Search NASA⌕ Search

SEARCH · Search NASA

Results for “FUJIMOTO, T”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Multiwavelength Characterization of an ACT-Selected, Lensed Dusty Star-Forming Galaxy at zeta 2.64

We present C I(21) and multi-transition C-12 O observations of a dusty star-forming galaxy, ACT J2029+0120,which we spectroscopically confirm to lie at zeta = 2.64. We detect CO(3-2), CO(5-4), CO(7-6), CO(8-7), and C I(2-1) at high significance, tentatively detect HCO+(4-3), and place strong upper limits on the integrated strength of dense gas tracers (HCN(4-3) and CS(7-6)). Multi-transition CO observations and dense gas tracers can provide valuable constraints on the molecular gas content and excitation conditions in high-redshift galaxies. We therefore use this unique data set to construct a CO spectral line energy distribution (SLED) of the source, which is most consistent with that of a ULIRG Seyfert or QSO host object in the taxonomy of the Herschel Comprehensive ULIRG Emission Survey. We employ RADEX models to fit the peak of the CO SLED, inferring a temperature of T approximately 117 K and n(sub H2) approximately 10(exp5) cm(exp -3), most consistent with a ULIRGQSO object and the presence of high-density tracers. We also find that the velocity width of the C I line is potentially larger than seen in all CO transitions forth is object, and that the L'(sub Ci(2-1))/L'(sub CO(3-2))ratio is also larger than seen in other lensed and unlensed submillimeter galaxies and QSO hosts; if confirmed, this anomaly could be an effect of differential lensing of a shocked molecular outflow.

Roberts-Borsani, G. W.↗

In-Orbit Operation of the ASTRO-H SXS

We summarize all of the in-orbit operations of the soft x-ray spectrometer (SXS) onboard the ASTROH (Hitomi) satellite. The satellite was launched on February 17, 2016, and the communication with the satellite ceased on March 26, 2016. The SXS was still in the commissioning phase, in which the set-ups were progressively changed. This paper is intended to serve as a concise reference of the events in orbit in order to properly interpret the SXS data taken during its short lifetime and as a test case for planning the in-orbit operation for future microcalorimeter missions.

Tsujimoto, Masahiro↗

Temperature Structure in the Perseus Cluster Core Observed with Hitomi

The present paper investigates the temperature structure of the X-ray emitting plasma in the core of the Perseus cluster using the 1.8-20.0 keV data obtained with the Soft X-ray Spectrometer (SXS) onboard the Hitomi Observatory. A series of four observations were carried out, with a total effective exposure time of 338 ks and covering a central region _ 7′ in diameter. The SXS was operated with an energy resolution of _5 eV (full width at half maximum) at 5.9 keV. Not only fine structures of K-shell lines in He-like ions but also transitions from higher principal quantum numbers are clearly resolved from Si through Fe. This enables us to perform temperature diagnostics using the line ratios of Si, S, Ar, Ca, and Fe, and to provide the first direct measurement of the excitation temperature and ionization temperature in the Perseus cluster. The observed spectrum is roughly reproduced by a single temperature thermal plasma model in collisional ionization equilibrium, but detailed line ratio diagnostics reveal slight deviations from this approximation. In particular, the data exhibit an apparent trend of increasing ionization temperature with increasing atomic mass, as well as small differences between the ionization and excitation temperatures for Fe, the only element for which both temperatures can be measured. The best-fit two-temperature models suggest a combination of 3 and 5 keV gas, which is consistent with the idea that the observed small deviations from a single temperature approximation are due to the effects of projection of the known radial temperature gradient in the cluster core along the line of sight. Comparison with the Chandra/ACIS and the XMM-Newton/RGS results on the other hand suggests that additional lower-temperature components

Aharonian, Felix↗

Design and On-Orbit Operation of the Adiabatic Demagnetization Refrigerator on the Hitomi Soft X-Ray Spectrometer Instrument

The Soft X-ray Spectrometer instrument on the Astro-H observatory contains a 6x6 array of x-ray microcalorimeters that is cooled to 50 mK by an adiabatic demagnetization refrigerator (ADR). The ADR consists of three stages in order to provide stable detector cooling using either a 1.2 K superfluid helium bath or a 4.5 K Joule-Thomson (JT) cryocooler as its heat sink. When liquid helium is present, two of the ADR's stages are used to single-shot cool the detectors while rejecting heat to the helium. After the helium is depleted, all three stages are used to continuously cool the helium tank (to about 1.5 K) and single-shot cool the detectors (to 50 mK), using the JT cryocooler as its heat sink. The Astro-H observatory, renamed Hitomi after its successful launch in February 2016, carried approximately 36 liters of helium into orbit. On day 5, the helium had cooled sufficiently (<1.4 K) to allow operation of the ADR. This paper describes the design, operation and on-orbit performance of the ADR, and the use of the ADR's heat rejection as a tool for mass gauging the helium tank.

