Search NASA⌕ Search

SEARCH · Search NASA

Results for “Field study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 91 records · Page 5

On the kinetics of dendritic sidebranching: A three dimensional phase field study

The underlying mechanism for dendritic sidebranching was studied using 3-D phase field modeling. Results showed that in 3-D the requirement of applying the random thermal noise to induce dendritic sidebranching (i.e., normally the case for 2-D phase field simulations) was fully relaxed. The stretching of the secondary or higher order arms occurred spontaneously and symmetrically as the growth of the dendrite. With periodic external perturbation and if the stimulating frequency was lower than a critical value, both tip velocity and sidebranching would get completely synchronized with the perturbation. Whereas if the perturbation frequency was higher than the critical value, rather than increasing, the sidebranching frequency would become stable and maintain at the same magnitude as that of the natural sidebranching, i.e., when no external perturbation was applied. It was shown that the underlying mechanism for sidebranching was deterministic rather than stochastic, and anisotropy tendency and curvature effect were shown to be the most important influence factors. Moreover, the difference of the anisotropy tendency would lead to an uneven distribution of curvature on the solid/liquid interface, i.e., formation of concave and convex geometries. The growth of these geometries would subsequently break the initial spherical structure of solid seed and lead to further sidebranching.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantifying the Value of Grid-Interactive Efficient Buildings through Field Study: Preprint

Quantifying the annual energy impacts of efficient technologies in commercial buildings has been well established by the building science field. As we move toward enabling grid-interactive efficient buildings (GEB) targeting flexible building operation and carbon reduction, quantification methods to evaluate time-sensitive peak load and emissions impact are much less defined. A number of national laboratories are working to field validate four different GEB software solutions that provide the capability to control multiple building end-use systems in multiple load flexibility modes (i.e., energy efficiency, load shed, load shift, and possible load modulation at the second to sub-second level). To guide the laboratory leads in effective measurement and verification (M&V) practices, two of the laboratories collaborated to define metrics to quantify the impacts of flexible load control on building demand, utility costs, carbon emissions, facility management, and occupant comfort. This paper summarizes the proposed metrics to quantify peak load and emission impacts in the field, decision parameters, approaches to accurately conduct M&V, lessons learned, and outstanding needs and next steps.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Combustion Safety Simplified Test Protocol Field Study

Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project team collected field data on 11 houses in 2015.

Building America↗

Combustion Safety Simplified Test Protocol Field Study

"9Combustions safety is an important step in the process of upgrading homes for energy efficiency. There are several approaches used by field practitioners, but researchers have indicated that the test procedures in use are complex to implement and provide too many false positives. Field failures often mean that the house is not upgraded until after remediation or not at all, if not include in the program. In this report the PARR and NorthernSTAR DOE Building America Teams provide a simplified test procedure that is easier to implement and should produce fewer false positives. A survey of state weatherization agencies on combustion safety issues, details of a field data collection instrumentation package, summary of data collected over seven months, data analysis and results are included. The project provides several key results. State weatherization agencies do not generally track combustion safety failures, the data from those that do suggest that there is little actual evidence that combustion safety failures due to spillage from non-dryer exhaust are common and that only a very small number of homes are subject to the failures. The project team collected field data on 11 houses in 2015. Of these homes, two houses that demonstrated prolonged and excessive spillage were also the only two with venting systems out of compliance with the National Fuel Gas Code. The remaining homes experienced spillage that only occasionally extended beyond the first minute of operation. Combustion zone depressurization, outdoor temperature, and operation of individual fans all provide statistically significant predictors of spillage.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Morphology selection in dealloying: A phase field study of the coupling among kinetic mechanisms

A phase field model is used to investigate how the corrosion rate and morphology of a dealloying metal is controlled by the kinetic rates of bulk solid diffusion, interfacial diffusivity, and interface dissolution. A specific focus is investigating the manner by which variations in these kinetic parameters synergistically influence the onset of a morphological instability at the solid-liquid interface, which is known to precede rapid dealloying corrosion towards highly topologically complex structures such as bicontinuous porous solids. This work demonstrates that this instability can be suppressed by either an increase of interdiffusion in the solid alloy, or by a decreasing rate of dissolution at the solid-liquid interface. When the instability is suppressed, the result is a relatively planar, passivated dealloying front. Importantly, however, coupled changes in kinetic parameters can also promote the morphological instability and sustain fine-scale ligament and pore formation. Finally, the relevance of the solid-liquid interfacial diffusion for determining the rate of dealloying and ligament formation is highlighted. By elucidating the mechanistic influence of bulk and interfacial kinetic factors on the dealloyed morphology, this work helps to rationalize the contrasting morphologies observed in various dealloying systems.

