Search NASA⌕ Search

SEARCH · Search NASA

Results for “Fault characterization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

Field characterization of elastic properties across a fault zone reactivated by fluid injection

In this paper, we studied the elastic properties of a fault zone intersecting the Opalinus Clay formation at 300 m depth in the Mont Terri Underground Research Laboratory (Switzerland). Four controlled water injection experiments were performed in borehole straddle intervals set at successive locations across the fault zone. A three-component displacement sensor, which allowed capturing the borehole wall movements during injection, was used to estimate the elastic properties of representative locations across the fault zone, from the host rock to the damage zone to the fault core. Young's moduli were estimated by both an analytical approach and numerical finite difference modeling. Results show a decrease in Young's modulus from the host rock to the damage zone by a factor of 5 and from the damage zone to the fault core by a factor of 2. In the host rock, our results are in reasonable agreement with laboratory data showing a strong elastic anisotropy characterized by the direction of the plane of isotropy parallel to the laminar structure of the shale formation. In the fault zone, strong rotations of the direction of anisotropy can be observed. Finally, the plane of isotropy can be oriented either parallel to bedding (when few discontinuities are present), parallel to the direction of the main fracture family intersecting the zone, and possibly oriented parallel or perpendicular to the fractures critically oriented for shear reactivation (when repeated past rupture along this plane has created a zone).

58 GEOSCIENCES↗

Stirling Convertor Controller Development at NASA Glenn Research Center

Over the past decade, NASA Glenn Research Center (GRC) has been supporting the development of Radioisotope Power Systems (RPS). NASA desires higher conversion efficiency RPS options that are reliable and robust with long life design. Dynamic conversion, such as Stirling and Brayton, offer the potential for higher conversion efficiencies but have yet to be demonstrated in a flight application. The RPS program sent out a solicitation to investigate options for dynamic conversion technologies. As a result of this solicitation, four dynamic power convertor (DPC) technologies were selected for design and fabrication of a prototype dynamic convertor. One lesson learned from the Advanced Stirling Radioisotope Generator (ASRG) project is that controller development should start early in the development of a dynamic convertor. As a result of this, NASA GRC has been utilizing hardware from past Stirling convertor projects including that of the ASRG to support controller development for the DPC's. NASA GRC has developed a strong knowledge base on both analog and digital Stirling dynamic power convertor controllers and will continue to expand and apply that knowledge to the four DPC's. Over the past 15 years, controllers were developed in-house at GRC, at Lockheed Martin Coherent Technologies (LMCT) and by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL). Various generations of the controllers, have been developed as lessons were learned through various component and system level tests. Some of the tests performed were fault tolerance, qualification vibration level, electromagnetic interference, Radioisotope Power System Systems Integration (RSIL) tests, and extended operation. The fault tolerance test characterized the controller's ability to handle various fault conditions, including high or low bus power consumptions, total open load or short circuit, and replacing a failed controller card while the backup maintains control of the ASC. The vibration test confirms the controller's ability to control an ASC during launch. The EMI test characterized the AC and DC magnetic and electric fields emitted by the single ASC and if the controller has an impact on the radiated EMI. RSIL testing provided insight into the electrical interactions between the representative RPS, its associated control schemes, and realistic electric system loads. The extended operation test allows data to be collected over a period of thousands of hours to obtain long term performance data of the system. This paper describes the history of controller development at NASA GRC, tests performed on these controllers, and lessons learned.