adiabatic demagnetization refrigerator↗

In-orbit Operation of the Soft X-Ray Spectrometer Onboard the Hitomi Satellite

We summarize all of the in-orbit operations of the soft x-ray spectrometer (SXS) onboard the ASTRO-H (Hitomi) satellite. The satellite was launched on February 17, 2016, and the communication with the satellite ceased on March 26, 2016. The SXS was still in the commissioning phase, in which the set-ups were progressively changed. This paper is intended to serve as a concise reference of the events in orbit in order to properly interpret the SXS data taken during its short lifetime and as a test case for planning the in-orbit operation for future microcalorimeter missions.

ASTRO-H↗

In-Flight Calibration of Hitomi Soft X-Ray Spectrometer. (1) Background

The X-Ray Spectrometer (XRS) instrument of Suzaku provided the first measurement of the non-X-ray background (NXB) of an X-ray calorimeter spectrometer, but the data set was limited. The Soft X-ray Spectrometer (SXS) instrument of Hitomi was able to provide a more detailed picture of X-ray calorimeter background, with more than 360 ks of data while pointed at the Earth, and a comparable amount of blank-sky data. These data are important not only for analyzing SXS science data, but also for categorizing the contributions to the NXB in X-ray calorimeters as a class. In this paper, we present the contributions to the SXS NXB, the types and effectiveness of the screening, the interaction of the screening with the broad-band redistribution, and the residual background spectrum as a function of magnetic cut-off rigidity. The orbit-averaged SXS NXB in the range 0.3-12 keV was 4 × 10(exp −2) counts s(exp −1) -sq cm. This very low background in combination with groundbreaking spectral resolution gave SXS unprecedented sensitivity to weak spectral lines.

Kilbourne, Caroline A.↗

Design, Implementation, and Performance of the Astro-H Soft X-Ray Spectrometer Aperture Assembly and Blocking Filters

The calorimeter array of the JAXA Astro-H (renamed Hitomi) soft x-ray spectrometer (SXS) was designed to provide unprecedented spectral resolution of spatially extended cosmic x-ray sources and of all cosmic x-ray sources in the Fe-K band around 6 keV. The properties that made the SXS array a powerful x-ray spectrometer also made it sensitive to photons from the entire electromagnetic band as well as particles. If characterized as a bolometer, it would have had a noise equivalent power of <4 × 10(exp −18) W/((Hz)(exp 0.5)). Thus, it was imperative to shield the detector from thermal radiation from the instrument and optical and UV photons from the sky. In addition, it was necessary to shield the coldest stages of the instrument from the thermal radiation emanating from the warmer stages. These needs were addressed by a series of five thin-film radiation-blocking filters, anchored to the nested temperature stages, that blocked long-wavelength radiation while minimizing x-ray attenuation. The aperture assembly was a system of barriers, baffles, filter carriers, and filter mounts that supported the filters and inhibited their potential contamination. The three outer filters also had been equipped with thermometers and heaters for decontamination. We present the requirements, design, implementation, and performance of the SXS aperture assembly and blocking filters.

Kilbourne, Caroline A.↗

Porous Plug Phase Separator and Superfluid Film Flow Suppression System for the Soft X-Ray Spectrometer Onboard Hitomi

When using superfluid helium in low gravity environments, porous plug phase separators are commonly used to vent boiloff gas while confining the bulk liquid to the tank. Invariably, there is a flow of superfluid film from the perimeter of the porous plug down the vent line. For the Soft X-ray Spectrometer onboard ASTRO-H (Hitomi), its approximately 30-liter helium supply has a lifetime requirement of more than 3 years. A nominal vent rate is estimated as ~ 30 ug/s, equivalent to ~ 0.7 mW heat load. It is therefore critical to suppress any film flow whose evaporation would not provide direct cooling of the remaining liquid helium. That is, the porous plug vent system must be designed to both minimize film flow and to ensure maximum extraction of latent heat from the film. The design goal for Hitomi is to reduce the film flow losses to <2 ug/s, corresponding to a loss of cooling capacity of <40 uW. The design adopts the same general design as implemented for Astro-E and E2, using a vent system composed of a porous plug, combined with an orifice, a heat exchanger, and knife-edge devices. In this paper, design, on-ground testing results and in-orbit performance are described.

