Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fabry–Perot interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Matched tandem etalon camera - MATEC - and its application to auroral observations

The matched tandem etalon camera employs a Fabry-Perot interferometer (FP) in the photographic mode for the spatial resolution over all angles up to 7 deg from normal. An interference filter and an appropriate field lens isolate a single order of 0.1 A resolution, which is recorded simultaneously at all angles in the field of view by array detection. Thus the resolution and luminosity of the MATEC camera are those of the FP. The MATEC pilot model has a ratio of free spectral range to linewidth of 400 and utilizes intensified photographic detection. In a system applied to auroral measurements the MATEC views a semiconical sky mirror to provide a simulatenous dimension of spatial resolution in the N-S meridian combined with the dimension of spectral resolution. Stellar features and cloud and ground reflections are more easily identified than by any scanning photometer.

Young, E. R.↗

Calibration of the Urbana lidar system

A method for calibrating data obtained by the Urban sodium lidar system is presented. First, an expression relating the number of photocounts originating from a specific altitude range to the soodium concentration is developed. This relation is then simplified by normalizing the sodium photocounts with photocounts originating from the Rayleigh region of the atmosphere. To evaluate the calibration expression, the laser linewidth must be known. Therefore, a method for measuring the laser linewidth using a Fabry-Perot interferometer is given. The laser linewidth was found to be 6 + or - 2.5 pm. Problems due to photomultiplier tube overloading are discussed. Finally, calibrated data is presented. The sodium column abundance exhibits something close to a sinusoidal variation throughout the year with the winter months showing an enhancement of a factor of 5 to 7 over the summer months.

Cerny, T.↗

Optical observations of thermospheric dynamics at Arecibo

A description is given of wind and temperature data obtained with a 15-cm Fabry-Perot interferometer. The observations were made between February and August 1980 and confirm the details of the conceptual model of Herrero and Meriwether (1980). Attention is given to the method used to analyze the neutral wind field, the zonal winds, the meridional wind, the horizontal wind gradient, the vertical wind velocity, the full wind field, and the neutral temperature. The most regular feature of the neutral wind at Arecibo is the zonal component, which has a peak velocity in the eastward direction near sunset, and decreases in velocity as the night progresses. Both the wind and temperature measurements reported provide ample confirmation of the importance of the equatorial midnight pressure bulge in modifying the dynamic behavior of the nighttime thermosphere at Arecibo.

Burnside, R. G.↗

Nonthermal line profiles from O/1S/ in the thermospheric nightglow

Generalized composite nonthermal line profiles are calculated for the thermospheric nighttime emission from O(1S) metastable atoms based on an extension to the simple relaxation model of Hays and Walker (1966). It is shown that the Dynamics Explorer Fabry-Perot interferometer will enable accurate values to be obtained for the branching ratio of the O(1S) production reaction and for the excitation exchange collision frequency.

Killeen, T. L.↗

High-resolution optical measurements of atmospheric winds from space. I - Lower atmosphere molecular absorption

A high-resolution spectroscopic technique, analogous to that used in the thermosphere to measure the vector wind fields in the upper troposphere and stratosphere, is described which uses narrow features in the spectrum of light scattered from the earth's lower atmosphere to provide Doppler information on atmospheric scattering and absorption. It is demonstrated that vector winds can be measured from a satellite throughout the lower atmosphere, using a multiple-etalon Fabry-Perot interferometer of modest aperture. It is found that molecular oxygen and water vapor absorption lines in the spectrum of sunlight scattered by the atmosphere are Doppler-shifted by the line of sight wind, so that they may be used to monitor the global wind systems in the upper troposphere and stratosphere.

Hays, P. B.↗

Fiber-optic bolometer with low detection limit fabricated using thermal release tape and precise laser heating

Fiber-optic bolometers (FOBs) based on a fiber-tipped silicon Fabry–Perot (FP) interferometric temperature sensor and a gold disk absorber have been shown to be an attractive alternative to conventional resistive bolometers for plasma radiation measurement in fusion devices. Either a high-finesse FP or a low-finesse FP can be used, each with trade-offs between noise performance and fabrication complexity. In this paper, we present an FOB design that overcomes these limitations by combining a low-finesse long silicon FP cavity with a large gold disk absorber to achieve enhanced sensitivity and noise performance without increasing the fabrication complexity and the time constant. We also demonstrated a fabrication method for the sensor head facilitated by thermal release tape and precise laser heating. Our FOB demonstrates a temperature resolution of 0.08 mK, a cooling time constant of 230 ms, and a noise equivalent power density of 0.015 W m −2 . This represents an eightfold improvement over previous high-finesse FOBs and 26-fold improvement over previous low-finesse FOBs with similar demodulation bandwidths and similar cooling time constants.

Fabry–Perot interferometer↗

A pressure scanning Fabry-Perot magnetometer.

Description of an oscillating magnetic analyzer (KDP crystal plus Glan-Thompson prism) coupled to an echelle-interferometer spectrograph, and of single-slit magnetometer which by pressure variations can be made to scan the entire profiles of the circularly and linearly polarized Zeeman components. Freon gas is used as the scanner gas with wavelength displacements of 0.02 A per 0.1 in. Hg pressure change at the NaD lines. The available scan range is 15 A in the visual spectral region.

Fay, T. D.↗

Infrared Fabry-Perot and heterodyne spectrometers

The status of infrared instrumentation for astronomical investigations at U.C. Berkeley is described with emphasis on the techniques of high spectral and spatial resolution. Present instrumentation includes three Fabry-Perot spectrometers for the 10, 20, and 100 micron wavelength regions, a submillimeter receiver using an optically pumped laser, a 10 micron heterodyne spectrometer for studies of planetary atmospheres, and a 2-element 10 micron stellar interferometer for measuring the angular diameters of infrared stars.

Betz, A.↗

Optical design of the ATMOS Fourier transform spectrometer

The optical system design of the ATMOS Fourier transform spectrometer to be operated from Spacelab for the measurement of stratospheric trace molecules is described. The design contains features which can achieve the required fringe contrast of 80% and spectral resolution of 0.02/cm over a spectral range of 2-16 microns. In particular, the design is based on the following features which alleviate the usual requirements for alignment precision: (1) 'cat's eye' mirror configuration in the two arms of the interferometer for retroreflection stability, (2) tilt-compensated system of beamsplitter, compensator, and fold mirrors for wavefront directional stability, (3) paraboloidal 'cat's eye' primary mirror for wavefront stability against shear, (4) rotatable compensator for matching chromatic dispersion, and (5) wedged refractive components to avoid channel spectra due to the Fabry-Perot effect.

Abel, I. R.↗