Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

A Tale of Two Hemispheres: Field Studies of Aerosols and Marine Stratocumulus Clouds (451st Brookhaven Lecture)

By reflecting sunlight, clouds may be mitigating the warming effect of greenhouse gases in the Earth's atmosphere. To discuss the roll that aerosol particles play in the cooling mechanism of clouds, Chemist Yin-Nan Lee of the Atmospheric Sciences Division of the Environmental Sciences Department will discuss “A Tale of Two Hemispheres: Field Studies of Aerosols and Marine Stratocumulus Clouds” during the 451st Brookhaven Lecture, beginning 4 p.m. on Wednesday 13 May in Berkner Hall. During his lecture, Dr. Lee will discuss his findings from collaborative studies of stratocumulus clouds over the coastal waters of California and Chile.

54 ENVIRONMENTAL SCIENCES↗

Plug Load Management System Field Study

In 2018, NREL performed a demonstration of the IBIS InteliNetwork(TM) plug load management system, which includes: intelligent socket devices, which plug into existing electrical outlets and collect energy usage information; a gateway, which manages communication between the intelligent sockets and the PLM cloud service; and a PLM network, which is a cloud-based measurement and control network for the entire system. Two retail stores served as the field study sites. The PLM system was found to be effective at reducing plug load energy use, with a projected annual plug load reduction of 11% and 18% at the test locations. Retail staff reported that the hardware was easy to use, but no one used the online data management system, intended to analyze and control the hardware. This PLM solution shows promise as an effective means to monitor, control, and reduce plug load energy use, but the economics of the system need to be improved.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Radioactivity of Sediments at the Atacama Rover Astrobiology Drilling Studies Field Site

Introduction: During the 2018 Atacama Rover Astrobiology Drilling Studies (ARADS) field activities, we conducted a survey of surface and subsurface sediment radioactivity. Our objective was to characterize the radiation environment of various near-surface sampling locations, as well as along the entire profile of a 2.60 m deep pit that had been dug near one of the ARADS rover drill site locations. This pit was used to collect samples that have been well characterized [2] for comparison to samples collected and analyzed by the rover.

ARADS↗

From fault-detection to automated fault correction: A field study

A fault detection and diagnostics (FDD) tool, as addressed by this study, is a tool that continuously identifies the presence of faults and efficiency improvement opportunities through a one-way interface to the building automation system and the application of automated analytics. Although FDD tools can inform operators of building operational faults, currently an action is always required to correct the faults to generate energy savings. Fault auto-correction integrating with commercial FDD technology offerings can close the loop between the passive diagnostics and active control, increase the savings generated by FDD tools, and reduce the reliance on human intervention. This paper presents the field study of seven fault auto-correction algorithms implemented in commercial FDD platforms. Implementation includes software changes in the FDD tools and additional controls hardware or software changes in the BAS that were required to enable the execution of different types of auto-correction algorithms in real buildings. The routines successfully and automatically correct faults and improve the operation of large built-up Heating, Ventilation, and Air Conditioning (HVAC) systems, common in most commercial buildings. The auto-correction algorithms are tested across four buildings and three different building automation systems, following a rigorous procedure to make sure they work properly and do not negatively impact the system and building occupants. Finally, technology benefits, market drivers, and scalability changes are drawn from the implementation effort and test results, to drive future research and industry engagement.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Field Study of 120-volt Heat Pump Water Heaters in the Big Easy

To meet long-term goals for reducing carbon emissions and lessen the impacts of climate change, the U.S. plans to decarbonize its building stock, which includes the replacement of fossil fuel-burning end uses with energy efficient electric alternatives. As part of this strategy, the replacement of fossil fuel water heaters with heat pump water heaters (HPWH) has the potential to avoid substantial carbon emissions. An estimated 10-15 million single-family homes with fossil fuel water heaters do not have the electrical panel capacity to install a 240-volt, 30-amp HPWH. For these homes, a technology recently introduced to the market, the 120-volt plug-in HPWH, can provide energy efficient electrification of water heating without an expensive panel and wiring retrofit. This paper presents the results of an ongoing 120-volt HPWH field study conducted in 17 homes in New Orleans, LA. Key installation scenarios are profiled for retrofitting from gas-fired water heaters to 120-volt HPWHs, accounting for space, air volume, air temperature, condensate drainage, and electrical. Each HPWH had its surrounding air temperature, relative humidity, inlet and outlet water temperature, flow, and energy consumption monitored. Using these data, hot water delivery and energy efficiency performance were analyzed based on home characteristics. Hot water run outs were investigated to understand how hot water usage, inlet water temperature, and surrounding air temperature impact the HPWH’s ability to meet load. From these results, best practices for 120-volt HPWH siting, sizing, and installation were developed. In addition, results are explored further to add insight for electrification policies and product development.