Porous↗

Investigating Mercury's Environment with the Two-Spacecraft BepiColombo Mission

The ESA-JAXA BepiColombo mission will provide simultaneous measurements from two spacecraft, offering an unprecedented opportunity to investigate magnetospheric and exospheric dynamics at Mercury as well as their interactions with the solar wind, radiation, and interplanetary dust. Many scientific instruments onboard the two spacecraft will be completely, or partially devoted to study the near-space environment of Mercury as well as the complex processes that govern it. Many issues remain unsolved even after the MES-SENGER mission that ended in 2015. The specific orbits of the two spacecraft, MPO and Mio, and the comprehensive scientific payload allow a wider range of scientific questions to be addressed than those that could be achieved by the individual instruments acting alone, or by previous missions. These joint observations are of key importance because many phenomena in Mercury’s environment are highly temporally and spatially variable. Examples of possible coordinated observations are described in this article, analysing the required geometrical conditions, pointing, resolutions and operation timing of different BepiColombo instruments sensors.

Mercury's environment↗

PNEUMATIC SAMPLER (P-SAMPLER) FOR THE MARTIAN MOONS EXPLORATION (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos . The spacecraft will perform close-up remote sensing and observations of both moons, and collect a sample from Phobos for Earth sample return. MMX has set the two mission goals: (1) determining the origin of the Martian moons and (2) observing processes in the circumplanetary environment of Mars, based on remote sensing, in-situ observations, and laboratory analyses of returned Phobos regolith.

D. Van Dyne↗

Pneumatic Sampler (P-SAMPLER) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (). The spacecraft will perform close-up remote sensing and observations of both moons, and collect a sample from Phobos for Earth sample return.

D Van Dyne↗

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

The Martian Moons eXploration (MMX) mission, led by the Japanese Aerospace Exploration Agency (JAXA), will focus on the exploration of the two Martian moons – Phobos and Deimos (Figure 1). The spacecraft will perform close-up remote sensing and observations of both moons and collect a sample from Phobos for Earth sample return. MMX has set the two mission goals: (1) determining the origin of the Martian moons and (2) observing processes in the circumplanetary environment of Mars, based on remote sensing, in-situ observations, and laboratory analyses of returned samples of Phobos regolith [1-2]. To fulfill the mission goals, MMX employs a double sampling approach: Coring and Pneumatic Samplers (Figure 2).The Coring Sampler (C-Sampler), a core soil tube deployed by a robotic arm, providing access to the building blocks of Phobos beneath the surface (>2 cm), and also collect a mixture of near surface material. The P-Sampler, on the other hand, would selectively sample the surface veneer and provides reference of surface component with the C-Sampler. The double sampling system not only enhances the scientific merits of MMX but also reduces risks associated with the sampling of Phobos. Without enough knowledge of the physical and chemical properties, and the geotechnical conditions of the surface of Phobos (e.g., compositions, temperature gradient/variation, porosity, grain size distribution), having two sampling systems that utilize entirely different sampling approaches is prudent.

Dylan Van Dyne↗

Pneumatic Sampler (P-Sampler) for the Martian Moons Exploration (MMX)

A Pneumatic Sampler (P-SMP)is being provided by Honeybee Robotics with support from NASA Planetary Missions Program Office (PMPO)for JAXA’s Martian Moons eXploration (MMX) mission. The goal of this mission is to closely survey the Martian moons Deimos and Phobos, and then to collect regolith from Phobos and return it to Earth. The P-SMP will be mounted to a leg of the lander and will be responsible for collecting surface regolith alongside the JAXA provide Core Sampler (C-SMP). The Sampling Funnel of the P-SMP utilizes two sets of sampling nozzles: one set of nozzles pointed directly at the surface to kick-up and loft material into the sampling head, and a second set of nozzles to direct the oncoming material into the sample return canister further up the lander leg. A robotic arm mounted underneath the lander will then remove the sample canister and place it inside the sample return capsule for Earth return. Several iterations of the P-Sampler have been designed and tested inside a vacuum chamber with Phobos regolith simulant. In all tests, the P-Sampler successfully acquired the sample, even in an extreme scenario where the sampling head was mounted 10 cm above a surface covered with gravel.