Diffusion↗

"Soiling, Cleaning, and Abrasion: The Results of the Five-Year Photovoltaic Glass Coating Field Study" [Slides]

External contamination ("soiling") of the incident surface is a major limiting factor for solar technologies. A 5-year field glass coupon study was conducted to better understand external contamination and its effects; compare cleaning methods and the use of preventative coatings; and explore the abrasion resulting from cleaning to advise on accelerated abrasion testing. Test sites included the cities of Dubai (UAE), Kuwait City (Kuwait), Mesa (AZ), Mumbai (India), and Sacramento (CA). Through the 5-year cumulative study, dry brush, water spray, and wet sponge and squeegee cleaning methods were compared to no cleaning. Optical microscopy was used to obtain images, including representative color images, grayscale images for object analysis, and oblique images for coating integrity assessment. A thresholding protocol was developed to analyze and distinguish specimens using the ImageJ software. Optical performance was quantified using a spectrophotometer, including comprehensive optical characterization (transmittance, reflectance, and absorptance in addition to forward- and back-scattering). Atomic force microscopy was used to verify the abrasion damage morphology, including the width and depth of surface scratches. Analysis of the results included correlation of optical performance and particle area coverage, rank order (by coating or location), and the acceleration factor for abrasion damage. The efficacy of external cleaning was more readily distinguished from the effectiveness of antisoiling coatings. The acceleration factor for dry brush cleaning of a porous silica coating was found to be on the order of unity.

14 SOLAR ENERGY↗

Conversion of Plastic Work to Heat: A full-field study of thermomechanical coupling

This project targeted a full-field understanding of the conversion of plastic work into heat using advanced diagnostics (digital image correlation, DIC, combined with infrared, IR, imaging). This understanding will act as a catalyst for reformulating the prevalent simplistic model, which will ultimately transform Sandia's ability to design for and predict thermomechanical behavior, impacting national security applications including nuclear weapon assessments of accident scenarios. Tensile 304L stainless steel dogbones are pulled in tension at quasi-static rates until failure and full-field deformation and temperature data are captured, while accounting for thermal losses. The IR temperature fields are mapped onto the DIC coordinate system (Lagrangian formulation). The resultant fields are used to calculate the Taylor-Quinney coefficient, β, at two strain rates rates (0.002 s -1 and 0.08 s -1 ) and two temperatures (room temperature, RT, and 250°C).

36 MATERIALS SCIENCE↗

Arctic Methane, Carbon Aerosols, and Tracers Study Field Campaign Report

The Arctic Methane, Carbon Aerosols, and Tracers Study was a measurement campaign at the National Oceanic and Atmospheric Administration (NOAA) Barrow Observatory and U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility North Slope of Alaska (NSA) sites in Barrow (formerly known as Utqiagvik) that involved the deployment of instruments to measure CH4, black carbon (BC), and source tracers. The campaign ran from September 1, 2014 to September 1, 2016 and was extended until July 30, 2017. We deployed an in situ instrument to measure methane, the ratio of its isotopologues 13CH4/12CH4, and ethane. We deployed a second instrument to measure carbon monoxide, carbonyl sulfide (COS), carbon dioxide, and water vapor. We also deployed an in situ instrument to measure BC, a single-particle soot photometer (SP2), at the nearby NOAA Barrow Observatory, co-located with the other NOAA aerosol instruments. Changes in emissions across different regions and seasons will be inferred using atmospheric transport and inverse modeling techniques.