heat pump water heater, 120-volt, Residential buil↗

Mode Transitions in Glass Cockpit Aircraft: Results of a Field Study

One consequence of increased levels of automation in complex control systems is the presence of modes. A mode is a particular configuration of a control system that defines how human command inputs are interpreted. In complex systems, modes also often determine a specific allocation of control authority between the human and automated systems. Even in simple static devices (e.g., electronic watches, word processors), the presence of modes has been found to cause problems in either-the acquisition or production of skilled performance. Many of these problems arise due to the fact that the selection of a mode causes device behavior to be mediated by hidden internal state information. For these simple systems, many of these interaction problems can be solved by the design of appropriate feedback to communicate internal state information to the human operator. In complex dynamic systems, however, the design issues associated with modes seem to trancend the problem of merely communicating internal state information via displayed feedback. In complex supervisory control systems (e.g., aircraft, spacecraft, military command and control), a key function of modes is the selection of a particular configuration of control authority between the human operator and automated control systems. One mode may result in full manual control, another may result in a mix of manual and automatic control, while a third may result in full automatic control over the entire system. The human operator selects an appropriate mode as a function of current goals, operating conditions, and operating procedures. Thus, the operator is put in a position of essentially trying to control two coupled dynamic systems: the target system itself, and also a highly complex suite of automation controlling the target system. From a historical perspective, it should probably not come as a surprise that very little information is available to guide the design of mode-oriented control systems. The topic of function allocation (i.e., the proper division of control authority among human and computer) has a long history in human-machine systems research. Although this research has produced some relevant guidelines, a design approach capable of defining appropriate allocations of control function between the human and automation is not yet available. As a result, the function allocation decision itself has been allocated to the operator, to be performed in real-time, in the operation of mode-oriented control systems. A variety of documented aircraft accidents and incidents suggest that the real-time selection and monitoring of control modes is a weak link in the effective operation of complex supervisory control systems. Research in human-machine systems and human-computer interaction has barely scraped the surface of the problem of understanding how operators manage this task.The purpose of this paper is to present the results of a field study which examined how operators manage mode selection in a complex supervisory control system. Data on mode engagements using the Boeing B757/767 auto-flight system were collected during approach and descent into four major airports in the East Coast of the United States. Protocols documenting mode selection, automatic mode changes, pilot actions, quantitative records of flight-path variables, and verbal reports during and after mode engagements were collected by an observer from the jumpseat. Observations were conducted on two typical trips between three airports. Each trip was be replicated 11 times, which yielded a total of 22 trips and 66 legs on which data were collected. All data collected concerned the same flight numbers, and therefore, the same time of day, same type of aircraft, and identical operational environments (e.g., ATC facilities, weather patterns, traffic flow etc.)

Degani, Asaf↗

A field study of solid rocket exhaust impacts on the near-field environment

Large solid rocket motors release large quantities of hydrogen chloride and aluminum oxide exhaust during launch and testing. Measurements and analysis of the interaction of this material with the deluge water spray and other environmental factors in the near field (within 1 km of the launch or test site) are summarized. Measurements of mixed solid and liquid deposition (typically 2 normal HCl) following space shuttle launches and 6.4 percent scale model tests are described. Hydrogen chloride gas concentrations measured in the hours after the launch of STS 41D and STS 51A are reported. Concentrations of 9 ppm, which are above the 5 ppm exposure limits for workers, were detected an hour after STS 51A. A simplified model which explains the primary features of the gas concentration profiles is included.

Anderson, B. J.↗

Field Study of Nighttime Leakage Currents in Bifacial PV Modules: Correlation with Atmospheric Electric Field Data

Leakage currents measured on PV modules in the field originate from a potential difference between the modules' frame and the cells. They can be a relative indicator of Potential-Induced Degradation (PID) severity, especially when comparing the same module design in a different environment. As modules are not operating at night, no leakage current should be observed but our team has reported several events of nighttime leakage currents on bifacial PV modules. These events have been firstly observed during a thunderstorm that are characterized by strong atmospheric electrical field values. This lead us to believe that nighttime leakage currents could originate from the atmospheric electric charges. In this paper, we correlate nighttime leakage currents measured on bifacial PV modules with field mill data to identify the origin of nighttime leakage currents. Our results show that so far, no leakage currents at night occur when the atmospheric electric field is between 0 and 150–200 V/m (standard value for fair weather). As soon as the atmospheric electric field is out of this range, leakage currents are observed with or without rain involved. This suggests a transport of charged particles from the atmosphere to the modules' frame. A combination of heavy rain with strong atmospheric electric field results into high nighttime leakage currents with a magnitude up to 8 times higher than what observed during the day with -1500V applied. This is explained by an easier transport of the charged particles through the water droplets. Based on these results, leakage currents observed during the day might not be only due to the inherent potential difference between the frame and the cells depending on the atmospheric electric field activity. We believe that it should be taken into account in PID studies.