Dugala, Gina M.↗

Stirling Convertor Controller Development at NASA Glenn Research Center

For nearly two decades, NASA Glenn Research Center (GRC) has been supporting the development of Radioisotope Power Systems (RPS). NASA desires higher conversion efficiency RPS options that are reliable and robust with long life design. Dynamic conversion, such as Stirling and Brayton, offer the potential for higher conversion efficiencies than current RPS but have yet to be demonstrated in a flight application. The RPS program sent out a solicitation to investigate options for dynamic conversion technologies. As a result of this solicitation, four dynamic power convertor (DPC) technologies were selected for design and three are proceeding to the fabrication phase of prototype dynamic convertors. One lesson learned from the Advanced Stirling Radioisotope Generator (ASRG) project is that controller development should be coordinated with the development of a dynamic convertor. As a result of this, NASA GRC has been utilizing hardware from past Stirling convertor projects including that of the ASRG to support controller development for the DPC's. NASA GRC has developed a strong knowledge base on both analog and digital Stirling dynamic power convertor controllers and will continue to expand and apply that knowledge to the DPC's. Over the past 15 years, controllers were developed at GRC, at Lockheed Martin (LM) and by the Johns Hopkins University/Applied Physics Laboratory (JHU/APL). Various generations of the controllers have been developed as lessons were learned through various component and system level tests. Some of the tests performed were fault tolerance, flight acceptance vibration, electromagnetic interference (EMI), spacecraft integration, and extended operation. The fault tolerance test characterized the controller's ability to handle various fault conditions, including high or low bus power consumptions, total open load or short circuit, and replacing a failed controller card while the backup maintains control of the Stirling convertor. The vibration test confirms the controller's ability to control an ASC during launch. The EMI test characterized the AC and DC magnetic and electric fields emitted by the single ASC and if the controller has an impact on the radiated EMI. Spacecraft integration testing in the Radioisotope Power Systems System Integration Laboratory (RSIL) provided insight into the electrical interactions between the representative RPS, its associated control schemes, and realistic electric system loads. The extended operation test allows data to be collected over a period of thousands of hours to obtain long term performance data of the system. This paper describes the history of controller development at NASA GRC, tests performed on these controllers, and lessons learned.

Dugala, Gina M.↗

Stirling Convertor Controller Development at NASA Glenn Research Center

For nearly two decades, NASA Glenn Research Center has been supporting the development of radioisotope power systems (RPS). NASA desires higher conversion efficiency RPS options that are reliable and robust with long-life design. Dynamic conversion, such as Stirling and Brayton, offer the potential for higher conversion efficiencies than current RPS but have yet to be demonstrated in a flight application. The RPS program sent out a solicitation to investigate options for dynamic conversion technologies. As a result of this solicitation, four dynamic power convertor (DPC) technologies were selected for design and three are proceeding to the fabrication phase of prototype dynamic convertors. One lesson learned from the Advanced Stirling Radioisotope Generator (ASRG) project is that controller development should be coordinated with the development of a dynamic convertor. As a result of this, Glenn has been utilizing hardware from past Stirling convertor projects, including that of the ASRG, to support controller development for the DPCs. Glenn has developed a strong knowledge base on both analog and digital Stirling DPC controllers and will continue to expand and apply that knowledge to the DPCs. Over the past 15 years, controllers were developed at Glenn, at Lockheed Martin (LM), and by the Johns Hopkins University Applied Physics Laboratory (APL). Various generations of the controllers have been developed as lessons were learned through various component- and system-level tests. Some of the tests performed were fault tolerance, flight acceptance vibration, electromagnetic interference (EMI), spacecraft integration, and extended operation. The fault tolerance test characterized the controller’s ability to handle various fault conditions, including high or low bus power consumption, total open load or short circuit, and replacing a failed controller card while the backup maintains control of the Stirling convertor. The vibration test confirms the controller’s ability to control an Advanced Stirling Convertor (ASC) during launch. The EMI test characterized the alternating-current (AC) and direct-current (DC) magnetic and electric fields emitted by the single ASC and if the controller has an impact on the radiated EMI. Spacecraft integration testing in the Radioisotope Power Systems (RPS), System Integration Laboratory (RSIL) provided insight into the electrical interactions between the representative RPS, its associated control schemes, and realistic electric system loads. The extended operation test allows data to be collected over a period of thousands of hours to obtain long-term performance data of the system. This paper describes the history of controller development at Glenn, tests performed on these controllers, and lessons learned.