North Slope of Alaska, trace gases, black carbon, ↗

Phenome‐to‐genome insights for evaluating root system architecture in field studies of maize

Abstract Understanding the genetic basis of root system architecture (RSA) in crops requires innovative approaches that enable both high‐throughput and precise phenotyping in field conditions. In this study, we evaluated multiple phenotyping and analytical frameworks for quantifying RSA in mature, field‐grown maize in three field experiments. We used forward and reverse genetic approaches to evaluate >1700 maize root crowns, including a diversity panel, a biparental mapping population, and maize mutant and wild‐type alleles at two known RSA genes,DEEPER ROOTING 1(DRO1) andRootless1(Rt1). We show the utility of increasing the dimensionality of traditional two‐dimensional (2D) techniques, referred to as the “2D multi‐view” method, to improve the capture of whole root system information for mapping genetic variation influencing RSA. Comparison of univariate and multivariate genome‐wide association study (GWAS) approaches revealed that multivariate traits were effective at dissecting complex RSA phenotypes and identifying pleiotropic quantitative trait loci (QTLs). Overall, three‐dimensional (3D) root models generated from X‐ray computed tomography and digital phenotyping captured a larger proportion of RSA trait variations compared to other methods of root phenotyping, as evidenced by both genome‐wide and single‐gene analyses. Among the individual root traits, root pulling force emerged as a highly heritable estimate of RSA that identified the largest number of shared QTLs with 3D phenotypes. Our study shows that integrating complementary phenotyping technologies helps to provide a more comprehensive understanding of the genetic architecture of RSA in field‐grown maize.

Genetics & Heredity↗

Laboratory Experiments and Modeling for Interpreting Field Studies of Secondary Organic Aerosol Formation Using an Oxidation Flow Reactor

This grant was originally funded for deployment of a suite of aerosol instrumentation by our group in collaboration with other research groups and DOE/ARM to the Ganges Valley in India (GVAX) to study aerosols sources and processing. Much of the first year of this grant was focused on preparations for GVAX. That campaign was cancelled due to political reasons and with the consultation with our program manager, the research of this grant was refocused to study the applications of oxidation flow reactors (OFRs) for investigating secondary organic aerosol (SOA) formation and organic aerosol (OA) processing in the field and laboratory through a series of laboratory and modeling studies. We developed a gas-phase photochemical model of an OFR which was used to 1) explore the sensitivities of key output variables (e.g., OH exposure, O 3 , HO 2 /OH) to controlling factors (e.g., water vapor, external reactivity, UV irradiation), 2) develop simplified OH exposure estimation equations, 3) investigate under what conditions non-OH chemistry may be important, and 4) help guide design of future experiments to avoid conditions with undesired chemistry for a wide range of conditions applicable to the ambient, laboratory, and source studies. Uncertainties in the model were quantified and modeled OH exposure was compared to tracer decay measurements of OH exposure in the lab and field. Laboratory studies using OFRs were conducted to explore aerosol yields and composition from anthropogenic and biogenic VOC as well as crude oil evaporates. Various aspects of the modeling and laboratory results and tools were applied to interpretation of ambient and source measurements using OFR. Additionally, novel measurement methods were used to study gas/particle partitioning. The research conducted was highly successful and details of the key results are summarized in this report through narrative text, figures, and a complete list of publications acknowledging this grant.

54 ENVIRONMENTAL SCIENCES↗

A phase field study of the thermal migration of gas bubbles in UO 2 nuclear fuel under temperature gradient

Phase field models are developed to study the gas bubble migration in uranium dioxide nuclear fuel in which a large temperature gradient exists during the operation. In this work, thermal diffusion mechanism for nanosized gas bubbles and vapor transport process for micron-sized gas bubbles are considered, respectively. In both cases, gas bubbles migrate to the high-temperature area. Due to the velocity difference between leading and trailing edges of the gas bubbles, nanosized gas bubbles are elongated along the temperature gradient direction when thermal diffusion is dominated. Micron-sized gas bubbles are either compressed along temperature gradient direction to form lenticular shape bubbles or elongated along temperature gradient direction, depending on the location of the gas bubbles within the fuel pellet. Initial gas bubble radius has no significant effect on the gas bubble migration velocity for both thermal diffusion and vapor transport mechanisms. We notice that the shape change of the gas bubble due to vapor transport mechanism has no significant effect on the migration velocity. Furthermore, the center cavity formation is also captured by our model which is due to the migration and accumulation of lenticular gas bubbles at the center of the fuel pellet. The modeling results compare well with experimental observations and theoretical analysis in the literature.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A field study setup of four homes having non-ventilated and semi-conditioned sealed attics