Dylan Van Dyne↗

Finding and Fixing a Small Low Temperature Leak - A Case Study on XRISM/Resolve

The Resolve instrument on the X-Ray Imaging and Spectroscopy Mission (XRISM) uses an Adiabatic Demagnetization Refrigerator (ADR) to cool extremely sensitive x-ray microcalorimeters to 50 mK. A 40-liter superfluid helium dewar and a 4.5 K Joule Thomson (JT)/Stirling cryocooler serve as heat sinks for the ADR and staged cooling for the dewar. The superfluid helium lifetime is required to last at least 3 years on orbit with margin. The superfluid helium dewar developed a small leak (~5e-7 Pa m^3/s) at low temperature which compromised the dewar vacuum in two days of ground testing. It turns out that this leak disappears completely at room temperature (<5e-13 Pa m^3/s). This presentation describes the lengthy process of characterizing, isolating, and ultimately, repairing this leak.

Michael DiPirro↗

Investigating Mercury’s environment with the Two-Spacecraft BepiColombo Mission

The ESA-JAXA BepiColombo mission will provide simultaneous measurements from two spacecraft, offering an unprecedented opportunity to investigate magnetosphericand exospheric dynamics at Mercury as well as their interactions with the solar wind, radiation, and interplanetary dust. Many scientific instruments onboard the two spacecraft will be completely, or partially devoted to study the near-space environment of Mercury as well as the complex processes that govern it. Many issues remain unsolved even after the MESSENGER mission that ended in 2015. The specific orbits of the two spacecraft, MPO and Mio, and the comprehensive scientific payload allow a wider range of scientific questions to be addressed than those that could be achieved by the individual instruments acting alone, or by previous missions. These joint observations are of key importance because many phenomena in Mercury’s environment are highly temporally and spatially variable. Examples of possible coordinated observations are described in this article, analysing the required geometrical conditions, pointing, resolutions and operation timing of different BepiColombo instruments sensors.

A Milillo↗

Major Scientific Challenges and Opportunities in Understanding Magnetic Reconnection and Related Explosive Phenomena in Heliophysics and Beyond

Magnetic reconnection underlies many explosive phenomena in the heliosphere and in laboratory plasmas. New research capabilities in theory/simulations, observations, and laboratory experiments provide the opportunity to solve the grand scientific challenges summarized in this white paper. Success will require enhanced and sustained investments from relevant funding agencies, increased interagency/international partnerships, and close collaborations among the heliophysics, astrophysics, and laboratory plasma communities. These investments will deliver transformative progress in understanding magnetic reconnection and related explosive phenomena including space weather events.

H. Ji↗

On-Orbit Performance of the Adiabatic Demagnetization Refrigerator on XRISM

The X-ray Imaging and Spectroscopy Mission (XRISM) observatory was launched on Sep 7, 2023 from Tanegashima Space Center in Japan. Resolve, one its two instruments, performs high-resolution spectroscopy in the soft x-ray band (0.2-13 keV) using a 6x6 microcalorimeter array. The array cooled to 50 mK by a 3-stage ADR, which is linked to both a liquid helium dewar (at <1.2 K) and a Joule-Thomson (JT) cryocooler operating at <4.5 K. While liquid helium is present, two of the ADR stages provide detector cooling at 50 mK and auxiliary cooling to 0.5 K to intercept some parasitic heat loads, while rejecting waste heat to the helium. Once the helium is exhausted, Resolve enters a cryogen-free mode in which all three ADR stages are operated to provide detector cooling at 50 mK and to continuously cool the helium tank to 1.4 K. In this mode, waste heat is rejected to the JT cryocooler. Cryogen-free operation can be sustained as long as the JT and other cryocoolers remain fully operational. At launch, the helium tank contained approximately 35.6 liters of liquid. Within a few days, the helium cooled below 1.15 K, with an estimated 35.0 liters remaining. With an expected time average heat load of 0.68 mW, the helium lifetime was projected to exceed 4 years, but measurements of He volume on orbit suggest a significantly longer lifetime. Details of the ADR’s design and performance are presented.

x-ray astromony↗

Measuring the Liquid Helium Volume on XRISM and Predicting the Liquid Lifetime

The XRISM/Resolve instrument uses an adiabatic demagnetization refrigerator (ADR) to cool microcalorimeters to 50 mK. The cryogenic system to support the ADR consists of a liquid helium dewar and 5 cryocoolers that provide a semi-redundant system. Operation of the ADR requires either a liquid helium heat sink at 1.2 K or 4.5 K heat sink provided by a multi-stage cryocooler system. The 5 cryocoolers also provide thermal protection to the liquid helium dewar. To calculate the expected lifetime of the liquid helium system, the liquid helium volume was measured before launch and several techniques were employed to determine on-orbit boil off rate.

Michael Dipirro↗