Dugala, Gina M.↗

Fault Characteristics of Distributed Solar Generation

Inverter-based distributed energy resources (DERs) are characterized with low fault current and negligible amount of negative and zero sequence currents. Understanding DER's fault characteristics is important for fault analysis and protective relay setting. Despite the abundant work on DER modeling, few research studies have been done to analyze DER's fault behaviors during actual fault events. Our work explores recorded fault events collected by Dominion Energy. Fault magnitude, angle, and sequence components are analyzed to show that actual DER fault response may differ from previous understandings.

14 SOLAR ENERGY↗

On the Interplay Between Distributed Bulk Plasticity and Local Fault Slip in Evolving Fault Zone Complexity

Abstract We numerically investigate the role of plastic strain accumulation on the mechanical response of a planar strike‐slip fault. Our models show that fault‐zone strength significantly impacts the ensuing sequence of earthquakes. Weaker fault zones accumulating more plastic strain promote more complexity in the seismicity pattern through aperiodic earthquake occurrences and intermittent episodes of rupture and arrest. However, if the fault zone strength is high enough, the overall earthquake sequence is characterized by periodic fault‐spanning events. We find that both the fault normal stress and the fault geometric profile evolve throughout the earthquake sequence, suggesting a self‐roughening mechanism. Despite the significant impact of plasticity on the fault response, the width of the plastically deforming region in the fault zone is small compared to the fault length. Our results suggest a rich behavior in dynamically evolving fault zones and support the need for further high‐resolution studies of the highly non‐linear near‐fault region.

Geology↗

Earthquake source mechanisms and transform fault tectonics in the Gulf of California

The source parameters of 19 large earthquakes in the Gulf of California were determined from inversions of long-period P and SH waveforms. The goal was to understand the recent slip history of this dominantly transform boundary between the Pacific and North American plates as well as the effect on earthquake characteristics of the transition from young oceanic to continental lithosphere. For the better recorded transform events, the fault strike is resolved to + or - 4 deg at 90 percent confidence. The slip vectors thus provide important constraints on the direction of relative plate motion. Most centroid depths are poorly resolved because of tradeoffs between depth and source time function. On the basis of waveform modeling, historical seismicity, and other factors, it is appropriate to divide the Gulf into three distinct zones. The difference in seismic character among the three zones is likely the result of differing levels of maturity of the processes of rifting, generation of oceanic crust, and formation of stable oceanic transform faults. The mechanism of an earthquake on the Tres Marias Escarpment is characterized by thrust faulting and likely indicates the direction of relative motion between the Rivera and North American plates. This mechanism requires revision in plate velocity models which predict strike slip motion at this location.

Goff, John A.↗

Three-dimensional seismic characterization and imaging of the Soda Lake geothermal field

Accurate characterization of subsurface geophysical properties and detection of the fault system are essential for geothermal energy exploration and production. The Soda Lake geothermal field is in western Nevada with a complex fault system. Previous seismic characterization only produced a low-resolution, smooth velocity model along with a simple, conceptual fault model. Using optimized correlation-based full-waveform inversion, wavefield-separation-based reverse-time migration, and automatic fault detection techniques, we present 3D seismic characterization for the Soda Lake geothermal field using 3D surface seismic data acquired with Vibroseis sources. Here, we obtain 3D high-resolution velocity, density, and acoustic impedance models, 3D seismic images with different grid spacings, and a high-resolution fault system. Consistency check between the constructed faults and currently active injection and production geothermal wells verifies that our seismic inversion and imaging results and detected faults are reliable. These results can provide valuable information for optimizing well placement and geothermal energy production at the Soda Lake geothermal field.