14 SOLAR ENERGY↗

Interaction Between Flames and Electric Fields Studied

The interaction between flames and electric fields has long been an interesting research subject that has theoretical importance as well as practical significance. Many of the reactions in a flame follow an ionic pathway: that is, positive and negative ions are formed during the intermediate steps of the reaction. When an external electric field is applied, the ions move according to the electric force (the Coulomb force) exerted on them. The motion of the ions modifies the chemistry because the reacting species are altered, it changes the velocity field of the flame, and it alters the electric field distribution. As a result, the flame will change its shape and location to meet all thermal, chemical, and electrical constraints. In normal gravity, the strong buoyant effect often makes the flame multidimensional and, thus, hinders the detailed study of the problem.

Yuan, Zeng-Guang↗

Solar magnetic field studies using the 12 micron emission lines. II - Stokes profiles and vector field samples in sunspots

Polarimetric observations at 12 microns of two sunpots are reported. The horizontal distribution of parameters such as magnetic field strength, inclination, azimuth, and magnetic field filling factors are presented along with information about the height dependence of the magnetic field strength. Comparisons with contemporary magnetostatic sunspot models are made. The magnetic data are used to estimate the height of 12 micron line formation. From the data, it is concluded that within a stable sunspot there are no regions that are magnetically filamentary, in the sense of containing both strong-field and field-free regions.

Hewagama, Tilak↗

Magnetic field studies by Voyager 2 - Preliminary results at Saturn

Results of Voyager 2 studies of the magnetosphere and planetary magnetic field of Saturn are presented. Magnetometer studies have confirmed the results obtained by Voyager 1, indicating the magnetic field to be that of a centered dipole of moment 0.21 gauss Saturn radii-cubed, tilted approximately 0.8 deg from the rotation axis and a maximum measured field intensity of 1187 nT at latitude 17.3 deg N just before periapsis. Voyager 2 observed multiple bow shock and magnetopause crossings during its inbound and outbound trajectories, which were complementary to those of Voyager 1, including magnetopause crossing at 18.5 Saturn radii on the inbound trajectory, and at 48.4-50.9 Saturn radii outbound indicative of magnetospheric expansion due to changing solar wind conditions. Throughout the outbound passage, the magnetospheric field was observed to be relatively steady and smooth, with no evidence for any azimuthal asymmetry or magnetic anomaly. Results thus are incapable of accounting for the observed periodic modulation of the Saturnian kilometric radio emissions.

Ness, N. F.↗

On the kinetics of dendritic sidebranching: A three dimensional phase field study

The underlying mechanism for dendritic sidebranching was studied using 3-D phase field modeling. Results showed that in 3-D the requirement of applying the random thermal noise to induce dendritic sidebranching (i.e., normally the case for 2-D phase field simulations) was fully relaxed. The stretching of the secondary or higher order arms occurred spontaneously and symmetrically as the growth of the dendrite. With periodic external perturbation and if the stimulating frequency was lower than a critical value, both tip velocity and sidebranching would get completely synchronized with the perturbation. Whereas if the perturbation frequency was higher than the critical value, rather than increasing, the sidebranching frequency would become stable and maintain at the same magnitude as that of the natural sidebranching, i.e., when no external perturbation was applied. It was shown that the underlying mechanism for sidebranching was deterministic rather than stochastic, and anisotropy tendency and curvature effect were shown to be the most important influence factors. Moreover, the difference of the anisotropy tendency would lead to an uneven distribution of curvature on the solid/liquid interface, i.e., formation of concave and convex geometries. The growth of these geometries would subsequently break the initial spherical structure of solid seed and lead to further sidebranching.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study: Preprint

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Combustion Safety Simplified Test Protocol Field Study

Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project team collected field data on 11 houses in 2015.

Building America↗

Combustion Safety Simplified Test Protocol Field Study

"9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Morphology selection in dealloying: A phase field study of the coupling among kinetic mechanisms

A phase field model is used to investigate how the corrosion rate and morphology of a dealloying metal is controlled by the kinetic rates of bulk solid diffusion, interfacial diffusivity, and interface dissolution. A specific focus is investigating the manner by which variations in these kinetic parameters synergistically influence the onset of a morphological instability at the solid-liquid interface, which is known to precede rapid dealloying corrosion towards highly topologically complex structures such as bicontinuous porous solids. This work demonstrates that this instability can be suppressed by either an increase of interdiffusion in the solid alloy, or by a decreasing rate of dissolution at the solid-liquid interface. When the instability is suppressed, the result is a relatively planar, passivated dealloying front. Importantly, however, coupled changes in kinetic parameters can also promote the morphological instability and sustain fine-scale ligament and pore formation. Finally, the relevance of the solid-liquid interfacial diffusion for determining the rate of dealloying and ligament formation is highlighted. By elucidating the mechanistic influence of bulk and interfacial kinetic factors on the dealloyed morphology, this work helps to rationalize the contrasting morphologies observed in various dealloying systems.

Diffusion↗