Consequence Management (CM) Program. This is a widely recognized shortfall, the resolution of which would provide a great deal of value and defensibility to the analysis results, data products, and the decision making process that follows this work. A global approach to this problem is necessary because multiple sources of error and uncertainty contribute to the ultimate production of CM data products. Therefore, this project will require collaboration with subject matter experts across a wide range of FRMAC skill sets in order to quantify the types of uncertainty that each area of the CM process might contain and to understand how variations in these uncertainty sources contribute to the aggregated uncertainty present in CM data products. The ultimate goal of this project is to quantify the confidence level of CM products to ensure that appropriate public and worker protections decisions are supported by defensible analysis.

97 MATHEMATICS AND COMPUTING↗

Radioactive Decay Chain Truncation Rules for Emergency Response Radiological Assessments

A set of radionuclide - decay chain truncation rules have been developed for use in the Turbo FRMAC and Specialized Hazard Assessment Response Capability (SHARC) software programs used to support radiological emergency response activities . Following the proposed rules, the software will truncate a decay chain after it encounters a progeny radionuclide with a half - life greater than 5,000 years. An analysis of the projected dose from many parent and progeny radionuclides over a 50 - year time period yielded that a radionuclide half - life cutoff of 5,000 years will exclude a negligible dose. Implementing the truncation rules will reduce the time required for assessments and minimize computer hardware requ irements without having a significant detrimental effect on dose projections and emergency response decisions. It is noted that the truncation rules may not be suited for long - term ( greater than 50 year) environmental assessments.

07 ISOTOPE AND RADIATION SOURCES↗

GADRAS Batch Inject Tool User Guide

Gamma Detector Response and Analysis Software (GADRAS) is used by the radiation detection and emergency response community to perform modeling and spectral analysis for gamma detector systems. Built into GADRAS is the ability to define a detector, geometry, background characteristics and source composition to generate synthetic spectra for drills and exercises (injects). Consequence Management is currently in development of a sample result data simulator tool in which a deposition model is probed for source conditions at moments in time and locations in space. These values are used to generate realistic sample results for use in drills and exercises. In addition to sample results, there is a need to simulate the actual spectra that would be observed in the field by downlooking HPGe instruments given a deposition activity. This way, the FRMAC Gamma Spectroscopist can practice their process of generating quantified results from spectra on realistic data as well. Recognizing the decades of work done in GADRAS to accurately generate synthetic spectra, this team decided to build a link between the new simulator and GADRAS to generate these spectra quickly and easily. The simulator tool will generate a file that specifies the name of the spectra, its location, date/time of measurement, duration of measurement, height off the ground, and the deposition activity and age for every radionuclide in the simulation. Then, a new tool within the Inject Tab of GADRAS was developed to read in this file given a detector selection and generate In-Situ spectra for each row in the file in any file format the user chooses. This way, simulation cell staff can take these files and then upload them to the appropriate data system (RAMS or RadResponder) for use during drills and exercises. An advanced feature of this tool allows for generating any spectra given an appropriate model and mapping of source to model layer in the batch inject tool. This way, spectra from field sample counts, mobile laboratories, or even fixed laboratories can be generated in bulk given an estimate of the radioactivity concentration or total radioactivity in an import file. This expands the capabilities of this tool a great deal and will make it a more useful tool for CM and others to help estimate detector response for nearly any situation. This user guide will explain the steps needed to perform a batch inject file generation.

61 RADIATION PROTECTION AND DOSIMETRY↗

Validation of the Public Radiation Exposure Calculation for the Incident at the National Institute of Standards and Technology Center for Neutron Research on February 3, 2021

The Department of Energy/National Nuclear Security Administration Consequence Management Program was contacted by the Health Physics Chief of the National Institute of Standards and Technology Center for Neutron Research (NCNR) to review public radiation exposure calculations for an event that occurred on its Gaithersburg, Maryland, campus on February 3, 2021. Subject matter experts from the Nuclear Emergency Support Team (NEST) assets, specifically the Consequence Management Home Team (CMHT) and the National Atmospheric Release Advisory Center (NARAC), were selected to provide support. CMHT used three separate modeling codes to validate the results the scientists at NCNR calculated using the HotSpot model. The analyses were performed using NARAC’s in-house Lagrangian dispersion codes known as LODI and Aeolus, as well as the Turbo FRMAC software from Sandia National Laboratories. The team used parameters provided by the NCNR scientists regarding the site, applicable observable meteorological data, and environmental survey and sampling data to estimate public exposure. Each model estimated public dose at much less than 0.5 mrem. CMHT concurs with the NCNR public radiation exposure calculations which state that members of the public at the 400-meter boundary would have received a radiological dose of less than 0.5 mrem.

61 RADIATION PROTECTION AND DOSIMETRY↗

Rapid Radiological/Nuclear Consequence Assessment Tools

The goal of this work is to design a tool for rapid assessment of the areas impacted by airborne plumes and fallout from a radiological/nuclear incident, such as an Improvised Nuclear Device (IND) detonation or Radiological Dispersal Device (RDD) release, for use by state and local technical specialists and emergency responders. The tool would produce information on the distances and areas near an incident location in which hazards may exist. This would inform consequence management decisions by state and local responders in the critical minutes following an event, as well as assist in emergency planning before an incident. The products would be intended for use before more detailed products are available from non-local assets, such as the federal Interagency Modeling and Atmospheric Assessment Center (IMAAC) and the Federal Radiological Monitoring and Assessment Center (FRMAC). The tool’s products could provide, for example, predictions of damage zones and dangerous fallout areas to help guide the emergency response, including protection of emergency responders and the public. The initial focus of this effort is on the more difficult IND decision support tools. Existing HAZMAT tools and RDD guidance, described in this report, can also be integrated into the decision support tool.

61 RADIATION PROTECTION AND DOSIMETRY↗

Federal Radiological Monitoring and Assessment Center: Health and Safety Manual

This manual is a tool to provide information to all responders and emergency planners and is suggested as a starting point for all organizations that provide personnel/assets for radiological emergency response. It defines the safety requirements for the protection of all emergency responders. The intent is to comply with appropriate regulations or provide an equal level of protection when the situation makes it necessary to deviate. In the event a situation arises which is not addressed in the manual, an appropriate management-level expert will define alternate requirements based on the specifics of the emergency situation. This manual is not intended to pertain to the general public.

61 RADIATION PROTECTION AND DOSIMETRY↗

Consequence Management Asset Overview

Presentation summarizing DOE Consequence Management assets available to support state, local, territorial, and tribal partners during a radiological emergency. This presentation will be given at various state engagements, including training and outreach for ingestion pathway exercises, national and regional CM exercises, and trainings for radiological emergency preparedness events as requested.

61 RADIATION PROTECTION AND DOSIMETRY↗