15 GEOTHERMAL ENERGY↗

Characterizing natural fractures and sub-seismic faults for well completion of Marcellus shale in the MSEEL Consortium project, West Virginia, USA

The Middle Devonian Marcellus shale play has emerged as a major world-class hydrocarbon accumulation and represents one of the largest and most prolific shale plays in the world. According to many outcrop studies in the region, natural fractures are well developed in the Marcellus Shale. However, evaluating fractures in the subsurface is often a significant challenge due to a lack of sufficient data. Therefore, in the Marcellus Shale Energy and Environment Laboratory (MSEEL) consortium project, significant efforts have been made to acquire high-quality image logs in the Marcellus laterals. The project provided tremendous opportunities to characterize the natural fractures and sub-seismic faults and to evaluate their impact on well stimulation. In this study, about 70,000 ft of acquired high-resolution logging while drilling (LWD) acoustic images from five long laterals located in Monongalia County, West Virginia, were processed and interpreted. In addition, the study used high-quality micro-resistivity images from a pilot well, allowing the evaluation of natural fractures in the entire Marcellus vertical sequence. Based on the available acoustic images, the natural fractures were classified into three basic categories: high-amplitude fractures, low-amplitude fractures, and faults. Further, larger open fractures can also be determined when a low-amplitude fracture is evident on caliper images. The fractures in the Marcellus usually have a medium to high angle dip; however, multiple fracture sets in terms of strike orientation were clearly observed in all the laterals. The fracture set with a strike at NE-SW (or 60-240 deg) seems to be the predominant one in all the wells. A few other sets, including those with N-S, NWW-SEE, and E-W strikes, were also observed. Several sub-seismic faults, with mostly a low dip angle and a NE-SW strike, have also been seen in two of the laterals. The fracture density is variable across all the laterals, ranging from very low (or none) to very high (up to 5 fractures per ft). The average fracture density for all the laterals is about 1 fracture per 10 ft. In the vertical sequence, the natural fracture development showed a clear preference for shale or shaly facies over carbonate-rich or thin limestone layers. The interpreted fracture and fault data were used as input data for the stimulation design with the purpose of better understanding the fractures’ impact on well stimulation. Production data from the laterals were also used to evaluate the natural fractures’ influence on well performance. The quality image database and the consistent interpretation results for the entire project enabled a systematic approach to characterizing fractures and, more importantly, to evaluating the impact of fractures on well stimulation and production.

03 NATURAL GAS↗

Seismicity and recent faulting in eastern California and western and central Nevada: A preliminary report

The author has identified the following significant results. ERTS-1 imagery covering the eastern California-Nevada seismic belt were utilized to study the fault pattern in relation to the distribution of earthquake epicenters and Quaternary volcanic rocks. Many suspected faults not previously mapped were identified. These include several suspected shear zones in Nevada, faults showing evidence of recent breakage, and major lineaments. Highly seismic areas are generally characterized by Holocene faulting and Quaternary volcanic activity. However, several major fault segments showing evidence of recent breakage are associated with little or no seismicity. The tectonic pattern strongly suggests that the eastern California-Nevada seismic belt coincides with a major crustal rift associated with zones of lateral shear. New data on potentially active fault zones have direct practical applications in national and local earthquake hazard reduction programs. Positive contacts have been made with Kern and Ventura Counties to make results of this investigation available for application to their earthquake hazards definition projects.

Abdel-Gawad, M.↗

Machine-checked proofs of the design and implementation of a fault-tolerant circuit

A formally verified implementation of the 'oral messages' algorithm of Pease, Shostak, and Lamport is described. An abstract implementation of the algorithm is verified to achieve interactive consistency in the presence of faults. This abstract characterization is then mapped down to a hardware level implementation which inherits the fault-tolerant characteristics of the abstract version. All steps in the proof were checked with the Boyer-Moore theorem prover. A significant results is the demonstration of a fault-tolerant device that is formally specified and whose implementation is proved correct with respect to this specification. A significant simplifying assumption is that the redundant processors behave synchronously. A mechanically checked proof that the oral messages algorithm is 'optimal' in the sense that no algorithm which achieves agreement via similar message passing can tolerate a larger proportion of faulty processor is also described.