During the 2015-2016 fiscal year and with financial support from the Florida Building Commission (FBC) and the Florida Roofing and Sheet Metal Contractors Association (FRSA ), the University of Florida (UF) and the Oak Ridge National Laboratory (ORNL) completed Phase I of a study that setup four residential home demonstrations in Florida climate zones CZ-1A and CZ-2A. UF and ORNL are evaluating the hygrothermal (heat and moisture flow) performance and durability of sealed attic construction where expanded foam insulation is applied directly to the underside of the roof deck. The four homes are instrumented for measuring temperature and relative humidity of the indoor living space, the outdoor air and the attic air. In addition, the temperature, relative humidity and moisture content of the roof sheathing are being monitored and recorded by remotely-accessible data acquisition equipment. Here, air leakage tests on the whole house, on the sealed attic and in the HVAC ducts were conducted on all four homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparison of a laboratory and field study of annoyance and acceptability of aircraft noise exposures

Residents living in close, middle and distant areas from JFK Airport were included in a field interview and laboratory study. Judgments were made of simulated aircraft noise exposures of comparable community indoor noise levels and mixes of aircraft. Each group of subjects judged the levels of noise typical for its distance area. Four different numbers of flyovers were tested: less than average for each area, the approximate average, the peak number, or worst day, and above peak number. The major findings are: (1) the reported integrated field annoyance is best related to the annoyance reported for the simulated approximate worst day exposure in the laboratory; (2) annoyance is generally less when there are fewer aircraft flyovers, and the subject has less fear of crashes and more favorable attitudes toward airplanes; (3) beliefs in harmful health effects and misfeasance by operators of aircraft are also highly correlated with fear and noise annoyance; (4) in direct retrospective comparisons of number of flights, noise levels and annoyance, subjects more often said the worst day laboratory exposured more like their usual home environments; and (5) subjects do not expect an annoyance-free environment. Half of the subjects can accept an annoyance level of 5 to 6 from a possible annoyance range of 0 to 9, 28% can live with an annoyance intensity of 7, and only 5% can accept the top scores of 8 to 9.

Borsky, P. N.↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Magnetic field studies at Jupiter by Voyager 2: Preliminary results

The Voyager 2 magnetic field experiment is described and compared to the Voyager 1 experiment and data. The magnetosphere, the bow shock, the magnetopause, and the extended magnetic tail of Jupiter are discussed. Two crossings of the near equatorial current sheet were observed in the magnetosphere and its tail every 10 hour rotation period of the planet. A definitive mapping of the geometry and character of these enhanced plasma and depressed magnetic field regions is discussed. The interaction of the satellite Ganymede with the Jovian magnetosphere, which leads to disturbances as the Jovian magnetosphere corotates with the planet past the satellite is analyzed.

Ness, N. F.↗

Magnetic field studies at Jupiter by Voyager 2 - Preliminary results

The Voyager 2 magnetic field experiment, for which the instrumentation is identical to that on Voyager 1, operated flawlessly throughout the second Jupiter encounter. The paper presents a brief overview of the results obtained to date on the Jovian magnetosphere, the bow shock, the magnetopause, and the extended magnetic tail. The results and the magnetic field geometry confirm the earlier conclusion from Voyager 1 that Jupiter has an enormous magnetic tail, approximately 300-400 Jupiter radii in diameter, trailing behind the planet with respect to the supersonic flow of the solar wind. Additional observations of the distortion of the inner magnetosphere by a concentrated plasma show a spatial merging of the equatorial magnetodisk current with the current sheet in the magnetic tail. Disturbances near Ganymede are discussed.

Ness, N. F.↗