Bevier, William R.↗

Strain localization in dry sheared granular materials: A compactivity-based approach

Shear banding is widely observed in natural fault zones as well as in laboratory experiments on granular materials. Understanding the dynamics of strain localization under different loading conditions is essential for quantifying strength evolution of fault gouge, energy partitioning during earthquakes and characterizing rheological transitions and fault zone structure changes. To that end, we develop a physics-based continuum model for strain localization in sheared granular materials. The grain-scale dynamics is described by the Shear Transformation Zone (STZ) theory, a non-equilibrium statistical thermodynamic framework for viscoplastic deformation in amorphous materials. Using a finite strain computational framework, we investigate the initiation and growth of complex shear bands under a variety of loading conditions and identify implication for strength evolution and ductile to brittle transition. Our numerical results show similar localization patterns to field and lab observations and suggest that shear zones show more ductile response at higher confining pressures, lower dilatancy and loose initial conditions. Lower pressures, higher dilatancy and dense initial conditions favor a brittle response and larger strength drops. These findings shed light on a range of mechanisms for strength evolution in dry sheared granular materials and provide a critical input to physicsbased multiscale models of fault zone instabilities.

36 MATERIALS SCIENCE↗

Dynamic Rupture Simulations of Caldera Collapse Earthquakes: Effects of Wave Radiation, Magma Viscosity, and Evidence of Complex Nucleation at Kilauea 2018

All instrumented basaltic caldera collapses have generated M w > 5 very long period earthquakes. However, previous studies of source dynamics have been limited to lumped models treating the caldera block as rigid, leaving open questions related to how ruptures initiate and propagate around the ring fault, and the seismic expressions of those dynamics. Here, we present the first 3D numerical model capturing the nucleation and propagation of ring fault rupture, the mechanical coupling to the underlying viscoelastic magma, and the associated seismic wavefield. We demonstrate that seismic radiation, neglected in previous models, acts as a damping mechanism reducing coseismic slip by up to half, with effects most pronounced for large magma chamber volume/ring fault radius or highly compliant crust/compressible magma. Viscosity of basaltic magma has negligible effect on collapse dynamics. In contrast, viscosity of silicic magma significantly reduces ring fault slip. We use the model to simulate the 2018 Kilauea caldera collapse. Three stages of collapse, characterized by ring fault rupture initiation and propagation, deceleration of the downward-moving caldera block and magma column, and post-collapse resonant oscillations, in addition to chamber pressurization, are identified in simulated and observed (unfiltered) near-field seismograms. A detailed comparison of simulated and observed displacement waveforms corresponding to collapse earthquakes with hypocenters at various azimuths of the ring fault reveals a complex nucleation phase for earthquakes initiated on the northwest. Our numerical simulation framework will enhance future efforts to reconcile seismic and geodetic observations of caldera collapse with conceptual models of ring fault and magma chamber dynamics.

58 GEOSCIENCES↗

Active Vibration Reduction of the Advanced Stirling Convertor

Stirling Radioisotope Power Systems (RPS) are being developed as an option to provide power on future space science missions where robotic spacecraft will orbit, flyby, land or rove. A Stirling Radioisotope Generator (SRG) could offer space missions a more efficient power system that uses one fourth of the nuclear fuel and decreases the thermal footprint compared to the current state of the art. The Stirling Cycle Technology Development (SCTD) Project is funded by the RPS Program to developing Stirling-based subsystems, including convertors and controller maturation efforts that have resulted in high fidelity hardware like the Advanced Stirling Radioisotope Generator (ASRG), Advanced Stirling Convertor (ASC), and ASC Controller Unit (ACU). The SCTD Project also performs research to develop less mature technologies with a wide variety of objectives, including increasing temperature capability to enable new environments, improving system reliability or fault tolerance, reducing mass or size, and developing advanced concepts that are mission enabling. Active vibration reduction systems (AVRS), or "balancers", have historically been developed and characterized to provide fault tolerance for generator designs that incorporate dual-opposed Stirling convertors or enable single convertor, or small RPS, missions. Balancers reduce the dynamic disturbance forces created by the power piston and displacer internal moving components of a single operating convertor to meet spacecraft requirements for induced disturbance force. To improve fault tolerance for dual-opposed configurations and enable single convertor configurations, a breadboard AVRS was implemented on the Advanced Stirling Convertor (ASC). The AVRS included a linear motor, a motor mount, and a closed-loop controller able to balance out the transmitted peak dynamic disturbance using acceleration feedback. Test objectives included quantifying power and mass penalty and reduction in transmitted force over a range of ASC operating parameters and mounting conditions. All tests were performed at three different piston amplitudes, 3.0, 3.75, and 4.5 mm. Overall, the transmitted force was reduced to 2 percent of the total unbalanced force by actively balancing out only the first fundamental frequency, with balancer motor power remaining under 1 watt. The test results will be used to guide future balancer designs.

Balancer↗

Active Vibration Reduction of the Advanced Stirling Convertor

Stirling Radioisotope Power Systems (RPS) are being developed as an option to provide power on future space science missions where robotic spacecraft will orbit, flyby, land or rove. A Stirling Radioisotope Generator (SRG) could offer space missions a more efficient power system that uses one fourth of the nuclear fuel and decreases the thermal footprint compared to the current state of the art. The Stirling Cycle Technology Development (SCTD) Project is funded by the RPS Program to developing Stirling-based subsystems, including convertors and controller maturation efforts that have resulted in high fidelity hardware like the Advanced Stirling Radioisotope Generator (ASRG), Advanced Stirling Convertor (ASC), and ASC Controller Unit (ACU). The SCTD Project also performs research to develop less mature technologies with a wide variety of objectives, including increasing temperature capability to enable new environments, improving system reliability or fault tolerance, reducing mass or size, and developing advanced concepts that are mission enabling. Active vibration reduction systems (AVRS), or "balancers", have historically been developed and characterized to provide fault tolerance for generator designs that incorporate dual-opposed Stirling convertors or enable single convertor, or small RPS, missions. Balancers reduce the dynamic disturbance forces created by the power piston and displacer internal moving components of a single operating convertor to meet spacecraft requirements for induced disturbance force. To improve fault tolerance for dual-opposed configurations and enable single convertor configurations, a breadboard AVRS was implemented on the Advanced Stirling Convertor (ASC). The AVRS included a linear motor, a motor mount, and a closed-loop controller able to balance out the transmitted peak dynamic disturbance using acceleration feedback. Test objectives included quantifying power and mass penalty and reduction in transmitted force over a range of ASC operating parameters and mounting conditions. All tests were performed at three different piston amplitudes, 3.0 mm, 3.75 mm, and 4.5 mm. Overall, the transmitted force was reduced to 2% of the total unbalanced force by actively balancing out only the first fundamental frequency, with balancer motor power remaining under one watt. The test results will be used to guide future balancer designs.

Active Vibration Reduction↗

Analysis and Experiment of Management Sciences Inc.'s Arc Fault Protection Connectors

The photovoltaics industry is in dire need of a cheap, robust, reliable arc fault detector that is sensitive enough to detect arc faults before they can develop into a fire while robust enough to noise to limit unwanted tripping. Management Sciences has developed an arc fault detector that is housed in a standard PV connector, which will disconnect the PV array when it detects the surge current from an arc fault. Sandia National Labs, an industry leader in the detection, characterization, and mitigation of arc faults in PV arrays, will work with Management Sciences to characterize, demonstrate, and develop their arc fault detection/connector technology.

14 SOLAR ENERGY↗